Loading...
HomeMy WebLinkAboutREVISION - PRODUCT APPROVAL - 5 V CRIMP ALUMINUM ROOFFILE COPY � •` - - " 2160 SW Poma: Drive Palm City, FL 34990 A772)872-8034 Compliant with Florida Building Code 2017 (6th ed.) SCANNED Compliant With Florida Product Approval Rule # 61G20-3 St LucBr CoUnfy Compliant: Keystone Certifications I Product: 5 V Crimp 0.032" Aluminum Roof Panel FBC Sec. 1507.4.2 Yield strength: 0.032" Aluminum Min.; Attached to min.15/32" plywood or Wood Deck w/min 0.42 specific gravity with screws. 21" Coverage (Max.) Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1: #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" min embedment into wood plank. (*or of sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. ,I Install Details: Table A Allowable Loads METHOD 1 DESIGN PRESSURE* - ° -168.5 PSF ' - ROW SPACING - .10" O.C. FASTENER SPACING (ALONG ROWS) Reference Data: ARCHITECTURAL TESTING, INC TST iD#:.1527�7 UL 580-06 & 1897-041 Test Report D5893.04-450-18 10/24/14 *EQU VALENCY: UL 1897-041 is equivalent to test standard UL 1897,12. *DESIGNPRESSURE 44ARGM OF SAFETY2:1 Certificate Locke Bowden, of Independence: n P.E. does not have, not will acquire a financial interest in any company manufactuking or distributing products under this Locke Bowden, evaluation. P.E. is not owned, operated, or controlled by,acturec, or distributing products under this report. ,. a. • i MoVED DVQ�►�9ING I Al1@11iiITTA�L REvlCvr TED REVISE AND RESUBMIT ❑ REJECTED SUBMITTAL WAS REVIEWED FOR DESIGN CONFORMITYAND GEEAL ONNYR THEOCONTIRACTOR SANCE TO ORES CT D ONSIOBLE EFOR FOR TOLIERANCE, CLEARANCE, QUANTVIEIITIES, FABRICATION PROCESSES AND TECHNIQUES OFTHERNSRADESIAND co R TIO OF HIS WORK WIT OCU NTS FULLC CEIMTHCON TRA Date: Architectonic 34950 Fort Pierce,FL Limitations 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6thled., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing compliant w/FBC 2017 6th ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for Structural 7. This report does not imply warranty, installation, recommended product use outside of this report. FL17022.2 5V Crimp (0.032" Alum), 21" Wide Roof Panel -Details Fastener #I9 x 1-12' Minimum uo,.lAbeh, 1­1m,1 Mkvvi cYa.M r— 5-V Crimp Roof Panel Deck -15/32' or greater Plywood, or - V1bod plank 21" 10:5" 3/8" v OPTIONAL STRIATIONS Panel Profile Nominal 10.5" o.c. I Nominal 10.5" o.c. Panel Overlap - Isometric View Fastener #9 x 1-1/5" Min. Hex Washer Head Screw Spaced 10.5" o.c. across the Panel Deck: =15/32" or greater Plywood, or - Wood plank Loading.