Loading...
HomeMy WebLinkAboutGENERATOR PAPERWORKPower Generation RECEIVED ° OCT 19 2018 �T, L!•Igl@ C-91Jnty, Permitting RA series Transfer Switches The RA Automatic Transfer Switch is integrated with the RS series genset. These products are Listed to UL 1008, the Standard for Transfer Switch Safety. The switch and generator set combination is specifically designed for a simplified, quicker installation. These UL 1008 switches are suitable for standby power systems in residential and light commercial applications. These RA products adhere to National Electrical Code (NEC) and National Fire Protection Association (NFPA) requirements. The RA transfer switch monitors utility power 24 hours a day and 7 days a week. When utility power becomes unsatisfactory or fails; the generator set is signaled to start, then automatically transfers the load. When stable utility voltage returns, the transfer switch will automatically switch electrical load from the generator to the utility. No action is required by the home owner. The RA switch is also available in Service Entrance models. A service entrance version is also UL 1008 listed and makes use of a UL 489 listed circuit breaker. SCAN ail St Lucie Features Mechanically interlocked contactor ■ Long -life, high pressure, silver alloy contact resists burning and pitting ■ A powerful and economical solenoid drives the mechanism UL 489 Listed circuit breaker Solid bus bar connection ■ Between circuit breaker and transfer switch Neutral and ground bar ■ Fully rated ■ Bonding jumper on neutral and ground ■ Silver plated copper ground and neutral bus Ease of connection ■ Solderless screw type terminals for external power connections ST.LUCIE COUNTY PLAN REVIEW BLDG: DATE: ELE ' PLUMB: DATE: MECH: DATE: RA12 Transfer switch mechanism I Specifications ■ A powerful and economical solenoid powers RA Transfer Switches. ■ Independent break -before -make action is common for 2-pole. ■ Mechanical interlock prevents simultaneous closing of normal and emergency contacts. ■ Electrical interlocks prevent simultaneous closing signals to normal and emergency contacts and interconnection of.normal and emergency sources through the control wiring. ■ Long -life, high pressure, silver alloy contacts resist burning and pitting. Contacts are mechanically held in both normal and emergency positions for reliable, quiet operation. Voltage rating Transfer switches up to 240 VAC, 50 Hz or 60 Hz. Amperage rating Transfer switches rated for 100, 200 and 400 A continuous amperes. Arc interruption Multiple leaf arc chutes cool and quench the arcs. Barriers prevent inter tease flashover. Neutral bar A full current -rated neutral bar is standard on enclosed 2-pole transfer switches. Auxiliary contacts Two contacts rated at 5A continuous at 100 VAC or 2.5A continuous at 200 VAC (one for each source) are provided for customer use. Wired to terminal block for easy access. Storage temperature -25° C -1 T to 55° C 131 ° Humidity Up to 90% @ 20°C Altitude Up to 2,000 m 6,561 ftwithout deratin Total transfer time (source -to -source) Will not exceed 100 msecs with normal.volta e applied to the actuator. Manual operation handles Transfer switches are equipped with a removable operating handle which allows operation during servicing in order to facilitate troubleshooting with sources of power disconnected NAS-5810a-EN-S (10/15) RA13 UL 1008 withstand and closing ratings Transfer switch ampere Coordinated molded case breakers 100A 22,000 200A 22,000 100A SE 10,000 200A SE 10,000 400A 35,000 400A SE 35,000 Enclosures Wire bend space complies with 2013 NEC. Dimensions - transfer switch in UL type 31% enclosure Model and Height Width Depth Weight Amp rating in Mm in mm In mm lb kg Outline drawing 100 A 24.0 619 17.0 433 7.4 187 33 15 A04411213 200 A 27.1 688 18.2 463 7.4 187 46 21 A044R213 100A SE 23.3 591 19.8 503 7.2 182 58 26 A044R213 200A SE 23.3 591 19.8 503 7.2 182 58 26 A044R213 400 A 36.9 937 24.9 633 11.1 282 1 64.5 29.3 A049Z141 400A SE 47.9 1217 1 23.4 1 594 1 11.3 287 1 95.6 43.4 A049Z141 Transfer switch lug capacities Model and Amp rating Size 1 OOA #14 AWG to 2/0 CU/AL 200A #6 AWG to 300 MCM MAL 400A 3/0 to 600 MCM and #4 to 250 MCM Service entrance transfer switch lug capacities Model and Amp rating Size utility Load, neutral and generator Ground 1 OOA SE #4 AWG to 300 MCM MAL #14 AWG - 2/0 MAL #14-AWG - 1/0 MAL 200A SE #4 AWG to 300 MCM MAL #6 AWG - 300 MCM MAL (transfer switch and neutral only) #14 AWG - 2/0 MAL(generator) #14 AWG -1/0 MAL 400A SE 1 #2 to 250 MCM 3/0 to 600 MCM #6 to 3/0 Submittal details Description Part # Rating Voltage Enclosure RA112N3 A045P692 100 A 120/240 V 1 phase 313 RA212N3 A045P694 200 A 120/240 V 1 phase 3R RA112S3 A045P696 100 A SE 120/240 V 1 phase 3R RA212S3 A045P697 200 A SE 120/240 V 1 phase 3R RA412N3 A050W633 400 A 120/240 V 1 phase 3R (Aluminum) RA412S3 A050W853 400 A SE 120/240 V 1 phase 3R (Aluminum) Certifications U�All switches are UL 1008 Listed with UL Type ® Rated cabinets and UL Listed CU-AL terminals. %;� All switches comply with NEMA ICS 10. noAll switches comply with NFPA 70. NFPX NAS-5810a-EN-S (10/15) RA14 Power aw MrW Warlaq for YnWO ' Generation www.cumminspower.com North America 1400 73rd Avenue N.E. Minneapolis, MN 56432 USA 'Phone 763 574 5000 Fax 763 574 5298 Asia Pacific 10 Tbh Guan Road #07-01 TT International Tradepark Singapore 608838 Phone 65 6417 2388 Fax 65 6417 2399 Brazil Rua Jati, 310 Guarulhos —Sao Paulo CEP — 07180-140 Phone 55 11 2186 4195 Fax 55 11 2186 4729 Europe, CIS, Middle East 8, Africa Manston Park Columbus Ave. Manston Ramsgate Kent CT 12 513F United Kingdom Phone 441843 255000 Fax 44 1843 255902 Specifications are subject to change without notice ©2015 Cummins Power Generation. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand, InPower and "Our energy working for you." are trademarks of Cummins Power Generation. NAS-5810a-EN-S (10/15) Specification sheet RECEIVED OCT 19 2018 ST. Lucie County, f'ermitatf ST.LUCIE-COUNTY r, Quiet Co n n ect� PLAN REVIEW Series BLDG: DATE: 11 RS36 ELE . Power Generation DATES /) /i "V I`�..:__ • , ), .; PLUMB:_ SCANNED DATE: BY MECH: St Lucie County Y Features and benefits Robust product design and testing - The Advanced Enclosure Design - The aesthetically generator is designed to operate under extreme appealing enclosure incorporates special designs environmental conditions including cold weather that deliver the quietest generator of its kind. starts at as low as -40 OF. The generator is tested Aluminum material plus durable powder coat and certified per the latest EPA, UL and IBC paint provides the best anti -corrosion Seismic standards and is capable of meeting performance. The generator set enclosure has NFPA110 requirements when equipped with the been evaluated to withstand 180 MPH wind loads necessary accessories and properly installed. in accordance with ASCE7-10. The intelligent design has removable panels and service doors Flexible Exercise mode - The innovative, flexible to provide easy access for service and exercise mode enables the generator to exercise maintenance. at a time, frequency and duration that suits the customer's preference - as little as 2 minutes every 6 months - reducing unnecessary fuel consumption, emissions and noise. Self diagnostics and easy service - The generator is equipped with Cummins PowerCommand electronic control to provide industry -leading self diagnostic capabilities. In addition, critical components of the generator are designed to ensure service and preventive maintenance can be completed in a short period of time. Weight, size and sound level Weight: 1294 Ibs (587 kg) Size: Length 94 in (2388 mm), width 34 in (864 mm), height 45.5 in (1156 mm) Sound: 63 dB(A) at 23 ft (7 m) with sound level 2 enclosure Series Model Phase Voltage M Frequency (Hz) Rated amps' (NG/LPV fuel) Circuit breaker (Amps) RS36 C36 N6 1 120/240 60 150.0/150.0 175 3 1201208 60 124.9/124.9 150 3 120/240 60 108.3/108.3 125 3 277/480 1 60 54.1/54.1 60 I Derating guidelines: Engine power available up to 1005m (3300 ft) at ambient temperatures up to 40 °C (104 T). Above these elevations derate at 4% per 305m (1000 ft) and 2% per 10 °C above 40 °C (104 T). Bw*IMfIIIJrwOfkkfarM1." power.cummins.com 02015 Cummins Inc. NAS-5777d-EN (4/15) �% a D t Kj d ¢ j a,� I Product features Engine • Natural gas/propane 1800 rpm engine • Engine air cleaner - normal duty • Electronic governor, isochronous • Engine starter, 12 VDC motor • Shutdown - low oil pressure • Extension - oil drain 1 • Engine oil Fuel System • Single fuel - natural gas or propane vapor, field selectable Alternator • 60 Hz, 1 phase, 4 lead, or 3 phase, 12 lead, 120 °C temperature'rise at 40 °C ambient • Exciter/voltage regulator - torque match Control • PowerCommand 1.1 • Display language - English • Control mounting, right facing Electrical • Single circuit breaker, UL certified, right -side mounted • Battery charging alternator, normal duty • Battery charger - 6 Amp, regulated Cooling • Generator set cooling capability - 50 °C • Shutdown - low coolant level • Engine coolant - 50/50 mixture • Extension - coolant drain Enclosure • Aluminum enclosure Sound Level 1 with muffler installed, sandstone color • Wind rating -180 MPH Code compliance • UL 2200 • EPA emissions, emergency, stationary, 40CFR60 • IBC Seismic • NFPA110 capable Generator set application • Coolant heater • Crank case vent heater • Large battery rack • Flexible fuel line • Literature (English) - operator's manual, installation quick guide and manual, service manual Warranty • Base warranty - 2 year standby • Extended warranties available Packaging • Shipping pallet, poly bag Oer �+orlu wurerine � you: ®2015 Cummins Inc. I NAS-5777d-EN (4/15) Generator set performance Governor regulation class: ISO 8528 Part 1 Class G2 Voltage regulation, no load to full load: ±1.0% Random voltage variation: ±1.0% Frequency regulation: Isochronous Random frequency variation: ± 0.75% @ 60 Hz Radio frequency emissions compliance: FCC code Title 47 part 15 Class B Engine Design: Turbo with after cooler Bore: 86.5 mm (3.4 in) Stroke: 100.0 mm (3.94 in) Displacement: 2.4 liters (143.5 in3) Cylinder block: Cast iron, in -line 4 cylinder Battery capacity: 550 amps at ambient temperature of 0 OF to 32 OF (-18 °C to 0 °C) Battery charging alternator: 50 amps Starting voltage: 12 volt, negative ground Lube oil filter type(s): Spin -on with relief valve Standard cooling system: 500 C (1220 F) ambient cooling system Rated speed: 1800 rpm Fuel supply pressure Minimum fuel supply pressure, kPa (in H20): 1.5 (6.0) Maximum fuel supply pressure, kPa (in H20): 3.5 (14.0) Control system The PowerCommand@ electronic control is standard equipment and provides total generator set system integration including automatic remote starting/stopping, precise frequency and voltage regulation, alarm and status message display, output metering, auto -shutdown at fault detection and NFPA 110 Level 1 compliance. Sound attenuated enclosure The aesthetically appealing enclosure incorporates special designs that deliver the quietest generator of its kind. Aluminum material plus durable powder coat paint provides the best anti -corrosion performance. The generator set enclosure has been evaluated to withstand 180 MPH wind loads in accordance with ASCE7-10. The intelligent design has removable panels and service doors to provide easy access for service and maintenance. power.cummins.com Average fuel consumption. Fuel consumption - natural gas Fuel consumption - LP vapor Load: 1/4 1/2 3/4 Full Conversion factor: 8.58 ft3 = 1 lb 0.535m3 = 1 kg 36.39 ft3 = 1 gal Easy service and installation Removable Service Door Customer Access Door 0w w=kiw ftT Vws 02015 Cummins Inc. I NAS-5777d-EN (4/15) Load: 1/4 1/2 3/4 Full Display Oil Check nii Fill Circuit Breaker Natural Gas/Liquid Propane Fuel Connection Air Cleaner Coolant Fill power.cummins.com Basic dimensions DISTANCE REOUIRED TO LIFT OFF SERVILE PAMS\,y RADIATOR TILL ACCESS-- / 510 010 -1 AIR INTAKE A3£AS ` A- ACCESS 0003 FOR ENTER OF GRAVITY OPERATOR PANEL AND CIRCUIT BREAKER RANDLE TOP VIEW 2384 1943 ATCHfS AAE SERVICE PANEL -A V-FUEL CONNECTION k-SERVICE PASEI� KEY LOC6AflLF 11,21 1194 _V - SERVICE PANEL SERVICE PANEL RIGHT SIDE VIEW (dY1 LEFT SIDE VIEW Note: This outline drawing is provided for general reference only and is not intended for use in design or installation. For more information, see Operators and Installation manuals or contact your distributor or dealer for assistance. Automatic transfer panel configurations MM �'•nlUOTF (m �� wtMgSlRqutlDN ,� ID t•Di RL DMTFMVr= IPA) TFn3 uI Typical service entrance ATS model installation (100/200A) Typical non -service entrance ATS model installation (100/200A) Dedicated emergency standby service system (100/200A) 0WOMM" vo1lri7g far ym. ©2015 Cummins Inc. I NAS-5777d-EN (4/15) power.cummins.com 100A RA Series Automatic Transfer Switch (ATS) Non -service entrance jam_ I ; _ _---- iGb .m CO) U0uo 200A RA Series Automatic Transfer Switch (ATS) Non -service entrance Fly.._._. 14­ I I i 't,l- i 100A and 200A RA Series Automatic Transfer Switch (ATS) Service entrance i I lien- t I 02015 Cummins Inc. ; NAS-5777d-EN (4/15) power.cummins.com Accessories • HM1211 IRS in -home display, including pre -configured 12" harness • HM1211 remote display, including pre -configured 12" harness HM1220 remote display • Auxiliary output relays (2) • Auxiliary configurable signal inputs (8) and relay outputs (8) • Annunciator -RS485. • Internet monitoring device - PowerCommand 500 Battery chargers -stand-alone, 12V • Enclosure Sound Level 1 to Sound Level 2 upgrade kit • Enclosure paint touch up kit Base barrier - elevated generator set • Alternator heater • Maintenance and service kit • Engine lift kit Transfer switch (sold separately) • Automatic Transfer Switches available in various amperages. • Service Entrance models are also available, which helps reduce the installation cost. • All models UL listed to UL 1008 standard. • Available for both Indoor and Outdoor applications. • Compatibility with Cummins generator set helps reduce the installation time for the complete application. Warranty policy The Cummins RS and RX liquid cooled generator set models come with a 2 year base warranty when used in EPA -Stationary Emergency application. The RA series Automatic Transfer Switches come with a 2 year base warranty. Extended warranty options are available. Please contact Cummins dealers/distributors for details. After sale support Largest distributor/dealer support network Cummins Power Generation generator sets are +' supported by the largest and best trained worldwide uL CH certified distributor/dealer network in the industry. The network of knowledgeable and highly trained dealers will help you select the right generator for your application and advise you on associated accessories for your WARNING: generator. The dealer network can also help answer any ,A WARNING: questions you may have regarding operation and Standby rating based on: Applicable Back feed to a utility system can cause maintenances requirements of the generators. This same for supplying emergency power for the electrocution and/or property damage. network offers a complete selection of commonly used duration of normal power interruption. Do not connect to any building No sustained overload capability Is electrical except through an approved generator set maintenance parts, manuals and available for this rating. (Equivalent to device or after building mein breaker Is fuel stop power In accordance with open. specification sheets. IS03046, AS2789, DIN6271 and BS6914.( nominally rated. Sea T030. Manuals: Operation and installation manuals ship with the generator set. To obtain additional copies or other manuals for this model, see your distributor/dealer. To easily locate the nearest certified distributor/dealer for Cummins generators in your area, or for more information, contact us at 1-800-344-0039 or visit r)ower.cummins.com. Contact your distributor/dealer for more information. North America 1400 73rd Avenue N.E. Minneapolis, MN 55432 USA Phone 763 574 5000 Fax 763 574 5298 Ow malm wlmn9 twrv=&�- 02015 Cummins Inc. All rights reserved. Cummins is a registered trademark of Cummins Inc. "Our energy working for you." is a trademark of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others. Specifications are subject to change without notice. NAS-5777d-EN (4/15) C Power Generation power.cummins.com