Loading...
HomeMy WebLinkAboutNOATHESIr RI., :►�.r" !i tD ALL F'RORCIS�_a i irl/O'?K ARE SI_lB,i� (� ,�Y CORRECTIOI+f REQI JIPt3�L: L ► ;.., : °.'pECTORS THAW 1L4,AY13Ei;i i�•.;ri!.k, `�`�'DERTO MIAMI-DADE COUNTY 111AMI'0 COMPLY 1.�.►'f t ll Aii_, `«��'1 f=�� �I E CODES. SCANNED ODUCT CONTROL SECTION `11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BY Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION St LUCI@ CoUnVY6) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE. (NOA) www.miamidade.eov/eeonomy Gulf Coast Supply.& Manufacturing LLC. 4020 SW 449`b St. CONCEALED FASTENERS OR ATTACHMENTS Horseshoe Beach, FL. 32648 FILE COPY �ECONTERRAECTORSOLRRLRC�-COOR THE I SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The dolcumentation submitted has been reviewed and accepted by Miami=Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). Thus NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product on material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use o such product or material within their jurisdiction: RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of; the applicable building code. This product is approved as described herein, and has been designed to co1J � , t]t lorida Building Code �S ANb ALL PROPOSED WORK including the High Velocity Hurricane Zone of the Florida Building Code. ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT DESCRIPTION: 26 ga. GulfRib Roof Panel over 15/32" Plywood dec"'AY BE NECESSARY IN ORDER TO ZOMPLY WITH ALL APPLICABLE CODES. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in' the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the in use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and sL11 be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. I . " NOA No.: 14-0520.01 MIAMbDADE COUNTY xpira 7rDate: 10/23/19 ST. LUCIE COUNTY BUILDING D SION Approval Date: 10/23/14 REVIEWED FOR C ANC REVIE E Page 1 of 6 DATE PLAN A D PERMI MUST BE KEPT ON B SITE 0R NO INSPE ION(S) WILL BE ADD ROOFING SYSTEM APPROVAL: Category: Roofing Sub -Category: Metal, Panels (Non -Structural) Material: Steel Deck Type: Wood Maximum Design Pressure-159.25 psf TRADE NAMES -OF;PRODUCTS `MANUFACTURED OR LABELED 8Y APPLICANT: Test Product Product Dimensions Specifications Description 26 ga. GulfRib Roof Length: various TAS 110 26ga. Steel, Flouropan Coated, Ribbed panel. Panel Height: 3/4" Width: 36" (coverage) Thickness: 26ga. (0.0185") MANUFACTURING LOCATION: 1. EVIDENCE SUBMITTED: Test Agency PRI Construction Materials Technologies. Farabaugh Engineering and Testing Force Engineering and Testing, Inc. Test Identifier VLS-004-02-01 VLS-005-02-01 T270-08A T126-07A 117-0062T-07A-C Test Name/Report ASTM G155 ASTM B 117 TAS 100 TAS 100 TAS 125 Date 02/22/13 02/22/13 07/18/13 07/18/13 07/26/13 .' NOA No.: 14-0520.01 Expiration Date: 10/23/19 Approval Date: 10/23/14 ' Page 2 of 6 ROVED ASSEMBLIES: m: 26Ga. GulfRib Roof Panel Type: Wood, Non -insulated Description: New Construction 19/32" or greater plywood or wood plank, or for re -roofing 15/32" or greater plywood. Range: 2": 12" or greater mum Uplift See Table A below !ck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d annular ring shank nails. spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum 15/32") The above attachment method must be in addition to existing attachment. iderlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4" side -lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12 gauge 1 ''/4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll or any approved underlayment having a current NOA. Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with the current published installation instructions and details in Gulf Coast Supply & Manufacturing LLC's Installation Manual. s and Install the "26Ga. GulfRib Roof Panel " and accessories in compliance with Gulf Coast Supply & Manufacturing LLC's current published installation instructions and details. Flashing, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standards RAS 133. 26Ga. GulfRib Roof Panels shall be fastened with a minimum of #9-15 x 1-1/2" woodgrip corrosion resistant screws. Fasteners shall of sufficient length to penetrate through the sheathing a minimum of 3/16. Fasteners shall be place in accordance with fastener detail herein as follows: TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corner Maximum Design Pressures 71.75 psf 159.25 psf Maximum Clip Spacing 24" o.c. 12" o.c. 1.1 Extrapolation shall not be allowed 77771 NOA No.: 14-0520.01 Expiration Date: 10/23/19 Approval Date: 10/23/14 Page 3 of 6 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). 3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in Roofing Application Standard RAS 133. 4. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 14-0520.01 MIAMIOADE COUNTY Expiration Date: 10/23/19 Approval Date: 10/23/14 Page 4 of 6 I PROFILE DRAWINGS DETAIL A FIELD CONDITION ling a min. ✓s. (optional) NOA No.: 14-0520.01 Expiration Date: 10/23/19 Approval Date: 10/23/14 Page 5 of 6 Overlap DETAIL A (CONTINUED) #9 Woodscrews long enough to penetrate through the sheathing a min., of 16" 14 x 8" stitch screws. (optional) typ. 12" o.c. for-159.25psf 2" From Panel End PERIMETER AND CORNER CONDITION END OF THIS ACCEPTANCE NOA No.: 14-0520.01 MIAMI•DADE COUNTY Expiration Date: 10/23/19 Approval Date: 10/23/14 Page 6 of 6