HomeMy WebLinkAboutepl card2017 EPL DISPLAY CARD 17642WOOC3
DECEIVED
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDE =106UG 0 2 ?019
The lower the Energy Performance Index, the more effic d'rii thtelabmey, Permitting
1. New home or, addition 1. Existing (Projected) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
c) AHU location Mech
3. No. of units (if multiple -family)
3.
1
4. Number.of bedrooms
4.
6
13. Cooling system: Capacity
33.0
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1214
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.700
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.550
14. Heating system: Capacity
8.0
c) Area
7c.
163.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c:,
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
5.0
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
Yes
a) Under attic
11 a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
`Label required by Section R303.1.3 of the Florida
Building Code,
Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be comp 001edoryW ompliant features.
CODE COMPLIANCE ' 4
Builder Signature: Dat
Address of New Home: 2805 Bra City/FL Zip: Fort Pierce, FL
9 2:13:24 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Baptiste
Builder Name:
Street: 2805 Brantley Road
Permit Office:
City, State, Zip: Fort Pierce, FL ,
Permit Number:
Owner: Merizer & Carole Baptiste
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
I
1. New construction or existing Existing (Projecte
9. Wall Types (1176.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
b. N/A
R=5.0 1176.00 ftz
R= ft
3. Number of units, if multiple family 1
c. N/A
R= ffz
4. Number of Bedrooms 6
d. N/A
R= ftz
5. Is this No
10. Ceiling Types (1213.0 sqft.)
Insulation Area
a worst case?
a. Under Attic (Vented)
R=30.0 1213.00 ft2
6., Conditioned floor area above grade (ftz) 1214
b. N/A
R= ftz
Conditioned floor area below grade (ftz) 0
11 Ducts
_ z
R R ftz
7. Windows(163.0 sqft.) Description Area
a. Sup: Attic, Ret: Kitchen, AH: Mech
6 213
al. U-Factor: Sgl, U=0.70 163.05 ftz
SHGC: SHGC=0.55
b. U-Factor: N/A ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
33.0 SEER:15.00
c. U-Factor: N/A ftz
SHGC:
13. Heating systems
kBtu/hr Efficiency
U-Factor: N/A ftz
a. Electric Strip Heat
8.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.561 ft.
Area Weighted Average SHGC: 0.550
14. Hot water systems
Cap: 40
a. Electric
gallons
8. Floor Types (1212.6 sgft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1212.60 ftz
b. Conservation features
li. N/A R= ftz
None
. N/A R= ftz
15. Credits
CF, Pstat
Glass/Floor
Total Proposed Modified Loads: 53.48
Area: 0.134
PASS
Total Baseline Loads: 53.62
I hereby certify that the plans and specifications covered by
Review of the plans and
o�-T%E SrATF
this calculation are in compliance with the Florida Energy
Code.
specifications covered by this
calculation indicates compliance
�y ; ; 0
p
with the Florida Energy Code.
F mrrr'°-: • � •�.•:,,' ,� O
�
is
PREPARED BY:
DATE: " 7
Before construction completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
0
* �'
I hereby certify that this building, as designed, is in compliance
CDD
with the Florida Energy Code.
WE'D
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
ipiaance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
fled factory -sealed in accordance with R403.3.2.1.
pliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
)pe leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
9 2:13 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
CnDnn DAnF=')n17
IMDi IT ci IMMARY C'.141=r-KI HAT RFPORT
PROJECT
Title: Baptiste
Bedrooms: 6
Address Type:
Street Address
Building Type: User
Conditioned Area: 1214
Lot #
Owner Name: Merizer & Carole Baptiste
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
2805 Brantley Road
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
Fort Pierce,
Family Type: Single-family
FL,
New/Existing: Existing (Projected)
i
Comment:
i
j
CLIMATE
Design Temp
Int Design Temp Heating
Design Daily Temp
Vi Design Location TMY
Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1214 9712
SPACES
jNumber Name Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 Mech 96
768 No
0
1 Yes
Yes
Yes
2 Front room 204
1632 No
0
1 Yes
Yes
Yes
3 Kitchen 173
1384 Yes
1
1 Yes
Yes
Yes
4 Living 276
2208 No
0
1 Yes
Yes
Yes
5 Bath 45
360 No
0
1 Yes
Yes
Yes
6 Bed1 157
1256 No
1
1
1 Yes
Yes
Yes
7 Bed2 148
1184 No
1
2
1 Yes
Yes
Yes
8 Bed3 115
920 No
1
3
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
Mech 20 ft 0-
_
96 ft2
__-
1 0
0
2 Slab -On -Grade Edge Insulatio
Front room 29 ft 0
204 ft2
____
1 0
0
3 Slab -On -Grade Edge Insulatio
Kitchen 17.3 ft 0
172.5 ft2
_—_
1 0
0
4 Slab -On -Grade Edge Insulatio
Living 16 ft 0
276.3 ft2
1 0
0
5 Slab -On -Grade Edge Insulatio
Bath 5 ft 0
45 ft2
____
1 0
0
6 Slab -On -Grade Edge Insulatio
Bed1 25.3 ft 0
156.8 ft2
____
1 0
0
7 Slab -On -Grade Edge Insulatio
Bed2 24.5 ft 0
147 ft2
____
1 0
0
I
8 Slab -On -Grade Edge Insulatio
Bed3 loft 0
115 ft2
--
1 0
0
7/24/2019 2:13 PM
EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
I=nRRA Rdnria'7n17
INPIIT RUMMARY CHECKLIST REPORT
ROOF
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
Vi
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Gable or Shed Metal 1279 ft2
202 ft2
Light
N
0.6
No
0.9
No 0
18.4
ATTIC
JType
IRCC
Ventilation
Vent Ratio (1
in) Area
RBS
I
1
Full attic Vented
300
1214 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) Mech
30
Blown
96 ft2
0.1
Wood
2
Under Attic (Vented) Front room
30
Blown
204 ft2
0.1
Wood
3
Under Attic (Vented) Kitchen
30
Blown
173 ft2
0.1
Wood
4
Under Attic (Vented) Living
30
Blown
276 ft2
0.1
Wood
5
Under Attic (Vented) Bath
30
Blown
45 ft2
0.1
Wood
6
Under Attic (Vented) Bed1
30
Blown
157 ft2
0.1
Wood
7
Under Attic (Vented) Bed2
30
Blown
147 ft2
0.1
Wood
I
8
Under Attic (Vented) Bed3
30
Blown
115 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar Below
nmt
Space
10 Wall Type
1
N
Exterior Concrete Block - Int Insul Mach
5 8
0 8
0
64.0 ft2
0
0
0.5
0
2
W
Exterior Concrete Block - Int Insul Mech
5 12
0 8
0
96.0 ft2
0
0
0.5
0
3
N
Exterior Concrete Block - Int InsuFront room
5 17
0 8
0
136.0 ft2
0
0
0.5
0
4
E
Exterior Concrete Block - Int InsuFront room
5 12
0 8
0
96.0 ft2
0
0
0.5
0
5
W
Exterior Concrete Block - Int Insul Kitchen
5 17
3 8
0
138.0 ft2
0
0
0.5
0
6
E
Exterior Concrete Block - Int Insul Living
5 16
0 8
0
128.0 ft2
0
0
0.5
0
7
W
Exterior Concrete Block - Int Insul Bath
5 5
0 8
0
40.0 ft2
0
0
0.5
0
8
S
Exterior Concrete Block - Int Insul Bed1
5 11
0 8
0
88.0 ft2
0
0
0.5
0
9
W
Exterior Concrete Block - Int Insul Bed1
5 14
3 8
0
114.0 ft2
0
0
0.5
0
10
E
Exterior Concrete Block - Int Insul Bed2
5 10
6 8
0
84.0 ft2
0
0
0.5
0
11
S
Exterior Concrete Block - Int Insul Bed2
5 14
0 8
0
112.0 ft2
0
0
0.5
0
I
12
E
Exterior Concrete Block - Int Insul Bed3
5 10
0 8
0
80.0 ft2
0
0
0.5
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height Area
Ft
In
Ft
In
1
W Insulated Mech
None
.2
3
7
21 ft2
I
2
E Insulated Living
None
.2
3
7
21 ft2
I/24/2019 2:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FCIRM R,4n5•9nl7 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
# Omt ID Frame
Panes
NFRC
U-Factor SHGC Imp Area
Overhang
Depth Separation
Int Shade
Screening
1 E 4 Metal
2 W 5 Metal
3 W 5 Metal
4 E 6 Metal
5 W 7 Metal
6 S 8 Metal
7 W 9 Metal
8 E 10 Metal
1 9 S 11 Metal
10 E 12 Metal
I
Single (Clear)
Single (Clear)
Single (Clear)
Single (Clear)
Single (Clear)
Single (Clear)
Single (Clear)
Single (Clear)
Single (Clear)
Single (Clear)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.7 0.55 N 19.5 ft2
0.7 0.55 N 10.2 ft2
0.7 0.55 N 40.2 ft2
0.7 0.55 N 26.2 ft2
0.7 0.55 N 6.7 ft2
0.7 0.55 N 10.2 ft2
0.7 0.55 N 10.2 ft2
0.7 0.55 N 10.2 ft2
0.7 0.55 N 10.2 ft2
0.7 0.55 N 19.5 ft2
4 ft 0 in 1 ft 0 in
2 ft 0 in 1 ft 0 in
2 ft 0 in 1 ft 0 in
4 ft 0 in 1 ft 0 in
2 ft 0 in 1 ft 0 in
2 ft 0 in 2 ft 10 in
2 ft 0 in 1 ft 0 in
2 ft 0 in ,1 ft 0 in
2 ft 0 in 2 ft 10 in
2 ft 0 in 1 ft 0 in
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Exterior 5
Exterior 5
Exterior 5
Exterior 5
Exterior 5
Exterior 5
Exterior 5
Exterior 5
Exterior 5
Exterior 5
INFILTRATION
#
Scope Method
SLA
CFM 50 ELA EgLA
ACH ACH 50
1
i Wholehouse Proposed ACH(50) .000356
1133.1 62.2 116.98
.1233
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Strip Heat/
I
None
COPI 8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
I
Split
SEER: 15 33 kBtu/hr 1050 cfm
0.7 1
sys#1
HOT WATER SYSTEM
# System Type
SubTpe
Location
EF Cap Use
SetPnt
Conservation
1 Electric
I
None
Mech
0.95 40 gal 90 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
I
None None
ft2
DUCTS
-- Supply -
# Location R-Value Area
- Return - Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1 Attic
6 213 ft2
Kitchen
0 ft2 Default Leakage Mech
(Default) (Default)
1 1
9 2:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
r
FORM R4-05-2017
INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Piogramable Thermostat: Y
Ceiling Fans:
Coolin Jan Feb
Heating Jan Feb
[[ ]] Mar
[Mar
Apr
Apr
[
[
] May
] May
X Jun
Jun
Jul
rj Jul
X Au
Au
X Se
Sep
Oct [ ]
E Oct [X]
Nov
Nov
Dec
Dec
Ventin Jan
Feb
[X Mar
[X] A r
[
] Ma
[ Jun
Jul
Aug
[ Se
[X] Oct [X]
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
He Ming (WD)
PM
AM
78
78
78
78
78
78
78
78
78
78
78
78
68
68
68
68
68
68
68
68
68
68
66
66
He Iting (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
i
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Mech
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Front room
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Living
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bed1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bed2
Default(8 Ibs/s .ft.
ft2
ft
0.3
Bed3
9 2:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5