HomeMy WebLinkAboutproduc appF(A Manu(ac!ufed l3wit ing Program
1940 North Morirae SlrM
Uu"sines ,(,,,I SuOe90A
Professional TaQahassee, Florida32399-OT72
Phone- M4871824• Fax: 85041484M
Ken Lawson, Secretary
August 22, 2016
Robert Moore
Lark Builders, Inc.
P,O,Drawer 629
Vidalia, GA 30475
RE: Manufacturer Certification, ID MFT-114; Expiration Date: August 22, 2019
Dear Robert Moore
It is my pleasure to inform you that Lark Builders, Inc., located at 409 DIXON STREET, P 0
DRAWER 629, VIDALIA, GA 30475, has been approved under the Manufactured Buildings
Program, as provided for under Chapter 5�3, Part I, Florida Statutes, to manufacture Factory
Built Schools, Storage Sheds, Manufactured Buildings for installation In Florida.
Construction or modification on a manufactured building* cannot begin until the Third Party
Agency has approved the plans In accordance with the current Florida Building Code. Your Third
Party Agency is a contractor for the Department and has statutory authority and responsibilities
that must be met to maintain approved status. You may expect and demand quality plans
review and inspections,
Each Code change will make your plans obsolete until they have been reviewed, approved and
indicated [on the cover page of the plans] for compliance with the Code by your Third Party
Agency for plans review. Please ensure that your plans are In compliance and are properly
posted on our website. All site -related Installation Issues are subject to the local authority
having jurisdiction.
The Department's contractor will make unannounced monitoring visits at least once each year..
You must grant complete access to your manufacturing facility and records to remain in
compliance with the rules and regulations of this program,
Your certification is approved for three years from this date. You will receive a renewal notice by
Email generated by the BCIS (wwev.floridabuililing:org) for online renewal. If you have questions
you may contact Robert Lorenzo at 850-717-1835 or our FAX at,850-414-8436.
Please visit our website at www.floridabuildina ora to see valuable information on the Florida
Manufactured Buildings Program. A copy of this letter must accompany applications for local
building permits.
Sincerely,
Robert Lorenzo
Manufactured Buildings Program
cc: Professional Service Industries
Rick Scott, Govemor
FILE 10PY
E
r"
w
C
April 3, 2019
E ENGINEERING, LLC
STRUCTURAL ENGINEERS
Mr. Thomas Campbell
Florida Department of Business and Professional Regulation
2601 Blair Stone Road
Building C
Tallahassee, Florida 32399-6563
RE: Plan Approval
Lark Builders, Inc.
Plan # 43450.
Dear Mr. Campbell,
Per the requirements of the Florida Department of Business and Professional
Regulations, the above referenced plans have been reviewed for compliance with:
2017 Florida Building Code, 6th Edition
2014 National Electrical Code (NFPA-70)
These plans comply with Florida Product Approval Rule 61 G20-3.006 (FAC)
A signed and sealed set of plans are maintained on file with Topline Engineering,
LLC.
All mandatory comments have been satisfied and plans are approved for
construction by a currently approved modular building manufacturer.
If you have any questions or require my assistance in any way, please do not
hesitate to contact me.
Thank you.
Res ectfull ,
William E. Neary,r1l
Business Partner
Topline Engineering, LLC
BILL.TLE@yahoo.com
10649 Cakview Pointe Terrace • Gotha • FL 34734 • Phone (407) 421-4037 • Projects. o.
FL Certificate of Authorization 31785
t
0
C)
Lo
N
Q
v pm
—AbL TOP LINE ENGINEERING. LLC
6W, CfUML ENGINEERS
Z Z
William E. Neary, III
o 0
LL
SMP-51, SMI-79, ICC 5185040
J 0
ROOF SHEATHING OPTIONS:
10649 Oakview Pointe Terrace
Gotha, Florida 34734
®
— BOX RIB ALUMINUM
DESIGN PRESSURES
W
— 29 GAUGE STEEL AG PANEL
— STANDING SEAM STEEL
ROOF+41.7/-141.
W
®
— ASPHALT SHIGLES
WALLS/DOORS/WINDOWS+
48.8/-43.9
0
4�1i♦
50'-0" MAXIMUM BUILDING LENGTH — 30'-0" MAX FOR VAULTED ROOF
H U U� FRAMING PLAN FOR CONTINUOUS LOAD TRANSFER PATH
co vcaaox
,M1AFA:lUREN
We
10/15/17
N/A
LB-S-LEE-200D
Ln
w
w
T
_W4_***N~F-ar
; STATE I.,
���0 .•. FOR ��
D
O
IDP sc�OF
.......
0 i i i
uellee. T. B.Id.. P.E.
O
nordo UOM5 o 646D8
�
sh— FBPR-1OF 7
3.5"-20GA METAL COLLAR TIE, 4'-0-
LONG ATTACHED WITH (2) #10 SELF
DRILLING GRABBER SCREWS EACH SIDE
a
3
SEE ROOF FRAMING
SCHEDULE FOR RAFTER AND
BRACING SPACING
ION —VARIES. 6'-0" TO
FRAME SECTION
THIS: BUILDING IS NOT APPROVED FOR HVHZ
ATTACH ROOF FRAMING TO
TOP PLATE OF WALL FRAMING
WITH BUILDEX 10-16X1 TEKS
Q
1s3'J
PANHEAD SCREWS WITH #3 DRILL
POINT AT 6" O.C.
CODE I
CCOL KPSCN
TIO"N •w • m. J• a
2.5"x.5" CORRUGATED ROOF PANELS
FASTENED WITH .25"-14a.75" HWH SEE ROOF FRAMING
TRAXX/1 AT 6" O.C. SCHEDULE FOR RAFTER AND
BRACING SPACING
3.5-20GA METAL STUDS
SPACED AT 16" O.0 MAX.
OVERHANG OPTION DETAIL
3.5"-20GA METAL STUDS,
SPACED AT 24" O.0 MAX.
3.5" BRACE AT 3'-0-
ABOVE FINISHED FLOOR,
ATTACH TO EACH STUD W/(2) #10
SELF DRILLING GRABBER SCREWS.
(1) INTO EACH FLANGE
_ SHEATHING FASTENED W/
#80.5" GRABBER SCREW (OR
EQUAL) AT 6" O.C. _
SEE ROOF FRAMING N
SCHEDULE FOR RAFTER AND —
BRACING SPACING
�y TOP LINE ENGINEERING LLC
�I_�Y, STRUCTURAL ENGINEERS
William E. Near Y ,III
3.5-20GA METAL STUDS
SPACED AT 16" O.0 MAX.
SMP-51, SMI-79, ICC 5185040
10649 Oakview Pointe Terrace
Gotha, Florida 34734
MTB
10/15/17
N/A
LB—S—LBE-200D
ATTACH ROOF FRAMING TO
W
TOP PLATE OF WALL FRAMING
a
WITH BUILDEX 10-16X1 TEKS
LlU
PANHEAD SCREWS WITH #3 DRILL
X
POINT AT 6" O.C.
0
CO
.:o.mm Bone
W
Lu
��I�T
�•
•W
........
t
�'•:��o'��
V%CENSC
N=
�: N
i T :4
STATE ry
i p•.
_J
i„�••,. FLORIDP
LLJ
1'/0 11111%%
OVERHANG OPTION DETAIL L, NeII T. Beldein P.E.
O Florida license #64608
PROVAL PLAN #43450. B^reI FBPR-2 OF 7
3.5• BMCE AT 3'-D•
ABOVE —ED FLOOR.
M. STIR) w/(2) F10
.LNG GRABBER ( UL
(1) INTO FACN FLANGE
END WALL FRAMING OPTION
END WALL FRAMING OPTION
TOP LINE ENGINEERING, LLC
STRUCTURAL ENGINEE0.5
William E. Neary, III
SMP-51, SMI-79, ICC 5185040
10649 Oakview Pointe Terrace
Gotha, Florida 34734
-CODA METAL BMCWD. 3.5' BRACE AT Y-O'
MR GCN END TO STUDS w/ (2) ABOVE FW%IED FLOOR.
I XRCWS. (1) INTO EA RANGE A1r.. TO W. $ w/p) #I.
XIr DRILLWG GMEBER XRERS,
TMK RRAFWD K RF fn pN SNF (1) INTO W. FLANGE
�S rROTN em RNERt
F.r.E.• •NEGLEOTING U. R BLOCAWG
(Mr,M BE REOWRED)
FnR E
sNowN N
3.S•-20GA METAL BRACING. 3.5• BMCE AT S-0'
AlE.N DCN END TO STUDS ABOVE FWKNED FLOOR.
/To ..M (1) 1-0 E—I FLANGE ATFALn TO FACN BTUD w/t]) IT .
SCLF DRw G GRABBCR REwS.
xOTE TMK nR• Iure BE En DNS (1) INTO DIIEN rvwA
__ tBOTN smfR pE r+�R rpaxERT
12S F.F.E.•
ROOF RANFis FASTENED
as• Nw
• o.D. N
3.5'-20G METAL BMCWG.
ATIACR UCH END TO STUDS w/ (2)
r10 —EN% (I) INTO Gbl FLANGE
tATF• TNK RFOIiIRFn ON w < (BOM F Of u•x FORxER)
END WALL FRAMING OPTION
ROOF PANRS FASTENED
NAN
C
END WALL FRAMING OPTION
ti_
-LLU
CODE INFORMATION
CODE vERsax 1-Mu"AMAZ
WTB
To/*/n
N/A
LB-S-LBE-200D
a
mRFWnMOwsF,.`D�aR
er
IF��
'-20G
Q
METAL BRACWG.
— EACN END TO STUDS N/ (2)
XRCVS. (1) INTO F NNGE
.eNrso Tre
T TNK BR D IR n SIDE
<
xss�
weq
\\��...........T.
•\,(CENSf•
F.F.E.•
I
�. N
~
�
i c4�
STATE
/i/ (S'•...............• G� \\\
10
MOtlhew T. BDldwin P.E.
Florida License #64608
sheet. FBPR-4 OF 7
w
SKID RUNNER SPACING*
UNDER 30' LENGTH
SHED WIDTH
A
B
6'-0"
15"
42"
8'-0"
18"
60"
1O'-0"
18"
84"
11'—O"
24"
84"
11'-8"
28"
84"
13'-0"
36"
84"
13'-8"
40"
84"
'VALUES ARE FROM END OF JOIST
TO CENTERS OF SKIDS ONLY.
WIDTH
J0IST SIZE-
6,_0_
2"x4"
6'-1" TO 11'-8"
1 2"x6"
> 11'-8"
1 2"xB"
-NOTE: JOISTS CAN BE EITHER #2 S.Y.P. OR 18 GAGE
STEEL CHANNELS. THE STEEL CHANNEL ACTUAL
DIMENSIONS MATCH THE WOOD ACTUAL DIMENSIONS AND
ARE INTERCHANGEABLE.
o� TOP LINE ENGINEERING. LLC
ST0.Q URAL ENGINE
William E. Neary, III
SMP-51, SMI-79, ICC 5185040
10649 Oakview Pointe Terrace
Gotha, Florida 34734
-FLOOR SHEATHING SECURED WITH
4'XO.113' NAIL (OR EQUAL) ® 6"O.C. MAX
MTB
10/15/17
I-- LB-S-USE-2000 I
W
wnruwnw
Wffwmuma..areeronr3av�er..
X
O
M
Lj
g
E N... T :
�
''•. O�yi
W
•'• oCENS4.
W
~
`��`ti
R i '
N 8
S STATE
Mullre« T. Bold.;n P.E.
0
Florida Lken a fG4608
O
Shrel: FBPR-5 OF 7
SKID RUNNER SPACING*
UNDER 30' LENGTH
SHED WIDTH
A
B
6•-0"
15'
42"
8'-0"
18"
60"
10'- 0"
16"
84"
24"
84"
28"
84"
13'-0"
36"
84"
13'-B"
40"
84"
'VALUES ARE FROM END OF JOIST
TO CENTERS OF SKIDS ONLY.
SCHEDULE FOR SIZES
THISBUILDING IS.NOTAPPROVEDfORHVHZ
2"x4"
6'-1" TO 11'-8"
2"x6"
> 11'-8"
2"x8"
-NOTE: JOISTS CAN BE EITHER #2 S.Y.P. OR 18 GAGE
STEEL CHANNELS. THE STEEL CHANNEL ACTUAL
DIMENSIONS MATCH THE WOOD ACTUAL DIMENSIONS AND
ARE INTERCHANGEABLE.
*FLOOR SHEATHING SECURED WITH
2J'XO.113" NAIL (OR EQUAL) 0 6"O.C. MAX
SKID RUNNER . SPACING*
30' LENGTH AND GREATER
SHED WIDTH
A
B
6'-0"
12"
24"
8'-D"
16"
32"
10'-0"
20"
40"
11,-0"
22"
44"
11'-8"
24"
46"
13'-0"
26
52"
13'-8"
28"
56"
'VALUES
ARE FROM END OF JOIST
TO CENTERS OF SKIDS ONLY.
SKID FLOOR FRAMING PLAN
UF'IIUNAL HUINCH
All
William E. Neaq, III
SMP-51, SM1.79, ICC S185040 (�
1O 9 OaW.. Pointe T¢rra<e
Gorha. Florida 3a734
REVISIONS
MTB
10/15/17
N/A
LB—S—LBE-200D
W
Q
W
X
O
M
Of
LIJ
0
N
Q
��Ilu Tmllll"�i
WIN
co
�1:, STATE
Q
F—
0'• F0L0 RIDP
�ii FS'••'•• •'
...• G1
';�/S/ONALE \��
"11111 I111o�
Mntth— T. Bnldwin P.E.
O
Florid, License ii
0
t -J
SNttt FBPR-6 OF 7
.C�
4v
U
El ECTRICALNOTES,
1. ALL WIRE TO BE #12 THHN SOLID COPPER WITH GROUND. WIRING PROTECTED BY NEC 2014 EDITION.
2. FIXTURE LOCATION AND TYPE MAY VARY
3. PLASTIC OR METAL "NEW WORK" OUTLET BOXES
4.20A GFCI OUTLETS
5. ALL RECEPTACLES TO BE AT 12"-16" A.F.G.; MAXIMUM 8 RECEPTACLES.
6. ALL SWITCHES TO BE AT 48"-52" A.F.G.
7. FLUORESCENT & LED LIGHTS MAY SUBSTITUTE FOR INCANDESCENT LIGHTING
8. ALL OUTLETS TO BE GFCI
9. THE MAIN ELECTRICAL PANEL. FEEDERS, POWER HOOKUP TO UNIT (INCLUDING ALL DISCONNECTS, OVER CURRENT
DEVICES, PANELS, GROUNDING, ETC.) IS DESIGNED BY OTHERS, SITE INSTALLED, AND SUBJECT TO LOCAL APPROVAL.
LECTRICAL
SYMBOL KEY
QRECEPTACLE
240V
240
RECEPTACLE
SINGLE POLE
SWITCH
THREE WAY
R
SWITCH
CEILING MOUNT
LIGHT FIXTURE
WALL MOUNT
LIGHT FIXTURE
O
FLUORESCENT
LIGHT FIXTURE
JUNCTION BOX
P LINE ENGINEERING LLC
ST0.UCrURAL ENGINEERS
William E. Neary, III
SMP-51, SMI-79, [CC 5185040
10649 Oakview Pointe Terrace
Gotha, Florida 34734
WINDOW HEIGHT, LOCATION
AND QUANTITY MAY VARY
AND ARE OPTIONAL
II \
SEE VARIOUS END WALL \
FRAMING SECTIONS FOR
WALL AND DOOR FRAMING
w
\ I z
OPTIONAL ELECTRIC TO EACH UNIT
WILL BE FIELD CONNECTED FROM
EXISTING POWER SOURCE
3.5" METAL STUDS
SPACED AT 24"
O.C. MAX
SEE VARIOUS END WALL
FRAMING SECTIONS FOR
WALL AND DOOR FRAMING
50'-0" MAXIMUM BUILDING LENGTH
NOTE: ALL ELECTRICAL EQUIPMENT SHOWN IS OPTIONAL AND LOCATIONS MAY VARY
MRB
to/t s/n
N/A
LJ
LB—S—LBE-2001)
X
m
o-
LLJ
0
J
,
W
%%u fill
Lu
WG NS Bq
Lo
N 8Lu
FQ-
_
i :•
0
OOFATE
��0'••y F L O R I D N: •`�?�`�
I-
O
H
U
Ltattne,. T. Bom.ln P.E.
Florida Lkense #64608
LJ