HomeMy WebLinkAboutVEHICULAR SWING GATE OPERATOR MANUAL0997 RECEIVED. nPPRATnn ni=ni nRFC a • OCT 19 2018 LT.cie County, Permitting SCANNED BY 'St Lucie County • THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS - TECHNICIAN ONLY. • This model is for use on vehicular, passage gates. ONLY and not intended for use on. ' pedestrian passage gates. • This model' is intended for use in Class l .and I( vehicular swing gate applications. • Visit LiftMaster.com to locate a professional installing dealer in your area. • This gate operator is compatible with MyQ® and Security+ 2.00 accessories. jj Access installation and technical support guides or register this product Take a photo of the camera ST.LUCIE COUNTY icon including`the points (0). PLAN REVIEW ,. _ Send it in by texting the LiftMastee photo to 71403.. BLDG• DATE:. .. ... //. .. RSWI2ULTECH—Q DATE C' U0 L us - : PLUMB:' DATE: LISTED MECH: i Lifl'Master , DATE:. . 0 Windsor Drive k, Brook, 1L 60523 SAFETY 2 Safety Symbol and Signal Word Review...................................................2 UsageClass...............................................................................................3 UL325 Entrapment Protection Requirements............................................3 Safety Installation Information.....................:.............................................4 Gate Construction Information...................................................................5 INTRODUCTION 6 Cartonj Inventory ........................................................................................ 6 Operator Specifications..............................................................................7 SitePreparation.........................................................................................8 CheckYour Gate........................................................................................8 INSTALLATION 9 Step 11 Determine Location for Concrete Pad and Operator .......................9 Step 21 Concrete Pad and Operator Attachment.......................................11 Step 3i Position the Gate Bracket.............................................................12 Step 4 Adjust the Operator Arm Length...................................................12 Step 5 Secure the Operator Arm.............................................................:13 Step 6 Install Entrapment Protection.......................................................14 Step 7 Earth Ground Rod.........................................................................16 Step8 Power Wiring................................................................................16 Step 9 Dual Gate Setup............................................................................18 Step 10 Install the Cover.........................................................................20 i ADJUSTMENT 21 Limit iand Force Adjustment.....................................................................21 ObstructionTest......................................................................................22 PROGRAMMING 23 Remote Controls (Not Provided).............................................................23 LiftMaster Internet Gateway (not provided).............................................24 EraseAll Codes........................................................................................24 EraseLimits.............................................................................................24 Constant Pressure Override (CPO)..........................................................24 GateiHold Open Feature...........................................................................24 To Remove and Erase Monitored Entrapment Protection Devices ........... 24 Safety Symbol and Signal Word Review OPERATION 25 Control Board Overview...........................................................................25 ManualDisconnect..................................................................................26 ResetSwitch............................................................................................26 OperatorAlarm.......................................................................................26 RemoteControl ................. :...................................................................... 26 ACCESSORY WIRING 27 External Control Devices..........................................................................27 Locks.......................................................................................................28 Miscellaneous Wiring...............................................................................28 MAINTENANCE 29 Important Safety Information...................................................................29 MaintenanceChart ...................................................................................29 Batteries.................................................................................................... 30 TROUBLESHOOTING 31 DiagnosticCodes.....................................................................................31 Diagnostic Codes Table...........................................................................32 Control Board LEDs.................................................................................34 Troubleshooting Chart .............................................................................35 APPENDIX 38 DualGate Settings...................:...............................................................38 Types of Installations...............................................................................38 Step jr Determine Location for Concrete Pad and Operator.....................39 Step 2 Concrete Pad and Operator Attachment.......................................39 Step 3 Shorten the Operator Arm............................................................40 Step 4 Position the Gate Bracket.............................................................40 Step 8 Solar Panel(s)...............................................................................41 Limit Setup with a Remote Control..........................................................45 WIRING DIAGRAM 46 REPAIR PARTS 47 ACCESSORIES 48 WARRANTY 50 When you see these Safety Symbols and Signal Words on the following pages, they will alert youlto the possibility of Serious Injury or Death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical orfrom electric shock. Reatl the warnings carefully. When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your gate and/or the gate operator if you do not comply with the cautionary statements that accompany it. Read them carefully. IMPORTANT NOTE: • 1 BEFORE attempting to install, operate or maintain the operator, you must read and fully l understand this manual and follow all safety instructions. • DO NOT attempt repair or service of your gate operator unless you are an Authorized Service Technician. i MECHANICAL ELECTRICAL WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information go to www.P65Wamings.ca.gov. 2 Usage Class Class I - Residential Vehicular Gate Operator A vehicular gate operator (or system) intended for use in garages or parking areas associated with a residence of one -to four single families. Class II - Commercial/General Access Vehicular Gate; A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi -family housing unit (five or more single family units), hotel, garages, retail store, or other buildings accessible by or servicing the general public. Class III - Industrial/Limited Access Vehicular Gate A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not.accessible by or intended to service the general public. Class IV - Restricted Access Vehicular Gate Operator A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel. I I UL325 Entrapment Protection Requirements i . minimum of two independent` monitored entrapment protection devices are required to be installed at each entrapment zone . Every installation is unique. It is the responsibility of the installer to install external monitored entrapment protection devices in each entrapment zone . This vehicular swing gate operator will operate only after installation of a minimum of two independent" monitored entrapment protection devices in either the open or close direction. If no entrapment zone exists in the other direction of gate travel, then the inherent (built into the operator) is all that is required in that direction. . Entrapment protection device types include inherent (built into the I perator), monitored external photoelectric sensors or monitored external edge sensors . This operator is provided with an inherent entrapment protection device built into the operator that serves as one of the two independent devices i Independent - the same type of device shall NOT be used for both entrapment protection devices. i piplliq- IV IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of INJURY or DEATH: .. READ AND FOLLOW ALL INSTRUCTIONS. . NEVER let children operate or play with gate controls. Keep the remote control away from children. . ALWAYS keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. . Test the gate operator monthly. The gate MUST reverse on contact with an object or reverse when an object activates the noncontact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of INJURY or DEATH. • Use the emergency release ONLY when the gate is not moving. . KEEP GATES PROPERLY MAINTAINED. Read the owner's manual. Have a qualified service person make repairs to gate hardware. • The entrance is for vehicles ONLY. Pedestrians MUST use separate entrance. . SAVE THESE INSTRUCTIONS. Safety Installation Information 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one cojponent. Each gate system is specifically designed for an individual application. 2. Gate operating system designers, installers and users must take into account the possible hazards associated with each individual application. Improperly designed, installed or maintained systems can create risks for the user as well as the bystander. Gate systems design and installation must reduce public exposure to potential hazards. 3. Agate operator can create high levels of force in its function as a component part of a gate system. Therefore, safety features must be incorporated into every design. Specific safety features include: Edges Sensors (contact) Photoelectric Sensors Vertical Posts Instructional and Precautionary Signage 4. Install the gate operator only when: a. The operator is appropriate for the construction and the usage class of the gate. b. All exposed pinch points are eliminated or guarded, and guarding is supplied for exposed rollers. 5. The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The pedestrian access opening shall be designed to promote pedestrian Osage. Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate. 6. The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and dosing to reduce the risk of entrapment. Swinging gates shall not open Into public access areas. 7. The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. 8. Permanently mounted access controls intended for users to activate, must be located at least 6 feet (1.8 m) away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a security feature to prevent unauthorized fuse. Exception: Emergency access controls only accessible by lauthorized personnel (e.g. fire, police) may be placed at any location in ithe line -of -sight of the gate. 4 9. The Stop and/or Reset (if provided separately) must be located in the line -of -sight of the gate. Activation of the reset control shall not cause the operator to start. 10. A minimum of two (2) WARNING SIGNS shall be installed in the area of the gate. Each placard is to be visible by persons located on the side of the gate on which the placard is installed. 11. For agate operator utilizing a non -contact sensor: a. Reference owner's manual regarding placement of non -contact sensor for each type of application. See Install Entrapment Protection section. b. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving. c. One or more non -contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier. 12. For agate operator utilizing a contact sensor such as an edge sensor: a. One or more contact sensors shall be located where the risk of entrapment or obstruction exists. b. A hard wired contact sensor shall be located and its wiring arranged so the communication between the sensor and the gate operator is not subject to mechanical damage. c. A wireless device such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless device shall function under the intended end -use conditions. d. One or more contact sensors shall be located on the inside and outside leading edge of a swing gate. Additionally, if the bottom edge of a swing gate is greater than 4 inches (10.1 cm) but less than 16 inches (406 mm) above the ground at any point in its arc of travel, one or more contact sensors shall be located on the bottom edge. I 1.2 1.3 I I 1.4 1 1.5 Construction Information ar gates should be installed in accordance with ASTM F2200: Standard Specification for'Automated Vehicular Gate Construction. For a copy, ASTM directly at 610-832-9585 or www.astm.org. General Requirements - 3. Vehicular Horizontal Swing.Gate Gates shall be constructed in accordance with the provisions 3.1 The following provisions shall apply to Class I, Class II and Class III given for the appropriate gate type listed, refer to ASTM F2200 vehicular horizontal swing gates: for additional gate types. Gates shall be designed, constructed and installed to not fall 3.1.1 Gates shall be designed, constructed and installed so as not to over more than 45 degrees from the vertical plane, when a - create an entrapment area between the gate and the supporting gate is detached from the supporting hardware. structure or other fixed object when the gate moves toward the fully . open position, subject to the provisions in 3.1.1.1 and 3.1.1.2 Gates shall have smooth bottom edges, with vertical bottom edged protrusions not exceeding 0.50 inches (12.7 mm) when other than the exceptions listed in ASTM F2200. The minimum height for barbed tape shall not be less than 8 feet (2.44 m) above grade and for barbed wire shall not be less than 6 feet (1.83 m) above grade. An existing gate latch, shall be disabled when a manually 3.1.1.2 operated gate is retrofitted with a powered gate operator. A gate latch shall not be installed on an automatically operated gate. Protrusions shall not be permitted on any gate, refer to ASTM F2200 for. Exceptions. 3.2 Gates shall be designed, constructed and installed such that their movement shall not be initiated.by gravity when an automatic operator is disconnected, in accordance with the following. Vehicular horizontal swing gate. Shall not result in continuous, unimpeded movement in either direction along the arc of its path of travel. For pedestrian access in the vicinity of an automated vehicular gate, a separate pedestrian gate shall be provided. The pedestrian gate shall be installed in a location such that a pedestrian shall not come in contact with a moving vehicular access gate. A pedestrian gate shall not be incorporated into an automated vehicular gate panel.' Specific Applications Any non -automated gate that is to be.automated shall be upgraded to conform to the provisions of this specification. This specification shall not apply to gates generally used for pedestrian access and to vehicular gates not to be automated. When the gate operator requires replacement, the existing gate shall be upgraded to conform to the provisions of this specification. When the gate of an automated gate system requires replacement, the new gate shall conform to the provisions of this specification. The width of an object (such as a wall, pillar or column) covered by a swing gate when in the. open position shall not exceed 4 inches (102 mm), measured from the center line of the pivot point of the. gate. Exception: For a gate not in compliance with this, provision, the defined area must be provided with entrapment protection per UL 325. Except for the zone specified in Section 3.1.1.1., the distance between a fixed, object such as a wall, pillar or column, and a swing gate when in the open position shall not be less than 16 inches (406'mm). Exception: For a gate not in compliance with this provision, the defined area must be provided with entrapment protection per UL 325. Class IV vehicular.horizontal swing gates shall be designed, constructed and installed in accordance with security related parameters specific to the application in question. I Carton Inventory NOT SHOWN: Documentation packet and hardware bag I I I I I I e Arm Assembly I 6 ---------------------------------------------- Li I I I I I I p I I � I I 0 I •------------------------ ----------------------� taster Monitored Retro-Reflective Photoelectric Sensor Model LMRRUL r tta Warning Signs (2) and Warranty Card uowgaww�e�. �, NrbY�WWMMW d���-� �4LA Key (2) E>f� Battery 12 Vdc 7AH Operator Specifications Usage Classification Class 1 & II Main AC Supply 120 Vac, .5 Amps (6.5 Amps including Accessory Outlets) System Operating Voltage 12 Vdc Battery Run / Battery Backup Accessory Power 12 Vdc, 500mA max. for ON + SW (switched) Solar Power Max 12 Vdc at 30 watts max. Maximum Gate Weight%Length i 400 lbs. (181.4 kg)/l6 ft. (4.9 m) 600 lbs. (272.2 kg)/12 ft. (3.7 m) 700 lbs. (317.5 kg)/10 ft. (3 m) 800 lbs. (362.9 kg)/8 ft. (2.4 m) 1000 lbs. (543.5 kg)/6 ft. (1.8 m) 4-Degree Travel Time* < 17 seconds Maximum Travel Range* 115 degrees Maximum Daily Cycle Rate 250 cycles/day Maximum Duty Cycle Continuous Operating Temperature Without Heater: -200C to 600C (-4°F to 140°F) With Optional Heater: -40°C to 60°C (-40°F to 1400F) Expansion Board Optional External Entrapment Protection Device Inputs (non -contact Main board - up to 2 close entrapment protection devices and 1 open entrapment and/or contact) protection device. i Expansion board - up to.3 entrapment protection devices configurable to either close or open and up to 4 edge sensors using wireless edge sensor kit model LMWEKITU . "Travel time and range are affected byA and 8 mounting dimensions, see INSTALLATION. 7 Site Preparation Check the national and local building codes BEFORE installation. Gate Gate must be constructed and installed according to ASTM F2200 standards (refer to page 4). Gate must fit specifications of operator (refer to specifications). MIAMI i i I o Inside Property , i Safety Entrapment protection devices are required to protect against any entrapment or safety conditions encountered in your gate application. Install a warning sign (two provided) on the inside and outside of the property, where easily visible. i I I Warning Signs i i i r 1 �> I77 ara VEntrapment Danger inside Property I Check your gate Gate MUST be level. Gate and gate post MUST be plumb. Gate MUST have a smooth bottom edge, no protrusions should exist. i I I i ► �IIII► Remove ANY/ALL wheels from the Gate MUST NOT hit or drag across Gate MUST swing freely and be bottom of gate. ground supported entirely by its hinges. 8 i . To AVOID damaging gas, power or other underground utility lines, ALWAYS wear protective gloves and eye protection when changing contact underground utility locating companies BEFORE digging more the battery or working around the battery compartment. than 18 inches (46 cm) deep. Step 1 Determine Location for Concrete Pad and Operator For compact installation refer to the Appendix for installation steps 1-4, page 39. DO NOT run the operator until instructed. The illistration below shows the recommended dimensions for a standard installation. If these dimensions are not applicable for your installation refer to the chart on the following page for alternate dimensions. Standard Installation Refer to the illustration to determine the measurements and location of the concrete pad. NOTE There should only be a maximum of 4' (f0.2 cm) from the center of the hinge to the edge of the post or column. If the distance is greater than 4' (10.2'!cm) entrapment protection for this area is required. Hinge center 4' (10.2 cm) maximum ntirci& Prnnartv 1 46' (116.8 Cm) Concrete Pad 9 fa Long Arm ` -� --=-- 35.5' — (90.2 cm) 11. 27.9 cml Short Arm ` 29.5' 02 -` (74.9 cm) 128' (71.1 cm) i r— 24' - ► (61 cm)-- f Chart Installation Refer to the illustration to determine the measurements and location of the concrete pad: I Gate Hinge Center NOTE: There should only be a Outside Amaximum of 4- (10.2 cm) ' from the center of the hinge Inside to the edge of the post or column. If the d/stance /s greater than 4' (10.2 cm), entrapment protectlon for Vs area /s required. Outside Inside If this dimension Is between 20' (50.8 cm) and 32' (81.3 cm), a compact Installation Is necessary. _t Refer to LlftMastercom for compact Installation Instructions. D MINUS 10" �. (25.4 cm) (25.4 cm) \. ice•,: �' '� �. DISTANCE Concrete Pad t \ Dimension (A) thru (E) are from the center of one pivot point to the center of another pivot paint. Caution: If the gate is longer than 18 feet (5.5 m), follow CHART A: A-2. Suggestion: The dimensions between the gate and the concrete pad is always 10 inches (25.4 cm) less than the dimension D. Example: D = 42" (106.7,cm), if the dimensions between the gate and the concrete pad is 32 (81.3 cm). Ch rt A Chart B A B C D E DISTANCE A B C D E DISTANCE 1 i 4 5 6 46' 35.5" , - ;29:5" 35" 11" 45" (116.8" (90.2 cm) (74.9 (90.2 cm) (27.9 (114.3 cm) cm) cm) cm) 1' 46.8" { 35.5" 315„ - 42" 11" 37" (118.8 (90.2 cm (85.1 (106.7 (27.9 (94 cm) j cm) cm) cm) cm) 46.8" ' 37" 31:5" 40" 11" 41" h (118.8 (94 cm) (80 cm) (101:6 (27.9 (104.1 cm) cm) cm) cm) 47.3" 37.3" 30 37, 11" 45" f (120 cm) (94.6 cm) (76.2 (94 cm) (27.9 (114.3 cm) cm) cm) I 477 35" `29.5" 32' 11,, 45" (119.4 (90.2 cm) (74.9 (81..3 cm) (27.9 (114.3 cm) cm) �42.5" 33" 26.5" 28.5" 11"' 41" , (108 cm) (116.8 (67.3 (72.4 cm) .. (27.9 (104.1 i cm) cm) cm) cm) - 1 2 3 4 5 6 10 34.5" 34.8" 29.5" 3 5" 14" 43° (87.6 cm) (88.3 cm) (74.9 cm) (90.2 cm) (35.6 cm) (109.2 cm) 44" 36.5" 32.5" 42" 14" 32' (111.8 (92.7 (82.6 (106.7 (35.6 (81.3 cm) cm), cm) cm) cm) cm) 44" 37° 30.5". 40" 14" 40" ''(111.8 (94 cm) (77.5 (101.6 (35.6 (101.6 cm) cm) cm) cm) cm) '45" 37' 30.5' 37" 14" 43" (1cm)3 (94 cm) (77. cm)44:8" (94 cm) (cm) (109.2 cm) 35.8" 29.5" 32' 14" 44" (113.7 cm)' (90.8 cm) (74.9 ' cm) (8,1.3.cm) (35.6 cm) (111.8 cm) 41" 39" 27.5" 28.5" 14 41" (104.1 (99.1 (69.9 (72.4 cm), (35.6 (104.1 cm) cm)- cm) cm) cm) e Step 2 Concrete Pad and Operator Attachment CHECK the national and local building codes before installation. 4.5' 5.5' Conduit Location 11107E:1 When lifting the operator use the handle to avoid damaging the (11.4 cm) (14 cm) operator 4' 1. Install the conduit. -;.-.-: i electrical 2. Pour a concrete pad (reinforced concrete is recommended), The �_ (16.5 cm �--:. concrete pad should be 6 inches (15.2 cm) above the ground and -�-- _-�_== deeper than the frost line. Ensure the pad is tall enough to avoid _conduct xu 3, ' possible flooding. 1a. (2' (3.8cm) 3. Secure the operator to the concrete pad with appropriate fasteners. NOTE: An alternative to a concrete pad is to post mount the operator, see Accessories. I 24- (61 Cm) • t9 6' (15.2 cm) Above Groundi.' ` ff{•, ;. ' Below the frost Ilne, ! Check ali natlonal and local codes. 28' (71.1 cm) y 24 (61 cm) Mounting Footprint 13.6' (34.5 cm) ,I 12,2' 31 cm (6 3 cm) 1�m1' I 3 � 3 14.8' (37.6 cm) Cover Mounting Distance Step 3 Position the Gate Bracket MOTE.•i It may be necessary to attach horizontal reinforcement to the gate before attaching the gate bracket. 1. Position the operator arm onto the output shaft so that the pin slides into the slot. 2. Measure 46" (116.8 cm) along the gate length from the gate hinge center. 3. Measure 27.5" (69.9 cm) up from the concrete pad to the gate hinge position on the gate as shown. 4. Make sure the operator arm is level and tack weld the gate bracket in this position, Use the set screws on the arm to temporarily hold the arm in place while determining the correct measurements. U I Step 4 Adjust the Operator Arm Length MOTE: The length of the arm can be adjusted if necessary. If adjusting the length, ensure that both sections of the arm are adjusted proportionally. Use the set screws on the arm to temporarily hold the arm in place while determining the correct measurements. 1, Close the gate and measure the distance of the operator arm from the gate bracket to the output shaft center. This distance is E. 2. IOpen the gate 900 (do not allow arms to scissor when open). I Measure both sections of the arm (D and C). The arm lengths are !correct as long as C+D=E (arm should be perpendicular to the gate ! in the open position as shown). I 12 Gate Top view - open gate Open go- y Set Screws Top view - closed gate Output Shaft 2 Step 5 Secure the Operator Arm Once the operator arm measurements are verified: 1. Weld the gate bracket to the gate. 2. Weld the short arm section. 3. Weld the long arm section. 4.emove the set screws from the arm. NOTE: Completely weld around t e outer tubing and bracket. 5. t"djustthe nuts on the operator arm so the operator arm fits snug on the output shaft yet still allows enough room to swivel (the handle must be in a 900 position). 6. Tighten the handle by pushing it down. Test to make sure the operator arm does not slip on the output shaft. i i 13 To prevent SERIOUS INJURY or DEATH from a moving gate: . 'ALL gate operator systems REQUIRE two independent entrapment 'protection systems for each entrapment zone. • Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate. Step 6 Install Entrapment Protection Entrapment protection MUST be installed according to the following UL 325 requirements: • Swing gate operators require the installation of the first external monitored entrapment protection device to function. • Every installation is unique. It is the responsibility of the installer to ensure that ALL entrapment zones are protected with an external monitored entrapment protection device, protecting both the open and close gate cycles. • Lif master monitored external entrapment protection devices MUST be used with LiftMaster operators to meet UL325 requirements, see Accessories. . Test ALL entrapment protection devices after completing installation of the operator. For testing instructions; refer to the manual provided with your entrapment protection device. 7l1estrotlon Is for example only, • your slte,may'have additional entrapment zones which MUST be protected. Public Side Place the warning signs on both sides.of the gate In clear view ' m e .nnp rth gro Pedestrian gate located near Hin nuAnn ne1n .RA�be 91,—; .n. Is, available, and,the:path, Is, clearly designated. Photoelectric sensor (public side) , „ • Locate entrapment protection devices to protect in BOTH the open and close gate cycles. • Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts, walls, pillars, columns, or operator itself. Definitions ENTRAPMENT: The condition. when a person is caught or held in a position that increases the risk of injury. SWING GATE ENTRAPMENT ZONE: Locations between a moving gate or moving, exposed operator components and a counter opposing edge or surface where entrapment is possible up to 1.8 m (6 ft) above grade. Such locations occur if during any point in travel: a. The gap between the bottom of a moving gate and the ground is greater than 101.6 mm (4 in) and less than 406 mm (16 in); or b. The distance between the center line of the pivot and the end of the wall, pillar, or column to which it is mounted when in the open or closed position exceeds 101.6 mm (4 in). Any other gap between a moving gate and fixed counter opposing edges or surfaces or other fixed objects is less than 406 mm (16 in) (examples are walls, curbs, berms or other immovable objects). Illustrations provided by DASMA Gate Systems Safety Guide Mount,access control -devices at v -. I ast a (1 8 m) beyond the gate, r Photoelectricsensor , r, sensor ev .a /%ile Ng //%✓ 14 ire Side Take a photograph of th Installation site for your r for ctr1E - Wire Entrapment Protection Devices There iare three options for wiring the entrapment protection devices depending on the specific device and how the device will function. Refer to the specific entrapment protection device manual for more information. These entrapment protection device inputs are for monitored devices, which include pulsed photoelectric sensors, resistive edge sensors, and pulsed edge sensors. Only one monitored entrapment protection device may be wired to each input. Additional entrapment protection devices may be wired to the expansion board. Control Board CLOSES EYES/INTERRUPT (2 Terminals) The CLOSE EYES/INTERRUPT input is for photoelectric sensor entrapment protection for the close direction. When an obstruction is sensed during gate closing the gate will open to the full open position and resets the Timer -to -Close. This input will be disregarded during gate opening. CLOSE EDGE (2 Terminals) The CLOSE EDGE input is for edge sensor. entrapment protection for the close direction. When an obstruction is sensed during gate closing the gate will reverse to the full open position, disengaging the Timer -to -Close. This input will be disregarded during gate opening. OPEN EYES/EDGE (2 Terminals) The OPEN EYES/EDGE input is for photoelectric sensor or edgelsensor entrapment protection for the open direction. When an obstruction is sensed during gate opening the gate will reverse for 4 seconds then stop. This input will be disregarded during gate closing. I Expansion Board (not provided) EYE, ONLY and COM Open or Close Direction Photoelectric Sensors, the functionality is based. on the switch settings (located next to the terminals) Switch set to CLOSE: gate reverses fully when an obstruction is sensed Switch set to OPEN: gate reverses 4 seconds when an obstruction is sensed EYE/EDGE and COM Open or Close Direction Photoelectric Sensors or Edge Sensor, the functionality is based on the switch settings (located next to the terminals) Switch set to CLOSE: gate reverses fully when an obstruction is sensed Switch set to OPEN: gate reverses 4 seconds when an obstruction is sensed 15 Close Photoelectric Sensors WE CLOSE, UQ Close Edge EDGE+ OW! EYES/ -- EDGEo o Open Photoelectric Sensors OR Open Edge W u tQt O U EYE ONLY 1 EYFJEDG E 2CM EYE/EDGE l� s® Photoelectric Sensors Photoelectric Sensors OR Edge Sensor Step 7 Earth Ground Rod Use the proper earth ground rod for your local area. The ground wire must be a single, whole piece of wire. Never splice two wires for the ground wire. If you should cut the ground wire too short, break it, or destroy its integrity, replace it with a single wire length. 1. Install the earth ground rod within 3 feet (.9 m) of the operator. 2. Run wire from the earth ground rod to the operator. NOTE: If the operator is not grounded properly the range of the remote controls will be reduced and the operator will be more susceptible to lightning and surge damage. I Step 8 Power Wiring reduce the risk of SEVERE INJURY or DEATH: ANY maintenance to,the operator or in the area near the operator MUST NOT be performed until disconnecting the electrical power (AC or solar and battery) and locking -out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service. Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected in accordance with national and local electrical codes. NOTE: The operator should be on a separate fused line of adequate capacity. To operator „* c Check national and. local codes for proper depth M;, �.r{�,;, n • ALL electrical connections MUST be made by a qualified individual. • DO NOT install ANY wiring or attempt to run the operator without consulting the wiring diagram. • ALL power wiring should be on a dedicated circuit and well protected. The location of the power disconnect should be visible and clearly labeled. • ALL power and control wiring MUST be run in separate conduit. I Theloperator can be wired for either 120 Vac or a solar panel (not provided). Follow the directions according to your application. The battery is charged in the circuit by the integrated transformer. The operator requires one 7AH battery (provided) or one 33AH battery. The 33AH application requires the 33AH wire harness (Model K94-37236). For idual gate applications, power will have to be connected to each operator. Main power supply and control wiring MUST be run in separate conduits. All control wiring used to connect external devices to Class 2 circuits of the operator must be (OPTZ) Power -Limited Circuit Cables, Type CL2, CL2P, CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings. SOLAR APPLICATIONS: For solar applications refer to Solar Panels section in the Appendix. Follow the directions according to your application. (AVIG 18 If.11 I NO] EXTERNAL PLUG-IN TRANSFORMER (24 VAC) 150 feet (46 m) 16 250 feet (76 m) 14 1150 feet (351 m) 400 feet (122 m) 12 1850 feet (564 m) 600 feet (183 m) 10 2950 feet (899 m) 1,000 feet (305 m) NOTE: Use copper conductors ONLY. 16 i i Power wiring 1. Turn off the AC power from the main power source circuit breaker. 2. Run the AC power wires to the operator. 3. Unplug the transformer. 4. Remove the junction box cover. 5. Run the AC power wires through the knockout in the bottom of the electrical box. 6. Connect the green wire to the earth ground rod and AC ground using a wire nut. NOTE. The earth ground rod can be grounded to toe chassis. 7. Connect the white wire to NEUTRAL using a wire nut. 8. Connect the black wire to HOT using a wire nut. 9. Replace the junction box cover. Ensure the wires are not pinched. 10. Plug in the transformer. 11. Turn ON AC power to the operator. i 33AH battery To use a 33AH battery in place of the 7AH battery, follow the instructions below. The 33AH application requires the 33AH wire harness (Model K94-37236). 1. Unplug the transformer. 2. (Unplug the J15 plug labeled BATT on the control board by squeezing the plug and pulling it from the control board. This idisconnects the ac/dc power to the control board. Discard this J15 !plug and harness. 3. Connect one end of the red (+) wire from the new 33AH wire harness kit to the red wire from the new J15 plug as shown. Connect the other end of the red (+) wire to the positive (+) terminal on the battery as shown. 4. ! Connect one end of the black (-) wire from the new 33AH wire i harness kit to the black wire from the new J15 plug as shown. Connect the other end of the black (-) wire to the negative (-) terminal on the battery as shown. 5. Reconnect the new J15 plug to the control board. NOTE. You may see a small spark when plugging the J15 plug into the board. 6. ! Plug in the transformer. 17 Junction Box Cov J15 plug - new wire harness Model K94-37236 Red (+) 6 Red (+) wire Black(-) wire from new wire from new wire harness kit harness kit 33AH Battery i Step 9 Dual Gate Setup There pare two options for dual gate communication: wired or wireless. Follow the directions according to your application. Do not use wired and wireless communication simultaneously. Wired dual gate applications will have a longer battery standby time than wireless applications. Wireless setup To activate the wireless feature: 1. Choose an operator to be the network primary operator. All wireless accessories will need to be programmed to the primary operator. NOTE. We recommend that all accessories and board configurations are set on the primary operator. 2. P'ress and release the LEARN button on the primary operator. The green XMITTER LED will light. NOTE. The operator will time out of programming mode after 180 seconds. 3. P;ress and release the LEARN button again on the primary operator. The yellow NETWORK LED will light. 4. Press and release the OPEN test button to assign this operator as network primary. 5. Press and release the LEARN button on the second operator. The green XMITTER LED will light. 6. Press and release the LEARN button again on the second operator. The yellow NETWORK LED will light. 7. Press and release the CLOSE test button to assign this operator as network second. Both operators will beep and the yellow NETWORK LEDs will turn off indicating programming is successful. To deactivate the wireless feature: 1. Press and release the LEARN button on either operator. The green XMITTER LED will light. 2. Dress and release the LEARN button again on the same operator. The yellow NETWORK LED will light. 3. Press and hold the LEARN button for 5 seconds. The yellow NETWORK LED will blink (operator will beep) then turn off indicating successful deactivation. 4. Repeat the steps for the other operator. I i 18 Wire,�d setup Beforeldigging, contact local underground utility locating companies. Use PVC conduit to prevent damage to cables. 1. Disconnect ALL power to the operator and unplug the J15 plug from the control board. 2. Trench across driveway to bury the shielded twisted pair cable. 3. Connect the wires from the shielded twisted pair cable to the Com Link terminals on the primary gate operator control board. NOTE, We recommend that all accessories and board configurations are set on the primary operator. 4. Route the shielded twisted pair cable to the secondary gate operator's control board. 5. C,onnect the wires from the shielded twisted pair cable to the Com Link terminals on the secondary control board (Com Link A to Com Link A and Com Link B to Com Link B). Ground the shield of the cable to the chassis ground of one operator. 6. Connect ALL power to the operator and plug the J15 plug into the control board. Bipart delay/synchronized close The iLOCK/BIPART DELAY switch is used only with dual gate applications and serves two functions: • PIPART DELAY SWING GATEAPPLICATIONS: The BIPART DELAY is used in applications where a mag-lock, solenoid lock, or decorative overlay would require one gate to close before the other. The operator with the LOCK/BIPART DELAY switch ON will delay from the close limit ;when opening and be the first to close from the open limit. 'SLIDE GATE APPLICATIONS: Not applicable, set to OFF. . SYNCHRONIZED CLOSE The BIPART DELAY is also used in applications where one gate travels a longer distance than the other. To synchronize the closing of ithe gates, set the LOCK/BIPART DELAY switch to ON for both � operators. 19 r r 722AWG up to 200 feet (61 m) I 18AWG - 200-1000 feet (61-305 m) Wire must be rated at 30 Volt minimum ' BAN BIPART. W FAIL DELAY o W 818o 8 P® P-o. ! + i Step 10 Install the cover Beford installing the cover, follow the instructions in the Adjustment section to adjust the limits and force. The operator cover consists of two pieces: a rear cover and a front cover The front cover can easily be removed to access the electrical box. To accessIthe reset switch slide the access door.up. The front cover and accessldoor can be locked with the key. I 1. Remove the operator arm from the output shaft by releasing the handle. 2. Align the tabs on the rear cover with the slots on the chassis and place the cover over the operator. 3. Secure both sides of the rear cover to the chassis with two 5/16-18 lead in screws. 4. Reattach the operator arm to the output shaft (making sure the pin fits into the slot) and secure by pushing the handle down. 5. Place the operator arm cover over the operator arm and secure. 6. Align the front cover with the back cover, making sure the grooves like up. 7. Secure the front cover to the chassis with two 5/16-18 lead in screws. 8. Slecure the front cover to the rear cover using the 5/16-18 lead in screw. I I i I i To Lock the Access Door From'the factory the access door for the reset switch will not be locked. To lock the access door follow the steps below: 1. Locate the lock tab on the back of the front cover and remove the screw securing the tab to the cover. 2. Turn the tab 180 degrees, then secure with the screw. The access door can now be locked. The basic installation is complete. I 20 Access Door 5/16.16 lead In screw Limit and Force Adjustment To (reduce the risk of SEVERE INJURY or DEATH: • Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a moving gate. • Too much force on gate will interfere with proper operation of safety reversal system. NEVER increase force beyond minimum amount required to move gate. Introduction Your operator is designed with electronic controls to make travel limit and force adjustments easy. The adjustments allow you to program where the gate will stop in the open and close position. The electronic controls sense the amount of force required to open and close the gate. The farce is adjusted automatically when you program the limits but should be fine tuned using the REVERSAL FORCE dial on the control board (refer to Fine Tune the Force section) to compensate for environmental changes. The limit setup LEDs (located next to the SET OPEN and SET CLOSE buttons) indicate the status of the limits, refer to the table to the right. The limits can be set using the control board (below) or a remote control (refer to Limit Setup with a Remote Control in the Appendix). Setting the limits with a remote control requires a 3-button remote control programmed to OPEN, CLOSE, and STOP. NOTE., The TEST buttons on the control board will not work until the limits have been set and the required entrapment protection devices are installed. Initial Limits and Force Adjustment For deal gate applications the limits will have to be set for each operator. The gate MUST be attached to the operator before setting the limits and force. 1. Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode. 2. Press and hold one of the MOVE GATE buttons to move the gate to the open or close limit. 3. P�ess and release the SET CLOSE or SET OPEN button depending on which limit is being set. 4. Press and hold one of the MOVE GATE button to move the gate to the other limit. 5. Press and release the SET CLOSE or SET OPEN button depending on which limit is being set. 6. Cycle the gate open and close. This automatically sets the force. When limits are set properly.the operator will automatically exit limit setting mode. 21 • NEVER use force adjustments to compensate for a binding or sticking gate. • If one control (force or travel limits) is adjusted, the other control may also need adjustment. • After ANY adjustments are made, the safety reversal system MUST be tested. Gate MUST reverse on contact with an object. LIMIT SETUP r SET OPEN LED SET CLOSE LED OPERATOR MODE EXPLANATION OFF OFF NORMAL MODE Limits are set BLINKING BLINKING LIMIT SETTING MODE Limits are not set BLINKING ON LIMIT SETTING MODE Open limit is not set ON BLINKING LIMIT SETTING MODE Close limit is not set ON ON LIMIT SETTING MODE Limits are set IT • I o � de 6 A q * Fine Tune the Force Once the initial limits have been set, the REVERSAL FORCE DIAL on the control board is used for fine tuning the force where wind or environmental changes may affect the gate travel. The REVERSAL FORCE DIAL is set to minimum at the factory. Based on the length and weight of the gate it may be necessary to make additional force adjustments. The force setting should be high enough that the gate will not reverse by itself nor cause nuisance interruptions, but low enough to prevent serious injury to a person. The force setting is the same for both the open and close gate directions. 1. Open and close the gate with the TEST BUTTONS. 2. If the gate stops or reverses before reaching the fully open or closed position, increase the force by turning the force control slightly cl'ackwise. 3. Perform the "Obstruction Test" after every limit and force setting adjustment (see below). Adjust the Limits After both. limits are set and the operator is ready to run, one limit can be adjusted independently from the other by following steps 1-3 of the Initial Limit and Force Adjustment section. Obstruction Test The operator is equipped with an inherent (built in to the operator) obstruction sensing device. If the gate encounters an obstruction during motionl, the operator will reverse direction of the gate and then stop. The following procedure will test ONLY the inherent (built in to the operator) obstruction sensing device: 1. Open and close the gate with the TEST BUTTONS, ensuring that the gate is stopping at the proper open and close limit positions. 2. Place an object between the open gate and a rigid structure. Make sure that any external entrapment protection devices will NOT be activated by the object. 3. Run the gate in the close direction. The gate should stop and reverse upon contact with the object. If the gate does not reverse off the object, reduce the force setting by turning the force control slightly counter -clockwise. The gate should have enough force to reach both they open and close limits, but MUST reverse after contact with an object. 4. Repeat the test for the open direction. Test the operator after any adjustments are made. 22 so NS 0 U m z 0 o a) m REVERSAL FORCE Remote Controls (Not Provided) A total of 50 Security+ 2.00 remote controls or KPW250 keypads and 2 LEARN TEST keyless entries (1 PIN for each keyless entry) can be programmed to the BUTTONS operator. When programming a third keyless entry to the operator, the o EM TTER EA first keyless entry will be erased to allow the third keyless entry to be programmed. When the operator's memory is full it will exit the NE OR programming mode and the remote control will not be programmed. The AL f memory will need to be erased before programming any additional _ remote controls. NOTE. If installing an 86LM to extend the range of the remote controls DO NOT straighten the antenna. There !are 3 different options for programming the remote control depending on how you would like the remote control to function. Choose a programming option: OPTION DESCRIPTION •i Single button as OPEN Program a single button on the remote 1. Press and release the LEARN button (operator will beep and green only control for open only. The Timer -to -Close WITTER LED will light). NOTE. The operator will time out of can be set to close the gate. programming mode after 30 seconds. 2. Press the OPEN button. 3. Press the remote control button that you would like to program. Single button (SBC) as Program one remote control button as an 1. Press and release the LEARN button (operator will beep and green OPEN, CLOSE, and STOP open, close, and stop. XMITTER LED will light). NOTE. The operator will time out of programming mode after 30 seconds. 2. Press the remote control button that you would like to program. Three separate buttons as Program each remote control button as an 1. Press and release the LEARN button (operator will beep and green OPEN, CLOSE, and STOP open, close, and stop. XMITTER LED will light). NOTE. The operator will time out of programming mode after 30 seconds. 2. Press the OPEN, CLOSE, or STOP button, depending on the desired function. 3. Press the remote control button that you would like to program. The operator will automatically exit learn mode (operator will beep and green XMITTER LED will go out) if programming is successful. To program additional Security+ 2.00 remote controls or remote control buttons, repeat the programming steps above. Entering programming mode using external reset button or 3-button control station: 1. Make sure gate/door is closed. 2. Give the operator an OPEN command. 3. Within 30 seconds, when the gate/door is at the open limit press and release the RESET/STOP button twice to put the operator into programming mode. NOTE. The operator will time out of proaramminia mode after 30 seconds. NOTICE: This device complies with Part 15 of the FCC rules and Industry Canada's license -exempt RSSs. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device must be installed to ensure a minimum 20 cm (8 in.) distance is maintained between users/bystanders and device. This device has been tested and found to comply with the limits fora Class B digital device, pursuant to part 15 of the FCC rules and Industry Canada ICES standard.These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular Installation. If this equipment does cause harmful interference to radio ortelevision reception, which can be determined by turning the equipment off and on, the user is encouraged to tryto correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. 23 ot v .• V LiftMaster Internet Gateway (not provided) To program the operator to the LiftMaster Internet Gateway: Using the learn 'button on the opertaor's control board 1. Connect the ethernet cable to the LiftMaster Internet Gateway and the router. 2. Connect power to the LiftMaster Internet Gateway, 3. Create an online account by visiting www.myliftmaster.com. 4. Register the LiftMaster Internet Gateway. 5. Use an internet enabled computer or smartphone to add devices. The LiftMaster Internet Gateway will stay in learn mode for three minutes. 6. Press the Learn button twice on the primary operator (the operator will beep as it enters learn mode). The LiftMaster Internet Gateway will pair to ithe operator if it is within range and the operator will beep if programming is successful. Using the reset button on the operator 1. Connect the ethernet cable to the LiftMaster Internet Gateway and the router. 2. Connect power to the LiftMaster Internet Gateway. 3. Create an online account by visiting www.myliftmaster.com. 4. Register the LiftMaster Internet Gateway. 5. Use an internet enabled computer or smartphone to add devices. The LiftMaster Internet Gateway will stay in learn mode for three minutes. 6. Ensure gate is closed. 7. Give the operator an OPEN command. 8. Within 30 seconds, when the gate is at the open limit press and release the reset button 3 times (on primary gate) to put primary operator into High Band Learn Mode (the operator will beep as it enters learn mode). The LiftMaster Internet Gateway will pair to the operator if it is within range and the operator will beep if programming is successful. The status as shown by the LiftMaster Internet Gateway app will be either "open" for "closed". The gate operator can then be controlled through the LiftMaster Internet Gateway app. Erase All Codes 1. Press and release the LEARN button (operator will beep and green WITTER LED will light). 2. Press and hold the LEARN button again until the green WITTER LED flashes and then release the button (approximately 6 seconds). All remote control codes are now erased. I Erase Limits 1. To ierase the limits, press and hold the SET OPEN and SET CLOSE buttons simultaneously (5 seconds) until both the SET OPEN and SET CLOSE LEDs blink rapidly and the operator beeps. 2. Release the buttons and the SET OPEN and SET CLOSE LEDs will blink slowly indicating the limits will need to be set. 24 Constant Pressure Override (CPO) Constant Pressure Override is for use with KPW5 and KPW250 keypads (not provided). The KPW5/KPW250 wireless commercial keypads are security keypads and can only be programmed to ONE gate operator (see the KPW5/KPW250 manual for complete programming instructions). The Constant Pressure Override feature is intended to temporarily override a fault in the entrapment protection system, in order to operate the gate until the external entrapment protection device is realigned or repaired. Use the feature only in line of sight of the gate when no obstructions to travel are present. External entrapment protection devices include LiftMaster monitored photoelectric sensors and LiftMaster monitored wired and wireless edge sensors. Be sure to repair or replace these devices promptly if they are not working properly. To use Constant Pressure Override: 1. Enter a valid 4-digit PIN. 2. Press and hold # for 5 seconds to enter CPO. Continue to hold # to keep the operator in motion. A continuous tone will sound until limit is met and/or # is released. 3. The operator will stop when either the operator reaches a limit or the user releases #. Gate Hold Open Feature The gate hold open feature will disable the timer and keep the gate at the open limit. The gate hold open feature can be activated through the Reset Button as described on page 26 or through the KPW5 and KPW250 keypads (not provided). To use the gate hold open feature: 1. Enter a valid 4-digit PIN when the gate is at the Open Limit and the timer is running 2. The Operator will chirp indicating the timer is canceled. To restart the gate: 1. Re-enter the 4-digit PIN Activate a Hard input or a programmed remote To Remove and Erase Monitored Entrapment Protection Devices 1. Remove the entrapment protection device wires from the terminal block. 2. Press and release the SET OPEN and SET CLOSE buttons simultaneously. The SET OPEN and SET CLOSE LEDs will turn on (entering learn limit mode). 3. Press and release both SET OPEN and SET CLOSE buttons again to turn off the SET OPEN and SET CLOSE LEDs (exiting learn limit mode). ' EIVJDCo trot Board Overview1 SET,OPEN Button: The SET OPEN button sets the OPEN limit. See Adjust Limits section. Z2 SET�CLOSE Button: The SET CLOSE button sets the CLOSE limit. See Adjust Limits section.3 MOVE GATE Buttons: The MOVE GATE buttons will either open or close the gate when the operator is in LiL.LR W00jon. 4 BATT FAIL: • When AC power is OFF and battery voltage is critically low the gate will latch at a limit until AC power is restored or batteries voltage increases. •Option select switch set to OPEN forces gate to automatically open and then latch at the OPEN limit until AC power is restored or battery voltage increases. . Option select switch set to CLOSE forces gate to latch at CLOSE limit if at CLOSE limit or on next CLOSE command until AC power restored or battery voltage increases. • Cpnstant pressure on a hard command input overrides to open or close the gate. SCANNED • Critically low battery is less than 11.5 V BY 5 BIPART DELAY Switch: The LOCK/BIPART DELAY switch is used only for dual gates. See Bipart Delay section. St Lucie County 6 LEARN Button: The LEARN button is for programming remote controls and the network. 7 TIMER -TO -CLOSE dial: The TIMER -TO -CLOSE (TTC) dial can be set to automatically close the gate after a specified time period. The TTC is factory set to OF. If the TTC is set to the OFF position, then the gate will remain open until the operator receives another command from a control. Rotate the TIMER -TO - CLOSE dial to the desired setting. The range is 0 to 180 seconds, 0 seconds is OFF. NOTE: Any radio command, single button control, or CLOSE command on the control board prior to the TTC expiring will close the gate. The TTC is reset by any signals from the open controls, loops, close edges, and close photoelectric sensors (IR's). 8 REVERSAL FORCE dial: The REVERSAL FORCE dial fine tunes the force. See Force Adjustment section. 9 TEST BUTTONS: The TEST BUTTONS will operate the gate (OPEN, STOP and CLOSE). 10 STATUS LEDs: The STATUS LEDs indicate the status of the operator. See Status LED Chart in the Troubleshooting section. 11 DIAGNOSTICS Display: The diagnostics display will show the operator type, firmware version, and codes. The operator type will display as "SG" followed by a "12" which indicates the operator type as RSWI2UL. The firmware version will show after the operator type, example "1.2". 12 BA�CKDRIVE Switch: Set to MANUAL will allow the gate to be manually pushed open or closed if there is a loss of AC and battery power. Set to SECURE makes the gate difficult to push open or closed if there is a loss of AC and battery power. ST.LUCIE COUNTY PLAN REVIEW BLDG: DATE: ELE DATE;/ 2 PLUMB: DATE:_ _o MECH:�__ DATE: 25 Manual Disconnect Manual Disconnect Handle r Press the reset switch to RESET/DISCONNECT. Release the handle on the operator arm to allow the gate to be opened and closed manually. On a dual gate application the handle must be released on both operators. To resume normal function tighten the handle by pushing it down. r Normal operation Reset Switch The reset switch is located on the front of the operator and serves several functions. Toggling the reset switch will stop a moving gate during a normal open/ close cycle, like a stop button. The operator does not need to be reset after doing this. The reset switch will disable the gate in the present position and will energize the solenoid lock for two minutes and disable the mglock for two minutes. Operator Alarm / If acontact sensor detects an obstruction twice consecutively the alarm and (up to 5 minutes) and the operator will need to be reset. When jthe inherent force of the operator (RPWcurrent sensor) detects the following (twice consecutively) the alarm will sound (up to 5 minutes) and the operator will need to be reset. A. The operator arm or gate is incorrectly installed. B B. The gate does not meet specifications. C. Gate hinges are too tight or broken and the gate is not moving freely. D. The gate is moving and a car pushes the gate. E. Ai foreign object is on the gate frame while the gate is moving. F. The gate hits the driveway or curb and gets stuck or bent in an D awkward position. Remove any obstructions. Press the reset button to shut off the alarm and reset the operator. After the operator is reset, normal functions will resume. The operator alarm will beep 3 times with a command if the battery is P 6,^ low. j Remote control Reset/ Disconnect �� (I�I►1�1111lI ioilllllll{IINI�IIIIIE L Single Button Control (SBC) Functionality Once the remote control has been programmed the operator will operate as follows: Whenlgate is in the closed position, activation of the remote control button will open the gate. During the open cycle another activation of the remote control will stop the gate and the next activation of the remote control will close the gate. When'the gate is in the open position, activation of the remote control button will close the gate. If the remote control is activated while the gate is closing, the gate will stop and the next activation will open the gate. 26 i All control wiring used to connect external devices to Class 2 circuits of the operator must be (QPTZ) Power -Limited Circuit Cables, Type CL2, CL2P, CL213,!or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings. External control devices Access control device wiring Access control Uevlce EXIT (2 Terminals) This input is a soft open command (maintained switch does not override external safeties and does not reset alarm condition). Used for exit probe, telephone entry, external exit loop detector, or any device that would command the gate to open. . Opens a closing gate and holds open an open gate, if maintained, pa1uses Timer -to -Close at OPEN limit. SHADOW (2 Terminals) This input is used for external shadow loop detector when loop is positioned under the swing of the gate. • Holds open gate at open limit • Only active when the gate is at the OPEN limit, disregarded at all other times • Pauses Timer -to -Close at OPEN limit INTERRUPT (2 Terminals) This input is used for photoelectric sensors and external interrupt loop detector when loop is on the outside of the gate. Holds open gate at open limit Stops and reverses a closing gate to open limit Pauses Timer -to -Close at OPEN limit, activates quick close and anti - tailgate features when enabled on the expansion board Loop wiring 27 a A Maglock (2 Terminals, N.C. and COM) Relay contact output, Normally - closed (N.C.) output for maglocks. Relay activates prior to motor activation and during motor run. Relay is off when motor is off. Miscellaneous wiring. Three button control station .(4 Terminals) • OPEN and CUM: Opens a closed gate. Hard open (maintained switch overrides external safeties and resets alarm condition). If maintained, pauses Timer -to -Close at OPEN limit. Opens a closing gate and holds open an open gate (within line -of -sight). • CLOSE and COM: Closes an open gate. Hard close (maintained switch overrides external safeties and resets alarm condition within line -of -sight) • STOP and COMi Stops a moving gate. Hard stop (maintained switch overrides Open and.Close commands and resets alarm condition). If maintained, pauses Timer -to -Close at OPEN limit. Overrides Open and Close commands (within line -of -sight). Fire department input (2 Terminals) Acts as hard open. Maintained input overrides (ignores) external safeties (photoelectric sensor and edge) pauses Timer -to -Close momentary input logic as single button control and safeties remain active, re -enables Timer -to -Close. Accessory power 12 VDC, max 500 mA (4 Terminals) • SWITCHED: Switched ON with gate motion and at the open limit when Timer -to -Close is active. Turns off 5 seconds after motion. • UNSWITCHED:12 Vdc voltage out to power accessories, always ON. 28 CONTROLBOARD MAIN CONTROL BOARD MAOLOCK Three Billion Control Station \ )PEN Open Ct� . -OS Close COJ 3TOP Stop N.C. In . dMON Corn Fire Department MAIN CONTROL BOARD Accessory Power Switched Corn ( ) o¢ N Acc power.+.12 Vdc Corn 0 00. (-) o power .+12Vdo o,u� Accessory Power Unswitched IMPORTANT SAFETY INSTRUCTIONS WARNMA1,111610G To reduce the risk of SEVERE INJURY or DEATH: READ AND FOLLOW ALL INSTRUCTIONS. Test the gate operator monthly. The gate MUST reverse on contact ANY maintenance to the operator or in the area near the operator with an object or reverse when an object activates the noncontact MUST NOT be performed until disconnectingthe electrical power sensors. After adjusting the force or the limit of travel, retest the gate (AC or solar and battery) and locking -out the power via the operator operator. Failure to adjust and retest the gate operator properly can power switch. Upon completion of maintenance the area MUST be increase the risk of INJURY or DEATH. cleared and secured, at that time the unit may be returned to service. Use the manual disconnect release ONLY when the gate is NOT Disconnect power at the fuse box BEFORE proceeding. Operator moving. MUST be properly grounded and connected in accordance with KEEP GATES PROPERLY MAINTAINED. Read the owner's manual. national and local electrical codes. NOTE. The operator should be on Have a qualified service person make repairs to gate hardware. a separate fused line of adequate capacity. . ALL maintenance MUST be performed by a LiftMaster professional. NEVER let children operate or play with gate controls. Keep the . Activate gate ONLY when it can be seen clearly, is properly adjusted remote control away from children. and there are no obstructions to gate travel. ALWAYS keep people and. objects away from the gate. NO ONE . To reduce the risk of FIRE or INJURY to persons use ONLY LiftMaster SHOULD CROSS THE PATH OFTHE MOVING GATE. part 29-NP712 for replacement batteries. . The entrance is for vehicles ONLY. Pedestrians MUST use separate SAVE THESE INSTRUCTIONS. entrance. � CAl1TIt�N . 'ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment. Maintenance Chart Disconnect all power (AC, solar, battery) to the operator before servicing. The operator's AC Power switch ONLY turns off AC power to the control boardl and DOES NOT turn off battery power. ALWAYS disconnect the batteries to service the operator. DESCRIPTION Entrapment Protection Devices TASK Check and test inherent (built into the operator) and external devices for proper operation CHECK AT LEAST ONCE MONTHSMONTH 6 X EVERY ,. Warning Signs Make sure they are present and replace if worn or broken, see Accessories X Manual Disconnect Check and test for proper operation X Sprockets and Chains Check for excessive slack and lubricate X Gate Inspect for wear or damage; ensure it still complies with ASTM F2200, see page 5 X _ Accessories Check all for proper operation X Electrical Inspect all wire connections X Chassis Mounting Bolts Check for tightness X Operator Inspect for wear or damage X Batteries Replace X NOTES: • Severe or high cycle usage will require more frequent maintenance checks. • Iti is suggested that while at the site voltage readings be taken at the operator. Using a digital voltmeter, verify that the incoming voltage to the operator is within ten percent of the operator's rating. 29 Batteries Batteries will degrade over time depending on temperature and usage. The operator alarm will beep 3 times with a command if the battery is low. Batteries do not; perform well in extremely cold temperatures. For best performance, the batteries should be replaced every 3 years. Use only LiftMaster part 29-1\!PI712 for replacement batteries. The batteries contain lead and need to be disposed of properly. The operator comes with one 7AH battery. One 33AH Battery (Al2330SGLPK), 33AH Battery Harness (K94-37236) with additional battery tray (K10- 36183) may be used in place of the 7AH battery. I 30 To protect against fire and electrocution: For continued protection against fire: . DISCONNECT power (AC or solar and battery) BEFORE installing or Replace ONLY with fuse of same type and rating. servicing operator. Diagnostic Codes NOTE., When cycling or disconnecting power (ac/dc) to the control board, it is recommended that you unplug the J15 plug. To View the Codes The codes will show on the diagnostic display. TEST TEST then press resr Hermes BUTTONS and hold the BUrraxs ...then press OPEN button and hold the X suntil how'Er'o ♦� CLOSE button... shows on I Press land X ♦I the display. hold the STOP button... The operator will show the code sequence number followed by the code number: I CODE SEQUENCE NUMBER CODE NUMBER The first number shown Is the The second number shown after most recent code (example: the code sequence number Is '01')! The display will show the A SECOND the code Itself (31.99, example' sequence of codes that LATER.... '31'). Refer to the chart on the occurred starting with'01' and following page for an going up to code'20% explanation of each code. I � DIAGNOSTICS DIAGNOSTICS To Scroll Through the Saved Codes TEST BUTTONS TEST BUTTONS Press the OPEN button 0t1INI OX 11 XO to cycle to the most recent code ('01'), o Xo `" Press the CLOSE button MN111 0 o to cycle to the oldest code o 9 � 9 i The operator will only keep track of up to 20 codes, then will start saving over the oldest codes as new codes occur. 31 DIAGNOSTICS DISPLAY OPEN, CLOSE, & STOP BUTTONS To Exit Press and release the STOP button to exit. The display will also time out after two minutes of inactivity. To Reset the Code History 1. Press and hold the STOP button for six seconds. The display will show "Er" then "CL" alternately for six seconds. 2. Release the STOP button. The code history has now been reset and the display will show "-" until a new code occurs. 3. Press and release the STOP button to exit. Diagnostic Codes Table Some codes are saved in the code history and some are not. If a code is not saved it will briefly appear on the display as it occurs, then disappear. LiftMaster System Installed System 0 Informational ® External Entrapment ■ Inherent Entrapment Protection Protection --Code Main control board has experienced an internal Disconnect all power, wait 15 seconds, then reconnect power (reboot). If NO failure. issue continues, replace main control board. Absolute Position Encoder Error, not getting Check APE assembly and wiring connections. Replace the APE assembly YES position information from encoder if necessary. 35Hr���r Max -Run -Time Exceeded Error Check for an obstruction, then reprogram the limits. YES Product ID Error Was the control board just replaced? If so, erase limits, enter limit setup YES r q�yyppqg mode and set limits. If not, disconnect all power, wait 15 seconds, then reconnect power before changing product ID harness. Product ID Failure Unplug product ID harness then plug back in. Disconnect all power, wait YES 15 seconds, then reconnect power before replacing product ID harness. 38� Hard Stop Limit (Arm 1) Limit may be set too tightly against a non -resilient hard stop (re -adjust NO limit). Operator may be at end of travel (re -adjust mounting). H 46 Batteryovervolta a g Too much voltage on the battery.Check harness. Make sure there is NOT a YES ��"�'���u` 24V battery on a 12V system. *'411; Battery overcurrent Possible short of the battery charge harness. Check harness. Make sure YES you do NOT have a 12V battery on a 24V system. �iu� No battery at boot up 01 Check battery connections and installation. Replace batteries if depleted to YES ' less than 20V on a 24V system or less than 10V on a 12V system. Make sure there is NOT a single 12V battery on a 24V system. 43 Exit Loop Error Failure or missing loop (SHORT or OPEN - LiftMaster Plug-in Loop Detector only) Check loop wiring throughout connection. May be a short YES 44 Shadow Loop Error in the loop, or an open connection in the loop. 45 Interrupt Loop Error 46 Wireless edge battery low Replace batteries in wireless edge. YES Run-Distance Error The limits are less than the minimum requirement or longer than what YES was learned. Check limit positions and proper switch unction. Run - distance can be re learned by s distance he handing again AC/DC board supply dipped below allowable level. Review power supply Brownout occurred and wiring. If rebooting, ensure enough time for discharge of power to YES force afresh boot. Check the second operator for power. If OFF, restore power and try to run Wireless Second Operator Communication Error the system. If powered, deactivate the wireless feature and then re -learn YES the second operator. Minimum number of monitored entrapment Review monitored entrapment protection device connections. This swing i protection devices not installed. gate operator will operate only after installation of a minimum of one NO external safety device in either the open or close direction. CLOSE EYE/INTERRUPT held more than 3 minutes Check wired input on main control board; check for alignment or YES CLOSE EDGE held more than 3 minutes obstruction. OPEN EYE/EDGE held more than 3 minutes CLOSE EYE/INTERRUPT held more than 3 minutes Check wired input on expansion board; check for alignment or YES CLOSE EYE/EDGE held more than 3 minutes obstruction. OPEN EYE/EDGE held more than 3 minutes Wireless edge triggered more than 3 minutes Check wired input for wiring issue or obstruction. YES Wireless edge loss of monitoring Checkwireless edge inputs. YES 32 II' Meaning Solution Saved, Wireless edge triggered IF an obstruction occurred, no action required. If an obstruction did NOT NO occur, check inputs and wiring. CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC IF an obstruction occurred, no action required. If an obstruction did NOT NO CLOSE EDGE triggered, causing reversal, NO preventing close, or canceling TTC occur, check alignment, inputs, and wiring on main control board OPEN EYE/EDGE triggered, causing reversal or preventing opening CLOSE EYE/INTERRUPTtriggered, causing reversal, preventing close, or resetting TTC IF an obstruction occurred, no action required. If an obstruction did NOT NO CLOSE EYE/EDGE triggered, causing reversal and preventing close or canceling TTC occur, check alignment, inputs, and wiring on expansion board. OPEN EYE/EDGE triggered, causing reversal or preventing opening Close input (EYE/EDGE) communication fault from other operator Check inputs and communication method between operators, either wired bus or radio. Ensure operator is powered. May have to erase the wireless YES Open input (EYE/EDGE) communication fault from communication and reprogram the two operators. other operator Close input (EYE/EDGE) communication fault (expansion board) Check the connections between the main board and the expansion board. YES Open input (EYE/EDGE) communication fault (expansion board) Non -monitored device detected on the wireless Non -monitored contact closure devices are not supported. Make sure safety system connected devices are monitored. Check edges for proper orientation and YES resistive end cap connection. Check for obstruction. If no obstruction, check that the mechanical Force Reversal (Operator 1) assembly is engaged and free to move. See section on Limit and Force YES Adjustment, and Obstruction Test. Check for obstruction. If no obstruction, check the operator wiring and RPM / STALL Reversal (Operator 1) that the mechanical assembly is engaged and free to move. Replace APE YES assembly. 99 Normal Operation No action required YES 33 CoOtrol Board LEDs STATUS LEDS INPUT POWER OFF OFF state ON AC charger or Solar power available BAIT CHARGING OFF Not charging ON Three stage battery charging TIMER j i E, j OFF The'timer is disabled ON The timer is enabled MEDIUM BLINK (1 blink per second) The timer is running FAST BLINK (2 blinks per second) The timer is paused FASTEST BLINK (8 blinks per second) The timer is canceled GATE MOVING OFF The gate is stopped ON The gate is opening or closing MEDIUM BLINK (1 blink per second) Operator is in El (single entrapment) FASTEST BLINK (8 blinks per second) The operator is in E2 (double entrapment) BATT LOW i OFF No battery error ON Batterylow MEDIUM BLINK (1 blink per second) Battery critically low ACC PWR OVLD OFF Accessory power is okay ON Accessory overload protector opened 34 OPEN,, CLOSE, STOP INPUT OFF Input inactive ON Input active BLINK Input active on other operator FIRE DEPT INPUT OFF Input inactive ON Input active BLINK Input active on other operator EXIT OFF Input inactive ON Input active BLINK Input active on other operator SHADOW OFF Input inactive ON Input active BLINK Input active on other operator CLOSE EYES/INTERRUPT OFF Input inactive ON Input active BLINK Input active on other operator CLOSE EDGE OFF Input inactive ON Input active BLINK Input active on other operator OPEN EYES/EDGE OFF Input inactive ON Input active BLINK Input active on other operator LOCK OFF Maglock relay inactive ON Maglock relay active Troubleshooting Chart SYMPTOM POSSIBLE CAUSES SOLUTIONS Operator does not a. No power tocontrol board a. Check AC and battery power run and diagnostic b. Open fuse b. Check fuses display not on. c. If on battery power only, low or dead batteries c. Charge batteries by AC or solar power or replace batteries d. Defective control board d; Replace defective control board. Control board a. Reset switch is stuck a. Check reset switch powers up, but does b. Stop button active or jumper not in place for stop b. Check Stop button is not "stuck on", or verify that the stop button motor not circuit is a normally closed circuit, or put a jumper on the stop circuit run: c. If on battery power only, low or dead batteries c. Charges batteries by AC or solar power or replace batteries d. Open or Close input active d. Check all Open and Close inputs for a "stuck on" input e. Entrapment Protection Device active e. Check all Entrapment Protection Device inputs for a "stuck on" f. Vehicle loop detector or probe active sensor g. Defective control board f. Check all vehicle detector inputs for a "stuck on" detector g. Replace defective control board Gate moves, but a. Gate does not move to a limit position a. Use manual disconnect, manually move gate, and ensure gate cannot set correct b,. Gate is too difficult to move moves easily limit to limit. Repair gate as needed. limits. b. Gate must move easily and freely through its entire range, limit to limit. Repair gate as needed.. Gate does not fully a. Gate does not move to a limit position a. Use manual disconnect, manually move gate, and ensure gate open or fully close b. Gate is too difficult to move moves easily limit to limit. Repair gate as needed. when setting b. Gate must move easily and freely through its entire range, limit to limits. limit, Repair gate as needed. Operator does not a. Check Open and Close command .input LEDs a. Check all Open and Close inputs for a "stuck on" input respond to,,a wired b. Stop button is active b. Check Stop button is not "stuck on" control/command C. Reset button is stuck c. Check Reset button (example: Open, Close, SBC, etc.) d. If on battery power only, low or dead batteries d. Charges batteries by AC or solar power or replace batteries e. -Entrapment Protection Device active e. Check all Entrapment Protection Device inputs for a "stuck on" f. Vehicle loop detector or vehicle probe active sensor f. Check all vehicle detector inputs for a "stuck on" detector Operator does not a. Check XMITTER LED when wireless control is a. Activate wireless control and check XMITTER LED is on. Re -learn respond to a active wireless control/transmitter to control board. Replace wireless wireless control or b. Stop button is active control as needed. transmitter c. Reset button is stuck b, Check Stop button is not "stuck on" d. Poor radio reception c. Check Reset button d. Check if similar wired control operates correctly. Check if wireless controls works properly when within a few feet of operator. Check operator's antenna and antenna wire. Check other wireless controls or devices. Gate stops during a. Control (Open, Close) becoming active a. Check all Open and Close inputs for an active input travel and reverses immediately. b. Vehicle loop detector active battery b. Check all vehicle detector inputs for an active detector c. Low voltage c. Battery voltage must be 11.5 Vdc or higher. Charge batteries by AC or solar power or replace batteries Gate opens, but a. Open control active a. Check all Open inputs for an active input will not close with transmitter or b. Vehicle loop detector active b. Check all vehicle detector inputs for an active detector Timer -to -Close. c. Loss of AC power with AC FAIL set to OPEN c. Check AC power and AC Fail option setting d. Low battery with LOW BATT set to OPEN d. Check if AC power is available. If no AC power, then running on e. Fire Dept input active batteries and battery voltage must be 11.5 Vdc or higher. Charge f. Timer -to -Close not set batteries by AC or solar power or replace batteries. g. Close Entrapment Protection Device active e. Check Fire Dept input f. Check Timer -to -Close (TTC) setting g. Check all Entrapment Protection Device inputs for an active sensor 35 i Gate closes, but a. Vehicle loop detector active a. Check all vehicle detector inputs for an active detector will not open. b. Low battery with LOW BATT option set to CLOSE b. Check if AC power is available. If no AC power, then running on . j batteries and battery voltage must be 11.5 Vdc or higher. Charge batteries by AC or solar power or replace batteries. Obstruction in a. Force adjustment needed a. Refer to the Adjustment section to conduct the obstruction test and gate's path does perform the proper force adjustment that is needed. not cause gate to stop and reverse. Photoelectric does not a. Incorrect photoelectric sensor wiring a. Check photoelectric sensor wiring. Retest that obstructing sensor b. Defective photoelectric sensor photoelectric sensor causes moving gate to stop, and may reverse stop or reverse direction. gate. b. Replace defective photoelectric sensor. Retest that obstructing photoelectric sensor causes moving gate to stop, and may reverse t direction. Edge Sensor does a. Incorrect edge sensor wiring a. Check edge sensor wiring. Retest that activating edge sensor notlstop or reverse b. Defective edge sensor causes moving gate to stop and reverse direction. gate. b. Replace defective edge sensor. Retest that activating edge sensor causes moving gate to stop and reverse direction. Alarm sounds` for 5 a. Double entrapment occurred (two obstructions a. Check for cause of entrapment (obstruction) detection and correct. minutes or alarm within a single activation) Press the reset button to shut off alarm and reset the operator. sounds with a command. Alarm beeps three a. Low battery a. Check if AC power is available. If no AC power, then running on times with a batteries and battery voltage must be 11.5 Vdc or higher. Charge command. batteries by AC or solar power or replace batteries On'dual-gate a." Incorrect Bipart switch setting a. Change setting of both -operator's Bipart switch settings. One system, incorrect operator should have Bipart switch ON (operator that opens gate opens first or second) and the other operator should have Bipart switch OFF closes first. (operator that opens first). Alarm beeps when a. Expansion board setting a. Pre -warning is set to "ON" running. b. Constant pressure to open or close is given b. Constant pressure to open or closed is given Maglock not a. Maglockwired incorrectly a. Check that Maglock is wired to N.C. and COM terminals. Check working correctly. that Maglock has power (do; not power maglock from control board accessory power terminals). If shorting locks NO and COM wires does not activate Maglock, then replace Maglock or Maglock wiring (refer to Wiring Diagrams). Solenoid lock not woirking correctly. a. Solenoid wired incorrectly a. Check that Solenoid is wired to N.O. and COM terminals. Check that Solenoid has power (do not power solenoid from control boardaccessory power terminals). If shorting lock's NC and COM wires does not activate Solenoid, then replace Solenoid lock or Solenoid wiring (refer to Wiring Diagrams). Switched (SW) a. In limit setup mode a. Learn the limits Accessory power remaining on. Accessories connected to a. Normal behavior a. Move accessory to accessory power "ON" Switch (SW) Accessory power not working correctly, turning off, or resetting. 36 Accessories a. Accessory power protector active a.. Disconnect all accessory powered devices and measure accessory connected to Accessory b. Defective control board power voltage (should be 11.5 —17.5 Vdc). If voltage is correct, time, power connect accessories one at a measuring accessory voltage not working after every new connection. correctly, turning b. Replace defective control board off, or resetting. Solar operator not a. Insufficient panel wattage a. Add more solar panels getting enough day. b. Excessive accessory power draw b. Reduce the accessory power draw by using LiftMaster low power cycles per c. Old batteries accessories d. Solar panels are not getting enough sunlight c. Replace batteries d. Relocate the solar panels away from obstructions (trees, buildings, etc.) Solar operator, a. Insufficient panel wattage, a. Add more solar panels insufficient standby b. Excessive accessory power draw b. Reduce the accessory power draw by using LiftMaster low power time. c. Battery capacity too low accessories c. Use batteries with higher amp hour (AH) rating 37 Dual Gate Settings NOTE We recommend that all accessories and board configurations are set on the primary operator. Main control board Accessories Timer -to- Set the TTC dial to desired OFF Close setting Bi-kart Bi-Part Delay: ON (will open Bi-Part Delay: OFF (will open Delay last and close first) first and close last) Switch Tandem Mode: OFF Tandem Mode: OFF Synchronized Close: ON Synchronized Close: ON Types of Installations Standard Installation ACCESSORY PRIMARY OPERATOR SECONDARY OPERATOR Remote Controls Program remote Program remote controls 1 to 50 to the controls 51 to 100 to the primary operator. secondary operator LiftMaster Internet Program to primary Gateway operator. Garage and Gate Program to primary Monitor operator. Compact Installation The illustration is an example of a compact installation. If the operator arm will hit an obstruction when the gate is in the open position, refer to LiftMaster.com for compact installation instructions. Entrapment protection devices must be employed in this area. 38 Step 1 Determine Location for Co n1crete Pad and Operator Compact Installation Only DO NOT run the operator until instructed. Refer to the illustration to determine the measurements and location of the concrete pad. NOTE., When lifting the operator use the handle to avoid damaging the Step 2 Concrete Pad and Operator Attachment Compact Installation Only CHECK the national and local building codes before installation. NOTE. When lifting the operator use the handle to avoid damaging the operatlor 1. Install the electrical conduit. 2. Pour a concrete pad (reinforced concrete is recommended). The concrete pad should be 6 inches (15.2 cm) above the ground and deeper than the frost line. Ensure the pad is tall enough to avoid possible flooding. 3. Secure the operator to the concrete pad with appropriate fasteners. NOTE. An alternative to a concrete pad is to post mount the operator, see 4.5' (11.4 cm) 5j (14 cm) Goodall Location Mounting Footprint i 4' ) 1 10.cm l " ( L y _ w 1 (2 5 cm) 13.6' (3_ 4�� 12.2' (31 cm) I (18.5'cm (. _ (6.3cm) i �_ � ! , Cow-% (38cm) 10'(254•6') 14' ?1 (35.6 cm) Pad J-14.8' (37,6 cm) t— 24' (61 cm)—: Cover Mounting Distance 39 TOP VIEW OF OPERATOR AND GATE NOTE., There should only be a maximum of 4' (10.2 cm) from the 4' (10.2 cm) maximum Qenter of the hinge to the edge of the post or column. if the distance is greater than 4' (10.2 cm). entrapment Gate Hinge Center protection for this area Is required. Gate OpenPI 1/2' (67 3 cm) Output Shaft Center 90° —r vt (61 cm) Post Mount Step 3 Shorten the Operator Arm Compact Installation Only For a compact installation the operator arm will have to be shortened. 1. Take the operator arm apart and remove the inner sleeves from the outer tubing. 2. Out the outer tubing of the operator arm sections to the lengths shown, 3. Put the arm back together and adjust the arm to the measurements as shown. Use the set screws on the arm to temporarily hold the arm in place while determining the correct measurements. Step 4 Position the Gate Bracket CUT Long arm section CUT 0ZA 10' 22' (55.8 cm) (25.4 cm) 10.1 cm) CUT Short arm section O 20' (5u.8 cm) — -r (10.1 cm) Compact Installation Only NOTE: It may be necessary to attach horizontal reinforcement to the gate before attaching the gate bracket. Use the set screws on the arm to temporarily hold the arm in place while determining the correct measurements. 1. Position the operator arm onto the output shaft so that the pin slides into the slot. 2. Measure 33" (83.8 cm) along the gate length from the gate hinge center. 3. Measure 27.5" (69.9 cm) up from the concrete pad to the gate hinge position on the gate as shown. 4. Make sure the operator arm is level and tack weld the gate bracket in this position. Proceed to Step 5 of the installation. 40 r Step 8 Solar Panel(s) SOLAR PANELS ARE NOT PROVIDED. SEE ACCESSORIES SolariAppl(cation requirements: . A minimum of one 1OW solar panel (Model SP10W12V). A Itrlaximum of three 1OW solar panels in parallel (Model SP10W12V). Battery Harness (Model K94-37236). . One 7AH battery or one 33AH battery A jleater cannot be used with a solar application. Solar Zones Solar panel recommendations are based upon the average solar radiation and the temperature effects on batteries in the given zones as shown on the map below. Local geography and weather conditions may require additional solar panels. Solar powered gate operator installations are not supported in northern climates due to cold weather and a reduced number of hours of sunlight during the winter months. The cycles/day ratings are approximations. Ratings vary based on gate construction, installation, and temperature. Solar panels cannot be installed in areas that experience long periods of heavy fog, lake effect snow, or rain. zones ZONE 1 (B Hours of Sunlight/Day): Ideal for solar application ZONE 2 (4 Hours at Sunlight/Day): Recommended for solar application ZONE 3 (2 Hours of Sunlight/Day): Success of solar application will depend on type of gate operator and location of the solar panel NOT AVAILABLE 41 Typical System StandbyBattery Current Consumption System voltage 12V Main board with no radios programmed 4.2 mA 0*or more LiftMaster@ remote controls programmed +1.5 mA My00 device or wireless dual gate programmed +3.9 mA Expansion board +18.5 mA Per loop detector LOOPDETLM (up to 3 loop detectors can be plugged in to the expansion board) +6.6 mA l Add up current draw by feature and accessory to determine total current draw NOTE; The use of photoelectric sensor heaters (models LMRRUL and LMTBUL) is NOT recommended in solar applications. SOLAR GATE CYCLES PER DAY BATTERY CURRENT ZONE 1 ZONE 2 ZONE 3 DRAW-- (mA) 7AH batteries °Two7AH batteries 33AH batteries 7AH batteries Two7AH batteries 33AH batteries 7AH batteries Two7AH batteries 33AH batteries 6 41 46.. 48- 24 27 29 .. -1-1 - - 11__... 25 34 39 41 18 21 22 — 10W SOLAR PANEL 30 33 37 39 17 19 21 — 50 26 30 32- 11 13 15 100 11 14 16 _ — 20W SOLAR 6 50 , 50 50 47 50 50 19 --24 _ 21 PANEL(Two 25 50 50 50 40 50 50 13 - 18 0- 1 6W 12V 30 50 50 50 38 50 50 12 17 20 panels in 100 42 ' 50 50 15 26 32 — parallel) 200 25 34- 30W SOLAR 6 50 50 50 5,0 50 50 24` 37 -__. 44 PANEL 25 50 50 50 50 50 50 - 18 — 30 37 - (Three 10W 30 50 50 50 49 50 50 16 28 35 12V panels 000 50 50 50 25 50 50 in ,parallel) 200 24 50 50 17 All numbers are estimates. Actual results may vary. 42 s The location of the panel(s) is critical to the success of the installation. In general, the panel(s) should be mounted using the provided angle bracket facing due south. The solar panel(s) should be mounted in an area clear of all obstructions and shade from buildings and trees. If the panel(s) is not casting a shadow, the battery is not being charged. NOTE: Tall trees or buildings that do not shade the solar panel(s) in the summer could shade the solar panel(s) during the winter months when the sun sits lower in the sky. MAXIMUM i WATTS OF PANELSWIRE GAUGE WIRE LENGTH i WATTS OF 60 WATTS OF PANELS 16 235 (71.6 m) 115 (35.1 m) 80 (24.4 m) 14 375 (114.3 m) 190 (57,9 m) 125 (38.1 m) 12 600 (182.9 m) 300 (91.4 m) 200 (61 m) 10 940 (286.5 m) 475 (144.8 m) 315 (96 m) Chart assumes: copper wire, 65°C, 5% drop, 30V nominal TIP: The area around the solar panel(s) should be clear of shadows or obstructions In tha can M,a }fill-- —f M —f Installation Solar panel(s) MUST be installed facing south. Use a compass to determine direction. Below are general instructions for installing the solaianel(s). Your installation may vary slightly depending on the solar panel purchased. 1. Position the mounting bracket on the mounting surface. Mark and drill holes. 2. Secure the solar panel to the mounting bracket using the hex bolts, hex nuts and washers provided. 3. Secure the solar panel to the mounting surface using lag screws provided. Mounted Panel Must Face South Mounting Surface 43 ummer Sun Height ter Sun Height .o b Up to15' South TIP. To optimize the system for winter operation the angle can be Increased an additional 15' (solar panel(s) sits more vertical). Wire the Batteries Solar panel applications require the Solar Harness Kit model K94-37236, see Accessories. TO InpuBo coot oATT DI �boa d input oncoM "I board Lo Input on control WER" To 'BATT D POWER" To "BATT DC board + + 30 + + 30 + + 30 BATT DC POWER 32 BATT OC POWE 32 BATT 00 POWER 32 Black Jumper wire for two 7AH battery connections Red jumper Wire for two 7AH batt connections ©O To Solar Panels i 00 ONE 7AH BATTERY i Wire the Solar R 10W APPLICATION IN PARALLEL iun J�ery(les) To Ba IOW TWO 7AH BATTERIES IN PARALLEL mels 20W APPLICATION IN PARALLEL To Battery(les) To B tow IOW Fuse I Red wire for I ' 33AH battery connections To Solar Panels To Solar Panels Black wire for 33AH battery 0 o connections 00 0 0 ONE 33AH BATTERY 30W APPLICATION IN PARALLEL 20W tow low iuvv Proceed to the Dual Gate section (it applicable) or proceed to the Adjustment section. 44 low 20W ,r i Remote Control To set the limits using a remote control, first you will need a 3-button remote control that has been programmed for OPEN, CLOSE, and STOP. Refer to the Programming section. Initial Limits and Force Adjustment Adjust the limits For dual gate applications the limits will have to be set for each operator. The gate MUST be attached to the operator before setting the limits and force. Ensure the gate is. closed. 1. Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode. 2. Press and hold the OPEN or CLOSE button on the remote control until the gate reaches the desired open position. The gate can be jogged back and forth using the OPEN and CLOSE buttons on the remote control. 3. Once the gate is in the desired open position, press and release the STOP button on the remote control. 4. Press and release the OPEN button on the remote control again to set the open limit. 5. Press and hold the CLOSE or OPEN button on the remote control urttil the gate reaches the desired close position. The gate can be logged back and forth using the OPEN and CLOSE buttons on the remote control. 6. Once the gate is in the desired close position, press and release the STOP button on the remote control. 7. Press and release the CLOSE button on the remote control again to set the close limit. 8. Cycle the gate open and close. This automatically sets the force. Whenj limits are set properly the operator will automatically exit limit setting mode. Refer to the Adjustment section and follow the instructions for Fine Tune the Force and Obstruction Test. Perform the "Obstruction Test' after every limit and force setting adjustment. 45 If the limits have already been set the operator will exit the limit setting mode after resetting each limit. Set the Close Limit Only 1. Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode. 2. Press and hold the CLOSE button on the remote control until the gate reaches the desired close position. The gate can be jogged back and forth using the OPEN and CLOSE buttons on the remote control. 3. Once the gate is in the desired close position, press and release the STOP button on the remote control. 4. Press and release the CLOSE button on the remote control again to set the close limit. When the close limit is set properly the operator will automatically exit limit setting mode. Set the Open Limit Only 1. Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode. 2. Press and hold the OPEN button on the remote control until the, gate reaches the desired open position. The gate can be jogged back and forth using the OPEN and CLOSE.buftons on the remote control. 3. Once the gate is in the desired open position, press and release the STOP button on the remote control. 4. Press and release the OPEN button on the remote control again to set the open limit. When the open limit is set properly the operator will automatically exit limit setting mode. 3-Button Remote Control programmed for OPEN, CLOSE, and STOP To protect against fire and eleclt r o c ution: . DISCONNECT power (AC or solar and battery) BEFORE installing or servicing operator. For continued protection against firer Replace ONLY with fuse of same type and rating. Transformer To J25 Antenna Coaxial Antenna Cable aer aa� ssr arose % Eti: LEARN 8n MR NIX w- TIME1 eEVENSAL aAre Aa °d1TTPAi 6NplOfWG ° OPEN and COM: Hard Open (line -of -sight) and OM: Hard Close Control Board (CLOSE tt STOP andgCOM: Hard Stop NIT: exit : Soft Open (used for m telephone entry, external exit - loop detector, or any device that would command the V ° gate to open) Photoelectric Sensors m7-0 m : ZI Edge I I Red Product ID 12V 7AH Battery Black ODodeing W R. Piezo Alarm I I ________________I , ToPin 2 To -- I I} I E O Reset Swit One, two, or three 10W Solar Panels wired Accessory Power In parallel (30W maximum) Outlets 0 Expansion Board (Optional) Loop RUMMM Detector i� SHADOW INTEAAUFT °LL1 I Heater A o z Input Power Connection Wire Loop Me Loop 46 I I Field Wiring - t-1 Edl Primary/secondarylink Shielded _ to other gate operator Twisted Ground the shield of the cable Pair Cable to the chassis ground of each operator. Wireless Edge T n Eye Eye or Edge _€;I Eye or Edge 9 sludge Cover K13-36117-1 • Cludge Assembly Release Handle , �� 0061 II— 0060 0 ------------ Output Shaft wilh sprocket, ---" "I #35limit chain, and APB sprocket roll pin K77-36539 I ` I i I � c Geer Box (top) K32-34656.1 Gear Reducer Sprockets with set screws and key K70.35678-1 1 #41 Drive Chain and Masla4lnk K19.41043M I i I Battery Tray K10-36395 Gear Reducer (bottom) K32.36513.1 NOT SHOWN K94-37336 Wiring Harness with product ID assembly K94-37230 Battery Harness (for 7AH batteries) K94-37236 Battery Harness (far 33AH batteries) Alarm with harness K94-35152 Electrical Box K77-37336 Keys 0118 -I 47 Battery, 7AH,12 Vdc 29-NP712 APB Encoder with cable K776-34644 .'------------- APE Assembly 1 KIA6408 1 1 I I � i I I • �� `------- Mahn Board with heat sink K1D8389-1CC Plug -In Transformer APOW3 Operator Cover with labels, keys, and lock assembly K77-39430 Antenna K77.36541 O Dust Guard K13-34729 -1 r nent Protection Remote Controls LiftMaster monitored through beam LiftMaster offers a variety of LiftMaster remote controls to satisfy your photoelectric sensor application needs. Single -button to 4-button, visor or key chain. The Model LMTBUL following remote controls are compatible with operators manufactured by LiftMaster after 1993. Contact your authorized LiftMaster dealer for additional details and options. LiftMaster monitored retro-reflective 3-button remote control photoelectric sensor The 3-button remote control can be programmed to v ! Model LMRRUL. control the operator. Includes visor clip. Model 893MAX 3-button mini -remote control LiftMaster Monitered Commercial Protector The 3-button remote control can be programmed to System@ control.the operator. Includes key ring and fastening Models CPS-UN4 and CPSUN4G strip. Model 890MAX Security+ 2.00 learning remote controls LiftMaster monitored wireless edge kit One button can control a gate operator and the other (transmitter and receiver) (s) can control garage door(s). It can also be programmed to Security+® or Security+ 2.00 code Model LMWEKITU format.- Models 892LT and 894LT LiftMaster monitored wireless edge transmitter Keyless entry Model LMWETXU Enables homeowner to operate gate operator from outside by entering a 4-digit code on a specially Large profile monitored edge (82 ft. roll) designed keypad. Model L50 Model 877MAX Large profile ends kit (10 pair) Model L50E .Small profile monitored edge (82 ft. roll) Model S50 Small profile ends kit (10 pair) Model S50E Plastic'channel 8 ft. (2.4 m) for both small and large profile edges (pack of 10). Model L50CHP Aluminum channel 10 ft. (3.1 m) for both small and large edge profiles (pack of 8). Model 150C HAL Edge cutting tool Model STOOL LiftMaster large profile monitored edges (4111.,51, 6it.) Model Li504AL, L505AL, L506AL LiftMaster small profile monitored edges (411.,511t., 611t.) Model S504AL, S505AL, S506AL 48 Remote antenna extension kit The remote antenna extension kit allows the antenna to be remotely installed. Commercial access control receiver Access control receiver for up to 1,000 devices (any combination of remote controls and wireless keyless entries). Model STAR1000 Plug-in loop detector Low power. Conveniently plugs into existing control board. Model LOOPDETLM Loop Detector Low power loop detectors mounted and wired separately inside control box. LiftMaster low power accessory. Model LD7LP Vehicle sensing probe The vehicle sensing probe is buried in the ground and can detect a car as it approaches and will then open the gate. Model CP3 Solar panel kit This kit is to replace or add a solar panel to the operator application. 60W maximum for 24 Vdc operators and 30W maximum for 12 Vdc operators. Requires a 33AH battery harness. Models SP10W12V (10 Watt, 12V) and SP20W12V (20 Watt, 12V) Magnetic gate lock Outdoor magnetic lock, transformer, junction box, mounting plate and hardware. Not for use with Solar Applications. Must be powered separately. Model MG1300 Heater The heater keeps the gearbox and batteries at a suitable temperature when the outside temperature is below -40F (-200C). The thermostat MUST be set between 45OF and 60°F (7°C and 15.5°C) to ensure proper gate operation. The heater can be powered by 110 to 250 Vac. Model HTR Wire harness Betweenlmain control board and expansion board. Model K94- 34778 I LiftMaster® internet gateway Internet enabled accessory which connects to the computer and allows you to monitor and control gate operators and lighting accessories enabled by MyQ@ technology. Model 828LM Expansion board Additional programming features including external loops, plug-in loops, auxiliary relays, and inputs for additional controls and entrapment protection devices. Model K1D8387-1CC Wireless commercial keypad Durable wireless keypad with blue LED backlight metal keypad, zinc -alloy metal front cover and 5 year 9V lithium battery. Security+ 2.00 compatible. Model KPW250 Warning sign a t a Model 40-39235 4�il0i�i�rym�C eN Batteries Gate access system batteries replace or upgrade the gate operator batteries. Two identical 12 Vdc batteries are required for each gate operator. Do not mix 7AH and 33AH batteries within a gate operator. 7AH batteries Standard 7 AMP -Hour Battery, 12 Vdc, to replace original batteries provided with operator. Reuse existing harnesses. Models 29-NP712 (1) and K74-30762 (2) 33AH batteries Upgrade 33 AMP -Hour Battery, 12 Vdc. Ideal for solar applications and extended battery backup. Two required. Model A12330SGLPK 49 Battery tray For use with 33AH batteries. Model K10-36183 Universal solar wire harness kit For 7AH and 33AH applications. Model K94-37236 ■ MGMI.c ■IWCQ■ 1.112 BEI W%A WNaN5aE5ar LiftMa'ster warrants to the first purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or, workmanship for a period of THREE years from the date of purchase. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing. Failure to comply strictly with those instructions will void this limited warranty in its entirety. If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-2806, toll free, before dismantling this product. Then send this product, pre -paid and insured, to our service center for warranty repair. You will be advised of shipping instructions when you call. Please include a brief description of the problem and a dated proof -of purchase receipt with any product returned for warranty repair.1Products returned to Seller for warranty repair, which upon receipt by Seller are confirmed to be defective and covered by this limited warranty, will be repaired or replaced (at Seller's sole option) at no cost to you and returned pre -paid. Defective parts will be repaired or replaced with new or factory- rebuilt,parts at Seller's sole option. ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES .OF MERCHANTABILITY AND FITNESS FOR AIPARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE THREE YEAR LIMITED WARRANTY PERIOD SET FORTH ABOVE, AND NO IMPLIED WARRANTIES WILL EXIST OR APPLY AFTER SUCH PERIOD. Some states do not allow limitations on how long an implied warranty lasts, so the above ,limitation may not apply to you. THIS LIMITED WARRANTY DOES NOT COVER NON -DEFECT DAMAGE, DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT, OR REPLACEMENT OF BATTERIES. THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GATE OR GATE HARDWARE, INCLUDING BUT NOT LIMITED TO THE GATE SPRINGS, GATE ROLLERS, GATE ALIGNMENT OR HINGES. THIS LIMITED WARRANTY ALSO DOES NOT COVER ANY PROBLEMS CAUSED BY INTERFERENCE. ANY SERVICE CALL THAT DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT IN A FEE TO YOU. UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN CONNECTION WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER'S LIABILITY FOR BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 50 I 51 300 Windsor Drive Oak Brook, IL 60523 LiftMaster.com © 2018, The Chamberlain Group, Inc. - All Rights Reserved 01-39378B