GENERATOR
ID
1
PAD
THICKNESS
ISOMETRIC VIEW
PAD DIMENSIONS:
CONCRETE PAD
GENERATOR
CONCRETE
ROAD MESH-
IASTERFIBER.
MAC100
GENERATOR UNIT BY
SEPARATE SUBMITTAL
(SEE SCHEDULE FOR
MINIMUM WEIGHT
REQUIRED)
54" LENGTH
PLAN VIEW
3" MIN r 4" MIN
AMERICAST GENERATOR CONCRETE PAD
GENERATOR TABLE:
(ON -GRADE APPLICATIONS ONLY)
in
AMERICAST
•MADID M 1,IMIERliJAI'
FIm TA%£3Ri]S2163 LID6NSEY599306{019
5103 PYAtiw Avu Wn Nutt V1949t2
nl. 'rTI-P7iaPSsra: fT.1JNO5RP
Fsull: ylellrmdtu.MarmmeN•.IMeGMIRwM„epu
HVHZ OR NON-HVHZ
RISK
EXPOSURE [EXP)
I RISK
I EXPOSURE(EXP)
I RISK
I EXPOSURE(EXP)
COUNTY
I
C
D
II
C
D
III, IV
C
D
P. BEACH
150 MPH
30.44 Psf
36.94 Psf
170 MPH
39.09 Psf
47.44 Psf
180 MPH
43.83 Psf
53.19 Psf
BROWARD
156 MPH
32.92 Psf
39.95 Psf
170 MPH
39.09 Psf
47.44 Psf
180 MPH
43.83 Psf
53.19 Psf
MIAMI-DADE
165 MPH
36.83 Psf
44.69 Psf
175 MPH
41.43 Psf
50.28 Psf
186 MPH
146.80 Psf
156.80 Psf
BRAND&MODEL
CAPACITY
WIDTH
LENGTH
HEIGHT
WEIGHT
ALLOWABLE
PRESSURE
COMMENTS
Generac 005871 & 005883
10 KW
25.00"
48.00"
29.00"
387Its
41.43 Psf
EXPC 175 MPH &D 156 MPH
Generac 005972 & 005884
14 KW
25.00"
48.00"
29.00"
439lbs
47.44 Psf
EXP C 186 MPH &D156 MPH
Generac 6459, 6461, 6462
16 KW
25.00"
48.00"
29.00"
513 lbs
47.44 Psf
Generac 006721
16 KW
25.00"
48.00"
29.00"
4481bs
47.44 Psf
Generac 005873 & 005895
17 KW
25.00"
48.00"
29.00"
455 lbs
47.44 Psf
Generac 005874 & 005886
17 KW
25.00"
48.00"
29.00"
4211bs
47.44 PIE
Generac 005875 & 005887
20 KW
25.00"
48.00"
29.00"
451 lbs
47.44 Psf
Generac 006729 & 006730
20 KW
25.00"
48.00"
29.00"
516 lbs
47.44 Psf
Generac 006551 & 006552
22 KW
25.00"
1 48.00"
29.00"
526lbs
47.44 Psf
Kohler 14RES&20RES
14-20 KW
26.00"
48.00"
29.00"
500lbs
47.44 Psf
GE 40323GE & 40324GE
13 KW
35.00"
39.40"
39.00"
540lbs
39.09 Psf
EXP C 170 MPH &D 156 MPH
GE 040382 ISKW
15 KW
33.00"
48.00"
30.50"
484lbs
43.83 Psf
EXP C 180 MPH &D156 MPH
GE 04037817KW
17 KW
33.00"
48.00"
30.50"
484lbs
43.83 Psf
GE 403306E&40331GE
20 KW
33.00"
48.00"
30.50"
600lbs
43.83 Psf
Briggs& Stratton 040243-0
SO KW
31.00"
32.00"
34.00"
430 lbs
43.83 Psf
Briggs & Stratton 040302-2
12 KW
33.75 "
50.00 "
31.60 "
507 lbs
41.43 Psf
EXP C 175 MPH & D 156 MPH
Briggs & Stratton 040303-1
15 KW
33.75"
49.00"
31.60"
562 lbs
43.83 Psf
EXP C 180 MPH & D 156 MPH
Briggs & Stratton 040304-1
18 KW
33.75"
49.00"
31.60"
568 lbs
44.00 Psf
Briggs & Stratton 040305-1
20 KW
33.75 "
49.00"
31.60"
570 Ibis
44.00 Psf
Generac 7035, 7036, 7037
16 KW
25.00"
48.00"
29.00"
406 lbs
47.44 Psf
EXP C 186 MPH & D 156 MPH
Generac 007038 & 007039
20 KW
25.00"
48.00"
29.00"
448 lbs
47.44 Psf
Generac 007042&7043
22 KW
25.00"
48.00"
29.00"
466lbs
47.44 Psf
GENERATOR MOUNTING CONFIGURATION:
GENERATOR ATTACHMENT BASE
OR SIMPSON A24 ANGLE BRACE
W/ (4) #10 SS 316 SELF -DRILLING
SCREWS
OO TO GENERATOR
(SEE GENERATOR SPECS)
GENERATOR
(SEE CONCRETE PAD
SCHEDULE FOR
2 = DIMENSIONS WEIGHT
REQUI4'
+-32" WIDTH 'I54" LENGTH
SIDE VIEW
FRONT VIEW
GENERATOR
FILE
ST.LUCIECOUNTY RCI.CiVBU
PLAN REVIEW
® JUN 2 6 2019
BLDG:
DATE:. ST. Lucie County, permlttmg
ELE
,
DATE:
PLUMB:
WIND DESIGN REQUIREMENTS
DATE.
(BASED ON ASCE 7-10 & FLORIDA BUILDING CODE SIXTH EDITION
(2017))
MECH;
AT -GRADE SIGN METHOD
ULTIMATE DESIGN WIND SPEED Vult = 186 mph
DATE:
NOMINAL DESIGN WIND SPEED Vasd = 144 mph
RISK CATEGORY = III INTERNAL PRESSURE COEF = N/A
EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd=
0.85
ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND
GUST EFFECT FACTOR = 0.85 PRESSURE AT HEIGHT H qh = 77.56
Ib/ft2
FORCE COEFFICIENT Cf = 1.44
ANCHOR TO PAD SCHEDULE: WIND PRESSURE
P = qh G Cf = 56.80 Ib/R2 (ASD)
SUBSTRATE
DESCRIPTION
CONCRETE:
(2)-3/8"0 TITEN HD
(6000 PSI
OR EQUIVALENT,
MIN.)
2-3/4" FULL EMBED
0 CONCRETE, 3" MIN.
EDGE DISTANCE, 6"
MIN. SPACING TO ANY
ADJACENT ANCHOR.
NOTES:
1. ANCHOR QUANTITY PER LONG SIDE
2. EMBEDMENT AND EDGE DISTANCE
EXCLUDES FINISHES, IF
APPLICABLE.
3. ENSURE MINIMUM EDGE DISTANCE
AS NOTED IN ANCHOR SCHEDULE.
4. ENSURE MINIMUM SPACING TO
ANY ADJACENT ANCHORS.
5. FOLLOW MANUFACTURER'S
INSTALLATION INSTRUCTIONS TO
INSTALL ANCHORS.
GENERATOR
ATTACHMENT BASE,
VARIES WITH MODEL
SEE GENERATOR SPECS
%- SIMPSON TITEN HD, -
SEE ANCHOR SCHEDULE
2"x3"x3/e" GALV. STEEL �
WASHER
RUBBER VIBRATION PAD
THICK GALVANIZ ED \
WASHER& RUBBER
VIBRATION PAD
e
CONCRETE PAD
m
6WEI PSI
CONCRETE PAD X
6,000 PSI
LIGHTWEIGHT
CONCRETE MIX
LIGHTWEIGHT MASTERFIBER
MAC 100
CONCRETE MIX
& ROAD MESH
2
NOTES:
FOAM CORE
1. Y DISTANCE DEPEND ON GENERATOR BASE LENGTH, NO LESS THAN 2".
2. X DISTANCE 3" FROM UNIT EDGE TO CLIP.
3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS THAN
ANCHOR REQUIREMENTS
GENERAL NOTES
1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN
ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE
SIXTH EDITION(2017).
2. REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH
THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON I
JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE,
SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINED IN ACCORDANCE WRY
THE APPLICABLE BUILDING CODE SHALL BE LESS THAN OR EQUAL TO THE
DESIGN PRESSURE "ASD" CAPACITY VALUES LISTED HEREIN FOR ANY
ASSEMBLY AS SHOWN.
3. DIMENSIONS AND WEIGHT OF UNITS SHALL CONFORM TO SPECIFICATIONS
STATED HEREIN.
4. UNITS MUST BE CENTERED ON PAD WITH OPPOSITE SIDES HAVING EQUAL
CLEARANCE. A MINIMUM DISTANCE FROM UNIT TO PAD EDGE IS SPECIFIED.
5. CALCULATIONS MADE USING LIGHTWEIGHT CONCRETE 125 PCP
6. THE AREA UNDER CONCERETE SLAB ON GROUND SHALL HAVE ALL
VEGETATION, STUMPS, ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR
TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY OTHERS.
7. RESISTANCE TO SLIDING OF THE PAD ON THE GROUND IS NOT PART OF THIS
DOCUMENT AS SOIL CHARACTERISTICS AND PAD PLACEMENT VARIES,
S. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY
OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.)
SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE
EXPRESS RESPONSIBILITY OF THE CONTRACTOR.
9. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS
SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, at. al.
INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGE!
INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL
FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT
WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM
DEVIATIONS OF THIS PLAN.
10. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL
RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL
ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS
RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE
PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY
WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS
WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILIFY OF THE INSTALLING
CONTRACTOR.
11. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY
ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE
ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE
INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL
BE COORDINATED BY THE PERMITTIN
G CONTRACTOR.
12. THISDOCUMENTSITEN IS GENERICINFORMATION
ANDDOES AINED HE PERTAINIS TO BASE ON
PROJECT SITE. INFORMATION CONTAINED HEREIN IS BASED ON
CONTRACTOR -SUPPLIED DATA AND MEAS
UREMENTS. ENGINEERING EXPRESS
SHALL NOT A HELD RESPONSIBLE LIABLE INANY WAY FOR ERRONEOUS
OR INACCURATE OR MEASUREMENTS. DIMENSIONS ARE SHOWN TO
ILLUSTRATE DESIGNGN F FORCES AND OTHER DESIGN CRITERIA. THEY VARY
SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN.
WORK SHALL BE FIELD VERIFIED BY OTHERS PRIORGIVE CONSTRUCTION.
ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO
REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE
INFORMATION PRIOR TO MODIFICATION OF E)CSTINGMATERIALS.
FIELD ALTERATIONS
R
AND FABRICATION AND INSTALLATION OF MATERIALS. AND
INVALIDATE
OR
ADDITIONS O THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR
CERTIFICATION.
13. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS
OR AFFIRMATIONS ARE INTENDED.
L.
P.E.
NOT CONSIDERED SIGNET
SEALED. IF THERE IS NO
EAL SIGNATURE ON SHEET 1
HIS SHEET DOES NOT
-AIN AN ENGINEER'S
INAL SIGNATURE & SEAL,
ID N
O It
It o
EDMpu2
�F In Li
U� l�a�rn
uN ^ww
Oj= O�`zar
FUi U" Ewa
Q LU a ° O
M '�
co T ti Z
,. . 09
of NC ZED
0 . J ^ w U
U W NO,
LEI
W
0, w
l0 Q
rl
e 00 0 0
a
HM
K¢ S EL E.-wo
� �' wo LL SCEs
W t o a
NPYWGHT ENGINFEW NG EXPRESS®
17-3961.1
I