HomeMy WebLinkAboutDESIGN LOAD COMPLIANCE CERTIFICATIONPlanning &Development Services Department RECEIVED • Building & Code Regulations Division . NOV 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 ?018 Permitting D Certification for Design Load Compliance St' Lucie coartment Project Name: CICCONE Project Address: 10701 S OCEAN DR LOT 669 Q� Permit #: 1810-0391 Occupancy Type: Construction Type: <16, Aw. . a i�r INSTRUCTIONS FOR USE:O • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the folloyiing: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida BUILDING Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): Enclosed Partially Enclosed X Open 3. Risk Category: _I X II III IV Exposure Category: B C X D 4. Design Wind Velocity 165 mph ASD X LRFD End Zone Width: �ft 5. Mean Roof Height 5'+/-DECK HEIGHT ft Roof Pitch: :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4: +60.6i-64.1 Zone 5: +70.1/-74'5 Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: 40 PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. . Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the ap li � I structural portions of the building codes currently adopted and enforced by St. Lucie �'�����l�d9� County. I also��i�t� �hqku�urpl elements depicted on these plans provide adequate resistance to the design forces specif ��;��®� ( �o`'•!s® F °° ;0 DANIEL PAUL RETHERFORD 72451 ;au ®;• No. 7��51 . p Print Name Cert # & Co. Cert Auth. B 2vv � '$ Signature, �Ia �P' 1402 HARTMAN ROAD, FT PIERCE, FL 34947 DSt2s ,., C "�"'.�- Company Name & Address Revised 07/25/2014