HomeMy WebLinkAboutPRODUCT APPROVAL - 1 INCH NAILSTRIP 26GA STEELPalm City; FL. 34990
With Florida Building Code 2017 (6 h ed.) SCANNED
with Florida Product Approval Rule # 6100-3 BY
Keystone Certifications St Lucie Counts
1" Nailstrip 26GA Steel Standing Seam Roof Panel FBC Sec.1507.4.2
Yield strength: 40ksi: Attached to Wood Deck with screws.'
16". Coverage
ision Resistant Compliant: FBC Sec.1507.4.3
ner for Method 1 Attachment # 10 x 1" Pancake .Head wood screw to penetrate
' thru 15/32" min. plywood deck
i Adhesive: Bostik Chem Chalk 915, one component, polyurethane adhesive
male -flange the full length of panel.
rlayment: To be compliant with FBC Sec.1S07
Shall be in compliance with FBC Sec..1507 l.1
Install,
Details: Table A .. Allowable Loads
METHOD i main field
METHOD 2 perimeter
DESIGN
PRESSURES .
-69,2S PSF
-121.75 PSF
FASTENER
SPACING -ALONG ROWS
W O.C.
6" O.C.
FASTENER
SIZE:
#10
#10
ADI#EISIVE
NOT REQUIRED
3/9 BEAb (refer to
instofi detuiis) .
Reference Data: HURRICANE TEST LABORATORY, L.L.C. #TST I0:1S27
Drt#:0223-0313-02 TAS125-03(m mo-o&m -t897-041)
art#: 0223-1015-06: TAS125-03(ucsso-o6luL i897W)
IALENLY: UL 1897-04 6 EQUAWENT TO UL 289712 TEST STANDARD *DESIGN PRESSURE MARGIN OF SAFETY27
icate of Independence:.
Bowden, P,E. does not have,'not will acquire a financialinterest lN#nV'i:bffi A6V rfianufactu
this evaluation. C�! ,,�
Bowden, P.E. is not owned, operated, or controlled by any On}gany;agltfeCiyte�,,distc;
or distributing products
ing products under this
I
FL 20378.2 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed..
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
3. Produ6ts are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
Fastr..
ALVac vdvvULAt:%n (Rder to TONO -A-)
integral Snap Lock
.Seam Adlwslve
Apply 3J8`° bead Bostik Sealant
entire length of panel
along mate Range
#10xi-
• Pancake -Head Screw