BLOWER DOOR TES u FORM
Clouse infltration `hest Cevf1 ication
PrescAptive and Performance Method
Dated perrrrio
Contractor: C.11A J 5
iA cTJ
RECEIVED
AUG 2 0 2019
ST. Lucie County, Permitting
I )- 0-386
70 O
Job address: 81 0 o M !jL Ck U,,, Pro f S+ L ,,a e, rri- -7
Cone ruction: (✓D New Construction — Complete Enlisting — After Addition
t souse Infiltration Vest Results 5LC Climate Zone 2
cpm (50) = Z o Test Date:
volume =
ACH (50) = CFM (50) n 650 / Volume = - z Mechanical Ventilation required less -than 3 ACH
gassing results must be & AP CH (50) or less Pe'pPass ( ) Fail
FBC, Energy
The Building or dwelling unit shall be tested and verified as having an air leakage rate o not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through S. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FEC, Rasidential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building, Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
I
i estinR Cornpanv
Company Name: Pro -Duct Services
Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with tion R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: (Martin Klein
Licdnse/Certification #: 5061633