HomeMy WebLinkAboutDUCK SYSTEM SUMMARYI Oct. 23. 2018 8;11AM No.0388 P. 4 RECEIVEL- job. wlriglhtsoftr Duct System Sulmmary pate, Entire House OCT 2 3 W8 >3 QUICK CALCS, INC. ST. Lucie County, Permitting 317ST.LUCIELANE, FORT PIERCE. FL84946ftne:772-466.6799 Emall:QUICKCAWWOL.COM For: JOE JORDAN 755 ALTURA STREET, PORT ST. LUCIEI, FL 349 ' F)PY LL U Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O sCA/% Pressure losses 0 in H2O 0 in H2O "�� Available static pressure 0.50 in H2O 0.50 in H2O s QY t Supply/return available pressure 0,315/0.185 in H2O 0.31610.185 in H2O UC I Lowest friction rate 0.209 in/10011 0,209 in/100ft °Uhty Actual airflow 400 cf flTTm 1200 c Total efective length (TEL) 239 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfrrl) Clg (cfm) Design FR Diam Cln) H x W (in) Duct Mali Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH c 1293 15 61 0.212 40 Ox 0 Wx 38.6 110.0 st1 BATH c 969 15 46 0.215 6.0 Ox0 MFx 36.6 110.0 st'l BEDROOM 1 c 3371 64 160 0213 7,0 OX 0 MFx 37-7 110.0 st1 BEDROOM2 0 4213 85 200 0.209 6.0 Ox0 MFx 40.8 110-0 st1 WCNENCIMNG c 2895 20 '138 0.399 7.0 Ox0 VIFx 8.9 70.0 KITCHEWINING-A c 2895 20 138 0.274 7.0 Ox0 ViFx 25.1 90.0 st1 LIVING c 2447 43 116 0,393 7.0 Ox0 , V1Fx 10.3 70.0 LIVING -A c 2447 43 116 0.269 7.0 NO VIFx 27.3 90.0 st1 ROOM c 4730 94 225 0.248 9.0 Ox 0 VI Fx 37.0 90.0 st1 Supply Trunk Detail Table Name Trunk Type Htg (drn) Cig (drn) Design FR \/elOG (fpm) Diam (in) H x W (in) Duct Material Trunk st1 PeakA1/F 337 946 0,209 678 96.0 0 x 0 Un1Flx . LiJC`E�Otl O DI'II�� ST r.EVIE,WED FOR REVIEW 1) �Y DATE T Ni[i t ;E�t=ivor, SOB PLANS A rE OR NO �SPECTION `'yILL BE P,IADE. Boldrdalie values have been manually ovamuuen wrlghtsoft` 2010.00-221s;11:19 ��'� ..rc.reowa.wa.ytay J RlgrtShce8UAvsrae1201018.0.16RSU00701 Pe9e1 �(`�._QUICKTowwrvAWdgNwflWACUORDAN,JOE.np Cslc-MJ9 FroiYDoorfaces: SE Oct. 23. 2018 8:12AM No, 0388 P. 5 Grille . Kg Cig TEL Design Veloc Diam H x W Stud/Jolst Duct Name Size (in) (CMI) (C") (it) FR (fpm) (in) (in) Opening (in) Matl Trunk rb2 OXO 78 315 88.4 0209 713 9.0 0x 0 VIFx rt1 rb3 Ox 0 165 406 86.2 0.214 745 10.0 Ox 0 VI Fx rt1 rb1 OXO 157 478 37.8 0A88 448 14.0 0x 0 VIFx Return Trunk Detail Table Name Trunk Type Htg (cfin) Clg (cfm) Design FR Veloc (fpm) Diam On) HxW (In) Duct Material Trunk it1 PeakAVF 243 722 0,209 675 14.0 0 x 0 ViniFlx Bnlri4taM vafuee Aeve been manuaV ovenkk/en ti wrightwoft� 2098-Oa 2219:11 13 '+- IM�v�+•ny. �-70-. a RigII Sti"Urivers l 2018 ra 0,16 RSU0o1O1 Page 2 ^'f`�++� .IQUICOWY i&'WrigCtnILHVACUORDAN,JOE5.rLp Cslc=Md9 Frort Door Feoss:SE Oct, 23. 2018 8:12AM No, 0388 P. 6 'Job M Performed for: JOEJORDAN 755ALTURASTREET PORT ST, WCO, FL349U Sheet 1 QUICK CALLS, INC, 317 ST LUCIE LANE FORT PIERCE, FL34946 Phone: 772-466.6799 QUICKCAI.CS®AOL.COM Scale:1 : 92 Pagel RightSuihe@ Unfversal 2018 18,0,16 RSU08101 201 &Oct 2213:11:37 ..,IWrightoR HVAC1JORDAN, JOEaup