Loading...
HomeMy WebLinkAboutLETTER - LOAD COMPLIANCEW" , MARINE CONSTRUCTION SEAWALLS - DOCKS . BOATLIFTS • PILE DRIVING 10751 Orange Avenue I Fort Pierce, FL 34945 1 T 772.460.6928 1 F 772.460.6929 1 Lic. 5CC #131151026 I NOVEMBER 9TH, 2018 ST: LUCIE COUNTY BUILDING DIVISION 2300 VIRGINIA AVE FT PIERCE, FL 34982 RE: PERMIT # 1810-0392 ORR 10701 S OCEAN DR LOT 811 JENSEN BEACH, FL 34957 RECEIVED Nov 1 3 2018 Permitting DeFartment 5t. Lucle County TOI WHOM IT MAY CONCERN, PLEASE SEE ATTACHED REQUIRED CERTIFICATION FOR DESIGN LOAD COMPLIANCE AS REQUESTED. IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE FEEL FREE TO GIVE US A CALL. THANK YOU PECTIVELY SUBMITTED, WILCO CONSTRUCTION INC. Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: ORR Project Address: 10701 S OCEAN DR LOT 811 Permit #: 1810-0392 Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida BUILDING Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): Enclosed Partially Enclosed X Open 3. Risk Category: _I X II III IV Exposure Category: B C X D 4. Design Wind Velocity 165 mph ASD X LRFD End Zone Width: 1 ft 5. Mean Roof Height 5'+f-DECK HEIGHT ft Roof Pitch: :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4: +60.6/-64.1 Zone 5: +70'1/-74.5 Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: 40 PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: DANIEL PAUL RETHERFORD 72451 .� •+6�_7.e-', - r,�..�---•(fie' .w 10 Fre v is-ad'MI25'12014 n , Z': r,f��B�9teat�699,,. Print Name Cert # & Co. Cert Auth. 1402 HARTMAN ROAD, FT PIERCE, FL 34947 Company Name & Address