HomeMy WebLinkAboutBLOWER DOOR TEST CERTIFICATIONPlanning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982
Phone:772-462-2165 Fax:772-462-6443
BLOWER DOOR TEST FORM
on WqT
Q W,
RECEIVED
MAR % 8 2010
Permitting Depart," 'It
St. Lucie county
House Infiltration Test Certification SCANNED
Prescriptive and Performance Method BY
Date: 63-
Contractor:
Job l ddress:
Construction:
Permit #:
) New Construction — Complete ( - ) Existing — After Addition
;e Infiltration Te t Results SLC Climate Zone 2 - p
(50) _ � Test Date: ��^ L6 r�'q
me = : /s 7
(50) = CFM (50) x 60 / Volume = Mechanical Ventilation required less than 5 ACH
Ing results must be & ACH (50) or less ( Pass ( )Fall .
FBC, (Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 2 air changes per
hourlin Climate2o'ne 1, 2 and 3 air changes per hour in Climate Zones 3.through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals), Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.205 (3)(f), (g) or (1) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
cva., ncala+c11%,101
Where the air infiltration rate of a dwelling'unit is less than 5 air -changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall, be provided with whole -house mechanical ventilation in'accordarice with Section M1507.3.
Testine Company
Company Namg: �S ���,f/�G.S' address:
I hereby certify that the above House
requirements in a with Seca
Signature:
Printed Name:
License/Certification #:
results demonstrate compliance with FBC• Energy Conservation
1.2 Climate Zone 2.