HomeMy WebLinkAboutNOA - 24 GA STEEL PANEL OVER WOOD DECKi
FILE COPY
MIAMFDADE
MIAMI' DADE COUNTY
® PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES '(RER) 11805 $W 26 Street, Room 208 -
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
RECEivE� 86) 315-2590 F (786) 315.2599
NOTICE OF ACCEPTANCE (NOA)'miamldade. ov/econom
NOV 0 2 2018
JA Taylor Roofing .
13Y
302 Melton Drive ST. l.ude County, �epMitting t Lucie County
Ft. Pierce; FL 34982 -
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County- and other areas where allowed by the.Authority Having Jurisdiction
i
This NOA shall not'be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have.this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of:such testing and the AHJ may immediately.revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade. County Product Control Section that this product or material fails to meet the requirements
of the' applicable building code.
This product is approved as described herein, and has been designed to comply. with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code. '
DESCRIPTION: Edge-Loc 1.0 x 16" wide x 24ga. Steel Panel over Wood Deck
LABELING: Each unit shall bear a permanent label with the manufacturer's name .br logo, ,city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA. shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this 'product..'
I -
TERMINATION of this NOA will occur after the expiration'date or if there'has been a revision or change in .the .
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement -of any product, for
sales, advertising or any other purposes shall automatically terminate this. NOA. Failure to comply with any section of
this NOA shall because for termination and removal of NOA..
ADVERTISEMENT: The NOA -number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion. of the. NOA is displayed, then it shall be done
in its e'tirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the -request of the,Building Official.
This revises NOA No...l3-l'015.05 and consists of pages 1 through-5.
The.sub� miffed documentationwas reviewed by Juan E. Collao, R.A.
j
Mu�•o�►oe counmr NOA No 14-0416.01
197�18�2(J/y Expiration Date: 01/69/19
Approval Date':.06/05/14
Paged of 5
I
I
ROOFING ASSEMBLY APPROVAL
.
I.
Catekory: Roofing
` Sub-Catezory:- Metal, Panels (Non -Structural).
Materials: Steel
DeckType:.. Wood
Maximum Design Pressure —101 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product. Dimensions Specifications
. Description
Edge-Loc 1.0 Length: various _ -
TAS.110 . Corrosion resistant,prefinished, coated
Width: 16"
galvanized, galvalume, standing seam, metal
i Height: I".
panels.
Thickness 0.024" (24 ga.)
Min. Yield Strength: 50 ksi
I
Trim Pieces Length: varies
N/A Corrosion resistant; prefinished; coated
Width: varies
galvanized; galvalume, standing seam, metal
Thickness. 0.024"_(24'ga.)
panels.
EVIDENCE SUBMITTED:.•
i
j . Test Agency Test.Identifier
Test. Name/Revort Date.
Valspar 433X515
ASTM B 117 11/21/11
433Bi73
ASTM D 4587, ASTM G 23 11/21/11
i
Force Engineering & Testing 72-0314T-06A-C
-TAS 125 03/24/07
Inc.
Fatabaugh Engineering and T158-07A
TAS 100 04/14/07
Testing Inc.
I
,
I
i
I
I
I
NOA No.: 14-0416.01
MLAMI-nanE.Co
Expiration Date: 01/09/19
Approval Date: 06/05/14
i
I
i
Page 2 of 5
I
}
i
I
..
I
APPROVED 'ASSEMBLIES:
System:
Edge-Loc 1.0 Panel x 16". Wide x 24 ga. Steel
Deck Type:
Wood, Non -Insulated
Deck Description:
New Construction '19/32" or greater plywood or wood plank, or for re -roofing 15/32" or
greater plywood. -
Slope Range:
2: 12 or greater
Maximum Uplift
: See Table A below
Pressure: ..
Deck Attachment:
In accordance. with applicable Building Code, but in no case shall it be less than 8d ring
.,.shank nails spaced 6" o.a. In reroofing, where the deck is less than 19/32"thick (Minimum
15/32") The above attachment method -must be in addition to existing attachment.
Underlayment:
Minimum underlayment shall be an ASTM D 226 Type :II installed with a minimum 4"
side -lap and 6" end -laps. Underlaymentshall be fastened with corrosion resistant tin -caps
and 12 gauge 1 '/a" annular ring -shank nails, spaced 6" oX. at all laps and two. staggered
I
rows 12" o.c. in the field of the roll. Or, any approved underlayment having a current NOA.
Fire Barrier Board:.
Any approved fire barrier having a current NOA. Refer -to a current fire directory listing for
fire 'ratings of this roofing system assembly as well as the location of the fire barrier within
I
the'assembly. See Limitation L
Valleys:
Valley construction shall be in compliance with Roofing Application Standard RAS 133
and with PAC ,Contractors Association's current published installation instructions:.:.
Metal Panels and
Install the "Edge-Loc 1.0 Panel" and accessories in compliance with the current published
Accessories:
installation instructions and details in PAC Contractors Association's Installation Manual.
Flashings, penetrations, valley construction and .other details shall be constructed in
1
compliance .with Roofing Application Standard RAS 133.
Panels shall be secured at a spacing listed below in Table A with. #10-13 x 1" pancake head
screws of sufficient length to penetrate through the sheathing. a minimum 3/16 of an inch.
The adjacent panel shall overlap and be secured to each other when The female rib of panel
I
is snapped over the male rib of panel.
TABLE A
MAXIMUM DESIGN PRESSURES
Roof Areas
Field
Perimeter and Corner'.
Maximum Design Pressures
—59.75 psf
—101 psf,
Maximum Screw Spacing
169! O.C.
6.75" o.c.-
1. Extrapolation shall not be allowed
I
I
I
MIAMI-DARE COUNTY
,TIC 1
�I
i
I
I
NOA No.: 14-0416.01
Expiration Date: 01/09/19
Approval Date:. 06/05/14 .
Page 3 of 5
I
I
SYSTEM LIMITATIONS
1. Ii Fire classification is not part of this acceptance; refer to a current Approved Roofing.Materials Directory for fire
ratings .of this product.
2. ' The maximumdesigned pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters,
and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones (i:e. perimeters, extended corners and corners).
3. 1 Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in
i
Roofing Application: Standard RAS 133.
4. All .panels shall be permanently labeled, with the manufacturer's name and/or. logo, city, state, and the following
i statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade. County Product Control
i Seal as seen -.below.,.- All clips shall be .permanently labeled with. the manufacturer's name and/or logo, and/or
'I model.
MIAMI-DADE COUNTY
I
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code ,and
Rule 61G20-3 of the Florida Administrative Code.
6. Panels may be shop or jobsite roll formed with machine model #5521005 or 7031100 from:PAC Contractors
Association.
I
i
I
1
i
I
I
i
i
NOA No.: 14-0416.01
MWJ41-DADE COOW Expiration Date: 01/09/19
Approval Date: 06/05/14
Page 4 of 5
i
PROFILE DRAWINGS
16"
Fastener Relief, Stiffening Ribs and Striations are Optional
Field Condition
0
EDGE-LOC 1.0 PANEL SYSTEM
END OF THIS ACCEPTANCE
NOA No.: 14-0416.01
Expiration Date: 01/09/19
Approval Date: 06/05/14
Page 5 of 5