HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORWR405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method i Project Name: Lot 060 F1833 A RHG Den - E Builder Name: i �,ANNE[) Street: Permit Office: St. Lucie City, State, Zip: Ft. Pierce , FL, 34951 Permit Number:�� R3 Owner: Ryan Homes Jurisdiction: 661000 ORIf°1j/ Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing . �. New (From Plans) 9. Wall Types (171.6.0 -sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1369.30 ft2 b. Frame - Wood, Adjacent R=11.0 346.67 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 ,4. Number of Bedrooms 3 d. N/A R= ft2 1 10. Ceiling Types (1822.0 sqft.) Insulation Area 5. Is this a worst case? No 6. Conditioned floor area above grade.(ft2) 1833. a. Under Attic (Vented) b: N/A R=30.0 1822.00 ft2 R=" ft2 Conditioned floor area below grade (ft2) 0 _ z R f 11.cDucts R ft2 7. Windows(170.9 sgft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 366.6 a. U-Factor: Dbl, U=0.54 170.87 W. SHGC: SHGC=0.24 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 28.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13. Heating. systems, kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 27.8 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Zighied 14. Hot water systems Area Average SHGC:. 0.240 a. Electric Cap: 50 gallons 8. Floor Types (1833.0 sqft.) Insulation Area EF: 0.900 a. Slabbri-Grade Edge Insulation R=0.0 1833.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 i 15. Credits Pstat Total Proposed Modified Loads: 56:94 Glass/Floor Area: 0.093 PASS ' Total Baseline -Loads: 58.38 • I•hereby certify that the plans and specifications covered by Review of the plans and cUESz, �O this calculation are in compliance with the, Florida Energy specifications covered by this 0 Digitally signed y Bojan::!i� Code. BO an J Paukovic calculation indicates compliance . _.. • ate; 2018.09.1815:12:21 PauICOVIC with the Florida Energy Code. F,; lnri "� -=° , ; ��• PREPARED BY: DATE: Before construction is completed this building will be inspected for�r compliance with Section 553.908 *<.- . , •. �+'=: :`' ` I hereby certify that this building, as designed, is in compliance Florida Statutes. �ry, fig. with the lorida Energy Pode. OWNER/AGENT: ✓�w`J BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 On for whole house. I 9/18/20 8 3:10 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 4 V FILE COD FnRM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: i Lot 060 F1 B33 A RHG Den - Bedrooms: 3 User Conditioned Area: 1833 Ryan Homes Total Stories: 1 1 Worst Case: No Rotate Angle: 0 St. Lucie Cross Ventilation: No B61000 Whole House Fan: No Single-family New (From Plans) Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Lot Information 60 Oakland Lake . St. Lucie Ft. Pierce , FL, 34951 CLIMATE Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH MUNI 39 90 I 70 75 299 62 Low BLOCKS Number Name Area Volume I 1 Blocks 1833 15947.1 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1833 15947.1 Yes 4 3 1 Yes Yes • Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 158 ft 0 I 1833 ft2 ____ 0.29 0 0.71 ROOF # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Tested Insul. Pitch (deg) 1 Gable or Shed Composition shingles 1985 ft2 382 ft2 Dark 0.6 N 0.6 No 0 -22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1833 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 i Under Attic (Vented) Main 30 Blown 1822 ft2 0.1 Wood . I 9/18/2018 3:10 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-20.17 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Ornt To Space 1 N Exterior Concrete Block - Int Insul Main 4.1 28 6 8 8 247.0 ft2 0 0 0.6 0 2 E Exterior Concrete Block - Int Insul Main . 4.1 30 6 8 8 264.3 ft2 0 0 0.6 0 3 S Exterior Concrete Block - Int Insul Main 4.1 48 6 8 8 420.3 ft2 0 0 0.6 0 4 W Exterior Concrete Block - Int Insul Main 4.1 50 6 8 8 437.7 ft? 0 0 0.6 0 5 - Garage Frame - Wood Main 11 40 0 8 8 346.7 ft2 0 0.25 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height , Area Ft In Ft . In 1 E Insulated Main None .4 3 6 8 20 ft2 2 Wood Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang, Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth '.Separation Int Shade Screening 11 n 1 . Metal Low-E Double Yes 0.54 0..24 N 16.4 ft2 1 ft 0 in 2 ft 0 in Drapes/blinds None li e 2 Metal Low-.E Double Yes 0.54 0.24 N 49.0 ft2 1 ft 0 in 2 ft O.in Drapes/blinds None 3 s 3 Metal Low-E Double Yes 0.54 0.24 N 3.0 ft2 1 ft 0 in 2 ft 0 in Drapes/blinds None 4 w 4 Metal Low-E Double Yes 0.54 0.24 N 49.0 ft2 1 ft 0 in 2 ft 0 in Drapes/blinds None W 4 Metal Low-E Double Yes 0.54 0.24 N 53.3 ft2 1 ft 0 in 2 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 I 411 W. 411 ft2 64 ft 8.7 ft . 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 `1 Whol house Proposed ACH(50) .000387 1860.5 102;14 192.09 .2875 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity. Block Ducts 1 Electric Heat Pump/ Split HSPF:8.2 27.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 I Central Unit/ Split SEER: 14 28. kBtu/hr 840 cfm . 0.75 1 sys#1 9/18/2018 3:10 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM F# System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None f0 DUCTS ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 366.6 ft Main 91.65 ft Prop. Leak Free Main --- cfm 55.0 cfm 0.03 0.50 1 1 I TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin [ Jan Feb Heating H Jan H Feb Mar HX Mar Apr Apr May X Jun Jul May Jun Jul [X] Augj (] Aul Se ] Sep Oct Oct Nov Dec Dec Ventin l Jan , I ]] Feb Mar Apr l- May Jun Jul ] Aug [ ] Se Oct XNov X Nov lX [ ]] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78, 78 80 80 80 80 PM 80 80 78 7B 78 78 78 7B 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 76 78 78 78 7B 78 78 Heating (WD) AM 66 66 66 66 66 '68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 6B 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 6B 6B 68 68 68 68 68 68 66 66 I MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main Name: Test Rater Signature: Rating Compant: Test Rater Date: 9/18/2018 3:10 PM I EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: Permit Number: Ft. Pierce , FL, 34951 MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL I ❑R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components instilled in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and 'specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. El R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal enveldploe building thermal envelope shall comply with.Sections R402.4.1.1 and R402.4.1.2. I The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through B. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. I During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. I •. R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. I R402.4.3 Fenestration air IeakageWindows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per El square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAM� WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the- manufacturer. Exception: Site -built windows, skylights and doors. 9/18/2018 3:10 PM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 1. of 5 ! MANDATORY REQUIREMENTS - (Continued) f ❑R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall'be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully ga�keted and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passesIthrough conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. ❑ R402.415 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system: ❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section � C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (1), Florida Statutes, to be "substantially leak free" in ! accordance with Section R403.3.3. ❑ j R403.3.2.1 Sealed air handler. _ Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. ❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed.by the party conducting the test and provided to the code official. ❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 1050F (41 °C) or below 55°F (13°C) shall be insulated to a minimum of R-3. ❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. ❑ R403.5.1 Heated water circulation and temperature -maintenance systems (Mandatory). Heated water circulation systems shall be in j accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return ❑ pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. ! Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. 0 R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the,piping in accordance with the times when heated water is used in the occupancy. 9/18/2018 3:10 PM EnergyGaugeS USA - FBC 6th Edition (2017) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps (Mandatory). Storage .water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. 11403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable. temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140OF (38°C to 600C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water -heating systems to be turned off.' R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar I water -heating systems should meet the following criteria: i 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. i j R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall 'meet the efficacy requirements of Table R403.6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications: 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools .or spas. 3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment (Mandatory). ❑ R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions _described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shallhavean efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM (CFM) MINIMUM EFFICACY a (CFM/WATT) AIRFLOW RATE MAXIMU (CFM) Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt <90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916 9/18/2018 3:10 PM EnergyGauge@ USA - FBC 6th Edition (2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) ❑R403.7.1.1 Cooling equipment capacity. . Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's, product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The ipublished value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less.than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. ❑ h403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ R403.7.1.2.2. Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. ❑ R403.7.1.2.3'Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners i shall not be less than the design load calculated in accordance with Section R403.7.1. ❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections ❑ C403 and C404 of the IECC—' Commercial Provisions in lieu of Section R403. ❑ R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, I hall include automatic controls capable of shutting off the system when the pavement temperature is above 50oF (10°C), and no I recipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40OF (4.80C). ❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. ❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to.the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. ❑ R403.10.2 Time switches. Time switches or other.control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions:. 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. ❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: - Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or.solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal ❑ efficiency of 82 percent for heaters manufactured on or after April.16, 2013, when tested in accordance with ANSI Z 21.56.. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 9/18/2018 3:10 PM EnergyGauge@ USA - FBC 6th Edition (2017) Compliant Software Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is. required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 1 Portable spas (Mandatoryphe energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS ❑ R404.� Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. i 9/18I2018 3:10 PM EnergyGauge® USA = FBC 6th Edition (20.17) Compliant Software Page 5 of 5 i 2017 EPL DISPLAY CARD i ENERGY PERFORMANCE LEVEL (EPL) DISPLAY.CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. i 1 New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts. R 6.0 2; Single-family or multiple -family 2. 'Single-family b) Return ducts R 6.0 c) AHU location Attic/Main 3! No. of units (if multiple -family) 3. 1 41 Number of bedrooms 4. 3 13. Cooling system: Capacity 28.0 a) Split system SEER 14.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER i c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1833 d) Room unit/PTAC EER e) Other 7; Windows, type and area a) U-factor: (weighted average) 7a. 0.540 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.240 14. Heating system: Capacity 27.8 c) Area 7c. 170.9 a) Split system heat pump HSPF 8.2 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a).U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE I b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9.1 Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system I c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.90 b) Gas.fired, natural gas EF 16. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit . HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 111. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No i b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 2(�a0Q CZ ' City/FL Zip: Ft. Pierce, FL 34951 9/18/2018 3:10:27 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 20171 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Lot 060 F1833 A RHG Den - E Builder Name: Street: Permit Office: St. Lucie City, State, Zip: Ft. Pierce , FL, 34951 Permit Number: Y U Owner: Ryan Homes Jurisdiction: 661000 w Design Location: FL, Fort Pierce i U i COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity j sealed, with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and carjtilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage !separation Air sealing shall be provided between the garage and conditioned spac 3s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building. shall be sealed to the drywall: thermal envelope shall be air tight and IC rated. Plumbing and wiring � Batt insulation shall be cut neat) to fit around wiring Y 9 and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Pytpnd behind pip'ul and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier.s hall be installed behind electrical or communication exteriorwalls boxesor air -sealed boxes shall be installed. HVAC register boots . HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire so 'nkler cover Hates and walls or ceolffinas. a. In addition, inspection of log walls shall be in accordance with the provisions of ]CC-400. 9/18/2018 3:10 PM EnergyGauge@ USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 Pro ect Summary -- wrightsoft Entire House One Stop Cooling and Heating 7225 Sardscove Cowl, W inter Park, FL 32792 Ptnre: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwvt0reStopCoo1ing.com Licerse: CAC032444 i Proiect Information For: Ryan Homes . Notes: Job: Lot 060 F1833 ARHG Den Date: 06/07/2017 By: XF/Mc Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 68 OF Inside db 72 OF Design TD 26 OF Design TD 18 OF Daily range M Relative humidity 50 Moisture difference 68 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 17275 Btuh Structure 16190 Btuh Ducts 1765 Btuh Ducts 3491 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 19039 Btuh Use manufacturer's data n Rate/swin multiplier Equipmen[bad 0.95 18697 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3279 Btuh Ducts 897 Btuh Central vent (0 cfm) 0 Btuh j Heating Cooling (none) Area (ft2) 1853 1853 Equipment latent load 4176 Btuh Volume (ft3) 16123 16123 Air changesmour 0.38 0.20 Equipment Total Load (Sen+Lat) 22873 Btuh Equiv. AVF (cfm) 102 I 54 Req. total capacity at 0.75 SHR " 2.1 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfqq. Trade GOODMAN; JANITROL;AMANA DISTI... Trade GOODMAN;JANITROL;AMANADISTI... Model GSZ140301 K Cond GSZ140301 K AHRI ref 7995113 Coil ARUF31 B14A AHRI ref 7995113 Efficiency 8.2 HSPF Efficiency 12.0 EER,14 SEER Heating Input Sensible cooling 21000 Btuh Heating output 27800 Btuh @ 470F Latent cooling 7000 Btuh Temperature rise 0 OF Total cooling 28000 Btuh Actual airflow 0 cfm Actual airflow 933 cfm Air flow factor 0 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.82 Capacity balance point=33 OF Bolditalic values have been manually overridden Calculations approved byACCAto meet all requirements of Manual J 8th Ed. C -*- wrightsoft® 2018-Sep-1815:02:34 Fc ^P^ Right -St tOOUriversal201818.0.19 RSU16877 Page 1 I..ktop\TEMP PRIN-RLot060 F1833A RHG Den- E.rup Calc= MJ8 House faces: E -' wrightsoft- Right-JO Worksheet Entire House One Stop Cooling and Heating. 7225 Sandscove Cart, Winder Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStopCoolirg.com License: CAC032444 Job: Lot 060 F1833 A RHG Den - E Date: 06/07/2017 By. XF/MC 1 Room name Entire House MBED 2 3 4 5 Exposed wall Room height Room dimensions Room area 158.0 ft 8.7, ft d 1853.3 iP 30.5 It 8.7 ft. heat/cool 13.5 x 17.0 ft 229.5 ftz Tx Construdon number U-value (Btuh/ft--q Or HTM (BtjW) Area M) or perimeter (ft) Load (Btuh) Area (ft,) or perimeter (ft) Load (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool I 6 11 V� I �G Vdl i 13A flocs -- - -. _4A572om-.--=- 13A-4ocs 4A5-2om 11DO 13A-flocs -' , -_ 4A5 tom --- - 13A-4ors -- --:0.143 0.143 0.540 0.390 - - b.143 -- 0 540 0.143 -- H- --n_ a a a s __s_• w - -- - 3.722 -___ 14.04. 3.72 14.04 10.14 3.72 _ . 14.04, 3.72 ---- - 2.62 13.31 2.62. 28.62 _ 11b0 262 13.31. 2.62 `248 ._-___-16 265 49 - 20 422 `. 3 439 " - 2 _ _ _ _-- 196 0 _ _20 . 419 • - 3 - 337 - _ 861 -----.229 730 688 204 1558 - - 1252 - 60fi .__-.218 514 1403 231 _ 1096 --- 881 --- _._-----_0 0 0 0 148 - 0 - 117 -- O ,.__.__ _ .:0 0 0 0 -J 146. -- 9 85 0 _---- .-_o 0 0 0 - 550 __. _- .0 315 0 • --_---Q 0 0 __0 - 387 0 M2 Fj�� C 4A5-2om -16B 30 d - '- - 0.540 - 0 0 w -n 14.04 -- 10.83 28.62 _ 11:5 49 ----- a1853 0 —1853 688 ' J 15 1403 -3143 33 -- 230 0 `- 230 459 19� 936 _ -- 388 F 22Acpm.-._,.__._._. _. .._11$D ,_-_. _ 3068 000 1853 158 4847 0 230 _ 31 _--' _ 936. 0 1 - - - 7- ------------- - . _ ..._. _ _. _ _.. _ 6 c) AED excursion 570 252 Envelope loss/gain 14357 12507 2451 2186 12 a) Infiltration 2918 1063 563 205 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 2 460 Appliances/other 170D 0 Subtotal (lines 6 to 13) 17275 16190 3014 2851 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17275 16190 3014 2851 15 Duct loads 10% 22% 1765 3491 10 0 22% 308 615 Total room load 19039 19681 3322 3466 Air required (dm) 01 933 0 164 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wrlgt�ts'oft' 2018-Sep-1 8 15:02:34 Right-SUte®Ureversa12018 18.0.19 RSU16877 Page 1 ktop\TEMP PRINT\Lot060 F1833A RHG Den- E.rup Calc= MJ8 House faces: E - - wrightsoffr Right-J® Worksheet j Entire House One Stop Cooling and Heating 7225 Sardscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www..0neStopCoolirg.com License: CAC032444 Job: Lot 060 F1833 A RHG Den - E Date: 06/07/2017 By: XF/MC 1 Room name lvBTH MWIC 2 3 E iposed wall Room height 15.0 ft 8.7 ft heat/000l 0 ft 8.7 ft heaU000l 4 5 Room dimensions ' Room area 1.0 x 107.5 ft. 107.5 ft2 7.0 x 11.0 ft 77.0 ff Ty Construction number U-value (Btuh/f--o Or HTM (BtuhV) Area or perimeter (ft) Load (Btuh) Area or perimeter (ft) Load (Btuh) Heat Cool Gross ' N/P/S Heat Cool Gross N/P/S Heat Cool 6 , 13A flocs - .4A5.2om 13A-4ocs 0.143 - _ _0.540 0.143 " n - __n_ a 3 72 _ _,14.04: 3.72 2 62 __-. 1331! 2.62 ..:.. _ .• •,. 0 _ ---- _ 0 0 ,0 _ _ _.0 0 0 - - --___:0 0 0 _ --_-__ -0 0 ---_ _ _0 0 0 0 . _ , 0 0 11 LI4A5-20m D UV��J1 ,_c ' G:4A5.2om------- 11DO ---'-...... 05A0 0.390 0.143 0.540_ a a -s - s__ 14.04 10.14 372 28.62 11.50 - 262 0 0 131'. 0 0 - - 127 3._--_,_•43:.._.-__ 0 0 ----474 0 0 - -334 0 0 _0 ______Q. 0 0 _-. O ___-_0--.-__0 0 0 0 0 _ •.-0. Vfl 13A-flocs 0.143 w 3.72 2.62 0 0 0 0 0 0. 0 0 - D. C 4A5-tom 4A52omd _._. .__. 12C Osw 11D0__ _ -- - 166-_30_ad 0.540 0.540 _._ ._ 0.091 _0.390 0.032 w W. __ - _ n_ 14.04 _ 1404 2.37 ._ 10.14 0.83 28.62 32.78 1;33 _J1,b0 1.70 0 _ 0 i0 :. __ _._z0 108 0 -0 ,- 0 _ _ .-0 108 0 0_,-. 0 . -" 0 89 0 0 0 --0 182 0 __ _0__. 0 - - 0 77 0 _-'_ 0._ 0 ----- A 77 0 _ 0 . --0 --- 0 64 0 0 ---0 131 _ -V - -- --- - -- -- - - .0:00 -- .______. __.. 108 -- ----- - 15 ----- .----- - - --- 0 -.�.- --• ---• 77 - --- _0 - - - : .__0 - -- . _ _Q ---- -- -- - -- -. - - - - - I' - - ... 6 d)AED,excursion -42 -8 Envelope loss/gain 1066 514 64 122 12 a)Infiltration 277 101 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances(other 0 0 Subtotal (lines 6 to 13) 1343 615 64 122 Less; e)d malload 0 0 0 0 Less transfer 0 0 0 0 .Redistribution 0 0 0 0 14 Subtotal 1343 615 64 122 15 Ddctloads 10% 22% 137 133 10%1 229/6 7 26 .I Total room load Ai 1required (cfm) 1480 0 748 35 71 0 149 7 ACCAto meet all requirements of Manual. J 8th Ed. -�- wrigF�tsoft�° - Rigii-Suite®Uriversal201818.0.19RSU16877 . A ...ktop\TEMP PRINT\Lot 060 F1833A RHG Den- E.rup Calc= W8 House faces: E 2018-Sep-1815:02:34 Page 2 w�rightsoftN Right-JO Worksheet Entire House One Stop Cooling and Heating. 7225 Sardscove Covet, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStopCooling.com License: CAC032444 Job: , Lot 060 F1833 A RHG Den- E Date: 06/07/2017 By: XF/MC 1 Room name DEN FOY 2 3 E)q. osedwall^ Room height 30.0 ft 8.7 ft heaUoDol 5.5 ft 8.7 ft. heat/000l 4 5 Room dimensions Room area 13.5 x 13.0 ft 175.5 ft2 5.5 -x 9.5 ft 52.3 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area M) Load number (Btuh/ft2-°F) (Btuh/ftz) or perimeter (ft) (Btuh) . or perimeter (ft) (Btuh) Heat Cool Gross N/F/S Heat Cool Gross NIPS Heat Cool 6 . y/ ,' u 13A=flocs _ .__ --- - -4A5 tom.---- -- _.:- ---,0.143 - 0.540 - n -_n. --- 3.72 _ __14.04- 2 62 t-1331 ;i :- - - 30 _ - 0, 30 _ -._--0 --- ---113 ---0 '-_ --- ,80 - --0 - _ -O _ - 0 - -_- - --- 0 O-_0 _ _� :• 103 13A-flocs 0.143 a 3.72 2.62 117 101 376 265 48 28 73 i 4A5-2om 11 D0 13A-flocs :4A5 2om .. _ ._ _. 0.540 0.39D 0.143 0.540 a a s - -s- 14.04 10.14 ^3.72 -- 14.04 28.62 11.5D - 2'62 __ . 1331' 16 0 - 113 - ._ .-0 0 0 113 . _ - _ .•D 229 0 0 468 0 - --0 0 20 -- -0 0 20 0 -- _0 0 ^ 204 0 - 0 0 231_ 0 - - 0 LD L-L-G �j�--G 13A-4. 0.143 w 3.72 2.62 0 0 0 0 0 0 0 0 L G 4A5-2om 4A5-2omd 0.540 0.540 w w_ 14.04 14.04 28.62 32.78 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12COsw __.,__ .,... .-0.091 2.37 1.2b 0 _0 0----0 0 ---0 _ -0 - 0 _11D0 _--_-- _-- -_ _ __ _-0.390 --n--. --_10.14 -_ 11.50 ._ _- 0 : _ 0 -._ 0 _ ._..._'0._ -.-.--_0 _ -_ _ 0 _- -- _0 -- 0 C 16B-30ad 0.032 0.83 1.70 176 176 146 298 52 52 89 _F _ _ ;22A cpm _ _ 1.18D 30 68 0 00 _ 176 30 920 -0 - __ '_ 52 _ 6 _43 169 0 - -- - ----- - 6 c) AED excursion -11 -27 Envelope loss/gain 2205 1395 519 365 12 a) I Infiltration 554 202 102 37 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 - 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 2760 1597 621 402 Less extemalload 0 0 0 0 Less transfer Redistribution 0 241 0 156 0 -621 0 -402 14 15 Subtotal Ductloads 101/1 22% 3000 306 1753 378 10% 22% 0 0 0 0 Total room load Air required 3307 0 2131 101 0 0 0 0 Calculations approved byACCAto meet all requirements of Manual J 8th "Ed. wrlgt �tsoft ° Right-StDte®Urrversal 2018 18.0.19 RSU16877 201 E-Sep-1815:02:34Page 3 ktop\TEMP PRINT1Lot060 F1833A RHG Den- Exup Calc= W8 House faces: E Job- - - wrightsofta Right-J® Worksheet Date: Entire House B I By: One Stop Cooling and Heating 7225 Sandscove Court. W inter Park, FL 32792 Phone: (407)"629 - 6920 Fax: (407) 629 - 9307 Web: www.0neStopCooIirxj.c6m License: CAC032444 WOW F1833 A RHG Den- E 06/07/2017 XF/MC 1 2 3 4 5 Room name E>�posed wall Room height Room dimensions Room area DIN 15.0 ft 8.7 It heat/000l 11.5 x 13.0 ft 149.5 ft2 KIT 0. It 8.7 ft heat/mol 1.0 x 324.0 It 324.0 tt2 i Ty Construction number U-value (BtuhHTt°F) Or HTM (Btuh/f6) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat ' Cool Gross N/P/S Heat Cool 6 11 `V�! ! VIl �--G y/ 1 + G D ~ 13A flocs -4A5-2om.._-- - ....__. 13A-4ocs 4A5-2om 11D0 _ -_ _.. 13A-flocs 'n4A5 tom. 0.143 __-_ -0.540 0.143 0-w .., 0.390 0.143 0.540 n- __n ._ a a e _ s . L: 3 72 _ _.. 14.09: 3.72 14.04 w 10_14 3 72 _ _1404 2.62 _ 1331 2.62 28.62 11.50 2 62 13.81: ; p ;_ ;__;0 100 33 _ ._,__ 0 30 ' _ _, _ 0 0 - _ _._. 67 0 ___0 30 __ __._0 0 _,___0 250 459 _0 113 _,-_._. __0 0 _•_`w_0 176 936 .__ 0 - 80 _.__._..__0 - 0 �.,0 0 0 __.0 . 0 :__._ _ _ 0 ._ 0 _. 0 0 -,-,---__0: 0 0 :_ __- 0. 0 0 0 _ -- -- 0 •_._ .._ . -0' 0 0 00 ;,...__. _._.Q -I C G D 13A-flocs 4A5-2om 4A5 2omd , _ _ . _ 12C Osw _j1D0.._ -__:__._.0 16&30ad 22A,cpm.._ 0.143 0.540 0.540 0.091 0.032 1.180 w w w _.._... 3.72 14.04 14_04 2 37; 0.83 _ . 30.68. 2.62 28.62 32.78 1 33 1.70 _ ..,. 0 0 _� _ 0 r ii3 150 0 0 _ _. _. 0 113 150 0 0 ..----_ - 0 268 124 0 0 _. 0 150 254 0 0 0 61 324 0 0 0 61 324 0 0 0 144' 0 0 0 . - ' 81. _Q 550 270 - -- --- • _..... - .. _ . ..- s , .,. - • ------ ----- -- ...... 6 c)I� AED excursion 76 -117 Ehvelope loss/gain 1675 1671 ' 414 514 12 a) Infiltration 277 101 0 0 b) Room ventilation 0 0 0 0 13 Irjternalgains: OccupantsQa 230 0 0 0 0 Appliances/other 0 1200 Slubtotal (lines 6 to 13) 1952 1772 414 1714 Less external load " 0 .0 0 0 Less transfer 0 0 0 0 F edistribution 241 156 142 96 14 15 Subtotal Duct loads 10% 22% 2192 224 1928 416 10% 22% 55.6 57 1809 390 Total room load 2416 2344 613 2200 Air required (dm) 0 111 0 104 -�• wrigF�tsotFt^ ' Right-SulteO Udversa1201818.0.19 RSU16877 ktop\TEMP PRIN-I\Lot060 F1833A RHG Den- Exup Calc= W8 House faces: E th Ed. 2018-Sep-1815:02:34 Page 4 - - wrightsoft9 Right-JO Worksheet Entire House One Stop Cooling and Heating. 7225 Sar: stove Cant, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: ewAoreStopCooling.com License: CAC032444 Job: Lot 060 F1833 A RHG Den - E Date: 06/07/2017 By: XF/MC 1 Room name GRT BTHi 2 Eiposed wall 17.0 ft 6.0 ft 3 4 5 Rbom height Rbom dimensions Room area 8.7 it heaUmol 17.0 x 14.0 H 238.0 i2 8.7 it heat/cool 1.0 x 79.5 it 79.5 ftz - Ty Construction U-value Or HTM Area (T) Load Area Load number BWh/ft2° Btih/ftz or perimeter ft Btuh or perimeter ft Btuh Heat Cool Gross N/PiS Heat Cool Gross N/P/S Heat Cool 6 ^UV I - 13A flocs 0143 ri y 372 ` 2.62, .o _._0 O ._.__-.__ !-G 4A5-tom- - --- . 0.540 _ n _ _ 14.04. __ 13.31 -- - --0 - - -0 - --- - 0 - ---- 0 ---- _..0 --- ---0 _- --- 0 -_.0 13A-40rs 0.143 a 3.72 2.52 0 0 0 0 0 0 0 0 VD 4A5-2om 0.540 a 14.04 28.62 0 0 0 0 0 0 0 0 11 y/ - 11DO -13A 466s - ._ - _ 0.390 0.143 a s_., 10.14 _ $ 72 1150 ' . - 2.62 0 - _0 0 .. 0 0 - 0 0 - .0 _„ 0 0 0 '0 0 0 -0 0 i , G .4A5-tom -- - 13A-flocs - 0:540 0.143 . s w 1404 3.72 _ _13.31 2.62 0 148 0 94 - 0 351 - - 0 247 -- -0 52 - -- 0 52 - - - '0 194 - - 0. 137 ' R--- ii� _.. 4A5-2om 4A5-2omd - . -- - - - - - - 0.540 0.540 : -. 0.091 w w - _ 14.04 14.04 - 2.37 28.62 32.78 - 1 0 54 -- - 0 0 0 0 753 0 1757 0 0 0 0 0 0 0 0 _'_ I D- 11D0.._ -- _ ._-- ---___..___._ 0.39D.__n_ __. 10.14 ---11.50----._. 0 __.-_-_._0-_.----__0 _A'__. _._--_A _ 0--_-_.- _.0,'----___ .0- C 16B 30ad 0032 083 1.70 238 198 404 80 80 66 135 F _. __- .._ �22A-c- ._ :... _ _. - 1.180 _.... .- _. 30 68; 0.00 _ ,. _ . .. 238 ,238 .. 17 .._ _ .-.522 - _ _ . 0 __ _ ..:. 80 - -- '6 - . - -184 _ _ _ -_. A i _1 . -_ - - - _ 6 c) AED excursion 503 -20 Envelope loss/gain 1823 2911 444 252 12 a) I Infiltration 314 114 111 40 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 .0 0 0 j Appliances/other 0 0 Subtotal (lines 6 to 13) 2137 3025 555 292 Less extemal load Less transfer Redistribution 0 0 3 0 0 6 0 0 9 0 0 17 14 15 Subtotal Ductloads 10% 22% 2140 219 3031 654 10% 22% 564 58 309 67 Total room load 2358 3684 622 375 Air required (cfm) 0 175 0 18 rements of Manual J 8th Ed. �- wrightsoft' P: IRIgii-Srrite®Uruversal 2018 18.0.19 RSU16877 .ktop\TEMP PRIMkot06D F1833A RHO Den- Exup Calc= MJ8 Hose faces: E 2018-Sep-18 15:02:34 Page 5 wrightsoft- Right-JO Worksheet Job: Lot 060 F1833 ARHG Den - E Entire House Date: 06/07/2017 By: XF/MC One Stop Cooling and Heating 7225 Sarjscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fa)O. (407) 629 - 9307 Web: www.0neStopCoolirig.com License: CAC032444 1 Room name BED2 AC 2 BOosed wall 26.0, ft 0 It 3 Room height 8.7 ft heaVcc)ol 8.7 ft heat/cool 4 5 Rbom dimensions Room area 1.0 x 160.5 ft 160.5 ft2 5.5 x 3.5 ft 19.3 ft2 Ty Construction U-value Or HTM Area (111) Load Area OF) Load number (Btuh/ft--F) (Btuh/ft2) or perimeter (ft) (Btih) or perimeter (ft) (Btuh) Heat Cool Gross; N/P/S Heat Cool Gross N/P/S Heat Cool 6 .1 3A-4ocs _4A&2om_-___-- 13A-40cs -0540 0.143 -n -- e ----- J 4.04. 3.72 13 31: 2.62 '- -' -.----o 0 ---- _0 0 388 273 0 0 0 _0 0 -0 0 \L _--'-'.o 0 0 0 - 11 4A5-2cm 11DO - - I - - 13A-40CS 4A572orn 13A-4ocs 0.540 0.390 -.- ."- '0.143 0W 0.143 e - e 's ---,S-- w 14.04 10.14 '3.72 4 04. -.--I . 3.72 28.62 11.50 2162 -- -.13.31 2.62 0 -- .. - -P 0 - 122 0 _.- - _ -0 .0 .,--0 105 0 0 .0 392 0 0 0 06 0 0 0. 0 6 0 0 0 0 0 0 0 0 --0 0 0 0 0 '-Q 0 -L-G D AVI j II I�G 4A5-2om 4A5-2omd 0.540 0.540 w w 14.04 14.04 28.62 32.78 16 0 0 0 229 0 468 0 0 0 0 0 0 0 0 C 120-Osw 1613-30ad 0'69 0.032 0.83 1.70 161 161 6 134 -b 272 0, '19 0 0 19 0 . ...... 0 -16 0 __0 33 .E. -22A-.Cpm,- 7- r 80 ac�b -1-Ii 6 71 , .... .. .. ... . . - - ..... - -- - ---- 98 -- ------ ---- 0 -.19 7 - '0 ---- --- -----0 7 .. -------0 ---- ------------ --:7- c) A ED excursion 101. -2 Envelope loss/gain 1941 1390 16 31 12 a) Infiltration I 480 175 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 2421 1795 16 31 Less external load Lesstransfdr Redistribution 0 0 5 .0 0 10 0 0 -16 0 0 -31 14 15 Subtotal Du& loads 10%1 22-/.j 2426 248 1805 389 10%1 229/61 0 0 0 0 ToIll room load Air required (cfm) -F 2674 01 21941 104 ------ j -0� 0 01 0 Calculations approved by ACCA to meet all requirements of I&4,id- - wwrv"wvIt!SCXVe- Right -Suite@ Universal 201 1 8 18.0.19 RSUI 6877 201 B-Sep-1 8 15:0224 K i..ktop\T^E-M,P*,P-RI-NPI"LlotO6O F1833A RHO Den- E.rup Calc=MJ8 Housefares:E Page 6 - wrightsilft9 Right-JO Worksheet Job: Lot060 F1833 ARHG Den -E Entire House Date: 06/07/2017 By: XF/MC One Stop Cooling and Heating. 7225 Sarr stove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopGoolirg.com License: CAC032444 1 Room name BED3 LAUN 2 3 4 5 0posedwall , Room height Rbom dimensions Rbom area 13.0 ft 8.7 ft heattoDol 1.0 x 154.8 It 154.8 it' 0 ft 8.7 ft heallcool 1.0 x 48.0 ft 48.0 1t2 Ty Construction number U-value (Btuh/ft--9 Or HTM (Btuh/ft) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft) or perimeter (ft) Load (Btuh) Heat Coo l Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 ' r D _L-_ G 13A 4ois _ _ • -- 4A5 tome---__;_ 13A-4ocs 4A5-26m 11 D0_ 4A5-2om .. - 13A-4ots 0.143 __.. 0.540 0.143 0.540 0:390 0.143 ------ 0.540 0.143 n _ n_ a a a _ s _ _ s._ w 3 72, . -_ 1404„___13:31 3.72 14.04 10.14 3.72 ___14.04 3.72 2.62 2.62 28.62 11.50 2.62 _ 13.31: 2.62 113 =---_•16 0 0 0 _ _ . -• 0 _ �- 0 0 97 %;-•--._ --0 0 0 0 - - - ---p - --- 0 0 380 -- _ - _229, 0 0 0 -- --- 0 0 0 - - 253 _-_218 0 0 0 --- -- -O 0 0 - - 0 _.0'-,__..._ 0 0 0 -- - --- � 0 '- 0 .0 0 0 � _ _. 0 0 0 0 •-_-- _ _0. 0 0 0 _--_ __0 0 0 __... ' _ :0. 0 0 0 -- 0 0 R �D C 4A5-2om 4A5-2omd _-. _._ 12C OsN 11 D0B-3-----0.390 160ad- 0.540 0.540 0.091 0.032 w w --n - 14.04 14.04 2.37 ---10.14. 0.83 28.62 - 32.78 .1.33 - -- -i1 50 1.70 0 0 117 .:. _- -_0 155 0 0 117 ____ _ __0 155 0 0 278 --- __ ___0 129 0 0 156 _.. _ --- 0 262 0 : 57, - -- 18 48 0 _. -- ---� 39 --- - . - 18 48 0 .-,--- _-_ 0 92 _ _- 181. 0 -- -._ 0. 51 _----- 206 • F:;. ..:.22A-cam.- -1 - ---.._ -_ _ - ----- -....- ._ J.180 ---- -- _..- - _-.. ----- _:_-30.68•.__-.0.00 - -- - - -- - ,. -_155 _ ._ -• 13 - - - -- .. - -- -v - - _ - _ __ ._.-_40 - ._-_. _- _81_ --- -- -0 - - - • L • r.. 6 c) QED excursion -77 -54 Envelope loss/gain 1395 812 313 285 12 a)l Infiltration 240 87 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 1 230 0 0 Applianoes/other 0 500 Suibrotal (lines 6 to 13) 1635 1130 313 785 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 14 27 13 26 14 Subtotal 1649 1157 326 811 15 Ductloads 110% 22% 168 249 10% 22% 331 175 Total room load 1817 1406 359 985 Air required (cfm) 0 671 0 47 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 4$1- wrigF+Eso1FtA 2018-Sep-1815:0234 Right-Suite®Universal 201818.0.19RSU16877 Page7 ktop\TEMP. PRINi\Lot060 F1833A RHG Den- Ex p Calc= WB House faces: E - wrightsoft, Right-J® Worksheet Entire House One Stop Cooling and Heating. i 7225 Sar dscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 - Web: www.OnoStopCooling.com License: CAC032444 Job: Lot 060 F1833 A RHG Den - E Date: 06/07/2017 By: . XF/MC 1 Room name H1 2 3 Eiposed wall Rbom height 0 ft 8.7 ft heat/000l 4 5 Room dimensions Rbom area 9.5 x 4.0 ft 38.0 it' Ty Construction number U-value (Btuhlt--F) Or HTM (Btuh/fF) Area, (fly) or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/s Heat Cool Gross N/F/S Heat Cool 6 _�--G 13A-flocs - .4A5-2om_--- -_ _ 13A-4ocs 0.143 .^-.-- 0.5-40 0.143 _n • a .. - 14.04 3.72 N. 1331..: 2.62 _. -Q 0 ---- 0 0 - 0 , _0 0 -_O ,- __ _-- 0 0 . _._ _.- 11 L-G V}/ a r Vr/ 4A5-2om 11DO 13A flocs :4A5 2om-- - .. 13A-4ocs 0.540 0.390 0.143 , _- 0:540 0.143 a a - s -_ s_ w 14.04 10.14 3.72 : - 14.04 3.72 28.62 11.50 262 . -13 31; 2.62 0 0 r D • --- - 0 0 0 0 - 0 ------0 0 0 0 -_. 0 ._ .. ,.0 0 0 0 _._ O --.-0 - 0 0 . __ • - _ --.._._...__...- -- -- = - -- _ -_--_ _ _ _ - -- _._ - -- IL '—GG _' C 4A5-2om 4A5-2omd 12C-0sw - _-- 11 DO--. ----- 1613-30ad 0.540 0.540 - - r0,091 :.-_.-0.390 0.032 w w_ _ _n 14.04 1404 2 37 -- _1014 0.83 28.62 32.78 1 33 J1.50 1.70 0 0 •0 _ _._.- _0 38 0 - 0 0 38 0 0 0 0 0 0 32 ,F - 22A (pm - -- _ -_ . _ 1.180 - - -- 30.68 . 0 00 38 0 - - - ---- -- - - - -- - - -. _ --- T ^ 6 c) AED excursion -4 i Envelope loss/gain. 32 60 12 a)! Infiltration 0 0 b); Room ventilation 0 0 13 Internal gains:. Oocupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 32 60 Less external load 0 0 Lesstransfer Redistribution 0 -32 0 -60 14 15 Snibtotal Duct loads 10% 229/6 0 0 0 0 Total room load Ai required (cjm) 0 0 0 0 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -f'F1- wrr7gtitsof'e^ 201 8-Sep-1 8 15:0224 . G`P. Right -Suite® Universal201818.0.19RSU16877 Page ktop\TEMP PRINMot060 F1833A RHG Den- E.rup Calc= W8 House faces: E -�- wrightsoft® Duct System Summary Entire House One Stop Cooling. and Heating 7225 Sandscove Cowt, W irder Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OngStopCoolirig.com License: CAC032444 nor: hyan Homes FL Job: Lot 060 F1833 ARHG Den Date: 06/07/2017 By. XF/MC I Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.16 in H2O 0.16 in H2O Available static pressure 0.34 in H2O 0.34 in H2O Supply/ return available pressure 0.170 / 0.170 in H2O 0.170 / 0.170 in H2O Lowestlfriction rate 0.228 in/100ft 0.228 in/100ft Actual airflow 0 cfm 933 cfm !Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR. Diam (in) H x W (in) Duct IVlatl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BED2 c 2194 0 104 0.292 6.0 Ox 0 MR 11.6 105.0 sti BEDS c 1406 0 67 0.305 6.0 Ox 0 VIFx 11.3 100.0 sti BTH1 c 375 0 18 0.266 4.0 Ox 0 VI Fx 12.9 115.0 sti DEN c 2131 0 101 0.233 6.0 Ox 0 VIFx 35.7. 110.0 st2 DIN c 2344 0 111 0.234 5.0 Ox 0 VIFx 35.1 110.0 st2 GRT c 3684 0 175 0.228 8.0 Ox 0 VIFx 29.2 120.0 st2 KIT c 2200 0 104 0.253 5.0 Ox 0 VIFx 24.5 110.0 st2 LAUN c 985 0 47 0.466 4.0 Ox 0 VIFx 3.0 70.0 MBED c 3466 0 164 0.240 7.0 Ox 0 VIFx 31.4 110.0 st2 MBTH c 748 0 35 0.230 4.0 Ox 0 VI Fx 32.9 115.0 st2 MW Ic c 149 0 7 0.239 4.0 0x 0 VI Fx 27.0 115.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type . (cfm) (Cfm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 0 698 0.228 653 14.0 0 x 0 VinlFlx sti PeakAVF 0 188 0.266 705 70 0 x 0 UnlFlx Boldrdalic values have been manually overridden wrightsoft® 2018-Sep-1815:02:35 .rR•.+rm�.- .. � , Right-Stite®Uriversa1201818.0.19 RSU16877 Page 1 ktop\TEMPPRINT\Lot060F1833ARHGDen -Exup Calc=MJ8 House faces: E I Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm). Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rbi Ox 0 0 933 0 0 0 0 Ox 0 VIFx i I I I - wrightsoftm 2018-Sep-1815:02:35 �,. � •umeim�wwu..e�w� RigFd-Sprite®Uryversa1201816.0.19 RSU16877 Page 2 '�..ktop\TEMPPRINTIM060F1833ARHGDen-E.rup Calc=W8 Hometaces: E Static Pressure Friction Rate Job: Lot 060 F1833 ARHG Den -�- wressure anon rightsoft® Date: 06/07/2017 .Entire House By: XF/MC One Stop Cooling and Heating 7225 SarLwve Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax:'(407) 629 - 9307 Web: www.0neStopCooling.com License: CAC032444 For: Ryan Homes FL r Icaur ry (in H20) va,vm 1y (in H2O) Exterrltal static pressure 0.50 .0.50 Pressurelosses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0.03 0.03 Return grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 ( Balancing damper 0 0 Other device 0 0 Available static pressure 0.34 0.34 Total• Supply Return (ft) (ft) Measured length of run -out 9 0 Measured length of trunk 20 0 Equivalent length of fittings 120 0 Total length 149 0 Total effective length 149 Friction Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.228 > 0.18 0.228 > 0.18 Return Ducts 0.228 > 0.18 0.228 > 0.18 Fitting Equivalent LengthDetails 4X=35,11 A=20,11 G=5,11 G=5, :11 G=5,1 A=35,11 G=5,11 G=5,11 G=5: Total EL=120 Return TotalEL=0 wrightsoft- 2018-Sep-1 8 15:0235 P Wt.NIB Mu. 4VwryGmp p RigIt-SuteO Universal 2018 18.0.19 RSU16877 Page 1 iktop\TEMP PRINTIM060 F1833A RHG Den- E.rup Caic= W8 House faces: E - GrG = OV VrIVI r411 EF3 = 110 CFM Fan AC PADS BY GC MIN SIZE aa'xaa' EFL1 = 50 CFM Fan EFL2 = 80 CFM Fan 39' SEPARATICN EFL3 =110 CFM Fan 15' OFF WALL V'PVCREFRIGUNECHASI S VTR = Vent to Roof, BY GC VTW = Vent to Wall DV = Dryer Vent RV = Range Vent — = Lineset Chase - - = Condensate OT = Thermostat 18/8 SRB = Small Reduction Box LRB = Large Reduction Box FBB = Feld Built Box