HomeMy WebLinkAboutprod16/20/22 kW INCLUDES: • True Power`' Electrical Technology • Two Line LCD Multilingual Digital Evolution'' Controller (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. • Electronic Governor • System Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure • Flexible Fuel Line Connector ♦ Direct -To -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation • 5 Year Limited Warranty • Capability to be installed within 18" (457 mm) of a building* FEATURES GENERACW00111111111111 GUARDIAN° SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating Models G007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz Models G007043-0, G007042-0 (Aluminum - Bisque) - 22 kW 60 Hz O - INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's 0 success in providing the most reliable generators possible. Generac's G-Farce engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER- ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed WAC systems. OLISTED us QUID Note: CUL certification only applies to unbundled units and units packaged with pre -wired switches. Units packaged with the Smart Switch are UL certified in the *Only it located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all.Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%. SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are V PROTOTYPE TESTED V NEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this V SYSTEM TORSIONAL TESTED v' MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. w GENERAC �''•3� ,d�A " � Mobile PROMISE i GENERAC 16/20/22 kW features and benefits Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder wallsand plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur- ing up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to ±1% prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution'" Controls • Auto/Manual/Off illuminated buttons Selects the operating made and provides easy, at -a -glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- ically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from,a building. Installation System • 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. 0 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. 16/20/22 kW GENERAC specifications Generator Model G007035-0, G007036-0, G007038-0, G007039.0 11007042-0, G007043-0 G007037-0 (16 kW) (20 kW) (22 kMo Rated Ma)dmum Continuous Power Capacity (NG) 16,000 Watts" 18,000 Waits` 19,500 Rat cV� ��.�'r, �- � �� � ,�>, � � ?.,.� �" . � r 3 � � �, -, •..�� ,. .- �.:: _ 240` Rated Madmum Continuous Load Current —240 Volts (LP/NG) 66.6/66.6 83.3175 91.6/81.3 T' , ;,i'(dFR�1i)d Main Line Circuit Breaker 70 Amp 100 Amp 100 Amp q a' Phew .,. e.% •RM�;-..1% J fx r. 3 f d e� f ..' .s`q� � mrC '.. "'� -�+ .;3:�:, �13z A . 9 {µ'^ YrF� t`;^,9'.. Number of Rotor Poles 2 2 2 A , equelray 5 _ 6f ,7.biz Q Power Factor 1.0 1.0 1.0 Unit Weight (Ib/kg) 406/186 448/203 466/211 Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load" 66 fifi 6T Exercise duration 5 min 5 min 5 min Engine Type of Engine GENERAC G-Force 1000 Series GENERAC G-Farce 1000 Series GENERAC G-Force 1000 Series Displacement 999 cc 999 cc 999 cc ,.. �,-: � �m hum w,. ast.triln[eaye y�r ��s, r Valve Arrangement Overhead Valve Overhead Valve Overhead Valve lrstc -. 'Solidsfatew:M Hato :° a ,-sfate:wl;, a , ro. ' `M-: o id=sfate:w tleto ' Governor System Electronic Electronic Electronic E Starter 12 Vdc 12 Vdc Operating rpm 3,600 3,60D 3,600 Note: Fuel pipe mast be sized for full load. Required fuel pressure to generator fuel inlet atall load ranges - 3.5-7° water column (7-13 mm mercury) for natural gas,10-12" water column (19-22 mm mercury) for LP gas. Far 8tu content, multiply ft3/hr x 2500 (LP) or f13/hr x 1000 (M. For Megajoule content, multiply m3A1r x 93.15 (LP) or m3/hr x 37 26 (NG) Controls 2-Line Plain Text Multilingual LCD Display Simple user interface for ease of operation. manual Start with starter control, unit stays on. if utility fails, transfer to load takes place. Obi ',7 W ; to lend' f'"owar ;reriaoved.;Groniratond' 01 `a�ratit r, ,, Ready to Run/Maintenance Messages Standard Programmable start Future Set Capable Standard (programmable Cyclic cranking:16 sec on, 7 rest (90 sec "Sound levels are takentrom the Nord of the generator. Sound levels taken hornothersides of Ore generatormay be higherdepend'ng on installation pararneters, Bating definitions -Standby: Applicable for supplying ernonteocY We'or br the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514. IS03046 and DIN6271). ' Midmum kilovolt amps and aerent are subject to and [idled by such factors as luel Btidmega)oule cantcat,amhfeNtemperahue,al6lrrde,engimpowerandcondi m,etc. Maodmurn power decreasesaW3.5 percent for each 1,000 feet (304.8 motors) abovasea [awl; and also will decrease about 1 percent for each 6 T (10 T) above 16 'C (60 *F). 16/20/22 W Limited Circuits Switch Features • 16 circuits. • Electrically operated, mechanically -held contacts for fast, positive connections • Rated for all classes of load,100% equipment rated, both inductive and resistive. • 2 pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 1"standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effec- tive install. Dimensions 200 Amps 120/240,1 o Open Transition Service Rated Height Width Depth H1 H2 W1 W2 in 27.24 30.0 11.4 13.5 7.09 mm 692.0 1 762.4 289.0 343.0 180.0 Note: The 50 amp switch is flush mountable. H1 and W1 refer to mounting hole spacing. H2 and W2 are cover dimensions. H3 and W3 are the enclosure dimensions without cover. Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 210-#14 2J0-#14 Service Rated Smart Switch Features • Includes Digital Power Management Technology standard (DPM). • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to four more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both inductive and resis- tive. • Up to four more large (120/240 VAC) loads can be managed when used in con- junction with 50 amp Power Management Modules (PMM**). • 2 pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. Dimensions 200 Amps 120/240,1 o Open Transition Service Rated Height H2 H1 Wt Width W2 Depth in 27.24 30.0 11.4 13.5 7.09 mm i 692.0 762.4 289.0 343.0 180.0 GENERAC® switch options Model G007036-0 (16kW) Current Rating (Amps) 100 V'llag`',tiaN Utility Voltage Monitor (Fixed)' -Pick-up 80% -Dropout 65% Exerciser bi-weekly for 12 minutes'f Standard Total of Pre -wired Circuits 16 No. 15A120V 5 No. 20 A 120 V 5 No. 20 A 240 V 1 No. 30 A 240 V No.40 A 240 V 1 No. 50 A 240 V 1 Circuit Breaker Protected Available RMS Symmetrical 10,000 Fault Current @ 250 Volts *function of Evolution Controller Exercise can be set to weekly or monthly DEPTH — Model G007037-0 (16 kM/0007039-0 (20 kW)/ G007043 0 (22 kW) fVe .ot Eroles F— 0 x. ff" Current Rating (Amps) 200 ,Yt .00iaOo',R� it g 'Aft Utility Voltage Monitor (Fixed)* -Pick-up 60% -Dropout 65% I�tttrdoUkt M: `z«,aA"rox 1.3G Exerciser weekly for 12 minutes* Standard Enclosure Type NEMAML 3R GircuitEieak, a„rPfsded Lug Range 250 MGM - #6 *Function of Evolution Controller DEPTH 16/20/22 kW GENERAC available accessories Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac G006463A Mobile Link`" cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or text message when a change in the generator's status occurs. Available in the U.S. only. G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact@). 6007101-0 Battery Pad Warmer The pad warmer rests under the battery. Recommended for use 4 the temperature regularly falls below 0°F. (Not necessary for use with AGM -style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter. Recommended for use If the temperature regularly falls below 0°F. G007103-0 Breather Wanner The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load Contact Kit you may not need. Not compatible with 50 amp pre -wired switches. Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a G007027-0 - Bisque (Standard on 22 kW) sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from 6005703-0 - Bisque Paint Kit future corrosion. The paint kit includes the necessary paint to property maintain or touch-up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. G006873-0 Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its (50 Amps) power management capabilities. it provides additional power management flexibility notfound in any other power management system. dimensions & UPCs Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. LEFT BIDE VIEW 14alatm FRONTVIEW Model UPC G007035-0 696471070354 G007036-0 696471070361 G007037-0 696471070378 G007038-0 696471070385 G007039-0 696471070392 G007042-0 696471070422 G007043-0 696471070439 GENERAC® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • genert;.com 02016 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. 100000001 94-C 08,118116 AMERICAST GENE -,too", (ON -GRADE GENERATOR S LOG, PF0 ISOMETRIC V{E� PAD DIMENSION& OENERATORTABI r! GENERATORUNIT By. SEPARATE SUBMITTAL (SEE kFIEDULEFOR II 'MINIMUMWEIUMT 5 4 - L EN GT H­­­---4 PLAN VERY CONCRETE PAD�•---( ROAD MESH L` MIN IV GROUND ,;-,, R. CONCRETE PAD CONS ONLY) WTN wj�.W. OR N vHr, msK EXPOSURE WT RISK' � f:XXPOSUAElEXFI I WK I EXPOSURE(EXPI: .COUNTY C - 0 . . 11 . I I" c 114 rv, P. BEACH J50 mm ITO kmiS9.09 W147.444VI 180 MPH 43.Wl'iS3_l9Pf .. .. P. 5pil 1700AP14139.09Pd 47A14P0129OMPH 43.83"153.19Pif 146.80WIS6.80PO . MIAWDADE: -- - -PH 141.43 PAMM P01 386 MPH BOND CAPAC=rrY Wove unufl, umtii vveco U, ,ARE OWNWras IEXP G-cossnaoism low 12sm, 48.00• 2900- 387 lbs' 4IA3Prf C 17S MPH &0 LSS MPH G­Yu00WZ&0M34 24aY ��47."Psf _... P' EXP C 196 MPH & 0 L56 MPH GiA-6459,646L6462 AEAH:25:60" 1 4800' 29M " Sh n6 C.44 Pir Se_. DD6721 IS MY i 25.W � Z9DD" 443 its 47.4-4 Pd C, 21il­ .00" 48.00 mor" 455 lb, 47M Pif dG._005974&D0SS$6�17­KW !25.OD 48M '29-W" 421 fb4 47,U Vif 20 W 1 25.00 - 48.00 -b.W' !Elll*_. 4 7 " Ps1, G.er.006729&D(16730 20 Kwnil) - maviDm g' ffi SW . 47." P%f 6L;iVaC 006SS1a 006S52 22 !WL J�.W' 49,00 ` 29.03" 626 lb, 47.44'PV K. I M.14MVIORES- 24,20MV 76DID! 48.60' �zdm�'. 'WAS i 47j44 pgf' GE40323GE&403UGE 13 MV 35.4)D" 39.40"! 39.0Cr" 540 lb. 39. 0 1 EXPCI70MPH&DL56MPH GED40922sku, 1 3 48-60 4P INS A3.93 Ptf. . EXP C 180 MPH & 0 L56 MPH GE04037817KIN i K�V� CID .. 48.00"' 3630" 43416s 13.83 Psf Gt40330GEA46331GF n6P&5td Zb W 10 3LM " 4K 00 " 33,0!)- 32I0.L MM", 43.23Nf- ofim & 5�ft" W302=2 12 1 111. 1 Im.. .71'. aL43 P12 10.1175 MPH & 0 111 MPH oftp & 3u.tm QT�2 04 akwi 5- -n-_ I I IBM, 3317V 49 2n 49.00- -A.-, �Al alm!­ SUK 4 S - 775 �Kf ixpclwmpR&OL%Mpm SOW 5 SU.ft- 040305-2 20 JKW 33• Agao 5701bi .44.0Gftf 6-tat 7035;2036d037: 16M 26.00 48.00 �1� 47.44 44 PIl IMMPH&OL56MPH G...,0070389007M W 20 25.W'* 48.00' �n.W' a ", 4:1 P � - 4&W �29 45616, 47.44 Psi GENERATOR MOUNTING.CONFIGURATION: rENFgATaaArrAcmmENTvse Wfm ORSolml=p o, IiN= To iSte GINE=E;6V GENERATopt ZE CONCRErE PAD '4CHEDOLEFOR! E.M=w W ED), ConCREM mo 6,000 PSI LIGNI'VEIGHT 32- WTbTH 4 W LENGTH Z;�MWANtE D 2. X WSTAKOV 3 _SmE F_I_q 3;-; 0 fZD o f N REOUIREMENTS; ROWDA BUILDING CODE SVITH EDTtION (iOZ�J) SPEED V.W.-n Usm SPEEUVi'14WAh I'ALESSURE D DIrMOMAUTY N .0.55 IWA HEIG H -.AT,GROYND 0XS PRESSURE AT HEIGHT H Qh ".'SGjbfd , Ta o Q. G CT. 50.00 WlRZ,(A5D2 GENE LNOTES ANCHOR TO PAD SCHEDULE: caurAre (2j-3,,WTI TTI & kb OR EQUIVALENT, i6me PSI 2-314'FULL EMBED, Yo CouckErE, 3. MiN, 7. EDGE DWANCI, 5* SPACING30 ANY NOTES; I. ANCSA 2: EMBM"EW AND EDGE DISTANCE EXCLUDES FLM4SS, IF A"Ll^ftEU": ` 1. ENSURE VNFWM EDGE -DISTANCE . SAS NOTED Ut A@KM9 SCHEDLU. 4. ENSURE MWMVM STACINCTO ANY ADIACENfrAhCRORS. S. FOLLOW MANUFACTURER'S INVALLATTOILUISTRUCTIONS:70 CENATIACKMENT USE, ,,VAFUES VNJH MODEL SCE GEIIERAT01l'SPECS 'SMPSCNTITF4440, IL I—— > SOIL. AS ONO is NOT CS AND PAD SIGNED i ATIONS* W'OO N ?EXPRESS Ln Ll - 0 v XION By < THIS u .ESS Ic 'L FEES sRICATION; YON&THAT Lu z �L CODES & 1E 8FlrHE FULL < L OR ALTERED. OF,