Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE'FORM 60OA-2001 FLORIDA ENERGY E I�C1 =NC Y%T FOR BUILDING C Mac Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: New Projei*�LOURAN°SUSANA 4�1200FMOEL2a�, Builder: LOURAN Address: Permitting Office: City,i�State: , Permit Number: v S0�Z "!S Owner: Jurisdiction _Number: Climate Zone: Central 1. New construction or existing New _ 12.. Cooling systems 2. Single family or multi -family Single family _ a. Central Unit Cap: 30.0 kBtu/hr 3. Number of units, if multi -family 1 _ SEER 12.00 _ 4. Number of Bedrooms 3 _ b. N/A _ 5. Is this a worst case.?. - Yes 6. Conditioned floor area (ft2) 1200 ft2 c. N/A01? 7. Glass area & type Single Pane Double Pane _ ,� a. Clear glass, default U-factor 0.0 ft2 0.0 ft2 _ 13. satin s S b. Default tint 125.0 ft2 0.0 ft2 _ a. 1 o eat P3 Cap: 27.0 kBtu/hr _ c. 'Labeled U or SHGC 0.0 ft2 0.0 ft2 HSPF: 6.80 8. Floor types _ b. N/A _ a. Slab -On -Grade Edge Insulation R=0.0, 178.0(p) ft _ b. N/A _ c. N/A _ c. N/A _ 9. Wall types _ 14. Hot water systems a. Concrete, Int Insul, Exterior R=4.1, 998.0 ft2 _ a. Electric Resistance Cap: 40.0 gallons b. Frame, Wood, Adjacent R=11.0, 261.0 ft2 _ EF: 0.90 c. N%A _ b. N/A _ d. N%A e. N%A c. Conservation credits _ 10. Ceiling types _ (HR Heat recovery, Solar a. Under Attic R=19.0, 1310.0 ft2 _ DHP-Dedicated heat pump) b. N1A _ 15. HVAC credits CF, _ c. N/A (CF-Ceiling fan, CV -Cross ventilation, 11. Ducts _ HF-Whole house fan, a. Sup: Unc. Ret: Unc. AM Garage Sup. R=6.0, 135.0 ft _ PT -Programmable Thermostat, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.10 Total as -built points: 19214 PASS Total base points: 19523 I hereby certify that the plans and specifications covered by this! calculation are in compliance with the Florida Energy Code. JL -�- PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Flo E r�gvC e. OWNER/AGE T: DATE: / b Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: EnergyGauge® (Version: FLRCSB v3.30) FORM 60OA-2001 i SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details BASE AS- -1T GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 1200.0 25.78 5568.5 Single, Tint W 1.0 6.0 30.0 47.90 0.97 1394.2 Single, Tint W 1.0 8.0 15.0 47.90 0.99 712.1 Single, Tint E 11.0 8.0 41.0 53.27 0.46 1001.4 Single, Tint E 11.0 4.0 9.0 53.27 0.36 174.0 Single, Tint E 1.0 6.0 15.0 53.27 0.97 775.4 Single, Tint E 1.0 6.0 15.0 53.27 0.97 775.4 As -Built Total: 125.0 4832.6 WALL TYPES Area X BSPM = Points Type R Value Area X, SPM = Points Adjacent 261.0 0.70 182.7 Concrete, Int Insul, Exterior 4.1 998.0 1.18 1177.6 Exterior 998.0 1.90 1896.2 Frame, Wood, Adjacent 11.0 261.0 0.70 182.7 Base total: 1259.0 2078.9 As -Built Total: 1259.0 1360.3 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 19.0 1.60 30.5 Exterior Insulated 20.4 4.80 97.9 Exterior i 20.4 4.80 97.9 Adjacent Wood 19.0 2.40 45.7 Base Total: 39.4 128.4 As -Built Total: 39.4 143.6 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 1200.0 2.13 2556.0 Under Attic 19.0 1310.0 2.82 X 1.00 3694.2 Base Total: 1200.0 2556.0 As -Built Total: 1310.0 3694.2 FLOOR TYPES Area X BSPM = Points Type R Value Area X SPM = Points Slab 178.0(p) -31.8 -5660.4 Slab -On -Grade Edge Insulation 0.0 178.0(p -31.90 -5678.2 Raised 0.0 0.00 0.0 Base Total: -5660A As -Built Total: 178.0 -5678.2 INFILTRATION Area X BSPM = Points Area X SPM = Points 1200.0 14.31 17172.0 1200.0 14.31 17172.0 EnergyGauge® DCA Form 60OA-2001 EnergyGauge®/FIaRES'2001 FLRCSB v3.30 i FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS -BUILT Summer Base Points: 21843.4 Summer As -Built Points: 21524.5 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) 21,843.4 0.4266 9318.4 21524.5 1 21524.5 1.000 1.00 (1.087 x 1.150 x 1.00) 0.284 1.250 0.284 0.950 0.950 7263.7 7263.7 �I Energy i auge7m DCA Form 60OA-2001 EnergyGauge®lFIaRES'2001 FLRCSB v3.30 i FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: AS -BUILT FBASE PESditioned X BWPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X WPM X WOF = Pointc .18 1200.0 5.86 1265.8 Single, Tint W 1.0 6.0 30.0 13.80 1.00 414.8 Single, Tint W 1.0 8.0 15.0 13.80 1.00 206.8 Single, Tint E 11.0 8.0 41.0 13.04 1.22 652.5 Single, Tint E 11.0 4.0 9.0 13.04 1.32 154.8 Single, Tint E 1.0 6.0 15.0 13.04 1.01 197.2 Single, Tint E 1.0 6.0 15.0 13.04 1.01 197.2 As -Built Total: 125.0 1823.4 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 261.0 1.80 469:8 Concrete, Int Insul, Exterior 4.1 998.0 3.31 3298.4 Exterior I 998.0 2.00 1996.0 Frame, Wood, Adjacent 11.0 261.0 1.80 469.8 Base Total: 1269.0 2465.8 As -Built Total: 1259.0 3768.2 I DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 19.0 4.00 76.2 Exterior Insulated 20.4 5.10 104.0 Exterior I 20.4 5.10 104.0 Adjacent Wood 19.0 5.90 112.3 I Base Total: 39.4 180.2 As -Built Total: 39.4 216.4 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1200.0 0.64 768.0 Under Attic 19.0 1310.0 0.87 X 1.00 1139.7 I Base Total: 1200.0 768.0 As -Built Total: 1310.0 1139.7 I FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 178.0(p) -1.9 -338.2 Slab -On -Grade Edge Insulation 0.0 178.0(p 2.50 445.0 Raised I 0.0 0.00 0.0 Base Total: -338.2 As -Built Total: 178.0 445.0 INFILTRATION Area X BWPM Points Area X WPM = Points , I 1200.0 -0.28 -336.0 1200.0 -0.28 -336.0 I EnergyGauge® DCA Form 60OA-2001 EnergyGaugeOlFlaRES'2001 FLRCSB v3.30 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS -BUILT Winter Base Points: =05. =inter -Built Points: 7056.7 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating (Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) 7056.7 1.000 (1.078 x 1.160 x 1.00) 0.502 1.000 4429.0 4005.E 0.6274 2513.1 7056.7 1.00 1.250 0.502 1.000 4429.0 I I, I EnergyGaugeTM DCA Form 60OA-2001 EnergyGauge®/FIaRES'2001 FLRCSB v3.30 I i FORM 60OA-2001 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details I ADDRESS: , , , PERMIT #: I BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 1 3 2564.00 7692.0 40.0 0.90 3 1.00 2507.02 1.00 7521.1 As -Built Total: 7521.1 CODE- COMPLIANCE STATUS BASE AS -BUILT Cooling + Points i. Heating + Points Hot Water = Total Points Points Cooling + Heating + Hot Water = Total Points Points Points Points 9318 2513 7692 19523 7264 .. 4429 7521 19214 PASS Energy IGaugeTM' DCA Form 60OA-2001 EnergyGauge®/FIaRES'2001 FLRCSB v3.30 FORM 60OA-2001 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfrn/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the pedmeter, penetrations and seams. Ceilings 606.1 ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1 ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. i R0:99 nwim PRFSCRIPTIVF MFOSIIRFS /must hp me+ nr exceeded by all residences-1 COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker electric or cutoff as must be provided. Extemal or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shover heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. I EnergyGauge"A DCA Form 60OA-2001 EnergyGaugeOlFlaRES'2001 FLRCSB v3.30