HomeMy WebLinkAboutproduct approvalFlorida Building Code Online Page 1 of 2
Submit Surcharge Stats & Facts c Publications contact us ; BCIS Site Map Links Search
Product Aooroval Menu > Product or Application Search > Application List > Application Detail
f FL # FL14850-R3
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
❑
Product Manufacturer
Custom Window Systems Inc.
Address/Phone/Email
1900 SW 44th Avenue
Ocala, FL 34474
(352) 368-6922 Ext 291
jlathrop@cws.cc
Authorized Signature Kevin Pine
kpine@cws.cc
Technical Representative ]ay Lathrop
Address/Phone/Emall 1900 SW 44th Ave
Ocala, FL 34474
(352)368-6922 Ext291
jlathrop@cws.cc
'! Quality Assurance Representative Arturo Monteverde
Address/Phone/Email 1900 SW 44th Ave
Ocala, FL 34474
(352)368-6922 Ext221
amonteverde@cws.cc
ll
r� g
i, T5 i t
.. x.:,.
OUNTY
BOC
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Lucas Turner
the Evaluation Report
Florida License PE-58201
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 07/21/2020
Validated By Steven M. Urich, PE
9 Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL14850 R3 COI EvalRepo rt641C.odf
Standard
AAMA/WDMA/CSA 101/I.S.2/A-440
ASTM E1886-05
ASTM E1996-05
PA TAS/201/202/203
Year
2005
2005
2005
1994
://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquH 1 FzfePouW7oGhY... 7/9/2019
Florida Building Code Online
Sections from the Code
11
I
1
Product Approval Method
Method 1 Option D
.i i' Date Submitted
09/28/2017
Date Validated
09/29/2017
Date Pending FBC Approval
10/02/2017
Date Approved
12/12/2017
Summary of Products
Page 2 of 2
FL #
Model, Number or Name
Description
14850.1
FD-8750, Impact.
FD-8750 French Door, SD-8700 Swing Door, SLT-8710
Sidelite, Impact.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL14850 R3 II CWS-641C.odf
Approved for use outside HVHZ: Yes
Verified By: Lucas Turner 58201
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: +70/-70
Evaluation Reports
Other: Large Missile French Door w/ Sidelights, Max. French
FL14850 R3 AE EvaiReoort641C.pdf
Door 6' x 8', Max. Single Door 3' x 8', Max. Sidelight 3' x 8',
Created by Independent Third Party: Yes
DP +/- 70 psf. Glass complies to ASTM E1300-04.
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Coovrioht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
click here .
Product Approval Accepts:
eCkecY. M
Credit Card
Safe
://www.floridabuilding.org/pr/pr_app_dtl.aspx?pararn=wGEVXQwtDquH 1 FzfePouW7oGhY... 7/9/2019
SWING DOOR & SIDELITE - LARGE MISSILE IMPACT
79" MAX. FRENCH DOOR WIDTH
37 5/8" MAX.
PANELWIDTH
26 5/8"
GLASS DLO
IN
17"
AAX.
!NIT
iEIGHT
C
95 3/16"
AX.
X
X
ANEL
HEIGHT
84 3/16"
GLASS
SEE
DLO
NOTE 4
•
A
11
FRENCH DOOR
TABLE OF CONTENTS
GENERAL NOTES & ELEVATIONS
1-3
GLAZING DETAILS....................................4
SECTION VIEWS....................................5-7
BOM............................................................8
EXTRUSIONS............................................19
ANCHOR SCHEDULE & NOTES ...............
10
INSTALLATION DETAILS ....................11-12
36 3/16" MAX.
SIDELITE WIDTH
33 5/8" MAX.
PANELWIDTH
22 5/8"
GLASS DLO
9
MAX.
UNIT
E E HEIG
C 94 5/8"
—FLUSH BOLT ON I 12 MAX.
INACTIVE PANEL I 0 PANEL
HEIGHT
B
11 83 5/8"
GLASS
DLO
I +
40" MAX. SINGLE'
+
DOOR WIDTH
D C
37 5/8" MAX.
12
PANEL WIDTH
SIDELITE
26 5/8"
A
GLASS DLO
81/2" NOTE:
I
HINGE SPACINGS ARE 8-1/2"
97"
I
F
I
FROM ENDS AND 20" MAX. 0. C.
20" FOR 81" TO 97" UNIT HEIGHT.
UMAX.NIT
I
1
95 3/16"
MAX.
X 1
B
PANEL B
HEIGHT
84 3/16"
GLASS
DLO
SEE
NOTE 4
8 1/2"
SINGLE DOOR
GENERAL NOTES:
(/W�VI���
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED
TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT
SYS4EPi5
EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AND
1900 SW 44TH AVE.
IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED
OCALA, FLORIDA 34474
IN ASTM E 1996 PER THE FBC.
W WW.CWS.CC
2. GLAZING OPTIONS: (SEE SHEET 4)
8700/10/50 PVC
3. CONFIGURATIONS: SINGLE OUTSWING, SINGLE OUTSWING
SWING DOOR
w/SIDELITE(S), FRENCH DOOR(S), FRENCH DOOR(S)
W/SIDELITE(S), SIDELITE NOT ATTACHED.
IMPACT
4. LOCK OPTIONS:
UP TO 68":
<
O
A. DOUBLE BORE w/TWO (2) INTERIOR FLUSH BOLTS.
F
0 w w o
HANDLE SET Q 36"
Z
w _j ❑ ¢®r;
B. MORTISE LOCK w/ TWO (2) INTERIOR FLUSH BOLTS.
w
o
zOZ- ccHANDLE
SETQ34"
Fa-w§ZO
C. MULTIPOINT (4 PT.)
SET @ 34"
Z
O
Z = �R ¢ Q w C)HANDLE
0 F- 0 6 < = � w
ABOVE 6'8":
Up
z _ t - Z U)
A. MULTIPOINT (5 PT.)
HANDLESETQ34"
Z
O O - Uj z U —
}
¢- u.WOOOz
5. DESIGN PRESSURE RATING:
:E< i-F-�z
o[ ¢ r } b 2 O cd
-NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND
w
O w U o w in w
GLASS TABLES ASTM E-1300-04e01/O9.
z nw. O -I m I-
O
-POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER
>_
w F- p w
INFILTRATION TEST PRESSURE AND GLASS TABLES
a
D ¢ a
ASTM E-1300-04e01/09.
6. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED
ov"tjpRE4Y�4.e
IN THE DESIGN OF THIS PRODUCT. SEE SHEETS 11-12 FOR ANCHOR
TG!��,
: ENS'-. Qy��
DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD
VQ•� ��
ANCHOR CALCULATIONS.
:• No 58201
7. PRODUCTS APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE
NOT REQUIRED.
fl= 'ate
%9 : STATE OF :'&V
8. ALL FRAMES ARE PROCESSED AND SCREWED TOGETHER. PANELS
%OT •.A' N.
ARE PROCESSED AND ASSEMBLED VIA TIE ROD.
.. E %
9. SERIES / MODEL DESIGNATION SD-6700, FD-8750, SLT-8710.
10. THE DESIGNATION X AND O STAND FOR THE FOLLOWING:
X = OPERABLE SASH, O = FIXED SASH
r
11. SECTION CALLOUTS APPLY TO ALL CONFIGURATIONS IN A SIMILAR
r
LOCATION.
9/22/2017
12. INTERIOR FLUSH BOLTS ON ACTIVE PANEL TO BE ENGAGED PRIOR TO
LUCAS A. TURNER, P.E.
SEVERE WEATHER.
FL PE # 58201
13. QUALIFIED ALTERNATIVE LOCKSET/DEADBOLT HARDWARE IS
1239 JABARA AVE.
NORTH PORT, FL 34288
GRADE 2 BY PAMEX AND DELANY.
PH. 941-380-1574
14. MAX. PANEL WIDTHS APPLY TO ALL CONFIGURATIONS, MULLED OR
SHEET DESCRIPTION:
NON -MULLED UNITS.
GENERAL NOTES AND
ELEVATIONS
TYPE
MAX. PANEL SIZE
DESIGN PRESSURE RATING
IMPACT RATING
SINGLE
37-5/8" x 95-3/16"
+/- 70 PSF
LARGE MISSILE IMPACT
FRENCH
SIDELITE
33-5/8" x 94-5/8"
LucasTurner
DRAWN BY:
DATE:
2017-09-22
ADE
09/08/11
13:18-04:00
DWG u:
REV.:
CWS-641
C
SCALE:
SHEET
1:35
1 OF 12
0
151 3/8" MAX. UNIT WIDTH
36 3/16" MAX.
79"
SIDELITE WIDTH
MAX. FRENCH DOOR WIDTH
33 5/8"
37 5/8" MAX.
PANEL WIDTH
PANEL W IDTH
17"
I
AAX.
1NIT
HEGHT
94
5/8"
95 3/
SIDELITE
Q
X
X
O
PANI
HEIGHT
HEIC
84 3/16"
SIDELITE
SEE
DOOR
GLASS
NOT1
JFLUSH835/8"
GLASS
DLO
SHT1
DLO
22 5/8"
GLASS DLO GLASS DLO
FRENCH DOOR w/SIDELITES
6"
IL
-IT
115 3/16" MAX. UNIT WIDTH
76 3/16" MAX. UNIT WIDTH
36 3/16" MAX.
79"
36 3/16" MAX.
40" MAX. SINGLE
SIDELITE WIDTH
MAX. FRENCH DOOR WIDTH
SIDELITE WIDTH
DOOR WIDTH
33 5/8" MAX.
37 5/8" MAX.
33 5/8" MAX.
37 5/8" MAX.
PANEL W IDTH
DOOR WIDTH
PANEL W IDTH
DOOR WIDTH
tl
97"
MAX.
MAX.M
UNIT
UNIT
HEIGHT
HEIGHT
•95
94
5/8"
94
5/8"
PANEL
SIDELITE
O
X
X
95 3/16"
SIDELITE
0
�(
HEIGHT
HEIGHT
PANEL
HEIGHT
83
5/8"
FLUSH
HEIGHT
SIDELITE
BOLT
ON
84 3/16"
83 5/8"
SIDELITESEE
84 3/16"
DOOR
GLASS
SEE
INACTIVE
GDLOSS
DLO
NOTE
PANEL
GLASS
NOTE
p oSS
SHT 1
DLO
SHT 1
9
22 5/6"
26 5/8"
22 5/8"
26 5/8"
GLASS DLO GLASS DLO
GLASS DLO GLASS DLO
SINGLE DOOR w/SIDELITE
FRENCH DOOR w/SIDLITE
WINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
www.cws.cc
8700/10/50 PVC
SWING DOOR
IMPACT
Z 3: < Z �
I TWO QH0O
Z WJ❑
o zoz "'
IL I-w�ZF
Z zm:E<mWO0-
O OI-O ¢=r=
U 0co I-z CLh(n IL
Z �--:Do-
I--u-2001Lz
�� COz
w LLw�cwnOwWw
EL d
m m wa- IL cr3:w�
No 58201
G Ot STATE OF
i
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
SHEET DESCRIPTION:
GENERAL NOTES AND
ELEVATIONS
DRAWN BY: DATE:
AIDE 09/08/11
DWG#: REV.:
CWS-641 C
SCALE: SHEET
1:35 2 OF 12
40" MAX. SINGLE
DOOR WIDTH
37 5/8" MAX.
PANEL WIDTH
26 5/8"
GLASS DLO
Bill
NOTE:
81/2" HINGE SPACINGS
—1 ARE 8-1/2" FROM
FLUSH
MAX.
UNIT
BOLT
21 5/16" ENDS AND 21-5/16"
MAX. O.C. UP TO
HEIGHT
81" UNIT HEIGHT.
79 3/16"
PANEL
p
X
HEIGHT
68 3/l6"
GLASS
DLO
•
SEE
NOTE4
SHT 1
8 1/2"
SINGLE DOOR
36 3/16" MAX. -
SIDELITE. W IDTH
33 5/8" MAX. —
PANEL W IDTH
Bill
MAX.
UNIT
HEIGHT
78
5/8"
•
SIDELITE
HEIGHT
67
5/8"
SIDELITE
GLASS
DLO
-1513/8" MAX UNIT WIDTH -
79" MAX. FRENCH DOOR WIDTH
- 37 5/8" MAX.
PANEL WIDTH
FLUSH
BOLT
O X ° X
SEE
NOTE 4
SHT 1
I-22 5/8"-i F- 26 5/8" -
GLASS DLO GLASS DLO
FRENCH DOOR w/SIDELITES
m
79" MAX. FRENCH DOOR WIDTH
37 5/8" MAX.
PANEL W IDTH
26 5/8"
GLASS DLO
YI
I
-FLUSH
A
BOLT
JNITAX.
NIT
1EIGHT
79 3/16"
PANEL
X
p
p X
HEIGHT
68 3/16"
SEE
GLASS
NOTE
DLO
SHT 1
79 3/16"
DOOR
PANEL
HEIGHT
68 3/16"
DOOR
GLASS
10:1A0Eel: IIlielMM
36 3/16" MAX. -
SIDELITE WIDTH
33 5/8" MAX. —
PANEL W IDTH
22 5/8"
GLASS DLO
8
MAX.
UNIT
HEIGHT
78 5/8"
PANEL
HEIGHT
67 5/8"
GLASS
N
SIDELITE
112 3/8" MAX. UNIT WIDTH
36 3116" MAX.
40" MAX.
.SIDELITE WIDTH
DOOR WIC
33 5/8" MAX.
37 5/8" MAX.
PANEL WIDTH
PANEL WIDTH
AAX.
FLUSH
NIT
JNIT
BOLT
iEIGHT
DOO
78
5/8"
PANT
SIDELITE
O
p
X
O
HEIG
HEIGHT
I
67 5/8"
SIDELITE
DOOR
DOOR
GLASS
Ll
GLASS
DLO
DLO -
I
22 5/8"
26 5/8"
GLASS ULO ULASS DLO
SINGLE DOOR w/SIDELITES
INGLE
rH
6"
1
IL
-IT
WINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
W W W.CW S.CC
8700/10/50 PVC
SWING DOOR
IMPACT
Q �: ¢z
owu Qw0
w zJQz Q
❑ a(n -}O
z z22¢¢wQQ
O OI-O ¢=Ftr
O OCHZwrU)IL
❑ z- -?I-❑0
z o0z' -ZO1)zZ)U—
Y ¢�owO=Oz
¢Q
z
�¢
w 20 wowow
V1w
a QJfnF
ca
O wHcc a. W=¢�
¢ _
m r a Ir aw.
9 STATE OF _ U
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
IEET DESCRIPTION:
GENERAL NOTES AND
ELEVATIONS
IAWN BY: DATE:
AIDE 09/08/11
VG >t: REV.:
CWS-641 C
:ALE: SHEET
1:35 3 OF 12
t
QUANEX
IG SPACE
1" OVERALL
3/16" TEMPERED
5/16" AIRSPACE
1/2" LAMINATED
3/16" ANNEALED
.105 DUPONT PVB INTERLAYER
—�E3/16" ANNEALED
GLASS TYPE A
AFLEX 552 or
PURFECT GLAZE "H"
3S BITE.
QUANEX
IG SPACE
GLASS TYPE B
1" OVERALL
3/16" TEMPERED
3/8" AIRSPACE
7/16" LAMINATED
3/16" ANNEALED
990 SENTRY GLASS IONOPLAST INTERLAYER
3/16" ANNEALED
AFLEX 552 or
PURFECT GLAZE "H"
iS BITE
QUANEX
IG SPACE
1" OVERALL
3/16" TEMPERED
5/16" AIRSPACE
1/2" LAMINATED
3/16" ANNEALED
.105 DUPONT PVB INTERLAYER
—�E3/16" ANNEALED
GLASS TYPE A
AFLEX 552 or
PURFECT GLAZE "H"
3S BITE.
QUANEX
IG SPACE
GLASS TYPE B
1" OVERALL
3/16" TEMPERED
3/8" AIRSPACE
7/16" LAMINATED
3/16" ANNEALED
990 SENTRY GLASS IONOPLAST INTERLAYER
3/16" ANNEALED
AFLEX 552 or
PURFECT GLAZE "H"
iS BITE
GLASS TYPES
MAX. UNIT
HEIGHT
SIDELITE
SINGLE
FRENCH
Bill
A
A
A
97"
B
B
B
WINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
www.cws.cc
8700/10/50 PVC
SWING DOOR
IMPACT
Q
1—
Z
z 3: ¢Z�:
❑ W O ¢ w 000 W
W J
ww
z
a ZO}O
z
O
Z=2¢QwpO
0r0 ¢=HOC
U
Ucn�zn-hrnCL
z
0 �—zZ)0—
0 0 c0 Z
y
Ir
¢how-=
2i < F--
w
O
00 cc ai0W row
LLma O -jmH
a0xwr
0
wr0
r a ¢3acl)
c
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
SHEET DESCRIPTION:
GLAZING DETAILS
DRAWN BY: DATE:
ADE 09/08/11
DWG#: REV.:
CWS-641 C
SETTING BLOCKS PER FBC 2411.3.3.1 SCALE: SHEET
1:1 4 OF 12
INTERIOR
SECTION VIEW A -A
INTERIOR
SECTION VIEW B-B
ALTERNATE 1
MORTISE LOCK w/ FLUSH BOLT
ITEMS NOT SHOWN FOR CLARITY:
10-12, 13, 15-17, 22, 43, 48, 54, 57-58
ITEMS NOT USED IN VERSION SHOWN:
2-3, 8-9, 15-16, 25-28, 30-34, 36-40, 43, 52-53, 60, 62, 65-66, 72, 76
aogom*
WINDOW SYSTEMS Ro
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
www.cws.cc
8700/10/50 PVC
SWING DOOR
IMPACT
z 3: `(z
U U.
oQw
w<) w cl0
¢z z=2mwpO Oro a=i-wp
w-aw(L
zO -zU- O�5UPOzH-L:RoOu-
¢Lw-20_
IW 00o-YJ- Cc co 0w92
S2La O -jUnr
a0 wr¢ wIr ocr>-
C F w wa"
zz to
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH.941-380-1574
SHEET DESCRIPTION:
SECTION VIEWS
SINGLE DOOR
DRAWN BY: DATE:
AIDE 09/08/11
DWG #: REV.:
CWS-641 C
SCALE: SHEET
12 5 OF 12
0
le
NOTE: VERTICAL SECTION SIMILAR
TO SINGLE DOOR, SEE SHEET 5
INTERIOR
SECTION VIEW C-C
ITEMS NOT SHOWN FOR CLARITY:
10-13, 15-17, 22, 26-28, 36-39, 43, 54, 57
ITEMS NOT USED IN VERSION SHOWN:
8-9, 15-16, 25, 40, 42, 45-46, 48, 52-53, 58, 60, 74, 76
WINDOW SYSTEMS I\�ZJ
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
www.cws.cc
8700/10/50 PVC
SWING DOOR
IMPACT
z
¢z
<Ip
F ow0 Pwoz?o
roa=¢z 2¢wp0 O OI-O ¢=If_
O Ucn F-ZaFcAD-
z p =-z�U-
ZOcnZ
H-u-2iOOLLz
r Q�:OwIr t f=O-
crQr�U-zcn
W u � c O w O W
Fr (nw OJmF-
D
0 w F- 0 a—
m w
o RS 6V �T ,i
G�y.4�0ENSF:7•Qti��
:• No 58201 '�15
�9 STATE OF
'4�� •< 0 R
'Its
Nn
z;;_,,
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
EET DESCRIPTION:
SECTION VIEWS
FRENCH DOOR
IAWN BY: DATE:
ADE 09/08/11
VG #: REV.:
CWS-641 C
:ALE: SHEET
1:2.5 6 OF 12
to
•
INTERIOR
ERII
SECTION VIEW E-E
SEALANT APPLIED TO
ADJOINING FACES
BYINSTALLER
#10 HEX WASHER HEAD TEK
JOINING DOOR FRAME TO SIDELITE.
6" FROM TOP AND BOTTOM
17" MAX. O.C.
5
1A,
SEALANT APPLIED TO
ko
52
#10-24 x 1-3/4" TYPE F
9
ADJOINING FACES
THRU HINGE INTO SIDELITE AT EACH HINGE.
BY INSTALLER
SEE SHEETS 1 & 3 FOR HINGE SPACING.
SECTION VIEW D-D
ITEMS NOT SHOWN FOR CLARITY:
10-11, 16, 22, 28, 43, 57
ITEMS NOT USED IN VERSION SHOWN:
1-3, 6-15, 17-18, 20-21, 23-24, 26-27, 30-39, 41, 44-46, 48-52, 54-56, 58-61, 63-71, 74-76
augom
WINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
W W W.CW S.CC
8700/10/50 PVC
SWING DOOR
IMPACT
z 3 Qz�
I-. owo awo1p
Z wJ❑
❑ zco 0??}O
Q 7
Z Z 2 2 Q Q w o o
O OF-O Q=I_x
n O OcF- zaPU)a-
0OW
Q �?w,200u-z
Q�OwFMO-
cr Q mm}wO-Z(n
Ill uo❑¢nc}0www
mw OJcnF-
G
a0 w1-O azw}
= w w It w
%```�.NpRE4V�T
GQ�?:��GEtVSF.• Q2�G
: No 58201 •:'�
4.
:9 STATE OF 41
z;7-11
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
EET DESCRIPTION:
SECTION VIEWS
ATTACHED SIDELITE
AWN BY: DATE:
ADE 09/08/11
IGW REV.:
CWS-641 C
ALE: SHEET
1:2 7 OF 12
PARTS LIST
PARTS LIST
�T//7R9j71�•
WINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
WWW.CWS.CC
ITEM
PART#
DESCRIPTION
MATERIAL
VENDOR
ITEM
PART#
DESCRIPTION
MATERIAL
VENDOR
1
H-1833
MAIN FRAME HEAD
ALUM
KEYMARK
51
P5131
GASKET, DOOR SILL, BACK
FOAM
HO PRODUCTS
2
H•1857
ASTRAGAL INACTIVE FD PVC
ALUM
KEYMARK
52
P5134
SCREW, #10 X 1-3/4" FLAT SQUARE TYPE F @ HINGE
FASTENAL
3
H-1858
ASTRAGAL ACTIVE FD PVC
ALUM
KEYMARK
53
P-5151
GASKET, SIDELITE
FOAM
HO PRODUCTS
4
14-186
REINFORCEMENT VERT
ALUM
KEYMARK
54
P5157
SCREW #10-24 x 1/2", FI Undercut PH, 18-8SS @ KEEPER
FASTENAL
55
P-5158
BOTTOM SEAL
RUBBER
TEAM
5
H-1861
REINFORCEMENT HORIZ
ALUM
KEYMARK
56
P-5172
WSTP, .370 X.187, TRI FIN, BLACK
ULTRAFAB
8700/10/50 PVC
SWING DOOR
IMPACT
6
I
MAIN FRAME SILL
ALUM
KEYMARK
7
-1878
I
MAINFRAME JAMB
ALUM
KEYMARK
57
P5174
SCREW #8 X 3/4" HEX WASHER HEAD, @ FRAME
FASTENAL
8
-1880
I-�1881
MAINFRAME SIDELITE DOOR
ALUM
KEYMARK
58
P5186
SCREW #8-32 x 1-1/4" PH,FL MS, SS @ PLUNGER
SS
FASTENAL
59
S-1783
THRESHOLD, HIGH RISE
ALUM
KEYMARK
9
I -1900
MAINFRAME SIDELITE JAMB, HEAD SILL
ALUM
KEYMARK
60
S-1784
INSERT, REINFORCEMENT
ALUM
KEYMARK
10
P-3039
SETNG BLOCK, 85 DUR. 1/8 X 1 X 2
TTI
RUBBER
FRANKLOWE
61
S-18
COVER, JAMB, ANCHOR
ALUM
KEYMARK
g
Z
w
o
LL z
O
p
¢
>
¢
w
a
O
a
< w O
w - on14
Z O z X65
¢ (n 3: > O
z w z � w p O
O r O j ¢ _ 1,- of
z - w z z FDo
O z 0z D O U
¢ O w Oz O z
m ¢ ~ U ~ z vi
O O Lu (n o wCo w
z = a 0
w r O Q. M >
a W LuU)
F d
11
SIKAFLEX 552 or PURFECT GLAZE "H"
SIKA - HENKEL
62
16 16
S-18
COVER, JAMBS, HEAD,SILL, SIDELITE
ALUM
KEYMARK
12
P-3503
SCREW #8 X 1/2" PH TRUSS SS ASTRAGAL CAP
FASTENAL
63
S-1817
DRIP CAP
ALUM
KEYMARK
13
P-3511
SCREW #8 x 5/8" SO. PAN TEK TIEROD BRKT
FASTENAL
64
S-1840
COVER, HEAD, ANCHOR
ALUM
KEYMARK
P-3587
SCREW #8 X 1" PH FLAT TEK ASTRAGAL, INSERT LOCK
FASTENAL
S-1849
INSERT, INACTIVE PNL, LOCK HARDWARE
KEYMARK
15
P-3767
SCREW #10 X 1" HEX HEAD TEK SIDELITE
FASTENAL
66
S-1859
COVER, ASTRAGAL, FD
ALUM
KEYMARK
16
P-4146
SCREW #8 X 3/4 PHIL FLAT SS TEK a SIDELITE SHIM
FASTENAL
67
S-1864
INSERT, FRONT, BTM ATTACH SILL
ALUM
KEYMARK
17
P-4278
FUZZY PAD, .200" x 1.250" W/ADHESIVE
ULTRAFAB
68
S-1865
INSERT, BACK, BTM ATTACH SILL
ALUM
KEYMARK
18
P-4522
#10 x 1 1/4" PH FLAT, SMS - HINGE PANEL
FASTENAL
69
S-1915
BASE, SWEEP
ALUM
KEYMARK
19
P-4774
WSTP BULB/LEAFS, PANEL
AMESBURY
70
S-1916
DRIP COVER, SWEEP
ALUM
KEYMARK
20
P-4790
FLUSH BOLT, ASSM TOP/BTM
SULLIVAN
71
S-6083
PANEL, TOP/BTM RAIL, SIDES - DOOR
PVC
MIKRON
21
P-4794
SCREW #8 x 5/8" SQ.FLAT TEK INSERTATTACH
FASTENAL
72
S-6083
PANEL, TOP/BTM RAIL, SIDES - SIDELITE
PVC
MIKRON
22
P-4802
ALL THREADED ROD TIE ROD
McMASTER
73
S-6084
GLAZING BEAD (1")
PVC
MIKRON
23
P-4807
HINGE GUIDE
HOPPE
74
H-1888
REINFORCEMENT, VERT., SINGLE DOOR
ALUM
KEYMARK
24
P-480BIP4809
HINGE SET
HOPPE
75
GLASS
SEE SHEET
25
P-4814
WSTP, .50X.750 FOLDED BULB SEAL SIDELITE
AMESBURY
76
H-1862
REINFORCEMENT, VERT.
ALUM
KEYMARK
p»ti,uoll�,,
PNOREK, Tf ,
�G
tiP;-��GEN$F, Ay
v. No 58201 ;� L
= * 7
'9•; STATE OF ;�+✓�
0A,
��i�S O I3 ..
""ONA„S""
40
X�
9/22/2017
STRIKE
77
P-4887
MORTISE LOCK
PADDOCK
27
P-4864
RHINO STRIKE,,
PLATE
PADDOCK
HEAD SILL
ALL FRAMES ARE MECHANICALLY FASTENED
•ALTERNATE APPROVED LOCKSETS:
PAMEX GRADE 2 LOCKSET AND DEADBOLT
28
P-4866
GUIDE, TIE ROD
NYLON
M&M
29
1 P-4871
ITIE ROD BRACKET
ZINC
SULLIVAN
30
P-4885
SHOOT BOLT, TOP
PADDOCK
31
P-4886
SHOOT BOLT BOTTOM
PADDOCK
32
P 4851
LOCKBAR, INACTIVE, 8 FT
PADDOCK
32
P 4884
LOCKBAR, MULTI -POINT, 5PT, 8 FT
PADDOCK
32
P-4901
LOCKBAR, MULTI -POINT, 4PT, 6-8 FT
PADDOCK
32
P-4902
LOCKBAR INACTIVE 6-8 FT
PADDOCK
33
P-4903
HANDLE SET ACTIVE
PADDOCK
34
P-4905
HANDLE SET, INACTIVE
PADDOCK
35
P-4913
WSTP .50X.50 FOLDED BULB SEAL DOOR
SCHELGEL
36
P-4917
CAP, ASTRAGAL, OUTSIDE
NYLON
M&M
37
P-4918
GUIDE, FLUSH BOLT, INACTIVE PNL
M&M
38
P-4922
COVER, INTERIOR, FLUSH BOLT
NYLON
M&M
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
39
P-4925
CAP, ASTRAGAL, INSIDE
NYLON
M&M
40
P-4926
SHIM, SIDELITE DOOR SHIPPING BLOCK
NYLON
M&M
41
P-4927
GUIDE FLUSH BOLT
NYLON
M&M
42
P-4930
SCREW #10 X 1-1/4" HEX HEAD TEK @ SIDELITE ATTACH
FASTENAL
43
P-4933
NUT, 3/8"-16 FLANGED W/ SERRATED LIP, SS, PANEL
McMASTER
SHEET DESCRIPTION:
BOM
44
P-4934
SCREW #12-24 X 1/2" PH FLAT MS HINGE
FASTENAL
45
P-4936
DOOR KNOB ACTIVE PANEL
DELANY
46
P-4937
DEADBOLT, ACTIVE PANEL
DELANY
47
P-4969
SCREW #10 X 2" REINF. ATTACH.
FASTENAL
DRAWN BY:
ADE
DATE:
09/08/11
48
P-4997
STRIKE DEADBOLT
PADDOCK
49
P-5127
SCREW 1112 X 2" PH PAN SMS, ANCHOR
FASTENAL
DWG
CWS-641
REV.:
C
50
P-5130
GASKET, DOOR SILL FRONT
FOAM
HO PRODUCTS
SCALE:
1:1
SHEET
8 OF 12
4 9116" —y
1 7/16"
1/16"
DOOR HEAD-1833
5
4 9/16"
L 1/16"
DOOR SILL-1878
PVC DOOR PANEL -6083
9i
4f
j- 4 9/16" 1 1/2"
7 � ❑ 5 4
1 9l16" U
1/16" 2 15/16" 1/16"
DOOR JAMB-1880
4 9116"
���'{[L�II Hr
21/2"U"
SIDELITE-1881
4 9/16"
s
21/16"
IL SIDELITE-19900
NOTE: ALL EXTRUSIONS ARE 6063-T6 ALUMINUM
REINFORCEMENT -1861
1 1/2"
O4
2 15116"11
L� I
1/16"
REINFORCEMENT-1860
66
1/16"
ASTRAGAL COVER-1859
REINFORCEMENT -1857
REINFORCEMENT -1858
215116" II
REINFORCEMENT -1862
1 3/4" �{
65
1/8„
INSERT, INACTIVE PNL -1849
59
1 3116"
THRESHOLD -1783
2 1/4" --{
1/4" I 61
1/16"
FRAME COVER -1806
r-23/S"�
3/4" 62
1/16"
1
SIDELITE COVER -1816
1 15/16"
3i=
/4"
69
1116"
BASE SWEEP - 1915
T--;z 1 9/16"
68
13116"
i
INSERT. BACK -1865
9/16"
T— 67
11/116" 1/16"
INSERT, FRONT -1864
518"
64
9/16"
1116"
HEAD COVER -1840
s/a"
3/8° 60
T
FILLER -1784
1ffi—
PVC GLAZING BEAD - 6084
63
5I"
1/16"
DRIP CAP -1817
3/4"
70
13116"
DRIPCOVER OVER-1916
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
W W W.CWS.CC
8700/10/50 PVC
SWING DOOR
IMPACT
Q Z 3: Qz3:
O QWO
Z W_1O
o zw0->-0i
D. Hw�zt-�gx
Z z 2 2 Q X W 0 0
Z O 0 --Do-
Q r-?LLnoowZ
Y Q�Ow-20-
r �Q F-VI_Z'd
W ,W�D-'wowow
wWW QJ(0-
Q' =�0_' W Lufn
o a C�a
Z�
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
EXTRUSIONS
:AWN BY: DATE:
AIDE 09/08/11
VG #: REV.:
CWS-641 C
ALE: SHEET
1:2 9 OF 12
ANCHOR @ Mil
6" MAX. (TYP.)
6" MAX. (TYP.)
17"
MAX. O.C.
(TYP.)
AETAL
SEE NOTE 2
ANCHOR @ MIDSPAN (TYP.)
6" MAX. (TYP.)
6" MAX. (TYP.)
17" MAX
INSTALLATION O.C. (TYP)
ANCHOR (TYP.)
SIDELITE DOOR SIDELITE
ANCHOR LAYOUT - (FLANGE)
(T7d 2" (TYP.)"WOI
X
1
X
U
u
v
ii
SIDELITE DOOR DOOR SIDELITE
ANCHOR LAYOUT - (FLANGE)
*CIRCLED ANCHOR LOCATIONS REQ'D ONLY IN WOOD AND METAL INSTALLATIONS. DO NOT INSTALL THESE ANCHORS INTO MASONRY.
v
)DIMETAL
- SEE NOTE 2
---INSTALLATION
ANCHOR (TYP.)
NOTES:
1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD.
2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS
SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED.
3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 11.
4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD
MUST BE PROTECTED TO PREVENT REACTION.
5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE
MINIMUM SPECIFIED IN TABLE 1, SHEET 11.
6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE.
INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE.
INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF I BUCKS BETWEEN THE PRODUCT AND SUBSTRATE.
7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 4" FOR MASONRY, 2-3/16" FOR HINGES (ALL SUBSTRATES), 1" FOR WOOD AND METAL.
8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE.
SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 11. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED.
9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS:
FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMAANDMA 250(BOX WINDOWS), FMA/AAMA/WDMA 300(EXTERIOR DOORS)
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
W W W.CWS.CC
8700/10/50 PVC
SWING DOOR
IMPACT
z 3: Qz3:
z ww0 Qw0
zoz0
O vi}0�
LL F--w�zl-3:
z z=� Q W O 0
z p U` O Z?? O-
Q H.?'noOU-z
>_ Q� w-=O_
2 I`_ > ~ Zvi
W 0LL 0 OWV)W
2' Z�w 0�V_1F-
CL 0 WF0 o_=,}
a m a W3:aw
zz '!
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
SHEET DESCRIPTION:
ANCHOR SCHEDULE AND
NOTES
AIDE 09/08/11
!G#: REV.:
CWS-641 C
ALE: SHEET
1:8 10DF 12
TYPICAL HEAD ANCHORAGE
MIN. EDGE DIST.
INTERIOR
SEE TABLE 1
CONTINOUS DBL 1/4" BEADS OF SEALANT
AROUND PERIMETER AT ALL INDICATED
SUBSTRATE BY OTHERS
POINTS BETWEEN FRAME AND SUBSTRATE
SEE TABLE 1 MIN. EMBEDMENT
BY INSTALLER.
SEE TABLE 1
INSTALLATION ANCHOR
SEE TABLE 1
PERIMETER SEALANT O I I 11/4"
MAX. SHIM
BY INSTALLER La L—I
INSIDE AND OUT
INTERIOR
CONTINOUS DBL 1/4" BEADS OF SEALANT
INSTALLATION ANCHOR HINGE ANCHOR
SEE TABLE 1
AROUND PERIMETER AT ALL INDICATED
SEE TABLE 1
POINTS BETWEEN FRAME AND SUBSTRATE
BY INSTALLER.
PERIMETER SEALANT BY INSTALLER
INSIDE AND OUT
PERIMETER SEALANT
BY INSTALLER14 SEE TABLEE BY OTHERS
INSIDE AND OUT
SUBSTRATE BY OTHERS
SEE TABLE 1
MIN. EMBEDMENT
SEE TABLE 1
'r 1 MIN. EDGE DIST.
A VERTICAL SECTION SEE TABLE 1
11 TYPICAL SILL ANCHORAGE
TABLE 1: APPROVED INSTALLATION FASTENERS
SUBSTRATETYPE
ANCHORTYPE
MIN. EMBEDMENT
MIN. EDGE DIST.
CONCRETE (2.85 KSI MIN.)
1/4" ELCO ULTRACON
1-3/4"
2-1/2"
HOLLOW OR GROUT -FILLED CMU (ASTM C-90)
1/4" ELCO ULTRACON
1-1/4"
2-1/2"
2XMIN. SOUTHERN PINE (G=0.55)
1/4" ELCO ULTRACON
1-3/8"
7/9"
2XMIN. SOUTHERN PINE (G=0.55)
#12 WOOD SCREW
1-318"
7/8"
16 GAUGE (0.060") MIN.
STEEL STUD (33 KSI YIELD MIN)
#12-14 HILTI KWIK-FLEX OR ITN/
TEKS SELF -DRILLING SCREW
FULL THREAD
THRU 0.060"
1/2"
1/8" ALUM. (6063-T5 MIN.) OR
1/8" STEEL (33 KSI MIN.)
#12 GRADE 5 SELF -TAPPING /
DRILLING SCREW
FULL THREAD
THRU 0.126"
1/2"
HINGE ANCHORS INTO CONCRETE (2.85 KSI MIN.)
3/16" ELCO ULTRACON
1-3/4"
2-1/2"
HINGE ANCHORS INTO HOLLOW OR GROUT -FILLED
CMU (ASTM C-90)
3/16" ELCO ULTRACON
1-1,/4"
2-1/2"
HINGE ANCHORS INTO 2XMIN. SOUTHERN
PINE (G=0.55)
#10 WOOD SCREW
1-3/8"
7/8"
HINGE ANCHORS INTO 16 GAUGE (0.060") MIN.
STEEL STUD (33 KSI YIELD MIN)
#10-16 HILTI KWIK-FLEXOR ITW
TEKS SELF -DRILLING SCREW
FULL THREAD
THRU 0.060"
1/2„
HINGE ANCHORS 1/8" ALUM. (6063-T5 MIN.) OR
1/8" STEEL (33 KSI MIN.)
#10 GRADE 5 SELF -TAPPING /
DRILLING SCREW
FULL THREAD
THRU 0.125"
1/2„
1/4" MAX. SHIM
V- IYIYAY(.4W/UU(Y•�/'�-
MIN. EMBEDMENT
WINDOW SYSTEMS IILL((��I� HILL/%��(
SEE TABLE 1
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
WWW.CWS.CC
MIN. EDGE DIST.
SEE TABLE 1
8700/10/50 PVC
SWING DOOR
IMPACT
z 3 az�
Q oW0 W
z
o
LL
Z
O
WJ❑
zW;Emom
>-0M _
HW�z Ii
Z=2<mW50
O♦-C! U ¢=I_-w
HINGE MIN. EDGE DIST.
0
z � Z? H 7
SEE TABLE I
Q
-ZI=Ui. Zp00LLZ.
>
¢SOW-=O-
Q
a< �U~Z'6
HINGE MIN. EMBEDMENT
w
OLL U) of co o w w
SEE TABLE I
BE
0
?=a 0:0-rn
W1-O a = �}
a 3:
�\
B 1 HORIZONTAL
SECTION
JAMB / HINGE ANCHORAGE
a
a
11 TYPICAL
2 13/16„
ANCHORSTHRU
HINGE (TYP.)
2151E MAX.
SEE NOTE
NOTE:
HINGE SPACINGS ARE:
8-1/2" FROM ENDS
21-5/16" MAX. O.C. FOR UP TO 81" UNIT HEIGHT
20" MAX. O.C. FOR OVER 81"UNIT HEIGHT,
rcrc��
HINGE LAYOUT
1:30
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH.941-380-1574
1EET DESCRIPTION:
INSTALLATION DETAILS
DOOR
RAWN BY: DATE:
ADE 09/08/11
NG#: REV.:
CWS-841 C
'ALE: SHEET
1:2 11OF 12
TYPICAL HEAD ANCHORAGE
MIN. EDGE DIST.
SEE TABLE 1, SHT 11
SUBSTRATE BY OTHERS
SEE TABLE 1, SHT 11
MIN. EMBEDMENT
SEE TABLE 1, SHT 11
PERIMETER SEALANT
1/4" MAX. SHIM
BY INSTALLER
INSIDE AND OUT
INTERIOR
CONTINOUS DBL 1/4" BEADS OF SEALANT
AROUND PERIMETER AT ALL INDICATED
INSTALLATION ANCHOR
POINTS BETWEEN FRAME AND SUBSTRATE
SEE TABLE 1, SHT 11
BY INSTALLER.
PERIMETER SEALANT
BYINSTALLER
INSIDE AND OUT Land
MIN. EMBEDMENT
SEE TABLE 1, SHT 11
SUBSTRATE BY OTHERS
SEE TABLE 1, SHT 11
MIN. EDGE DIST.
SEE TABLE 1. SHT 11
C VERTICAL SECTION
12 TYPICAL SILL ANCHORAGE
INTERIOR
CONTINOUS DBL 1/4" BEADS OF SEALANT
AROUND PERIMETER AT ALL INDICATED
POINTS BETWEEN FRAME AND SUBSTRATE
BY INSTALLER.
INSTALLATION ANCHOR
SEE TABLE 1, SHT 11
PERIMETER SEALANT BY INSTALLER
INSIDE AND OUT
SUBSTRATE BY OTHERS
SEE TABLE 1, SHT 11 x _ x w�' U
/ u 1 HORIZONTAL SECTION a F- CL X a
12 TYPICAL JAMB ANCHORAGE
1/4" MAX. SHIM
Owsibm'L/df/d
MIN. EMBEDMENT
WINDOW SYSTEMS LF/�j�jLJ�
SEE TABLE 1, SHT 11
1900 SW 44TH AVE.
—
FLORIDA 34474
/
WWW.
WWW.CWS.CC
EDGE
/MIN.
SEE TABLED1, SHT 11
8700/10/50 PVC
SWING DOOR
IMPACT
/
t-
Z
z 3: ¢z3:
ow0 WW
WHO<177
U
It
ozw
w
� >-0w
Hwzi--3:gx
/
z
O
U
z=2¢cfwp0
OF-O ¢=Fw
0W
Z
za—PU)n-
o
Ufn-:)0-
~-u-mo wZ
1
a3:oWpmo-
< Q> I- Z'6
xofW 0�afu)o
U.WUW
W 0Jwl-
aam-
0
w1-0 }
40
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
HEET DESCRIPTION:
INSTALLATION DETAILS
SIDELITE
RAWN BY: DATE:
ADE 09/08/11
NG #: REV.:
CWS-641 C
-ALE:SHEET
1:2 123F 12