Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
scheme
0 BOARD OF COUNTY OMMISSIONERS [A2] TANK SIZE 1] PLANNING & DEVELOPMENT SERVICES DEPARTMENT Building and Code Regulation Division GAS PIPING SCHEMATIC 1.61 L [A4] [A6] [L12] [A1] . [A3] [AS] TANK SIZE: `7 7 GALS. APPLICANCE — TYPE/SIZE Al i A2 A3 A4 A5 A6 PIPING LENGTH & SIZE H L1 l 0 FT. Ya INCH DIA. L2 FT. INCH DIA. L3 FT. INCH DIA. L4 FT. INCH DIA. L5 FT. INCH DIA. L6 FT. INCH DIA. L7 FT. INCH DIA. L8 FT. INCH�DIA. L9 FT. INCH DIA. L10 FT. INCH DIA. L11 FT. INCH DIA. L12 FT. INCH DIA. Revised 7/22/14 BTU BTU BTU BTU BTU BTU (PIPE SIZE WAS TAKEN FROM THE 2014 FBC FUEL GAS CODE - TABLE 402 (J) Website: www.stiucieco.gov 2300 Virginia Avenue - Fort Pierce, FL. 34982-5652 Phone (772) 462-1553 FAX (772) 462-1578 i Copyright 2013 National Fire Protection Association (NFPA). Licensed, by agreement, for individual use and single download on A ril 10, 2013 to AMERIGAS for designated user BRIAN PEARL. No other reproduction or transmission in an permitted without written permission of NFPA. For inquires or to unauthorized use, contact licensing@nfpa.org. 54-50 NATIONAL FUEL GAS CODE ANSI Z223.1-50 Table 6.3 (d) Schedule 40 Metallic Pipe Gas: Undiluted Propane Inlet Pressure: llll`,tnciv`ie. Pressure Drop: 0.5 in. W.C. Specific Gravity: 1.50 a �� - N - t, iNTl NDEL7517 Prpe�rzmg )3eeen $mg�l or 5WvpecodStaB$ {LoxxPrFssuceIieptrlatarand A .- Pipe Size (in.) Nominal Inside: is 31 1 1% li/t 2 3 4 Actual: 0.622 0.8.24 1.049 1.380 1.610 2.067 2.469 i 3.068 CO26 Length (ft) Capaci4rin Thousands of Stu per Hour U. 29-11 608 1.150 2,350 3,520 6,790 10,300 19,100 39,000 20 200 418 787 1,620 2,420 4,660 7,430 13.100 26.800 30 160 336 632 1,300 1,940 3,750 5,970 10,600 21,500 40 .137 287 541 1,110 1,660 3,210 5,110 9,030 18,400 50 122 255 480 985 1,480 2,840 4,530 8.000 16,300 60 110 231 434 892 1,340 2,570 4,100 7,250 14,800 80 101 212 400 821 1,230 2,370 3,770 6,670 13,600 100 94 .197 372 763 1,140 2,200 3,510 6,210 12,700 125 89 185 349 716 1,070 2,070 3,290 5,820 11,900 150 84 175 330 677 1,010 1,950 3,110 5,500 11.200 175 I 74 155 292 600 899 1,730 2,760 4,980 9,950 201 67 140 265 543 814 1,570 2,500 4,420 9,010 250 62 129 243 500 749 1,440 2,300 4,060 8,290 300 58 120 227 465 697 1,340 2,140 3,780 7,710 350 51 107 201 412 618 1,190 1,900 3,350 6,840 400 46 97 182 373 560 1,080 1,720 3,040 6,190 450 42 89 167 344 515 991 1.580 2,790 5,700 500 40 83 156 320 419 922 1,470 2,600 5,300 550 37 78 146 300 449 365 1,380 i 2,440 4A70 600 35 73 138 283 424 817 1.300 2,300 4,700 650 33 70 131 269 403 776 1,240 2,190 4,460 700 32 66 125 257 385 741 1,180 2.090 4.260 750 30 64 120 246 368 709 1,130 2,000 4,080 800 29 61 115 236 354 681 1,090 1,920 3,920 850 28 59 111 227 341 656 1,050 1,850 3,770 900 27 57 107 220 329 634 1,010 1,790 3,640 950 26 55 104 213 319 613 978 1,730 3,530 1,000 25 53 100 206 309 595 948 1,680 3,420 1,100 25 52 97 200 300 578 921 1,630 3,320 1,200 24 50 95 195 292 562 895 ' 1,580 3,230 1,300 23 48 90 185 277 534 850 1,500 3,070 1.400 22 46 86 176 264 509 811 1,430 2,930 1,500 21 44 82 169 253 487 777 1,370 2,800 1,600 20 42 79 162 243 468 746 1,320 2,690 1,700 19 40 76 156 234 451 719 1,270 2,590 1,300 19 39 74 151 226 436 694 1.230 2,500 1,900 18 38 71 146 219 422 672 1,190 2,420 2.000 18 31 69 142 212 409 652 1,1.50 2,350 Note: All table entries are rounded to 3 significant digits. n2012 Edition 1/8"COATED CABLE W/ (2 CLAMPS TO ANI (PULLED T GENERAL NOTES: 1. ffiT( 4ANUTYPE2. � TANK AS SHOWN H :NT. LOAT DESIGN CRIT (STATE WWI, !-Ott l.fl A- ti 6XY DOCK ANCHOR HAVE AN ALLOWABLE PULL-OUT CAPACITY OF 400#. ANCHORS SHALL BE INSTALLED. PER ANCHOR JEO LOAD CAPACITY. CAPACITY VARIES WITH SOIL TYPE. VERIFY ANCHOR CAPACITY WITH SOIL j �WIIJTIES PRIOR T0. ANCHOR INSTALLATION DESO ADJACENT. STRUCTURES AND FEATURES IS DEPENDENT UPON LOCAL CODES AND IS THE i ,*Eta! DESIGNED TO PREVENT FLOTATION, COLLAPSE, OR LATERAL MOVEMENT. DURING THE BASE w ft Iso G C= GCpi N/A; C# = 0.6 FE: I AMERIGAS 20-2017 0 COPYRIGHT 2017 — .FARLEY ENGINEERING, LLC Corisulting Engineer #40111 — CA26108 8800 N. U.S. #1; Suite #2 , Sebastian, Florido 32959 (772) 589.2296 fox CALCULATION WORKSHEET: i 'Step 1 !Calculate the room volume li Step 2 Calculate the total input of appliances in the room. Enter the input rating of all appliances in table 1. Total the column. Divide the total by 1000 (of Btu/hr). Step 3 Calculate the required volume: Divide room volume (Step1) by total/1000 (Step2) If less than 50, additional air is needed. If greater than or equal to 50, no additional air is needed. AmeriGas 3301 Oleander Ave Fort Pierce, FL Bruce Coberly Operations Coordinator COMBUSTION AIR, • Room volume: Room length Room width Room height Room volume = Length X width X height 16330 Sqft Table 1 Aooliances Table STANDARD METHOD 23 71 10 Appliance Input rating (Btu/hr) Pizza oven Water Heater Stove 110,000 Dryer Logs Total Total/1000 110 Required volume: 16330 Sqft 110 148.454545 Additional air needed? (Check one), Yes No x Customers Name Gerald and Susan Smith 7671 Charleston Way Port St lucie FI 34986 NFPA 54 FUEL GAS CODE