Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE -2M R405-2017 )RI®A ENERGY EFFIC5ENCY CODE FOR BUDDING CONSTRUCTION lorida Department of Business and Professional Regulation - Residential Performance Method Name: GAMBINA RESIDENCE CALUMET COURT ate, "Lip: PORT ST LUCIE , FL, Location: FL, Fort Pierce Builder Name: Permit Office: SCANNED Permit Number: �Y L/ Jurisdiction: County:: St. Lucie (Florida Climate Zone §t Lucie County 1. New construction or existing New (From Plans) 9. Wall Types (6310.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 3530.00 ft2 3. Number of units, if multiple family 1 b. Frame- Wood, Exterior R=19.0 2240.00 ft2 4. Number of Bedrooms 5 c. Frame - Wood, Exterior d. N/A R=11.0 540.00 fF R= ft2 5. Is tf1is a worst case? No 10. Ceiling Types (6924.0 sgft.) Insulation Area 6. Coriditioned floor area above grade (ft2) 6924 a. Roof Deck (Unvented) b. N/A R=20.0 6924.00 ft2 R= ft2 Coniditioned floor area below grade (ft2) 0 c. N/A R= W 7. Windows(953.7 sgft.) Description Area 11. Ducts a. Sup: Attic, Rat Attic, AH: AHU 1 R ft2 6 140 a. U-Factor: Sgl, U=0.65 953.67 ft2 b. Sup: Attic, Ret: Attic, AH: AHU 3 6 250 �HGC: SHGC=0.25 c. Sup: Attic, Ret: Attic, AH: AHU 3 6 160 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: E c. d-Factor: N/A a. Central Unit b. Central Unit 24.0 SEER:16.00 58.0 SEER:16.00 ft2 SHGC: i c. Central Unit 36.2 SEER:16.00 d: Ui Factor: N/A ft2 13. Heating systems I kBtu/hr Efficiency SHGC: a. Electric Strip Heat 17.0 COP:1.00 l AreaWeighted Average Overhang Depth: 1I b. Electric Strip Heat c. Electric Strip Heat 34.0 COP:1.00 1.500 ft. Area W 27.0 COPA.00 eighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (6924.0 sgft.) Insulation Area a. Slab -On -Grade Edge a. Electric Cap: 50 gallons EF: 0.980 Insulation R=0.0 4784.00 ft2 b. Raised Floor b. Conservation features. R=19.0 2140.00 ft 2 None c. N/A _ R= ft2 � i 15. Credits None Total Proposed Modified Loads: 183.13 Glass/Floor Area: 0.138 Total Baseline _oads: 203.36 I hereb, certify that the plans and specifications covered by Review of the plans and ST,q?� j this ca cula,ion are in compliance with the Florida Energy specifications covered by this OF'ME ti, Code. calculation indicates compliancePREP D Ba4g(J With the Florida Energy Code. Ii :..5.r DATE: DATE: Before construction is completed j this building will be inspected for ..... -' ( compliance with Section 553.908 j I hereby •• with th ceiify that this building, as designed, is in compliance Florida 1 Florida Statutes. �;G i Energy C e. OS OD W OWNER/?,�jENT• I' BUILDING OFFICIAL: DATE: !.; DATE: - Cor4liar ce requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified fasctoty-sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection ;,'heckllst in accordance with R402.4.1.1 and this project requires an env lobe leakage test report with envelope leakage no greater than 7.Q0 ACH50 (R402.4.1.2). 3/7/2018 9:21 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 i FORM K405-2017 PROJECT Title: GAMBINA RESIDENCE Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 6924 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # ofiUnits: 1 Worst Case: No PlatBook: Builder Name: Permit Office: Rotate Angle: 0 Street: CALUMET COURT Jurisdiction: Cross Ventilation: County: St. Lucie Family Type: Single-family Whole House Fan: City, State, Zip: PORT ST LUCIE , New/Existing: New (From Plans) FL , { Comment: I ^C(feOMiWTE Design Location _ Design Temp Int Design Temp Heating Design Daily Temp TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce I FL VERO_BEACH MUNI 39 90 _ 70 75 299 62 Low i BLOCKS Number Name Area Volume ? Blockl 1425 14250 �I 2I Block2 3359 33590 3 Black3 2140 19260 SPACES 'L Number I Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated ? AHU 1 1425 14250 No 0 1 1 Yes Yes Yes 2 AHU 2 3359 33590 Yes 0 1 1 Yes Yes Yes I; 3 AHU 3 2140 19260 No 0 - - 3 1 Yes Yes Yes �i _ F�,.�D�D�w - - \ # F Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet I� 'I Slab -On -Grade Edge Insulation I AHU? 124 ft 0 1425 ftz ---- 1 0 0 2 Slab -On -Grade Edge Insulation �i AHU 2 209 ft 0 3359 f? ---- 1 0 0 Ii 3 Raised Floor AHU 3 -_ 2140 ft2 19 1 0 0 ROOF Type Roof Gable Roof Solar SA Emitt Emitt Deck Pitch Materials Area Area Color Absor. Tested Tested Insul. (deg) I -lip Barrel tile 7744 ft2 0 ft'- Medium 0.6 No 0.9 No 20 26.6 rrsTi TOC t" Type Ventilation Vent Ratio (1 in) Area RBS IRCC I Full attic Unvented 0 6924 ft2 - N N 3/7/2018 9:21 AM EnergyGauge : USA - FlaRes2017 Section R40.5.4.1 Compliant Software Page 2 of 5 FORMI R405-2017 CELONG \ # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) AHU 1 20 Blown 1425 ft2 0.11 Wood 2 Under Attic (Unvented) AHU 2 20 Blown 3359 ft2 0.11 Wood i 3 Under Attic (Unvented) AHU 3 20 Blown 2140 ft2 0.11 Wood WALLS ATindjacent 1 T�fpeSpace Cavity Width - Height Sheathing Framing Solar Below - 1 N Exterior Concrete Block - Ext Insul AHU 1 4.09999 31 10 310.0 ft2 0 o 0 0.600000 0 _ 2 E I I Exterior Concrete Block - Ext Insul AHU 1 4.09999 18 10 1802 .0 ft 0 0 0.600000 0 - 3 S Exterior Concrete Block - Ext Insul AHU 1 4.09999 31 10 310.0 ft2 0 0 0.600000 0 - 4 W Exterior Concrete Block - Ext Insul AHU 1 4.09999 54 10 540.0 ft2 0 0 0.600000 0 -5 N Exterior Concrete Block - Ext Insul AHU 2 4.09999 80 10 800.0 ft2 0 0 0.600000 0 E Exterior Concrete Block - Ext Insul AHU 2 4.09999 48 ' 10 480.0 ft2 0 0 0.600000 0 li 7 S Exterior Concrete Block - Ext Insul AHU 2 4.09999 57 10 570.0 ft2 0 0 0.600000 0 I• _ 8 VJ Exterior Concrete Block - Ext Insui AHU 2 4.09999 34 10 340.0 ft2 0 0 0.600000 0 _ 9 N Exterior Frame - Wood AHU 3 19 70 9 4 653.3 ft2 0 0 0.600000 0 !� -10 E Exterior Frame - Wood AHU 3 19 50 9 4 466.7ft 2 0 0 0.600000 0 t -15 Exterior Frame - Wood AHU 3 19 70 9 4 653.3 ft2 0 0 0.600000 0 ' -12 V/ Exterior Frame - Wood AHU 3 19 50 9 4 466.7 ft2 0 0 0.600000 0 13 E i; Exterior Frame - Wood AHU �i 11 31 10 310.0 ft2 0 0 0.600000 0 _ 1 S !j Exterior Frame - Wood AHU 1 11 23 10 230.0 ft2 0 0 0.600000 0 I' WONDOWS - Orientation shown is the entered, Proposed orientation. II, Wall Overhang l; 1� # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening �i 1 N 1 Metal Low-E Single Yes 0.65 0.25 N 54.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 r 2 N 1 Metal Low-E Single 1'es 0.65 0.25 N 12.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 f 3 E 2 Metal Low E Single Yes 0.65 0.26 N 40.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 4 E 2 Metal Low-E Single Yes 0.65 0.25 N 10.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 5 S 3 Metal Low-E Single Yes 0.65 0.25 N 45.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 6 S 3 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 7 W i, 4 Metal Low E Single Yes 0.66 0.25 N 8.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 8 W i' 4 Metal Low-E Single Yes 0.65 0.25 N 21>.0 fie 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 i.. 9 W 4 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 10 N 5 Metal Low-E Single Yes 0.65 0.26 N 48.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 } 11 N 5 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 12 N i 5 Meta! Low-E Single Yes 0.65 0.25 N 8.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 13 N �1 5 Metal Low-E Single Yes 0.65 0.26 N 32.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 14 N 5 Meta! Low-E Single Yes 0.65 0.25 N 42.7 ft2 1 it 6 in 1 ft 4 in Drapes/blinds Exterior 5 15 N 5 Metal Low-E Single Yes 0.65 0.26 N 10.7 ft2 1 ft o^ in 1 ft 4 in Drapes/blinds Exterior 5 Ij 16 N 5 Mlemi Low-E Single Yes 0.65 0.25 !V 20.0 ft2 1 ft6 in 1 ft 4 in Drapes/blinds Exterior 5 17 N 5 Metal Low-E Single Yes 0.65 0.25 iI 8.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 18 N 5 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 19 iV 5 Metal Low-t Single Yes 0.65 0.2; Iv 13.0 ft2 1 ft 6 in 1 fi 4 in Drapes/blinds Exterior 5 3/7/2018 9:21 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM! R405-2017 WOMDOWS Orientation shown is the entered, Proposed orientation. Wall Vi�... ! Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 20 N 5 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 21 S 7 Metal Low-E Single Yes 0.66 0.25 N 24.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 22 S 7 Metal Low-E Single Yes 0.65 0.25 N 36.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 23 S 7 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 I I 24 S 7 Metal Low-E Single Yes 0.65 0.25 fV 8.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 25 S 7 Metal Low-E Single Yes 0.65 0.25 N 4.0 ft' 1 ft6 in 1 ft 4 in Drapes/blinds Exterior 5 26 S 7 Metal Low-E Single Yes 0.65 0.25 N 24.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 27 W 8 Metal Low-E Single Yes 0.85 0.25 N 80.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 I'. I' 28 W 8 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 !i 29 N 5 Metal Low-E Single Yes 0.65 0.25 N 90.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 I! !� ! 30 I N 5 Metal Low-E Single Yes 0.65 0.26 N 30.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 31 32 S 7 Metal Low-E Single Yes 0.65 0.25 N 30.0 ftz 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 `` N 9 Metal Low-E Single Yes 0.66 0.25 N 15.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 I 33 N 9 Nletai Low-E Single Yes 0.65 0.25 N 20.0 fizz 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 34 S 11 Metai Low-E Single Yes 0.65 0.25 N 16.0 ft' 1 ft 6 in 1 f:4 in Drapes/blinds Exterior 5 35 S 11 ivleml Low-E Single Yes 0.65 0.26 N 16.0 ftz 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 li 36 I S 11 Metal Low-E Single Yes 0.65 0.25 N 6.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 37 S 11 Metal Low-E Single Yes 0.65 0.25 N 36.0 ftz 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 11 38 E 10 Metal Low-E Single Yes 0.65 0.26 N 21.3 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE \ # Floor Area ^Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation I 1150 ftz 1150 ftz 54 ft loft 11 # Scope Method; SLA CFM 5G EL;; EgLA ACH ACH 50 1 WI olehouse Proposed ACH(50) .000431 7828.3 429.76 808.24 .3147 7 HEATNG S} S T EM _ \ # System Type Subtype Efficiency _ Capacity Block Ducts ! 1 Electric Strip Haat/ None COPA 17 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COP:1 34 kBtu/hr 2 sys#2 3 Electric Strip Heat/ None COP:1 27 kBtu/hr 3 sys#3 3/7/2018 9:21 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R4O5_9017 i iCOOUNG SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None SEER: 16 24 kBtu/hr 720 cfm 0.8 1 sys#1 2 Central Unit/ None SEER: 16 58 kBtu/hr 1740 cfm 0.8 2 sys#2 3 Central Unit/ I None SEER: 16 36.2 kBtu/hr 1086 cfm 0.8 3 sys0 HOT WATER SYSTEM \ # System Type SubType Location EF Cap Use SetPnt Conservation i Electric None Garage 0.98 50 gal 80 gal 120 deg None SOLAR HOT WATER SYSTEM ` FSEC Collector Storage ' Cert # Company Name I�None System Model # Collector Model # Area Volume FEF None i ft2 DUCTS Supply-- — Return -- Air CFM 25 CFM25 HVAC # T V Location R-Value Area �� Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool Attic 6 140 ft2 Attic 14 ftz Default Leakage AHU 1 (Default) c(Default) c 1 1 2 Attic 6 250 ftZ Attic 25 rtZ Default Leakage AHU 3 (Default) c(Default) c 2 2 3 Attic 6 160 `rig Attic 16 ft2 Default Leakage g AHU 3 (Default) c(Default) c 3 3 I. TERAPEkkTURES Pro ramable Thermostat: None j g s Ceiling Fans: Cooling ]Jan [ ]Feb [ ] Mar Healing ,. Jan [[Xj] Feb Mar j j Apr jjj j j Apr j l May [:'.j Jun jX] Jul j May j 1 Jun I' ] Jul Aug Au �Xj X Sep j j Oct 4 S [ ]Oct j j Nov jXj Nov j j Dec [Xj Dec [[XXII Venting ( Jan Feb Mar [X] Apr [ ] May (11 Jun ] Jul Aug[ Sep Oct [X] Nov [ j Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 '4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling,(WEH) AM 78 78 78 78 78 78 78 76 78 78 78 78 PM 78 Haafinn /Il1/rl1 nn.i 78 78 78 78 78 78 78 78 78 78 78 PM 68 68 i. 1. Heating (WEH) AM 88 68 PU!! 68 68 1 3/7/2018 9:21 AM i 68 68 68 68 68 58 68 68 68 bb bo bt3 ua 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 EnergyGaugefl USA - FlaRes2017 Section R405.4.1 Compliant Software 68 68 68 68 68 68 68 68 Page 5 of 5 201 i d a gum BARRIER AMD uHSULATIOH INSPECTION CUMPONENT CRITERIA TABLE 402.4A.1 AIR BARRIER AHD INSULATION ENSPECTi IOH COMPONENT CRITERIA Project Name: GAMBINA. RESIDENCE Builder Name: 1 P 1Ce J9Xdv5 Street: CALUMET COURT Permit Office: City, Owner: State, Zip: PORT ST LUCIE , FL, Permit Number. f8) 0 ,03Qq Design Jurisdiction: Location: FL, Fait Pierce co, VMp<JWEN tl A' d\ SARMER CMI II IE MA NJVJJLATION QIt'1STALLA1 OOH CROTERIA 1 General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous barrier. j requirements air not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceili Ig/attic The air barrier in any dropped ceiling/soiff it small be aligned with the ; The insulation in any dropped ceiling/soffit + insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to shall be aligned with the air barrier. unconditioned attic spaces shall be sealed. r Walls The junction of the foundation and sill plate small be sealed. Cavities within corners and headers of frame walls shall The junction. of the top plate and the top of exterior walls shall be sealed. i be insulated by completely filling the cavity with a Knee walls shalt be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windt m skylights The space between window/doorjambs andframing, and al u uuU,s -..,....,:.,...y �..� 1 Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors (including The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to above -garage maintain permanent contact with the underside of and cantilevered floors) ; subfloor decking,or floor framing caul g cavity insulation shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom i to the top of al! perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a . Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace walls. Shafts, penetrations { Duct shafts, utility penetrations, and flue shafts opening to exterior I or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrov✓ csvit!as cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. = �•��� �+-�•�••�++ n++ L) s,+eu ue prowuea oeaFieen the garage and conditioned spaces. 1 Recessed lighting i Recessed Gght fixtures Installed in � the building thermal envelope shall Recessed light fixtures installed in the building : be sealed to the drywall. � thermal envelope shall be air tight and iC rated. Plun»irg and wiring Eatt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall --- extend behind piping and wiring. Shower:!--_1 ' The air aarr!er insialtad at rxter for walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on a tenor wall rubs shaf separate them from the showers and tubs. insulated. Electricaliphone box on The air barrier shall be installed behind electrical or communication exterioir wai,s boxes or air -sealed boxes shall be installed. HVAC ragistar boots HV AC register boots that penetrate building thermal envelope shall be *hame S:.ih-`'^^. Or di f✓:'i`•I!. Sealed to . ico Corce c When ra:lnir ed lobe sealed, concealed fire sprinklers shall orgy be sealed spninla= tr a m .... r hat;z racomma+�ded he rn ""•� t by t arufactiare:. Caulking or other Iv adhesive sealants shall not he ussi to fill voids betwesr, fire sprinkler _ •• _cove!" p!^ateS and Y•✓ails Or Celli!"I'�S. a. ]n ad•i itiar , inspection of log walls shall ba !n accordance with the of ICC-500. 3/7/2018 ,;:?1 AIVI provisions EnergyGaugew USA - rlaRes20'17 FBC 5th Edition (2017) Compliant Software Page 1 of 1