Loading...
HomeMy WebLinkAboutSITE PLANSlftfflRA SITE PLAN FOR HARBOUR RIDGE. LTD. LEGAL DESCRIPTION: UNIT 41. BUTTONBUSH VILLAGE (AREA VB3-VB4). HARBOUR RIDGE PLAT NO 13, ACCORDING TO THE PLAT THEREOF RECORDED IN PLAT BOOK 28 , PAGES 3A -3H • ST. LUCIE COUNTY. FLORIDA. UNIT 42 o, 40, S6' E 121. 75' $ 1 U UNIT 4i $ I a PROPOSED oraM BUILDING 3a•�I t e MIN. SETBACK REQ. FRONT Un �� SIDES- as CNR SIDES, jam._ -. _--- REAR ZNG.-�„ TECH._._ c `12• U. E. UNIT 40 , 01O t SCANNED i3Y St Lucie County ti ELEVATIONS SHOWN THUSLY 4�ti MODEL PORTOF I NO F IN I SHED FLOOR i 2. 0 REFER TO N. G. V. 0. 1929. ADDRESS: i3308 MAPLEWOOD ROAD , PALM CITY, FLORIDA 33490 THE DEVELOPMENT ORDER FOR THIS HARBOUR RIDGE PLANNED DEVELOPMENT PROJECT AS IT APPLIES TO TRACT V83-VB4. PLAT NO.i3 HARBOUR RIDGE, REQUIRES A MINIMUM DISTANCE OF 30.00 FEET BETWEEN BUILDINGS. THERE IS NO SIDE YARD SETBACK REQUIREMENT. ' DOCK, ROOS & ASSOCIATES, INC. laZ N/A ENGINEERS • SURVEYORS • PLANNERS um TMS �__...._ _ql%* Al ! BEST PALM BEACH, FLORIDA CH Prepared for HARBOUR A I DM LTD. T A SURVEY scks 1" -40' OATI~APR 1990 P. L 90. 89-132 aa. No. A— 2132 F GENERAL NOTES ---1: DESIGN -CRITERIA: - - - -- -- ALUMINUM -SPECIFICATIONS- - - APPLICABLE CODES, REGULATIONS & STANDARDS: 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS 1. THE 2017 FLORIDA BUILDING CODE, 6TH EDITION SPECIFICALLY OTHERWISE SPECIFIED. CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH CHAPTER 23 WOOD. #12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. 2. ASCE 7-10. & SEI7 3. ROOF BRACING SHALL BE A MINIMUM 2"X2"X.050". 3. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS 4. AC1318 CONCRETE REFRENCE MANUAL. INCHEPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 5. PCI PRECPSJ_&_P_RESTRESS.ED_C_ONCRET_E INCHES. 6. AA ASM 35 & AA ADM 1 S VfNYL AND ACRYLIC -PANELS SHaLI:--BE REMOVED -WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. WIND LOADS: 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 &TABLE APPROVED BY FLORIDA ENGINEERING LLC. 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: C 3. SCREENED ROOF ENCLOSURE FBC 2017 CH. 20 TABLE 2002.4 CONCRETE & FOUNDATION DESIGN: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: A. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: I. PORTLAND CEMENT TYPE 1 - ASTM C 150 II. AGGREGATES - LARGE AGGREGATE 3/4" MAX. - ASTM C 33 III. AIR ENTRAINING +/- 1% - ASTM C 260 IV. WATER REDUCING AGENT - ASTM C 494 V. CLEAN POTABLE WATER VI. OTHER ADMIXTURES NOT PERMITTED B. METAL ACCESSORIES SHALL CONFORM TO: I. REINFORCING BARS -ASTM A615, GRADE 60 II. WELDED WIRE FABRIC - ASTM A185 C. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. D. PREPARE. & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. E. MOIST CURE OR POLYETHYLENE CURING PERMITTED. F. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE FBC. G. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. 2. FOOTING SIZE: EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB (3000 PSI) IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM 8"x8" W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. 3. WHEN APPLICABLE FOR ATTACHING NEW FO.OTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS. 4. WHEN INSTALLING 4" CONCRETE SLAB -ADD ADJACENT TO EXISTING-DOWELL INTO EXISTING CONCRETE 48" O/C W/8" #5 REBARS- DRILL 3/4" HOLE 4" EMBEDMENT- EPDXY W/ NON -SHRINKING "SIMPSON EPDXY TIE" (OR EQUAL). 5. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHER WISE NOTED. FASTNER SPECIFICATIONS: 1. FASTNERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS -OR BETTER, INSTALLED TO MFG.) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, AND FASTENERS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1/4':X3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1 "X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1/4"X2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE #14X2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE #10X1-1/2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE VX2" INSTALLED THROUGHOUT AN "OPEN VIEW" SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS MASONRY SPECIFICATIONS: 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3i8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. MISCELLANEOUS: i N O File Copy W R I D 1 51019 e N CODE COMPLIANCE�90 "Pa ST. LUC2E COUN �y rn w 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND INSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTUALLY SOUND. 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 4. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. 6. ALL 2X4 & GREATER ARE TO BE SMB UNLESS OTHERWISE INDICATED RESPONSIBILITIES: 1. ALL SITE WORK SHALL BE PERFORMED BY A LISCENED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. LEGEND: (ALL MAY NOT APPLY) SCR = SCREEN KP = KICK PLATE PW = PICTURE WINDOW X = HORIZ. SLIDING WINDOW O = HORIZ. STATIONARY WINDOW DH = DOUBLE HUNG WINDOW SH= SINGLE HUNG WINDOW SIP = SOLID INSULATED PANEL CT = CABLE TIE SG = SUPER GUTTER CS = CLEAR SPAN KB = KNEE BRACE ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2"x2"x0.044" 2 x 3: 2"x3"x0.044" 2 x 4: 2"x4"x0.044" 2 x 5: 2"x5"0.050" OPEN BACK SECTIONS 1 x 2: 1 "x2"x0.044" 1 x 3: 1 "x3"x0.044" SNAP SECTIONS 2 x 2 SNAP: 2"x2"0.050" 2 x 3 SNAP: 2"x3"x0.050" 2 x 4 SNAP: 2"x4"0.045" SELF MATING (SMB) 2 x 4 SMB: 2"x4"x0.044"x0.100 2 x 5 SMB: 2"x5"x0.050"x0.100" 2 x 6 SMB: 2"x6"x0.050"x0.120" 2 x 7 SMB: 2"x7"x0.057"x0.120" 2 x 8 SMB: 2"x8"0.072"0.124" 2 x 9 SMB: 2"x9"0.082"4.124" 2 x 10 SMB: 2"x10"x0.092"x0.398" NOTE: AS INDICATED ABOVE ALL MEMBER PROFILES ARE INDICATED IN INCHES. SGANN S) Sy St Ludic County J m q co m rn� V ~ co Zzp o U � U O _ W "V`� 0 � W _` LL L L z10y W ,V-- N M z LL) 0�� of 0) Q 0 Q U c LO LL N W rl- M w U U O rn rnvl- U J � W 0 w J � w u- J d� w Q2U W. Z o ao a C) M w ��li DESIGN DATE: 07/11/2019 REVISION 1: DATE PAGE: REVISION 2: DATE SCALE: NTS 1 12'-611 2X3 0 I rn 2X5SMB N X m X W W L I- N jx N K C UD 70 --o n 2X5SMB W rn rn 2X3 0 T , ]] 1 '1 CID t J r ' �'� 0 x_ M • m c 0 ,•5 (n M 70 0 GUN I KAI: I UK: m 5 PIONEER SCREEN, LLC. 0 Z N o Z � Z 0 � m Z co m D1 m o .1 PROJEOTADDRESS: N 8 MURRAY 13308 MAPLEWOOD DR N D m PALM CITY, FL 1X2 4'-211 3X2 1X2 X N NJ NJ �p N � I 3X2 3X2 3X2 1X2 UNDER TRUSS 1'-0" 01H i i w � I T' 0 W I D �I � v X I 0 i-I o of U-1 N m Oi �-1 I -v X i =I �D� ID I r m W i O 1 IC iz UNDER TRUSS 3X2 N 3X2 X N N N N X X W W 3X2 1X2 --41-211� f FLORIDA ENGINEERING LLC 4456 TAMIAMI TRAIL, UNIT B14 J I PORT CHARLOTTE, FLORIDA 33980 (941) 391-5980 www.fiengineeringlic.com ' Craig E. Gu erson, P.E. #60102 PROJECT NO. 1919011 CA CERT. #30782 p,TE: 07/11/2019 .024 FLASHING SEALED TO - - -- - - --WALL (TYP.) 0 ° 0 0 0 0 #12x3/4" SMS @ 12' O.C. TOP 8 BOTTOM FOR COMPOSITE s OR (3) PER PAN .050-3" RECEIVING CHANNEL CONCRETE OR FILLED FASTEN TO MASONRY WALL MASONRY W/ 1/4" X 3" TAPCONS 18' O/C (INTERNAL) FOR ALUMINUM PANS: 1/4" X 2" TAPCON (OR EQUAL) w/ 5/8" NEO-WASHER THROUGH BOX END OF PAN ROOF PANEL ATTACHMENT -MASONRY SCALE: N.T.S. NOTE: IF PAVERS ARE PRESENT,CONCRETE ANCHORS SHALL PENETRATEINTO FOOTING 2-I/4" MIN. (TYP. NOTE: WHEN FASTENING TO WOOD USE 1/4° GALV. LAG SCREW IN LIEU OF CONC. ANCHORS AND ENSURE PENETRATION MIN 2-1/4" INTO , STRUCTURAL FRAMING BENEATH (TYP.) 1/4" DIA. TAPCON SCHEDULE UPRIGHT QTY. TAPCON/ QTY. #12 SMS E/S 2X3 (1) 1/4" TAPCON/ (4) #12 2X4 (2) 1/4" TAPCON/ (4) #12 2X5 (2) 1/4" TAPCON/ (4) #12 2X6 (3) 1/4" TAPCON/ (6) #12 2X7 (3) 1/4" TAPCON/ (6) #12 2X8 (4) 1/4" TAPCON/ (8) #12 2X9 (4) 1/4" TAPCON/ (8) #12 2X10 (5) 1/4" TAPCON/ (10) #12 EXISTING RAFTER OR TRUSS O C 0 C #12x3/4" SMS @ 12" O.C. TOP S BOTTOM FOR COMPOSITE OR (3) PER PAN .050 X 3'U-HEADER 2" NOMINAL STRUCTURAL FASCIA MIN. FOR COMPOSITE PANELS: (2). #12 X-2. MR THROUGH RECEIVING CHANNEL @ 12" O.C. ALTERNATELY: FOR ALUMINUM PANS: (1) I/4"x3' LAG BOLT #12 X 2° SMS THROUGH THROUGH RECEIVING "BOXED END": INTO WD FASCIA CHANNEL @ 12" O.C. ROOF PANEL ATTACHMENT - WOOD FRAME SCALE: N.T.S. 3/8" DIA. TAPCON SCHEDULE UPRIGHT QTY. TAPCON/ QTY. #12 SMS E/S 2X3 (1) 3/8" TAPCON/ (4) #12 2X4 (2) 3/8" TAPCON/ (4) #12 2X5 (2) 3/8" TAPCON/ (4) #12 2X6 (2) 3/8" TAPCON/ (6) #12 2X7 (2) 3/8" TAPCON/ (6) #12 2X8 (3) 3/8" TAPCON/ (6) #12 2X9 (3) 3/8" TAPCON/ (6) #12 2X10 (4) 3/8" TAPCON/ (8) #12 NOTE: ANGLE REQUIRED SCHEDULE BASED ON 2-1/4" MIN. SCHEDULE BASED ON 2-1/4" MIN. ONE SIDE ONLY FOR CONCRETE ANCHOR EMBEDMENT CONCRETE ANCHOR EMBEDMENT DOOR JAMBS (TYP.) SELF -MATING OR I/8"x2"x2"x ANGLE SNAP SECTION TYP. 5032 H-32 ANGLE PER PLAN 1"x2" O.B. BASE PLATE-TYP. 2 - #12 SMS INTO COLUMN I/4° MASONRY ANCHOR EACH o 0 2-I/4" MIN. CONC: ANGLE - EACH SIDE COL. ° ° ANCHOR EMBEDMENT ° ° ° 2' MIN. ANCHOR SPACING WHEN GREATER THAN 2x4 UPRIGHT IS USED SEE d ° n TAPCON SCHEDULE ABOVE 3000 PSI CONC. d SLAB/ FTG. 6x6-IOx10 WWM SIDE VIEW OR FIBERMESH 1/4" MASONRY ANCHOR AT EACH ANGLE 2 - #12 SMS 1/4" TAPCON XL (RED HEAD MFG. OR EQUAL) 2 @ Ix2 BASE 2 @ SLAB (BEYOND) 8 I"x2" BASE PLATE ANCHORED TO CONC w/ 1/4" MASONRY ANCHOR 6" MAX EACH SIDE • ° OF POST AND 24" O.C. MAX 6" 3000 PSI CONC. SLAB/ FTG. 6x6-10x10 WWM FRONT VIEW OR FIBERMESH 2"xY OR LARGER UPRIGHT TO DECK DETAILS ,,SCALE: N.T.S. FOR ALUMINUM PANS OR GALVALUME STEEL PANS USE #12 X 9/16" W/ 5/8" NEO-WASHER (3) PER PAN FOR COMP. PANELS #12 X I° LG. THAN PANEL THICKNESS SMS W/ 1-112" NEO-WASHER 12" O/C (4) PER PANEL O O O CARRIER BEAM 0 O #14x3/4" SMS "Mui (2) 318" DIA. QUANTITY - BEAM SIZE_ MACHINE BOLTS THRU_ _ THRU REC. INTO POST REC. CHANNEL 8 POST IN LIEU OF #14 SMS ROOF BEAM O (SLOPED OR FLAT) O O CARRIER BEAM O POST - ,— s14x3/4L SMS , "(S,tt t AUt-4 QUANTITY = BEAM SIZE FOR SIZE) (TYP. EACH SIDE) *'MAY USE: (2) 3/8" DIA. MACHINE BOLTS THRU REC. CHANNEL 8 BEAM IN LIEU OF #14 SMS BEAM TO COLUMN CONNECTION DETAIL SCALE: N.T.S. .OVER END OF PANEL CARRIER BEAM (SEE PAGE-2 FOR SIZE) 14" DIA. MACHINE BOLTS 14" DIA. WASHERS THRU tIER BEAM 8 POST 'IONALEXTRUDED GUTTER IS 4CHED TO 3" INSULATED ROOF 12x1" 6° FROM ENDS 24' O.C. ROOF PANEL TO CARRIER BEAM CONNECTION SCALE: N.T.S. HOST ROOF PER PLAN 1 REVIEWED FOR '110-'ODE COMPLIANCE LUCRE COUNTY BOCC SCANNED CountyBY St Lucie 2"X -- PER PLAN ATTACH TO ROOF PANELS W/#12 SMS 120 O/C 6" FROM ENDS I" EMBEDMENT (MIN.) REVIEWED FOR '110-'ODE COMPLIANCE LUCRE COUNTY BOCC SCANNED CountyBY St Lucie 2"X -- PER PLAN ATTACH TO ROOF PANELS W/#12 SMS 120 O/C 6" FROM ENDS I" EMBEDMENT (MIN.) N O O W � C a -I c 9 � 0UU U o J m _J 00 rn r n co Z Z ap o —:3 0� U U w 000- W U-Lo Z -�- 0 M C: W Q r T U L.1.. (.C) Ily- Y / LL LL N 00 t` O LU U U ALUMINUM INTERNAL OR EXTERNAL V ALTERNATES FOR COL. / RECEIVING CHANNEL W/(4) #10x.75" INTO GIRT OR PURLIN 8 (2) #14x.75" TO 20X-0 AT HEADER: EDGE BEAM BEAM INTO BEAM OR UPRIGHT 0.062 ANGLE I- DETAIL "C" SHT 3 2- (4) # 10 X 30 SMS (2) I/4° THRU-BOLT CLIPS MAYBE USED (4) #IOx2'SMS INTO THROUGH MEMBER ABOVE COL SCREW BOSS 'ALSO COL /EDGE SCREW BOSSES CH COL. TO RECEIVE BEAM ALTERNATES (THIS PAGE) U BEAM FASTEN W/ J Q (2) 00 THRU-BOLT COL. PER PLAN I"X2° FASTEN TO W O CHAIR RAIL PER PLAN ADJOINING WALL ADJOINING BEARING WALL W/#12 X I-1120 —1SMS @ 18° O.C. U W LL Ole PURLIN 1/4"X2-3/4" TAPCONS J UPRIGHT, BEAM -SNAP, MEMBER OR EQUAL AT 24" O.C. AND 6"FROM ENDS } Q SELF MATING, OR HOLLOW W LUcc Q G U WHERE KICK PLATE IS INDICATED 00 W W FASTEN W/ #10 X 9/16" SMS � 8° O/C AT PERIMETER H.- Z Q w O J d w d z DETAIL "C„ GIRT OR PURLIN TO BEAM O a - ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, OR POST DETAIL SCALE: N.T.S. TAPCON (RED HEAD MFG. OR EQUAL) 6° FROM ENDS 24° O.C. DESIGN DATE: 07/11/2019 COLUMN I-I/4° PENETRATION INTO UNDERLYING FOOTING CO REVISION 1: DATE PAGE: TYP. SCREEN ROOM END WALL REVISION 2: DATE SCALE: N.T.S. SCALE: NTS r �doa VA 3 07 File COW