Construction Materials Testing Services
FIELD AND LABORATORY REPORT COVER PAGE
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project: Oakland Lake Subdivision Lot 16
5332 Oakland Lake Circle, Fort Pierce, St. Lucie County, FL
As requested, Universal Engineering Sciences, Inc. (LIES) representative(s) performed construction materials testing and/or
field inspection services on the above project. Testing results and/or inspection observations are reported on the attached
sheets. The contents of this package are summarized below:
Scope of Work
Work Order No. Date Type of Report
102330-1 11/01/2018 In -Place Density Test Report w/Activity Record
We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact
the undersigned.
�UPPROVED ❑ APPROVED AS NOTED
0 REVISE & RESUBMIT 0 REJECTED/ RESUBMIT
❑ NOT REVIEWED ❑ FOR YOUR INFORMATION
Subinittafs-are reviewed for conformance with design Intent ��� NN`� ..F'.'`�h l�x/V
and general compliance with the Contract Documents only, ..CG .•' 10EN&
Nutations Do Not Authaite Changes to Contract Sum. �'
Approval, comments and/or corredtions does not relieve i$e NO. 48796
Contractor from compliance with the Contract Documents. Tie
Contractor is responsible for confirming and correlating al
quantities, dimensions, tolerances, clearances, fabrication �STATE.O
processes, techniques and sequences of construction
compatibility of ma •'
terials and methods, coordination of their �`��`•tN�lt?.•'�,;�����
work with other trades and subcontractors performance of
work in a safe and satisfactory manner an or full compliance
with the Con act uments. //f�lllflttttl�
T IEWED BY
A. B. N GROUP
Sincerely,
Universal Engineering Sciences, Inc.
Certificate of Authorization No. 00000549
Richard E.
Hoaglin, P.E.
2018.11.02
11:57:51-04'00'
Richard E. Hoaglin, P.E.
FLORIDA
Professional Engineer No. 48796
This item has been electronically signed and sealed by
Richard E. Hoaglin, P.E. using a Digital Signature. Printed
copies of this document are not considered signed and
sealed and the signature must be verified on any electronic
copies.
ICC Email: cbugg@nvrinc.com; elibrihi@nvrinc.com; Imhoff, Bryan IBIMHOFF@nvrinc.com]; jomcalli@nvrinc.com; rofingar@nvrinc.com; sign/seal MAIL to
ryan homes at 1777 Willows Square, Vero Beach, FL 32966
Revised May 2015
1
UES Project No: 0310.1700251.0029
UNIVERSAL
UES DOCS No:
UES Report No: 102330-1 ARC 110118
ENGINEERING SCIENCES On -Site Time (hrs): 1.00
Consultants In: Geotechnical Engineering • Environmental Sciences Lab Time (hrs): 0.00
Geophysical Services a Materials Testing • Threshold Inspection Travel Time (hrs): 0.50
Building Code Administration, Compliance Inspection & Plan Review Total Time (hrs): 1.50
;nue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Activity Record
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project: Oakland Lake Subdivision Lot 16
5332 Oakland Lake Circle, Fort Pierce, St. Lucie County, FL
Date of Activity: Thursday, 01 November, 2018
Technician: Cliff Cherrnav
As requested, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose of
earthwork testing for the House pad.
While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for House
pad. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet the
project compaction requirements of 95% of the maximum dry density per ASTM D-1557.
The Contractor was notified of the test results or a copy was left for their records.
UNIVERSAL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering - Environmental Sciences
Geophysical Services - Materials Testing - Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
UES Project No: 0310.1700251.0029
UES DOCS No:
UES Report No: 102330-1 DT 110118
In -Place Density Test Report
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project: Oakland Lake Subdivision Lot 16
5332 Oakland Lake Circle, Fort Pierce, St. Lucie County, FL
Area Tested: House pad
Type of Test: Field: ASTM D-6938 Nuclear Gauge Method Date of Test: 11/01/2018
Lab: ASTM D1557 Modified Proctor
Technician: Cliff Cherrnay
Requirements: 95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions
onlv and do not address the condition of the underivina soils below the tested depths.
Test
No.
Location of Test
Range
Depth
(inch)
Proctor
(2)
Field Dry
Density
(PCF)
Field
Moisture
%
%
Compaction
Comments
(3)
1
NMI test
0-1 ft
12.00
7424
110.4
11.0
96
A
2
N/E test
0-1 ft
12.00
7424
109.6
10.4
95
A
3
S/E test
0-1 ft
12.00
7424
108.8
10.1
95
A
4
SM/ test
0-1 ft
12.00
7424
111.7
11.2
97
A
Ref. Datum: 0 = Top of Final Grade
Maximum
Optimum
Proctor
Dry
Moisture
#
Density
Content
7424
115.0
12.0
(3) Comments Key
A. Compaction meets min. requirements
B. Compaction does not meet min. requirements
C. Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This test was performed without deviation from ASTM procedures.
This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.