HomeMy WebLinkAboutREVIEW COMMENTSig & Development Services & Code Regulation Division 300 Virginia Avenue rrt Pierce, FL. 34982 !)462-2172 Fax:(772)462.6"3 Address: 18700 Mach One Dr City / State / Zip: Port St Lucie, FI 34987 Parcel #: 3215-801-0011-000/8 Zoning: i AG-5 REVIEW COMMENTS 1 Ownei(s): James D Busby li / Kristina A Busby Jurisdiction: SAINT LUCIE COUNTY Lot#: Permit Number: 1810-0386 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) Contractor Name: Craig Helseth Business Name: Craig Helseth Construction, Inc Business Addr: 18602 Mach One Dr City / State / Zip: Fort Pierce, FI 34987-3234 Block: Automatic Sprinkler System? No Fax Number: 772-464-8425 Email: Craig.Helseth@Yahoo.Com Review Tvge I Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Audrey Humphrey 10/17/2018 10/17/2018 Comment: ELECTRICAL SUB IS ON HOLD AND NEEDS TO UPDATE WITH CONTRACTOR'S LICENSING. 10/17/2018 Comment: CUSTOMER SENT TO ERD WITH VEG REMOVAL PERMIT. I ENVIRONMENTAL REVIEW PENDING Lynn Swartzei 10/23/2018 Comment: FRONT COUNTER REVIEW COMPLETE Audrey Humphrey 10/17/2018 10/17/2018 10/17/2018 Comment: PLANS EXAMINER REVIEW PLETE Joseph Fersch 10/29/2018 Comment: 7ROVIDENOAS / PRODUCT APPROVALS FOR THE CEMENT FIBER BOARD TO BE USED. ALL DOCUMENTS 10/29/2018 MITTED FOR REVIEW MUST BE IN DUPLICATE. AS PER CHAPTER 1, SECTION 107 SUBSECTION 107.1 1 O HE 2014 FLORIDA BUILDING CODE. 10/29/21018 Comment: ROVIDE DETAIL SHOWING MATERIAL AND METHOD OF ATTACHMENT OF THE FIBER SIDING ATTACHMENT CMU AND WOOD. 10/29/21018 Comment: FURNISH 2 SETS OF ENGINEERED TRUSS DRAWINGS WITH THE (ENEGINEER OF RECORDS APPOVAL STAMP WITH ORIGNAL SIGNITURE) 107.2.1 OF THE 2017 FLORIDA BUILDING CODE SIXTH EDTITION. Comment FU NISH 2 SETS OF PLANS WITH THE ENEGINEER / ARCHITECH OF RECORD ORIGNAL SIGNITURE) 10/29/21018 1 .2.1 OF THE 2017 FLORIDA BUILDING CODE SIXTH EDTITION. Comment: ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING THE 10/291J 18 SQUARE FOOT INFORMATION. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE SIXTH EDTITION 10/29/2018 Comment: SHOW CERAMIC TILE IS IN ACCORDANCE WITH 702.4 OF THE 2017 FLORIDA RESIDENTIAL CODE SIXTH I EDITION Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. ,34982 Phone:(772)462-A72 Fax:(772)462.6443 10/29/2018 Comment: 10/29/2018 Comment: Comment: 10/29/2018 10/29/2018 Comment: Comment: 10/29/2018 Comment: 10/2912018 ZONING REVIEW Comment: REVIEW COMMENTS Page SHOW GYPSUM BOARD MATERIALS ARE IN ACCORDANCE WITH 702.3.1 OF THE 2017 FLORIDA RESIDENTIAL CODE PROVIDE DETAIL FOR GYPSUM IN ACCORDANCE WITH R702.3.5 APPLICATION SHOW R703.1.2.1 WIND RESISTANCE OF SOFFITS. SHOW/IDENTIFY SOFFITS AND THEIR ATTACHMENTS SHALL BE CAPABLE OF RESISTING WIND LOADS SPECIFIED IN TABLES R301.2(2) AND R301.2(3) FOR WALLS USING AN EFFECTIVE WIND AREA OF 10 SQUARE FEET SHOW R309.4 AUTOMATIC GARAGE DOOR OPENERS. AUTOMATIC GARAGE DOOR OPENERS, IF j PROVIDED, SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 325. SHOW R903.2 ROOF FLASHING. SHOW/IDENTIFY FLASHINGS SHALL BE USED TO SEAL ROOFING SYSTEMS, WHERE THE SYSTEM IS INTERRUPTED OR TERMINATED AND SHALL BE INSTALLED IN A' MANNER THAT PREVENTS MOISTURE FROM ENTERING THE WALL AND ROOF THROUGH JOINTS IN COPINGS, THROUGH MOISTURE PERMEABLE MATERIALS AND AT INTERSECTIONS WITH PARAPET'WALLS AND OTHER PENETRATIONS THROUGH THE ROOF PLANE. SHOW R903.2.1 ROOF FLASHING LOCATIONS. SHOW/IDENTIFY FLASHINGS SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR DIRECTION AND AROUND ROOF OPENINGS. WHERE FLASHING IS OF METAL, THE METAL SHALL BE CORROSION RESISTANT WITH A THICKNESS OF NOT LESS THAN PROVIDED IN TABLE R903.2.1 OR IN COMPLIANCE WITH RAS 111. 1 COMPLETE Lydia Galbraith 10/24/2018 10/24/2018 10/24/2018