HomeMy WebLinkAboutproduct appFlorida Building Code Onlir�
Submit Surcharge Stats & Facts Publications ` Contact Us BCIS Site Map Links i Search
rUSERg Product Approval
y
: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Product Approval Method
FL2418-R11
Revision
2017
Approved
RECEIVED
AUG 96 2019
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Maxim Industries, Inc.
1630 Terre Colony Court
Dallas, TX 75212-6221
(214)905-2021
info@maximskylights.com
C�f -� OG65
David Thornton
C
info@maximskylights.com
REVIEWED F®R
CODE COMPLIANCE
S ! . LUCpIE COUNTY
®®CV
Sky Lights e " �
Skylight
t' Certification Mark or Listing
National Accreditation & Management Institute
National Accreditation & Management Institute
Standard
Year
TAS 201
1994
TAS 202
1994
TAS 203
1994
Florida Licensed Professional Engineer or Architect
FL2418 RS1 Eouiv EER2000 Rev2 418-0102 MAX0001-DSF MAX0002
DCM ss.Ddf
Method 1 Option A
Me Copy
Date Submitted
03/05/2018
_dtl.aspx?param--wGEVXQwtDgs1 UBZYvQ3nulYZKWMdraMaWKUDzvvObrMtEinMiFFkSRAai IdO4- I 411)
I
211/2919
Date Validated •
Date Pending FBC Approval
Date Approved
Summary of Products
r i
Florida Building Code Onlir�
03/06/2018
03/09/2018
FL *
Model, Number or Name
Description
2418.1
Series "DCM" Dade Curb Mount
Polycarbonate Glazed Aluminum Skylight
Skylight
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL2418 R11 C CAC NI009198.01-R5 DCM.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
12/31/2021
Design Pressure: +60/-60
Installation Instructions
Other:
FL2418 R11 II MAX0002 RevB DCM ss pdf
Verified By: Robert J. Amoruso, PE FL PE No. 49752
Created by Independent Third Party: Yes
Evaluation Reports
FL2418 R11 AE PER2000 Rev2 418-0102 MAX0001-
DSF MAX0002-DCM ss.pdf
Created by Independent Third Party: Yes
1
2418.2 I Series "DSF Dade Self Flashing
Skylight
Polycarbonate Glazed Aluminum Skylight
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +60/-60
Other:
Certification Agency Certificate
FL2418 R11 C CAC NI009198-115 DSFpd
Quality Assurance Contract Expiration Date
12/31/2021
Installation Instructions
FL2418 R11 II MAX0001 RevC DSF ss pdf
Verified By: Robert J. Amoruso, PE FL PE No. 49752
Created by Independent Third Party: Yes
Evaluation Reports
FL2418 R11 AE PER2000 Rev2 418-0102 MAX0001-
D,5F MAX0002-DCM Ss pd
Created by Independent Third Party: Yes
E"Izxt
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The state of Florida is an AA/EEO employer. QOpyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(i),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Departrnent with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click her. .
Product Approval Accepts:
® RR M
Credit •
Safe
securitymE`I'RIC'S
https•J%floridabuilding.org/pr/pr app dfl.aspx?param=wGEVXQwtDgslUBZYvQ3nulYZKWMdraMgWKUpzvyObrMtEioMjFe56A%3d%3d 2/2
I
MAXIM INDUSTRIES, INC.
SERIES "DCM" DADE CURB MOUNT SKYLIGHT
INSTALLATION ANCHORAGE DETAILS
GENERAL NOTES: INSTALLATION NOTES: 4" MAX. FROM
10,50" MAX.
a
1. THIS PRODUCT IS DESIGNED TO COMPLY WITH THE HIGH CORNERS TYP.
I. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH
D.C. TYP.
VELOCITY HURRICANE ZONE OF THE CURRENT ANCHOR LOCATION SHOWN,
c
EDITION OF THE FLORIDA BUILDINGLDING CODE (FBC). THE
i i
a
PRODUCT DETAILS CONTAINED HEREIN ARE BASED UPON 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED ARE �
SIGNED AND SEALED TEST REPORT ATI 01 43381.01 AND
(-
O
THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR �-
ASSOCIATED LABORATORY DRAWINGS. PRODUCT INSTALLATION. 4" MAX. FROM
5
2. ADEQUACY OF THE EXISTING STRUCTURAL FRAMING AS A 3. FOR INSTALLATION INTO WOOD ROOF DECK, USE #12 CORNERS TYP.
MAIN WINO
I I I
I
rn
FORCE RESISTING SYSTEM CAPABLE OF WOOD SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 1 318
WITHSTANDING AND TRANSFERRING APPLIED PRODUCT
I-
INCH MINIMUM EMBEDMENT. MINIMUM EDGE DISTANCE IS
LOADS TO THE STRUCTURE IS THE RESPONSIBILITY OF THE ,
1 INCH
�O
' U
3
U
ENGINEER OR ARCHITECT OF RECORD.
w w
,• f
3 m
4, MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE
3, IN AREAS WHERE WIND-BORNE DEBRIS PROTECTION WALL FINISHES, INCLUDING BUT NOT LIMITED TO
REQUIREMENTS EXIST USE
I I I
--� � n
= O X
F
m
?
i
OF AN APPROVED IMPACT STUCCO, FOAM, BRICK VENEER AND SIDING.
PROTECTIVE SYSTEM IS NOT REQUIRED,
U
----i
U z
10.50" MAX.
5. INSTALLATION ANCHORS SHALL BE INSTALLED IN
I I I
96"4�
I
pW q
aall
4. MATERIALS: D.C. TYP.
ACCORDANCE WITH ANCHOR MANUFACTURER'S
4.1. SKYLIGHT FRAME: 6063-T6 EXTRUDED ALUMINUM.
MAX.10Q8 " ❑
O.A.O,A, MAX
O
INSTALLATION INSTRUCTIONS AND ANCHORS SHALL
4.2. SKYLIGHT INNER AND OUTER DOME MATERIAL: NOT BE
I I
-
MAX.MAXI I FIXED O.A.
U 1-Ii
�' dy
USED IN SUBSTRATES WITH STRENGTHS LESS
MAKROLON POLYCARBONATE BY COVESTRO, LLC PER THAN
O.A.
CURB
p uj
,6
THE MINIMUM STRENGTH SPECIFIED BY THE
CURRENT MIAMI-DADE NOA COMPONENT APPROVAL. ANCHOR MANUFACTURER.
I I I
D.L.O.
LENGTH
I LENGTH LENGTH
W
W O
g
1��
Z
W
B. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS
I I
HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH
I
I
m� .9
THE FOLLOWING PROPERTIES:
8
A. WOOD - MINIMUM SPECIFIC GRAVITY OF 0.42.
TABLE OF CONTENTS
SHEET
REV.
SHEET DESCRIPTION
1
—
NOTES, ELEVATION 6 ANCHOR LAYOUT
2
—
SECTION VIEWS
DESIGN PRESSURE RATING (PSF)
IMPACT RATING
t60.0
LARGE MISSILE
IMPACT
1 1 1 1 1
48" MAX. O.A.
FIXED D.L.O. WIDTH
518" MAX. O.A.
CURB WIDTH
5216" MAX. O.A.
WIDTH
ELEVATION & ANCHOR
LAYOUT
L:A 1l:l\1 Vll Y1L-YV
Robert J. Ar .B., P.E.
Florida P.E. No. 49762
Digitally
signed by
.. ... Robert
p`O��,i N\de0>6i O,i O4i
3 9 Amoruso
b � .
A� BTA a aF ,�� Date:
2018.03.05
10:08:11
-05'00'
4.
5.
6.
7.
8.
9.
10.
11.
Minimum #12 fastener by others. Pre -punched installation holes 4" from each corner, maximum 10.5" on center. Minimum penetration = 1-3/811.
.060" X 1.5" X 1.75" 6063-T6 extruded aluminum retaining angle. Aluminum angle mitered and welded @ four corners.
52.5" X 100.375" UV Enhanced outer Makrolon Polycarbonate Dome by Covestro, LLC @ 8" height on test sample dome height varies per skylight size but not
less than the larger of 10% of the dome's span or 4'5 .
52.5" X 100.375" UV Enhanced inner Makrolon Polycarbonate Dome by Covestro, LLC @ 4" height on test sample ( dome height varies per skylight size but
not less than the larger of 10% of the dome's span or 415 .
OSI PR256 urethane sealant. Located between aluminum retaining angle and outer dome & between inner dome and aluminum frame.
Sealant tape. 1" X .125" located between outer and inner domes.
6063-T6 extruded aluminum frame. Aluminum frame mitered and welded @ four corners.
#12 X 1.75" fastener. One fastener located equidistant from each corner. Four fasteners per skylight.
#10 X .375 18-8 stainless steel fastener. Located 4" from each corner, maximum 11" on center.
All units equal to or less than the total square footage or the test specimen, 36 square feet, will be accepted under this -approval.
Minimum distance = 4" from angle lip to roof surface for shingles or BUR without insulation. For insulation and tile roof add tile height and insulation thickness to
the 4" minimum height.
0 ,060" Extruded Aluminum
Retaining Angle
OMinimum #12 wood screw with min.
1-3/8" embedment into substrate
receiving point. Installation holes 4"-
from each corner, maximum 10.5" on
center.
Design Pressure: 60psf +/-
I
Roof deck and framing by others. All e
roof details shall comply with _
Chapter 15 of the Current Edition
FBC and Chapter 9 of the Current
Edition FRC.
Outer Polycarbonate Dome O3
Inner Polycarbonate Dome
Sealant O
Sealant Tape
-Sealant O
— Condensation Gutter
Sealant O
1-3/8" Min.
Embedment
Curb Mount Model
0
SU
fY�
o
W
(L
�
g
o_
7
E
# 12 Stainless Steel Fastener with
U) N
W
U
Q
neoprene gasket. One fastener
1;; d
ca
0
located equidustant from each ®
c o
= w
o
W P
�R
corner. Four fasteners per
( P
skylight)
N
#10 X .375" stainless steel fastener@
4" from each corner, maximum 11
on center.
U)
11141"T
0,060" Aluminum Frame O �
N
RobM J. Amon o, P.S.
NoMa P.E. No. 49752
Digitally
signed by
, 11'"EB;'
: J� °a• N i
RobertJ
ao
Amoruso
el pp j�W�
Date:
�81
:aa ONA4 EN ��.
2018.03.05
10:08:31
-05,00,