GENERATOR PAPERWORK
16/20/22 kW INCLUDES: • True PowerTM Electrical Technology �• Two Line LCD Multilingual Digital EvolutionTMController (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. • Electronic Governor �• System Status & Maintenance Interval LED Indicators i• Sound Attenuated Enclosure • Flexible Fuel Line Connector • Direct -To -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation j • 5 Year Limited Warranty • Capability to be installed within 18" (457 mm) of a building* TURES • GENERALwn� — — GUARDIAN° SERIES Residential Standby Generators SCANNED Air -Cooled Gas Engine sw Standby Power Rating Models G007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz Models G007043-0, G007042-0 (Aluminum - Bisque) - 22 kW 60 Hz �j O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O success in providing the most reliable generators possible. Generac's G-Force engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. C@us QU,E-T-'T7E7ST_— LISTED Note: CUL certification only applies to unbundled units and units packaged with pre -wired switches. Units packaged with the Snmrt Switch are UL certified in the *Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1 %. SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are J PROTOTYPE TESTED J NEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this J SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. w GENERAC ryat7.3 :�y4�,' *©* Mobile ' j PROMISE"k n G�YEP crO �'�Rflh�` •Bu/g M Me USA using EomesAamd&v /gnpart . GENERAC® 16/20/22 kW features and benefits Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinderwalls and plasma molyrings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. i • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur- ing up to a 2 year/200 hour oil change interval. i • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed i For your safety. Transfer Switch (if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • INEMA 311 Can be installed inside or outside for maximum flexibility. • ,Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution'" Controls • !Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • ISealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • 'Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • (Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- ically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • I Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building. Installation System • 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. i • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. • Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. i GENERAC° 16/20/22 kW specifications Generator IV G007035-0,G007036-0, G007038-0,0007039-0 G007042-0,G007043-0 Model G007037-0 (16 kW) (20 kW) (22 kW) Rate-dWaiirn-urF Continuous Power Capacity (LP) 16,000 Watts* _ 20,000 Watts* - 22,000 -� Rated Maximum Continuous Power Capacity (NG) _ _ 16,000 Watts* - 18,000 Watts* 19,500 r ---- LRatedVoltage 240 � 240 - _240 Rated Maximum Continuous Load Current- 240 Volts (LP/NG) 66.6/66.6 83.3/75 91.6/81.3 Total Harmonic Distortion — Less than 5% �70 Less than 5% Less than 5% Main Line Circuit Breaker Amp 100 Amp 100 Amp Number of Rotor Poles 2 2 Rated AC Frequency - 60 Hz - 60 Hz - 6OHz Power Factor 1.0 1.0 1.0 eight (Ib/kg) 406/186 448/203 466/211 lions (L x W x H) in/mm 48 x 25 x 29/1218 x 638 x 732 — _ output in dB(A) at 23 it (7 m) with generator operating at normal load** ^ 66 66 67- output in dB(A) at 23 8 (7 m) with generator in Quiet -Test' low -speed exercise mode** 58 58 58 � ;e duration 5 min _y 5 min 5 min Type of Engine GENERAC G-Force 1000 Series GENERAC G-Force 1000 Series GENERAC G-Force 1000 Series —; Number of Cylinders V 2 2 2 'Displacement - _ 999 cc i 999 cc _ - -999 cc Cylinder Block _ _ v _ - _- Aluminum w/ Cast Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve Overhead Valve Ignition Systea - - Solid-state w/ Magneto_- _Solid-state w/ Magneto Solid-state w/ Magneto ,Governor System Electronic Electronic Electronic PCompressionRatio 9.5:1-�- Operating rpm Fuel Consumption Natural Gas it3/hr (m3/hr) 1/2 Load Full Load Liquid Propane ft3/hr (gal/hr) [I/hr) 112 Load Full Load Note: Fuel pipe must be sized for full load. Require for LP gas. For Btu content, multiply ft3/hr x 2500 (LP', Approx.1.9 g1/1.8 L _Approx.1.9 gt/1.8 L _ Approx.1.9 gVl.8 L J 3,600 3,600 3,600 218 (6.17) 309 (8.75) 91.6 (2.52) [9.53] 204 (5.78) 301 (8.78) 86 (2.37) [8.99] 216 (6.12) 310 (8.78) 93.2 (2.56) [9.701 ssure to generator fuel inlet at all load ranges - 3.5-7° water column (7-13 mm mercury) for natural gas, 10-1 2'water column (19-22 mm mercury) x 1000 (NG). For Megajoule content, multiply m3/hr x 93.15 (IP) or m3/hr x 37.26 (NG) 2-Line Plain Text Multilingual LCD Display Simple user interface for ease of operation. Mode Butto_ns:Auto - - _ Manual _ Automatic Start on Utility failure.7 day exerciser. - Start with starter control, unit stays on. If utility fails, transfer to load takes place. Stops unit. Power is removed. Control and charger still operate. ady to Run/Maintenance Messages Igine Standard Run Hours Indication __— Programmable start delay between 2-1500 seconds Standard _ Standard (programmable by dealer only) Utility Voltage Loss/Return to Utility Adjustable (Brownout Setting) _ ' _ —� _ From 140-171 W190-216 V Future Set Capable Exerciser/Exercise Set Error Warning Standard _ I.RurVAlarm/Maintenance Logs — _ — — Engine Start Sequence — - _ 50 Events Each Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration). Starter Lock -out Starter cannot re-engage until 5 sec after engine has stopped_ Smart Battery Charger —_ _Standard _ _ Charger Faulf/Missing AC Warning Low Battery/Battery Problem Protection and Battery Condition Indication Standard — Standard _ I?Automatic Voltage Regulation with Over and Under Voltage Protection _ _ _— Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard ISatety Fused/Fuse Problem Protection Automatic Low Oil Pressure/High Oil Temperature Shutdown - - _ _ _- Standard -� Standard Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown -� ---` _ - Standard High Engine Temperature Shutdown Standard Internal FaullAncorrectWiring Protection _ _ - V- I Common External Fault Capability — I, Field Upgradable Firmware _- Standard Standard Standard j **Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator maybe higher depending on installation parameters. Rating definitions- Standby: Applicable tor supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514. IS03046 and DIN6271). * Maximum kilovolt amps and current are subject to and limited by such factors as fuel Btu/megajoule content, ambieattemperature, altitude, engine power and condition, etc. Marimum power decreasesabout3.5 percentforeach 1,000 feet (304.8 meters) above sea level; and also will decrease abcutl percentfor each 6 °C (10In above 16 °C (60IF) 16/20/22 kW Limited Circuits Switch Features • 16 circuits. • (Electrically operated, mechanically -held contacts for fast, positive connections • Rated for all classes of load,100% equipment rated, both inductive and 1 resistive. • 12 pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • 1 Rated for both copper and aluminum conductors. • 1 Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effec- tive install. Dimensions I 200 Amps 120/240,1 a Open Transition Service Rated � Height Width H1 H2 Wi W2 Depth in 27.24 30.0 11.4 13.5 7.09 mm 692.0 762.4 289.0 343.0 180.0 i Note: The 50 amp switch is flush mountable. H1 and W1 refer to mounting hole spacing. H2' and W2 are cover dimensions. H3 and W3 are the enclosure dimensions without cover Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 210-#14 2/0-#14 Service Rated Smart Switch Features • Includes Digital Power Management Technology standard (DPM). • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to four more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both inductive and resis- tive. • Up to four more large (120/240 VAC) loads can be managed when used in con- junction with 50 amp Power Management Modules (PMM**). • ' 2 pole, 250 VAC contactors. • , Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • I Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMANL 311 aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. Dimensions 200 Amps 120/240,10 Open Transition Service Rated Height Width Depth Ht H2 Wi W2 in 27.24 30.0 11.4 13.5 7.09 m'm 1 692.0 762.4 289.0 343.0 180.0 GENERAC® switch options Model G007036.0 (16kM No. of Poles 2 Current Rating (Amps) 100 Voltage Rating (VAC) 120/240.10 Utility Voltage Monitor (Fixed)* -Pick-up 60% -Dropout 65% Return to Utility* approx.15 sec Exerciser bi-weekly for 12 minutes*t Standard UL Listed Standard Total of Pre -wired Circuits 16 No. 15A120V 5 No. 20 A 120 V 5 No. 20 A 240 V 1 No. 30 A 240 V - No. 40 A 240 V 1 1 No. 50 A 240 V Tandem Breaker Capabilities 8 spaces Circuit Breaker Protected Available RMS Symmetrical 10,000 Fault Current @ 250 Volts *Function of Evolution Controller Exercise can be set to weekly or monthly Model G007037-0 (16 k"/GO07039-0 (20 kW)l G007043.0 (22 kW) Current Rating (Amps) 200 Voltage Rating (VAC) 120/240,10 Utility Voltage Monitor (Fixed)* -Pick-up -Dropout 80% 65% Return to Utility* approx.13 sec Exerciser weekly for 12 minutes* Standard UL Listed Standard Enclosure Type NEMA/UL 313 Circuit Breaker Protected 22,000 Lug Range 250 MCM - #6 *Function of Evolution Controller DEPTH i , GENERAC 16/120/22 kW available accessories Model # Product Description Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac- G006463-4 Mobile Link'" cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or text message when a change in the generator's status occurs. Available in the U.S. only. Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet G005819-0 26R Wet Cell Battery cell battery for use with all air-cooled standby product (excluding PowerPact®). The pad warmer rests underthe battery: Recommended for use if the temperature regularly falls below 0°F. G007101-0 Battery Pad Warmer (Not necessary for use with AGM -style batteries). Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below 1367102-0 Oil Warmer 0°F. The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers G007103-0 Breather Warmer only in climates where heavy icing occurs. Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load G005621-0 Contact Kit you may not need. Not compatible with 50 amp pre -wired switches. Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a G007021-0 - Bisque (Standard on 22 kW) sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from G005703-0 - Bisque Paint Kit future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G0 6485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. GO 6873-0 Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its (50 Amps) power management capabilities. It provides additional power management flexibility not found in any other u power management system. dimensions & PCs Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. Model UPC G007035-0 696471070354 G007036-0 696471070361 G007037-0 696471070378 G007038-0 696471070385 G007039-0 696471070392 G007042-0 696471070422 G007043-0 696471070439 rAti Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2016 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No.10000000194-C 08/18/16 _GENERATOR UN' 1 r BY7 SEPARATE SUBMITTAL (SEE CONCRETE PAD SCHEDULE FOR MINIMUM ::�-VIFEIGHT'REQU REQ)� ENGNEEERIING HURRICANE CONC (GENERAC A (ON-GRADI Q) w x z J PAD THICKNESS FRONT VIEW PAD LENGTH 1 ANCHOR FG3154-4G LOCATION ! - 9.859" l I N I { ; 1 { l ,-�17 , ram' \�`-----J (L — E"'�AG�NEERIN G a Ln 6 "^ TYPICAL ANCHORAGE: cp c m m 0 Y WIND LOAD Q RESULTANT 0 � z x i I 0I M Z a v c 95� SIDE VIEW PAD o PAD WIDTH THICKNESS (4) 3/8" DIA. AMIFAST CONCRETE INSERTS (PART# 165003 & TEST REPORT 95329 BY ELEMENT MATERIALS TECHNOLOGY) W/ 3/8" DIA. BOLT ASTM A307, 3" MIN. EDGE DISTANCE, 1-3/8" EMBED. INTO CONCRETE (BASE PAN MIN. THICKNESS = 0.69" AND MIN. BEARING STRENGTH = 6 KSI) I ITEM I GENERATOR I Ej rG]ii°N��!'ERI 1 8KW 2 1OKW 3 14KW 4 16KW ^, 5 16KW 6 17KW 7 17KW 8 2OKW 9 20KW 10 22KW 1- CONCRETE PADS WE] 2� FULL THICKNESS OF 3- ALL OTHER UNITS NC 4- CONTRACTOR SHALL EMBED. AS PER CURREP FROM ANY CONCRETE F, ',ETE PAD FOR GENERATORS D HONEYWELL UNITS) APPLICATIONS ONLY) __1<1(141, RAL NOTES ALLOWABLE DESIGN PE*0 LiSa9NA O,P,E I = i PRESSURE: SEE TABLE REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER �. ii8 021 � � i;Z� SEPARATE CERTIFICATION ON A JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. SITE SPECIFIC - = LOAD REQUIREMENTS AS DETERMINED IN ACCORDANCE �'OD rc�•E nmxstu rn GO N 1 TISIO, P.E _ WITH THE APPLICABLE BUILDING CODE SHALL BE LESS EL'.62 8 �� THAN OR EQUAL TO THE POSITIVE OR NEGATIVE DESIGN VALID 1 M T O I PRESSURE "ASO" CAPACITY VALUES LISTED HEREIN FOR E NOTICE: xKTNIs sHEET noes: . ANY ASSEMBLY AS SHOWN. NOT -CONTAIN AN ORIGINAL - SIGNATURE & ENGINEER SEAL: -• ' NTHIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE SIXTH EDITION (2017). \ \ i 2. �POSLCIVE�AND NEGATIVE DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE fiDETERMINkD. BY OTHERS ON A JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. -3./ LNAXIMUNI DIMENSIONS AND WEIGHT OF GENERATORS UNIT SHALL CONFORM TO SPECIFICATIONS --]I/STATED HEREIN. 4. THE AREA UNDER CONCRETE SLAB ON GROUND SHALL HAVE ALL VEGETATION, STUMPS, ROOTS, I1QTHERS.MHESECONCRETE PADS HAVE BEEN DESIGNED FOR A MINIMUM SOILL COEFFICIENT RIBY O VERIFIED )XFRIGII0Nt=.0.25 AND MINIMUM BEARING CAPACITY OF 2,000 PSF'AND MINIMUM SUBGRADE j t�„t MOAULo= 100 PCI. SHOULD OTHER CONDITIONS OR MATERIALS BE ENCOUNTERED, THE ENGINEER OF RECORD SHALL BE NOTIFIED PRIOR TO PROCEEDING WITH THE WORK. \ \ 5. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. ALL \ I MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER y RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. ` 6. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, eL al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FRQM'-MATERIAL r FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES-BEYOND`THAT WHICH ISSCALLED FOR APO BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OFTHIS PLAN: 55:-. J ISOMETRIC VIEW 7. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE.,THE FULCRESPONSIBILIFY`OFjIHINS EMff TALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY ROVED OR-ALTERED,WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSIXl]UATjON;OOF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLli MR ANY WATERPROOFING OR.LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE-T.HE'FULL.RESP.ONSIBILIOF THE INSTALLING CONTRACTOR. - `J r 8. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTJENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS�DESIGWWHICH $HALL BE COORDINATED BY THE PERMITTING CONTRACTOR. i� ��'1 L� �� lei1 'y �JJ 9. THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN TO.AN,Y SPECIFjC,PROJECT=SITE:, 1„ INFORMATION CONTAINED HEREIN IS BASED ON CONTRACiOR;SUPPLIElaDAT-ALAND MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT BE HEIR RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. DIMENSIONS ARE SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. WORK SHALL BE FIELD VERIFIED BY OTHERS PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION -----PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. ALTERATIONS OR ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND ---„----\1NVA4E ATE UUR GERTIFILATIUN. -lU. AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE \EXCEPT - �'.CO:,I CJtE'[E PAD SCHEDULE -(IN)` UNIT DIMENSIONS MINIM U WEIGHT CONCRETE PAD PAD DIMENSIONS (IN) PAD WEIGHT WIND LOADS T ALLOWABLE ALLOWABLE WIDTH ; LENGTH =HEIGHT IIMODjEL WIDTH LENGTH THICKNESS (LBS) PRESSURE RESULTANT 25.00 481''00', 29r00i360';U` jFG3154--4G 30.56 53.56 4.00 240 30.72 296.93 25.00 48.00 29.00 407 FG3154-4G 30.56 53.56 4.00 240 33.13 320.25 25.00 481.00 29.00 435 FG3154-413 30.56 53.56 4.00 240 34.57 334.21 25.00 48:00 29.00 448 FG3154-4G 30.56 53.56 4.00 240� 35.26 340.85 25.00 1 48100 29.00 1 513 FG3154-4G 30.56 53.56 4A0-- 240- 38.53 _ 7r372.44 25.00 48100 29.00 471 FG3154-4G 30.56 53.56 4.00240- 3( AO f ,' 351.88 I t.�_3 25.00 48100 29.00 431 FG3154-4G 30.56 53.56 4.00 r _� 2407 - • 34�37 332.20 25.00 48100 29.00 451 FG3154-4G 30.56 53.56 4.00 `440 35?39 /, , \342.12 25.00 48100 29.00 516 FG3154-4G 30.56 53.56 4.00 _--_240 1 38.70 Z 374.09 25.00 1 48,00 1 29.00 1 526 FG3154-4G 30.56 53.56 4.00 240 39.20 378.93 9`�1L-a9I��1�'�= j- ;I�'��� PKUV1UtU GY MANUI•AL.I UKtK, VtKll•1tU CY U I MtKS. -p j. T--) 7. f � • 1 C. S SHALL BE CONSTRUCTED WITH SOLID PRECAST CONCRETE, MINIMUM COMPRESSIVE STRENGTH; F[--,4;000•PSI=ATI28-DAYYSZ.�j HOWN SHALL BE DESIGNED ON A CASE BY CASE BASIS. LARGER CONCRETE PADS MAY BE DESIGNED`PER'DIFFEkEN LOAD COMBINATIONS. )VIDE 5/8" DIA. (6 675" O.D.) GALV. TUBE ASTM A53B SCH 40 MIN. OR 1/2" DIA. SOLID COPPER BAR SPIKE, 4' MIN. EMBED. (ALSO SEE MIN. -ECTRICAL CODE, BY OTHERS) INTO GROUND THROUGH CONCRETE PAD FOR SLIDING RESISTANCE PURPOSE, 12 DIAMETERS EDGE DISTANCE (NOT SHOWN) . fHERE•IS A DIGITAL . WATURE ON SHEET -!,'THIS ?ET IS PART OF A DIGITALLY ;NED FILE, SHALL REMAIN IN iTTAL FORMAT, & PRINTED PIES OF THIS DOCUMENT E NOT CONSIDERED SIGNET D SEALED. IF THERE IS NO i1TAL SIGNATURE ON SHEET 1 THIS SHEET DOES NOT MAIN AN ENGINEER'S IGINAL SIGNATURE & SEAL, Z'A N o 0 � wM,,,UF J $WOU W�W r~i OOwy&.N W 111 ITN In ZW ww U _Z IL F > Q W w W �wL7 0 zZ Will _4 i-aw w U W M2- 3OL��Z UJ axw Lu O n 1 Ila 0 0 0 o F f= Y m m m m� U F f- F u. Tu SW ugl ,11 -• ul aeiooufi . k66' U Z G gg Q 3 1 w In o o Y uJ U $$$$� Z -w m !2 `w COPYRIGHT ENGINEERING EXPRE55� 14-1669A SCALE: NITS UNLESS NOTED