HomeMy WebLinkAboutENERGY EFFICIENCY CODE'FORM 60OA-2001
FLORIDA ENERGY E I�C1 =NC Y%T
FOR BUILDING C Mac
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: New Projei*�LOURAN°SUSANA 4�1200FMOEL2a�, Builder: LOURAN
Address: Permitting Office:
City,i�State: , Permit Number: v S0�Z "!S
Owner: Jurisdiction _Number:
Climate Zone: Central
1. New construction or existing New _ 12.. Cooling systems
2. Single family or multi -family Single family _ a. Central Unit Cap: 30.0 kBtu/hr
3. Number of units, if multi -family 1 _ SEER 12.00 _
4. Number of Bedrooms 3 _ b. N/A _
5. Is this a worst case.?. - Yes
6. Conditioned floor area (ft2) 1200 ft2 c. N/A01?
7. Glass area & type Single Pane Double Pane _ ,�
a. Clear glass, default U-factor 0.0 ft2 0.0 ft2 _ 13. satin s S
b. Default tint 125.0 ft2 0.0 ft2 _ a. 1 o eat P3 Cap: 27.0 kBtu/hr _
c. 'Labeled U or SHGC 0.0 ft2 0.0 ft2 HSPF: 6.80
8. Floor types _ b. N/A _
a. Slab -On -Grade Edge Insulation R=0.0, 178.0(p) ft _
b. N/A _ c. N/A _
c. N/A _
9. Wall types _ 14. Hot water systems
a. Concrete, Int Insul, Exterior R=4.1, 998.0 ft2 _ a. Electric Resistance Cap: 40.0 gallons
b. Frame, Wood, Adjacent R=11.0, 261.0 ft2 _ EF: 0.90
c. N%A _ b. N/A _
d. N%A
e. N%A c. Conservation credits _
10. Ceiling types _ (HR Heat recovery, Solar
a. Under Attic R=19.0, 1310.0 ft2 _ DHP-Dedicated heat pump)
b. N1A _ 15. HVAC credits CF, _
c. N/A (CF-Ceiling fan, CV -Cross ventilation,
11. Ducts _ HF-Whole house fan,
a. Sup: Unc. Ret: Unc. AM Garage Sup. R=6.0, 135.0 ft _ PT -Programmable Thermostat,
b. N/A MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.10 Total as -built points: 19214 PASS
Total base points: 19523
I hereby certify that the plans and specifications covered
by this! calculation are in compliance with the Florida
Energy Code. JL -�-
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in
compliance with the Flo E r�gvC e.
OWNER/AGE T:
DATE: / b
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
EnergyGauge® (Version: FLRCSB v3.30)
FORM 60OA-2001
i
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
BASE
AS-
-1T
GLASS TYPES
.18 X Conditioned
X BSPM = Points
Overhang
Floor Area
Type/SC
Ornt
Len Hgt Area X SPM X SOF = Points
.18 1200.0 25.78 5568.5
Single, Tint
W
1.0 6.0
30.0
47.90 0.97
1394.2
Single, Tint
W
1.0 8.0
15.0
47.90 0.99
712.1
Single, Tint
E
11.0 8.0
41.0
53.27 0.46
1001.4
Single, Tint
E
11.0 4.0
9.0
53.27 0.36
174.0
Single, Tint
E
1.0 6.0
15.0
53.27 0.97
775.4
Single, Tint
E
1.0 6.0
15.0
53.27 0.97
775.4
As -Built Total:
125.0
4832.6
WALL TYPES
Area X BSPM =
Points
Type
R Value Area
X, SPM =
Points
Adjacent
261.0 0.70
182.7
Concrete, Int Insul, Exterior
4.1
998.0
1.18
1177.6
Exterior
998.0 1.90
1896.2
Frame, Wood, Adjacent
11.0
261.0
0.70
182.7
Base total:
1259.0
2078.9
As -Built Total:
1259.0
1360.3
DOOR TYPES
Area X BSPM =
Points
Type
Area
X SPM =
Points
Adjacent
19.0 1.60
30.5
Exterior Insulated
20.4
4.80
97.9
Exterior
i
20.4 4.80
97.9
Adjacent Wood
19.0
2.40
45.7
Base Total:
39.4
128.4
As -Built Total:
39.4
143.6
CEILING TYPES Area X BSPM =
Points
Type
R-Value
Area X SPM X SCM =
Points
Under Attic
1200.0 2.13
2556.0
Under Attic
19.0
1310.0 2.82 X 1.00
3694.2
Base Total:
1200.0
2556.0
As -Built Total:
1310.0
3694.2
FLOOR TYPES
Area X BSPM =
Points
Type
R Value Area
X SPM =
Points
Slab
178.0(p) -31.8
-5660.4
Slab -On -Grade Edge Insulation
0.0
178.0(p
-31.90
-5678.2
Raised
0.0 0.00
0.0
Base Total:
-5660A
As -Built Total:
178.0
-5678.2
INFILTRATION
Area X BSPM =
Points
Area X SPM =
Points
1200.0 14.31
17172.0
1200.0
14.31
17172.0
EnergyGauge® DCA Form 60OA-2001
EnergyGauge®/FIaRES'2001 FLRCSB v3.30
i
FORM 60OA-2001
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
Summer Base Points:
21843.4
Summer As -Built Points:
21524.5
Total Summer
X System
= Cooling
Total X
Cap
X Duct X System X
Credit
= Cooling
Points
Multiplier
Points
Component
Ratio
Multiplier Multiplier
Multiplier
Points
(DM x DSM x AHU)
21,843.4
0.4266
9318.4
21524.5
1 21524.5
1.000
1.00
(1.087 x 1.150 x 1.00) 0.284
1.250 0.284
0.950
0.950
7263.7
7263.7
�I
Energy i auge7m DCA Form 60OA-2001
EnergyGauge®lFIaRES'2001 FLRCSB v3.30
i
FORM 60OA-2001
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
AS -BUILT
FBASE
PESditioned
X BWPM = Points
Overhang
Floor Area
Type/SC
Omt
Len Hgt
Area X WPM X WOF = Pointc
.18 1200.0 5.86 1265.8
Single, Tint
W
1.0 6.0
30.0 13.80 1.00
414.8
Single, Tint
W
1.0 8.0
15.0 13.80 1.00
206.8
Single, Tint
E
11.0 8.0
41.0 13.04 1.22
652.5
Single, Tint
E
11.0 4.0
9.0 13.04 1.32
154.8
Single, Tint
E
1.0 6.0
15.0 13.04 1.01
197.2
Single, Tint
E
1.0 6.0
15.0 13.04 1.01
197.2
As -Built Total:
125.0
1823.4
WALL TYPES
Area X BWPM =
Points
Type
R-Value
Area X WPM =
Points
Adjacent
261.0 1.80
469:8
Concrete, Int Insul, Exterior
4.1
998.0 3.31
3298.4
Exterior
I
998.0 2.00
1996.0
Frame, Wood, Adjacent
11.0
261.0 1.80
469.8
Base Total:
1269.0
2465.8
As -Built Total:
1259.0
3768.2
I
DOOR TYPES
Area X BWPM = Points
Type
Area X WPM =
Points
Adjacent
19.0 4.00
76.2
Exterior Insulated
20.4 5.10
104.0
Exterior
I
20.4 5.10
104.0
Adjacent Wood
19.0 5.90
112.3
I
Base Total:
39.4
180.2
As -Built Total:
39.4
216.4
CEILING TYPES Area X BWPM =
Points
Type
R-Value Area X WPM X WCM =
Points
Under Attic
1200.0 0.64
768.0
Under Attic
19.0
1310.0 0.87 X 1.00
1139.7
I
Base Total:
1200.0
768.0
As -Built Total:
1310.0
1139.7
I
FLOOR TYPES
Area X BWPM =
Points
Type
R-Value
Area X WPM =
Points
Slab
178.0(p) -1.9
-338.2
Slab -On -Grade Edge Insulation
0.0
178.0(p 2.50
445.0
Raised
I
0.0 0.00
0.0
Base Total:
-338.2
As -Built Total:
178.0
445.0
INFILTRATION
Area X BWPM
Points
Area X WPM =
Points
,
I
1200.0 -0.28
-336.0
1200.0 -0.28
-336.0
I
EnergyGauge® DCA Form 60OA-2001 EnergyGaugeOlFlaRES'2001 FLRCSB v3.30
FORM 60OA-2001
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
Winter Base Points:
=05.
=inter -Built Points:
7056.7
Total Winter
X System =
Heating
Total X
Cap
X Duct X System X
Credit =
Heating
(Points
Multiplier
Points
Component
Ratio
Multiplier Multiplier
Multiplier
Points
(DM x DSM x AHU)
7056.7
1.000
(1.078 x 1.160 x 1.00) 0.502
1.000
4429.0
4005.E
0.6274
2513.1
7056.7
1.00
1.250 0.502
1.000
4429.0
I
I,
I
EnergyGaugeTM DCA Form 60OA-2001 EnergyGauge®/FIaRES'2001 FLRCSB v3.30
I
i
FORM 60OA-2001
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
I ADDRESS: , , , PERMIT #: I
BASE
AS -BUILT
WATER HEATING
Number of X Multiplier
= Total
Tank EF
Number of X Tank X Multiplier X Credit = Total
Bedrooms
Volume
Bedrooms Ratio Multiplier
1 3 2564.00
7692.0
40.0 0.90
3 1.00 2507.02 1.00 7521.1
As -Built Total:
7521.1
CODE- COMPLIANCE STATUS
BASE
AS -BUILT
Cooling +
Points
i.
Heating +
Points
Hot Water = Total
Points Points
Cooling + Heating + Hot Water = Total
Points Points Points Points
9318
2513
7692 19523
7264 .. 4429 7521 19214
PASS
Energy IGaugeTM' DCA Form 60OA-2001 EnergyGauge®/FIaRES'2001 FLRCSB v3.30
FORM 60OA-2001
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1.ABC.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfrn/s .ft. door area.
Exterior & Adjacent Walls
606.1.ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from and is sealed to the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >1/8" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the pedmeter, penetrations and seams.
Ceilings
606.1 ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
606.1 ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
i
R0:99 nwim PRFSCRIPTIVF MFOSIIRFS /must hp me+ nr exceeded by all residences-1
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit
breaker electric or cutoff as must be provided. Extemal or built-in heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficiency of 78%.
Shover heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Separate readily accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
I
EnergyGauge"A DCA Form 60OA-2001 EnergyGaugeOlFlaRES'2001 FLRCSB v3.30