Loading...
HomeMy WebLinkAboutproduct app,. r _ a BCIS Home Log In User Registration Hot Topics I Submit Surcharge ; Stats & Facts I Publications Contact Us BCIS Site Map Links Search !� Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed j the Evaluation Report I Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date I Validated By Certificate of Independence FL17022-R7 Revision 2017 Approved R6CEIVED JUL 08 2019 ST. Lucie County, Permitting Py T 08/18/2017v. date reapply 06/21/17 n=V1C;tfVl7=® Q'-®M Extreme Metal Fabricators, LLC 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 flvalidation@yahoo.com Richard McKuhen flvalidation@yahoo.com Richard McKuhen 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 richard@emfab.net Roofing Metal Roofing STe LUCIE COUNTY OCC Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report - Hardcopy Received LOCKE BOWDEN PE-49704 Keystone Certifications, Inc. 04/22/2024 Zachary R. Priest, P.E. O Validation Checklist - Hardcopy Received FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.odf Referenced Standard and Year (of Standard) Standard TAS 125 UL 1897 UL 580 Equivalence of Product Standards Certified By Sections from the Code Year 2003 2012 2006 Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated 06/25/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 Summa roducts FL # Model, Number or Name ----,Description 17022.1 -1 - "5V Crimp" (R6) 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, RE, 49704 Imp Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.pdf assembly in compliance with the installation method listed in Created by Independent Third Party: Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.2 12 - "5V Crimp" (116) I0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ Table A Other: Refer to evaluation report for conditions.Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.3 13 - "1.5" Mechanical Seam" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.4 14 - "1.5" Mechanical Seam" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.5 1 5 - "1 in. Nail Strip" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with Installation Instructions FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odf Created by Independent Third Party: Yes 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Installation Instructions FL17022 R7 II FL 17022.3 1.5 MECHANICAL seam 24ga ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.3 1.5 MECHANICAL seam 24na ssr.odf Created by Independent Third Party: Yes 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with clips and fasteners. Installation Instructions FL17022 R7 II FL 17022.4 MECHANCIAL SEAM ALUMINUM ssr.Ddf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL17022.4_MECHANCIALSEAM ALUMINUM ssrpdf Created by Independent Third Party: Yes 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Installation Instructions FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssrpdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.-ndf Created by Independent Third Party: Yes Fig the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.6 16 - "1 in. Nail Strip" (115) 1" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to attached to 15/32" plywood or Wood Deck with fasteners, Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. Installation Instructions FL17022 R7 II FL 17022.E 1.0 NAIL STRIP 0,032 ALUM ssr.Ddf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.6 1.0_NAIL STRIP 0.032 ALUM ssr.odf Created by Independent Third Party: Yes 17022.7 7 - "1.5 in. Nail Strip" (R5) 1.5" rib height, 19" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.8 18 - "EMAX Rib" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. Installation Instructions FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.7. 1_5 Nail Strio 26GA ssr.Ddf Created by Independent Third Party: Yes 29 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 II FL 177022.8 EMAX Rib ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL_177022.8 EMAX Rib sSnodf Created by Independent Third Party: Yes 17022.9 19 - "PBR MAX" (RS) 115/32" plywoo26 gauge ld lapped wood deck with exposed fasteners. attached to Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17N2.9 PBR RIB ssr.Ddf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.9 PBR RIB ssr.Ddf limitations of use. Install the assembly in compliance with Created by Independent Third Party: Yes the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your a -mall address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® t_Cteck M Credit• Safe 77CI 7t E79t I C S, Palm City, FL 34990 Compliant with Florida Building Code 2017 (61h ed.) - Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. See Fastener attachment specifications above install Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING 26" O.C. 16" o.c. 8" O.C. 6" o.c. FASTENER SPACING (ALONG_ Panel width) 12" ox. 12" O.C. 12" o.c. 12" O.C. FASTENER SIZE #9 #10 #10 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527 UL 580-06 & 1897-041 Test . Report D05893.01-450-18 Os/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-1? *Design pressure margin of safety 2:1 JI ioll iirrlr Locke Bowden, P.E. does not have, not will acquire a financial intt*'4tij afcq acturing or distributing products Under this evaluation. - • Locke Bowden, P.E. is not owned, operated, or controlled by any cos1parNombbil urea, or distributing products under this report. d . • J 1 •+ S rT4 �r41 .�3 ,% r�oo hl ••F�li f?���i• �ti ��. • l�.��•1�, ,• . • • + {,�.%tip• %:"'ANAL f1 FL17022.1 *Crimp (26GA Steel), 24" Wide Ro Panel -Details Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. I Fasteners - #9 x 1-1/2" Min. or #10 X 1-1/2" Min. per Table A" for Row 5-V Crimp Roof Panel 15/32" or greater Plywood, or Wood plank 24- _ 12" 318" Panel Overlap ` ` OPTIONAL STRIATIONS Panel Profile Nominal12" _ Nominal12" O.C. O.C. Fasten 9 x -1/2" Min. or #10 X 1-1/2" Min. per -fable "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Width Refer to Table "A" for Spacing Along Panel Length Deck-15/32" or greater Plywood, or - Wood plank