HomeMy WebLinkAboutBLOWER DOOR TEST CERTIFICATEPlanning & Development Services
Building & Code Regulation Division
i 2300 Virginia Ave, Rm 201
° Fort Pierce, FL 34982
Phone: 772-462-2165 Faw 772-462-6443
Date., 1 I' I-� LA
D
Jobs Address:
Construction:
BLOWER DOOR TEST FORM
.House infiltration Testy Certification
Prescriptive and Performance Method
2 S MA
FUe COPY
i.C6'tyev
peK Sti tau e � u R�er�
U Isc
Permit #:
1
(f -1 New construction —
i l4. P1erce-1 FL 3'f4 tf4 yllL
( Existing —After Addition
House Infiltration Vest Results SLC Climate Zone 2
CFM (50) = Z -1 ( Test Date:
Volume'= Z2310
ACH (50) = CFM (50) a 60 / Volume = Mechanical Ventilation required less than 3 ACH
Passing iesults must be & ACH (50) or less '(54pass ( ) Fall
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testina Comoanv
Company Name: Pro -Duct Services
Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate Zone 2.
A
Signature:1
Printed Name: Martin Klein
License/Certification #: 5061633
BUILDING PERFORMANCE INSTITUTE, INC.
107 Hermes Road, Suite 210
Malta, NY 12020
-
(877) 274-1274
—
www.bpi.org-'
_-
. B
Martin Klein
%. BPIID#:50616?^
CERTIFIED PROFESSIONAL
t eM (SEE REVERSE SIDE FOR DESIGNATIONS
AND EXPIRATION DATES)