HomeMy WebLinkAboutEVALUATION REPORT - UNDERLAYMEDNTSCertificate of Authorization bur Drive CREEK17520 Edinburgh Drive. Tampa, FL 33647 TECHNICAL SERVICES, LLC (813) 480-3421 i EVALUATION REPORT FLORIDA BUILDING CODE, C EDITION (2017) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017 1 Owens Corning Parkway Toledo, OH 43657 &� NNE® (800) 438-7465 www.owenscorning.com BY Manufacturing Location: Brentwood, NH St Lucie County Houston, TX Quality Asstirance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1; 1507.1.1 Properties: Physical properties REFERENCES Enti Report No. Standard Year PRI Construction Materials Technologies (TST5878) NEI-039-02-01 ASTM D 1970. 2015 PRI Construction Materials Technologies (TST5878) NEI-042-02-01REV2 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) NEI-045-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) NEI-045-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) NEI-053-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) NEI-053-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) NEI-093-02-02 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-213-02-01 .ASTM D 1623 2009 PRI Construction Materials Technologies (TST5878) OCF-237-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST5878) OCF-252-02-01 ASTM D.4798 2001 PRI Construction Materials Technologies (TST5878) OCF-252-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-253-02-02 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-272-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) OCF-296-02-02 ICC-ES AC 188' 2012 [CC -ES AC 48 2012 PRI Construction Materials Technologies (TST5878) OCF-297-02-01.1 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-318-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-320-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) OCF-320-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) OCF-321-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies (TST5878) OCF-322-02-01 UL 1897 2012 PRI Construction 'Determined Materials Technologies (TST5878) OCF-355-02-01 UL 1897 2012 to be equivalent to ASTM D 226-09, Type I and it OCR14062.8a FL9777-R11 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any ]product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not i specifically addressed herein. .OWENS CORNING ROOFING AND ASPHALT LLC 1.., K WeatherLock@ Self -Sealing Ice & Water Barriers TECHNICAL SERVICES, LLC PRODUCTDESCRIPTION AND LIMITS OF USE WeatherLock@ G WeatherLock® G is an ASTM D 1970 self-adhesive underlayment constructed from SBS (Brentwood, NH)' modified asphalt, :a fiberglass mat reinforcement and 'surfaced With granules. -The product is supplied in 2-sq. rolls With nominaldimensions of 3-ft x 66.7-ft. WeatherLock@ G is permitted to be used as prescribed in FBC Section-1507.1.1. for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock@ Mat WeatherLock@Mat is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood, NH'or. . SBS modified asphalt with a fiberglass mat reinforcement. The. product is supplied in 1- Houston, 7X) sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions of 3-ftx 66.7-ft. WeatherLock® Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall. be limited to a maximum' 30 days. WeatherLock@ Metal. WeatherLock@. Metal is -an ASTM D 1970 self-adhesive undedayment constructed from (Brentwood, NH) SBS modified asphalt With a fiberglass mat reinforcement and plastic film -surface: The product is -supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.7-ft. i WeatherLock@ Metal is .permitted to be used as prescribed in FBC Section 1507.1.1 for ( mechanically attached'roof coverings.. Exposure on: the roof deck shall be limited to a ' " maximum 90 days. WeatherLock®. WeatherLock®.Specialty Tile &Metal is an ASTM D 1970 self-adhesive underlayment Specialty Tile & Metal constructed from SBS modified asphalt and surfaced with a' non -woven polyester fabric.-, (Brentwood,'NH or The: product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x.71.3-ft. Houston, TX) -WeatherLock@ Specialty Tile & Metal is permitted to be used as prescribed in FBC { Section 1507.1.1. WeatherLock@ Specialty Tile & Metal is permitted to be used with adhered clay .or concrete the roofing using either ICP. Adhesives Polyset AH-160: (ICP . . I Adhesives. and Sealants, Inc.) or TILE BONDTm-Roof Tile,Adhesive (The Dow Chemical Company). Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall. be 6:12 when used with clay or concrete tile installations without battens.. Tile shall be stored on battens for roof slopes. greater than 6:12..Tiles shall not be stacked greater 10 tiles per stack-.. . WeatherLock@ G (High WeatherLock@ G (High Tear) is a self -adhered, undedayment used as an alternative to Tear) a .. ASTM D'226, Type I or Type.11 roofing felt and ASTM D 1970 self -adhering polymer (Houston, TX) - modified bitumen underlayment. The undedayment is composed of SBS modified Oct halt with a fib It' t I f p . . erg ass, ma m erna rem orcement and .is surfaced with granules. The - product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal I dimensions of 3-ft x 654 WeatherLock@ .G (High: Tear). is permitted to be, -used as .prescribed in FBC Section, 1607.1.1 for mechanically. attached .roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. u OCI214002.8a FL9777-R11 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid: This -evaluation Ireport does. notexpress nor imply warranty, -installation, recommended use,. or other product attributes that are not specifically addressed.herein. CREEK- TECHNICAL SERVICES, LLC i PRODUCT APPLICATION OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock® Self -Sealing Ice & Water Barriers Min. Roof Slope: 2:12 in accordance with the FBC. Application: All underlayments shall be installed in accordance with the FBC. Deck substrates -shall be clean, dry,' and free from .any irregularities and -debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the undedayment shall be unrolled -and allowed to relax; for a .minimum of 3-5 minutes. The underlayment shall be installed With the release backer removed and pressed firmly into place to ensure complete contact with the:deck. The underlayment shall be installed with the roll length: parallel to the eave, starting at the eave, and with minimum 3" side laps and minimum 6" end. laps -staggered min. 6-ft.from.preceding course. Additionally, if applying WeatherLock® Specialty Tile & Metal; end laps shall be primed with ASTM D 41 primer. or sealed with asphalt roof cement a minimum of 3-4 inches across the width. of the lap. It is permissible'to back nail the undedayment 12-inches on -center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). Additionally, WeatherLock® Specialty. Tile .& Metal shall be back nailed when installed on roof slopes greater than 3:12. Min. Application. 40"F; Contact the manufacturer when installing. at temperatures below the minimum Temperature: application temperature. WIND RESISTANCE The Maximum Design Pressures. shown below were calculated using.a 2:1. margin of safety per FBC Section 1504.9. . Underlavment System No.1 — WeatherLock Specialty Tile &Metal Only ' Roof Deck: Min. 15/32-inch CDX plywood attached to wood -supports spaced a maximum 24" o.c. Underlayment: WeatherLock® Specialty .Tile & Metal shall be applied in accordance with manufacturer's, installation. instructions to the fastened deck and. backnailed along the i selvage with .minimum 12ga:, 1-1/4-inch galvanized ring shank roofing nails through optionally primed, 329a. x 1-5/8-inch 0 tin-. caps spaced 12" o.c. The. . applied undedayment shall be rolled with a minimum 751b steel roller immediately following' application.. Maximum.Design 142..5.psf Pressure: a OCR14002.8a FL9777-R11 Page 3 of 4 This'evaluation'eport,is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical- Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.. This. evaluation report. does not,express nor imply -warranty, installation, recommended use, or other.producf attributes that are. not i specifically -addressed herein. . 1 CREEK OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock® Self -Sealing Ice & Water Barriers TECHNICAL SERVICES, LLC GENERAL LIMITATIONS 1) This evaluation report is not use in. the HVHZ. " 2) Fire Classification is not within the scope of this evaluation. . 3) Installation of the evaluated product shall comply with this report, the FBC,.and.the manufacturer's published application instructions. Where discrepancies exist between .these sources, the more'restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. _ 5) `. The space under the deck'area shall be properly, ventilated in accordance with the FBC requirements. 6) All side lap seams'shall. be installed to shed water from the deck. 7) The underlayment may be used as'described in other current FBC product approval documents. 8) , Design wind -load pressures shall be determined for components and cladding.in accordance with FBC . 1669. I 9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components.and cladding. 1,0) Miaximum.Design Pressures. for 'a given underlaymenf shall meet or exceed the design wind .loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under a.quality'assurance program incompliance with Rule 61 G20-3. I COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance. with. the Florida. Building I Code 6' Edition (2017) as evidenced in the,referenced documents submitted -by the named manufacturer. �. RY R. PR i, C E ius 20.17.10.11 d No.-74021 % 09:06:29 041001 STATE OF . •�� D,ri'.•.� p. �.` Zachary R: Priest, P:E. �0i�F ' O R t �•••���% Florida RegistrationNo.:74021 %` Organization No. ANE9641 I . CERTIFICATION OF INDEPENDENCE f CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing I products under this evaluation. CREEK Technical' Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a .financial interest in any company manufacturing or distributing products under -this evaluation. Zachary_ R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. I END OF REPORT OCR14002.8a FL9777-R11 Page 4 of 4 This evaluation report, Is provided for State of Florida product approval under Rule 61G20-3. The -manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid: jThis evaluation. report does not express nor. imply warranty, installation, recommended use, or other.product attributes that are. not specifically addressed herein.