HomeMy WebLinkAboutREVISION - PRODUCT APPROVAL - 5 V CRIMP ALUMINUM ROOFFILE COPY
�
•` - - " 2160 SW Poma: Drive
Palm City, FL 34990
A772)872-8034
Compliant with Florida Building Code 2017 (6th ed.) SCANNED
Compliant With Florida Product Approval Rule # 61G20-3 St LucBr
CoUnfy
Compliant: Keystone Certifications
I
Product: 5 V Crimp 0.032" Aluminum Roof Panel FBC Sec. 1507.4.2
Yield strength: 0.032" Aluminum Min.; Attached to min.15/32" plywood or
Wood Deck w/min 0.42 specific gravity with screws. 21" Coverage (Max.)
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1: #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or
5/8" min embedment into wood plank. (*or of sufficient length to meet requirements)
Underlayment: To be compliant with FBC Sec. 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
,I
Install Details: Table A Allowable Loads
METHOD 1
DESIGN PRESSURE*
- ° -168.5 PSF '
-
ROW SPACING
- .10" O.C.
FASTENER
SPACING (ALONG ROWS)
Reference Data: ARCHITECTURAL TESTING, INC TST iD#:.1527�7
UL 580-06
& 1897-041 Test Report D5893.04-450-18 10/24/14
*EQU
VALENCY: UL 1897-041 is equivalent to test standard UL 1897,12.
*DESIGNPRESSURE 44ARGM OF SAFETY2:1
Certificate
Locke Bowden,
of Independence: n
P.E. does not have, not will acquire a financial interest in any company manufactuking or distributing products
under this
Locke Bowden,
evaluation.
P.E. is not owned, operated, or controlled by,acturec, or distributing products under this
report.
,.
a.
• i
MoVED
DVQ�►�9ING I Al1@11iiITTA�L REvlCvr
TED
REVISE AND RESUBMIT ❑ REJECTED
SUBMITTAL WAS REVIEWED FOR DESIGN CONFORMITYAND
GEEAL ONNYR THEOCONTIRACTOR SANCE TO ORES CT D
ONSIOBLE EFOR
FOR TOLIERANCE, CLEARANCE, QUANTVIEIITIES, FABRICATION
PROCESSES AND TECHNIQUES OFTHERNSRADESIAND
co R TIO OF HIS WORK WIT OCU NTS
FULLC CEIMTHCON
TRA
Date:
Architectonic
34950
Fort Pierce,FL
Limitations
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6thled., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing compliant w/FBC 2017 6th ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for Structural
7. This report does not imply warranty, installation, recommended product use outside of this report.
FL17022.2 5V Crimp (0.032" Alum), 21" Wide Roof Panel -Details
Fastener #I9 x 1-12' Minimum
uo,.lAbeh, 11m,1 Mkvvi cYa.M r— 5-V Crimp Roof Panel
Deck -15/32' or greater Plywood, or
- V1bod plank
21"
10:5"
3/8"
v OPTIONAL STRIATIONS
Panel Profile
Nominal 10.5" o.c. I Nominal 10.5" o.c.
Panel Overlap -
Isometric View
Fastener
#9 x 1-1/5" Min.
Hex Washer Head Screw
Spaced 10.5" o.c. across the Panel
Deck:
=15/32" or greater Plywood, or
- Wood plank
Loading.