HomeMy WebLinkAboutpipingABOVEGROUtvONNDERGROUND DOMESTlC TANKS
n
0
2,000 Wig
NEW!
SHERWIN- WILLIAMS,,
POWDURAOOneCurew Super Durable Topcoat
with Zinc Rich Primer on Aboveground
I L
POWDURA® OneCureTm Two coat system properties include:
a Zinc rich epoxy primer
dome in black Plastic or white
e Super durable TGIG Polyester topcoat
galvanized steel a Superior corrosion and edge protection
6 Patent pending formulated primer and topcoat
- Dual service options for above or underground applications
. Option #1: Ready -to -bury red oxide durable Powder coating with black
* polyethylene AGUG dome*
* Option #2: Aboveground option with steel 8" AGUG dome
# All valves and float gauges are centered under dome
e Fabricated to the latest A.S.M.E. Code, Section V111, Division 1
o Registered with the National Board
* #72 liquid level outage valve orifice reduces refueling emissions
"UNITY 0 Vacuum pre -purged to save time, money and product
*Applicable federal, state, or local regulations may contain specific requirements for
protective coatings and cathodic protection. The purchaser and installer are responsible
g Our World's Energy" for compliance with all federal, state, local and NFPA industry regulations. Cathodic
protection is required and coating must be continuous and uninterrupted and must
comply with an local, state or national code.
www.TrinityContainers.com Call Toll Free: 888-558-8265
TRIN11PI
Containing Our World's Energy"
o
'
F
x
0
cU
=
U)
w
x
w
M
O
�
a
OUTSIDE
O
DIAMETER
o
a
O
O
LEG
WIDTH
General Specifications
Conforms to the latest edition of the ASME code for
Pressure Vessels, Section Vill, Division 1. Complies with
NFPA 58.
Rated at 250 psig from -200 F. to 1250 F. All tanks may be
evacuated to a full (14.7 psi) vacuum.
Vessel Finish: Coated with epoxy red powder. ( Tanks coated
with the epoxy powder must be buried). For Aboveground use,
tanks may be coated with TGIC powder.
Applicable federal, state or local regulations may contain
specific requirements for protective coatings and cathodic
protection. The purchaser and installer are responsible for
compliance with all federal, state or local regulations.
- - WITHDRAWAL
NOTICE VALVE
FLOAT .P.W�
GAUGE L.P. �"S ANODE
®11"
-CONNECTION
1 FILLER
I O O,4 VALVE
' f '
SERVICE! NAME
MULTIVALVE
___ - / - PLATE
RELIEF
VALVE
AGUG VESSEL DIMENSIO
II vessels dimensions are approximate
WATER
OUTSIDE
HEAD
OVERALL
OVERALL
CAPACITY
DIAMETER
TYPE
LENGTH
HEIGHT
120 wg.
24"
Blip
5'- 5 13/16"
3' - 0"
454.2 L
609.6.mm
1671.3mm
911.4 mm
250 wg.
31.5"
Hem!
7' - 2 112"
3' - 7 1/2"
946.3 L
800.1 mm
2197.1 mm
1104.9 mm
320 wg.
31.5"
Hemi
8' -11 3/4"
3' - 7 1/2"
1211.2 L
800.1 mm
2736.9 mm
1104.9 mm
500 wg.
37.42"
Hemi
9' - 10"
4' - 1 7/16"
1892.5 L
950.5 mm
2997.2 mm
1255.7 mm
1000 wg.
40.96"
He m!
15' -10 13/16"
4' - 4 5/16"
j 3785.0 L
1040.4 mm
4846.6 mm
1344.6 mm
FITTINGS LAYOUT UNDER DOME
NAL INFPRMATION
LEG
LEG
WEIGHT
QUANTITY
WIDTH
SPACING
FULL PER
LOAD STACK
10 1/8"
3' - 0"
245 lbs.
96
12
257.2 mm
914.4 mm
111.1 kg.
12 3/4"
3' - 6"
472 lbs.
63
9
323.9 mm
1066.8 mm
214.1 kg.
12 3/4"
4' - 0 1/4"
588 Ibs.
45
9
323.9 mm
1225.6 mm
g.
15"
5' - 0"
s.
t395.1
30
6
381.0 mm
1524.0 mmg
16 1/4"
9' -0"
1729 Ibs.
15
5
412.8 mm
2743.2 mm 1
784.3 kg
Rev: Jan. 27, 2016