HomeMy WebLinkAboutENERGY EFFICIENCY CODE -2M R405-2017
)RI®A ENERGY EFFIC5ENCY CODE FOR BUDDING CONSTRUCTION
lorida Department of Business and Professional Regulation - Residential Performance Method
Name: GAMBINA RESIDENCE
CALUMET COURT
ate, "Lip: PORT ST LUCIE , FL,
Location: FL, Fort Pierce
Builder Name:
Permit Office: SCANNED
Permit Number: �Y L/
Jurisdiction:
County:: St. Lucie (Florida Climate Zone §t Lucie County
1. New
construction or existing New (From Plans)
9. Wall Types (6310.0 sgft.)
Insulation Area
2. Single
family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 3530.00 ft2
3. Number
of units, if multiple family 1
b. Frame- Wood, Exterior
R=19.0 2240.00 ft2
4. Number
of Bedrooms 5
c. Frame - Wood, Exterior
d. N/A
R=11.0 540.00 fF
R= ft2
5. Is tf1is
a worst case? No
10. Ceiling Types (6924.0 sgft.)
Insulation Area
6. Coriditioned floor area above grade (ft2) 6924
a. Roof Deck (Unvented)
b. N/A
R=20.0 6924.00 ft2
R= ft2
Coniditioned floor area below grade (ft2) 0
c. N/A
R= W
7. Windows(953.7 sgft.) Description Area
11. Ducts
a. Sup: Attic, Rat Attic, AH: AHU 1
R ft2
6 140
a. U-Factor: Sgl, U=0.65 953.67 ft2
b. Sup: Attic, Ret: Attic, AH: AHU 3
6 250
�HGC: SHGC=0.25
c. Sup: Attic, Ret: Attic, AH: AHU 3
6 160
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
E c. d-Factor: N/A
a. Central Unit
b. Central Unit
24.0 SEER:16.00
58.0 SEER:16.00
ft2
SHGC:
i c. Central Unit
36.2 SEER:16.00
d: Ui Factor: N/A ft2
13. Heating systems
I
kBtu/hr Efficiency
SHGC:
a. Electric Strip Heat
17.0 COP:1.00
l
AreaWeighted Average Overhang Depth:
1I b. Electric Strip Heat
c. Electric Strip Heat
34.0 COP:1.00
1.500 ft.
Area W
27.0 COPA.00
eighted Average SHGC: 0.250
14. Hot water systems
8. Floor Types (6924.0 sgft.) Insulation Area
a. Slab -On -Grade Edge
a. Electric
Cap: 50 gallons
EF: 0.980
Insulation R=0.0 4784.00 ft2
b. Raised Floor
b. Conservation features.
R=19.0 2140.00 ft 2
None
c. N/A _ R= ft2
�
i 15. Credits
None
Total Proposed Modified Loads: 183.13
Glass/Floor Area: 0.138
Total Baseline
_oads: 203.36
I hereb, certify that the plans and specifications covered by
Review of the plans and
ST,q?�
j this ca
cula,ion are in compliance with the Florida Energy
specifications covered by this
OF'ME
ti,
Code.
calculation indicates compliancePREP
D Ba4g(J
With the Florida Energy Code.
Ii
:..5.r
DATE:
DATE:
Before construction is completed
j this building will be inspected for
.....
-' (
compliance with Section 553.908
j I hereby
•• with th
ceiify that this building, as designed, is in compliance
Florida
1 Florida Statutes.
�;G
i
Energy C e.
OS
OD W
OWNER/?,�jENT•
I' BUILDING OFFICIAL:
DATE:
!.; DATE:
- Cor4liar ce requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified fasctoty-sealed in accordance with R403.3.2.1.
Compliance requires an Air Barrier and Insulation Inspection ;,'heckllst in accordance with R402.4.1.1 and this project requires
an env lobe leakage test report with envelope leakage no greater than 7.Q0 ACH50 (R402.4.1.2).
3/7/2018 9:21 AM
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 1 of 5
i
FORM K405-2017
PROJECT
Title:
GAMBINA RESIDENCE Bedrooms: 5
Address Type:
Street Address
Building Type:
User
Conditioned Area: 6924
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# ofiUnits:
1
Worst Case: No
PlatBook:
Builder Name:
Permit Office:
Rotate Angle: 0
Street:
CALUMET COURT
Jurisdiction:
Cross Ventilation:
County:
St. Lucie
Family Type:
Single-family
Whole House Fan:
City, State, Zip:
PORT ST LUCIE
,
New/Existing:
New (From Plans)
FL ,
{ Comment:
I
^C(feOMiWTE
Design
Location
_ Design Temp
Int Design Temp Heating
Design Daily Temp
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce
I
FL VERO_BEACH MUNI 39 90
_
70
75 299
62
Low
i
BLOCKS
Number
Name
Area Volume
?
Blockl
1425 14250
�I 2I
Block2
3359 33590
3
Black3
2140 19260
SPACES
'L Number
I
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
?
AHU 1
1425 14250 No 0
1
1 Yes
Yes
Yes
2
AHU 2
3359 33590 Yes 0
1
1 Yes
Yes
Yes
I; 3
AHU 3
2140 19260 No 0
- -
3
1 Yes
Yes
Yes
�i
_
F�,.�D�D�w
-
-
\ #
F
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
I� 'I Slab -On -Grade Edge Insulation
I
AHU? 124 ft 0
1425 ftz
----
1 0
0
2 Slab -On -Grade Edge Insulation
�i
AHU 2 209 ft 0
3359 f?
----
1 0
0
Ii 3 Raised Floor
AHU 3 -_
2140 ft2
19
1 0
0
ROOF
Type
Roof Gable Roof
Solar
SA Emitt
Emitt Deck
Pitch
Materials Area Area Color
Absor.
Tested
Tested Insul.
(deg)
I -lip
Barrel tile 7744 ft2 0 ft'- Medium
0.6
No 0.9
No 20
26.6
rrsTi TOC
t"
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
I
Full attic
Unvented 0 6924 ft2
-
N N
3/7/2018 9:21 AM EnergyGauge : USA - FlaRes2017 Section R40.5.4.1 Compliant Software Page 2 of 5
FORMI R405-2017
CELONG
\ #
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented)
AHU 1
20
Blown
1425 ft2
0.11 Wood
2
Under Attic (Unvented)
AHU 2
20
Blown
3359 ft2
0.11
Wood
i 3
Under Attic (Unvented)
AHU 3
20
Blown
2140 ft2
0.11 Wood
WALLS
ATindjacent 1 T�fpeSpace
Cavity Width
-
Height
Sheathing Framing Solar Below
- 1 N
Exterior Concrete Block - Ext Insul
AHU 1
4.09999 31
10
310.0 ft2
0
o
0 0.600000 0
_ 2 E
I I
Exterior Concrete Block - Ext Insul
AHU 1
4.09999 18
10
1802
.0 ft
0
0 0.600000 0
- 3 S
Exterior Concrete Block - Ext Insul
AHU 1
4.09999 31
10
310.0 ft2
0
0 0.600000 0
- 4 W
Exterior Concrete Block - Ext Insul
AHU 1
4.09999 54
10
540.0 ft2
0
0 0.600000 0
-5 N
Exterior Concrete Block - Ext Insul
AHU 2
4.09999 80
10
800.0 ft2
0
0 0.600000 0
E
Exterior Concrete Block - Ext Insul
AHU 2
4.09999 48 '
10
480.0 ft2
0
0 0.600000 0
li 7 S
Exterior Concrete Block - Ext Insul
AHU 2
4.09999 57
10
570.0 ft2
0
0 0.600000 0
I• _ 8 VJ
Exterior Concrete Block - Ext Insui
AHU 2
4.09999 34
10
340.0 ft2
0
0 0.600000 0
_ 9 N
Exterior Frame - Wood
AHU 3
19 70
9 4
653.3 ft2
0
0 0.600000 0
!� -10 E
Exterior Frame - Wood
AHU 3
19 50
9 4
466.7ft 2
0
0 0.600000 0
t -15
Exterior Frame - Wood
AHU 3
19 70
9 4
653.3 ft2
0
0 0.600000 0
' -12 V/
Exterior Frame - Wood
AHU 3
19 50
9 4
466.7 ft2
0
0 0.600000 0
13 E
i;
Exterior Frame - Wood
AHU �i
11 31
10
310.0 ft2
0
0 0.600000 0
_ 1 S
!j
Exterior Frame - Wood
AHU 1
11 23
10
230.0 ft2
0
0 0.600000 0
I'
WONDOWS
- Orientation shown is the entered, Proposed
orientation.
II,
Wall
Overhang
l; 1� # Ornt ID Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade Screening
�i 1 N
1 Metal Low-E Single
Yes
0.65 0.25
N
54.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds Exterior 5
r 2 N
1 Metal Low-E Single
1'es
0.65 0.25
N
12.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds Exterior 5
f 3 E
2 Metal Low E Single
Yes
0.65 0.26
N
40.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds Exterior 5
4 E
2 Metal Low-E Single
Yes
0.65 0.25
N
10.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds Exterior 5
5 S
3 Metal Low-E Single
Yes
0.65 0.25
N
45.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds Exterior 5
6 S
3 Metal Low-E Single
Yes
0.65 0.25
N
18.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds Exterior 5
7 W
i,
4 Metal Low E Single
Yes
0.66 0.25
N
8.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds Exterior 5
8 W
i'
4 Metal Low-E Single
Yes
0.65 0.25
N
21>.0 fie
1 ft 6 in
1 ft 4 in
Drapes/blinds Exterior 5
i.. 9 W
4 Metal Low-E Single
Yes
0.65 0.25
N
8.0 ft'
1 ft 6 in
1 ft 4 in
Drapes/blinds Exterior 5
10 N
5 Metal Low-E Single
Yes
0.65 0.26
N
48.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds Exterior 5
} 11 N
5 Metal Low-E Single
Yes
0.65 0.25
N
12.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds Exterior 5
12 N
i
5 Meta! Low-E Single
Yes
0.65 0.25
N
8.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds Exterior 5
13 N
�1
5 Metal Low-E Single
Yes
0.65 0.26
N
32.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds Exterior 5
14 N
5 Meta! Low-E Single
Yes
0.65 0.25
N
42.7 ft2
1 it 6 in
1 ft 4 in
Drapes/blinds Exterior 5
15 N
5 Metal Low-E Single
Yes
0.65 0.26
N
10.7 ft2
1 ft o^ in
1 ft 4 in
Drapes/blinds Exterior 5
Ij 16 N
5 Mlemi Low-E Single
Yes
0.65 0.25
!V
20.0 ft2
1 ft6 in
1 ft 4 in
Drapes/blinds Exterior 5
17 N
5 Metal Low-E Single
Yes
0.65 0.25
iI
8.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds Exterior 5
18 N
5 Metal Low-E Single
Yes
0.65 0.25
N
18.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds Exterior 5
19 iV
5 Metal Low-t Single
Yes
0.65 0.2;
Iv
13.0 ft2
1 ft 6 in
1 fi 4 in
Drapes/blinds Exterior 5
3/7/2018 9:21 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 3 of 5
FORM! R405-2017
WOMDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Vi�...
!
Overhang
#
Ornt
ID Frame
Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
20
N
5 Metal
Low-E Single
Yes
0.65
0.25
N
12.0 ft'
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
21
S
7 Metal
Low-E Single
Yes
0.66
0.25
N
24.0 ft'
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
22
S
7 Metal
Low-E Single
Yes
0.65
0.25
N
36.0 ft'
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
23
S
7 Metal
Low-E Single
Yes
0.65
0.25
N
30.0 ft'
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
I
I
24
S
7 Metal
Low-E Single
Yes
0.65
0.25
fV
8.0 ft'
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
25
S
7 Metal
Low-E Single
Yes
0.65
0.25
N
4.0 ft'
1 ft6 in
1 ft 4 in
Drapes/blinds
Exterior 5
26
S
7 Metal
Low-E Single
Yes
0.65
0.25
N
24.0 ft'
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
27
W
8 Metal
Low-E Single
Yes
0.85
0.25
N
80.0 ft'
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
I'.
I'
28
W
8 Metal
Low-E Single
Yes
0.65
0.25
N
20.0 ft'
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
!i
29
N
5 Metal
Low-E Single
Yes
0.65
0.25
N
90.0 ft'
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
I!
!�
! 30
I
N
5 Metal
Low-E Single
Yes
0.65
0.26
N
30.0 ft'
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
31
32
S
7 Metal
Low-E Single
Yes
0.65
0.25
N
30.0 ftz
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
``
N
9 Metal
Low-E Single
Yes
0.66
0.25
N
15.0 ft'
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
I
33
N
9 Nletai
Low-E Single
Yes
0.65
0.25
N
20.0 fizz
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
34
S
11 Metai
Low-E Single
Yes
0.65
0.25
N
16.0 ft'
1 ft 6 in
1 f:4 in
Drapes/blinds
Exterior 5
35
S
11 ivleml
Low-E Single
Yes
0.65
0.26
N
16.0 ftz
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
li
36
I
S
11 Metal
Low-E Single
Yes
0.65
0.25
N
6.0 ft'
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
37
S
11 Metal
Low-E Single
Yes
0.65
0.25
N
36.0 ftz
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
11
38
E
10 Metal
Low-E Single
Yes
0.65
0.26
N
21.3 ft'
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
GARAGE
\
#
Floor Area
^Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
I
1150 ftz
1150 ftz
54 ft
loft
11
#
Scope
Method;
SLA
CFM 5G
EL;;
EgLA
ACH
ACH 50
1
WI olehouse
Proposed ACH(50) .000431
7828.3
429.76
808.24
.3147
7
HEATNG S} S T EM
_
\
#
System Type
Subtype
Efficiency
_ Capacity
Block
Ducts
! 1
Electric Strip Haat/
None
COPA
17 kBtu/hr
1
sys#1
2
Electric Strip Heat/
None
COP:1
34 kBtu/hr
2
sys#2
3
Electric Strip Heat/
None
COP:1
27 kBtu/hr
3
sys#3
3/7/2018 9:21 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R4O5_9017
i
iCOOUNG SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flow SHR
Block
Ducts
1 Central Unit/
None
SEER: 16
24 kBtu/hr
720 cfm 0.8
1
sys#1
2 Central Unit/
None
SEER: 16
58 kBtu/hr
1740 cfm 0.8
2
sys#2
3 Central Unit/
I
None
SEER: 16
36.2 kBtu/hr
1086 cfm 0.8
3
sys0
HOT WATER SYSTEM
\ # System Type SubType
Location
EF Cap
Use
SetPnt Conservation
i Electric None
Garage
0.98 50 gal
80 gal
120 deg
None
SOLAR HOT WATER SYSTEM
` FSEC
Collector Storage
' Cert # Company Name
I�None
System Model # Collector Model
# Area Volume
FEF
None
i
ft2
DUCTS
Supply--
— Return --
Air
CFM 25 CFM25
HVAC #
T
V Location R-Value Area
��
Location
Area Leakage Type
Handler
TOT OUT QN
RLF
Heat Cool
Attic 6 140 ft2
Attic
14 ftz Default Leakage
AHU 1
(Default) c(Default) c
1 1
2 Attic 6 250 ftZ
Attic
25 rtZ Default Leakage
AHU 3
(Default) c(Default) c
2 2
3 Attic 6 160 `rig
Attic
16 ft2 Default Leakage
g
AHU 3
(Default) c(Default) c
3 3
I.
TERAPEkkTURES
Pro ramable Thermostat: None
j g
s
Ceiling Fans:
Cooling ]Jan [ ]Feb [ ] Mar
Healing ,. Jan [[Xj] Feb Mar
j j Apr jjj
j j Apr j
l May [:'.j Jun jX] Jul
j May j 1 Jun I' ] Jul
Aug
Au
�Xj
X Sep j j Oct
4 S [ ]Oct
j j Nov
jXj Nov
j j Dec
[Xj Dec
[[XXII
Venting ( Jan Feb Mar
[X] Apr [
] May (11 Jun ] Jul
Aug[
Sep Oct
[X] Nov
[ j Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
'4 5 6
7
8 9 10
11
12
Cooling (WD) AM 78
78 78
78 78 78
78
78 78 78
78
78
PM 78
78 78
78 78 78
78
78 78 78
78
78
Cooling,(WEH) AM 78
78 78
78 78 78
78
76 78 78
78
78
PM 78
Haafinn /Il1/rl1 nn.i
78 78
78 78 78
78
78 78 78
78
78
PM 68 68
i.
1. Heating (WEH) AM 88 68
PU!! 68 68
1
3/7/2018 9:21 AM
i
68 68 68
68 68 58
68 68 68
bb bo bt3 ua 68
68 68 68 68 68
68 68 68 68 68
68 68 68 68 68
EnergyGaugefl USA - FlaRes2017 Section R405.4.1 Compliant Software
68 68
68 68
68 68
68 68
Page 5 of 5
201
i
d a gum BARRIER AMD uHSULATIOH INSPECTION CUMPONENT CRITERIA
TABLE 402.4A.1
AIR BARRIER AHD INSULATION ENSPECTi IOH COMPONENT CRITERIA
Project
Name: GAMBINA. RESIDENCE Builder Name: 1 P 1Ce J9Xdv5
Street:
CALUMET COURT Permit Office:
City,
Owner:
State, Zip: PORT ST LUCIE , FL, Permit Number. f8) 0 ,03Qq
Design
Jurisdiction:
Location: FL,
Fait Pierce
co,
VMp<JWEN tl
A' d\ SARMER CMI II IE MA NJVJJLATION QIt'1STALLA1 OOH CROTERIA
1
General
A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall
The exterior thermal envelope contains a continuous barrier.
j requirements
air not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceili Ig/attic
The air barrier in any dropped ceiling/soiff it small be aligned with the ; The insulation in any dropped ceiling/soffit
+ insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to shall be aligned with the air barrier.
unconditioned attic spaces shall be sealed.
r
Walls
The junction of the foundation and sill plate small be sealed. Cavities within corners and headers of frame walls shall
The junction. of the top plate and the top of exterior walls shall be sealed. i be insulated by completely filling the cavity with a
Knee walls shalt be sealed. material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windt
m skylights The space between window/doorjambs andframing, and
al u uuU,s -..,....,:.,...y �..� 1
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
(including
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
above
-garage
maintain permanent contact with the underside of
and cantilevered
floors)
;
subfloor decking,or floor framing caul
g cavity insulation shall
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
i
to the top of al! perimeter floor framing members.
Crawl
space walls
Exposed earth in unvented crawl spaces shall be covered with a
. Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawispace walls.
Shafts,
penetrations
{ Duct shafts, utility penetrations, and flue shafts opening to exterior
I
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrov✓
csvit!as
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
= �•��� �+-�•�••�++
n++ L) s,+eu ue prowuea oeaFieen the garage and conditioned spaces.
1 Recessed lighting
i
Recessed Gght fixtures Installed in � the building thermal envelope shall
Recessed light fixtures installed in the building
: be sealed to the drywall. �
thermal envelope shall be air tight and iC rated.
Plun»irg and wiring
Eatt insulation shall be cut neatly to fit around wiring and
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
---
extend behind piping and wiring.
Shower:!--_1
' The air aarr!er insialtad at rxter for walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on a tenor wall
rubs shaf separate them from the showers and tubs.
insulated.
Electricaliphone box on
The air barrier shall be installed behind electrical or communication
exterioir wai,s
boxes or air -sealed boxes shall be installed.
HVAC ragistar boots
HV AC register boots that penetrate building thermal envelope shall be
*hame S:.ih-`'^^. Or di f✓:'i`•I!.
Sealed to . ico
Corce c
When ra:lnir ed lobe sealed, concealed fire sprinklers shall orgy be sealed
spninla=
tr a m .... r hat;z racomma+�ded he rn
""•� t by t arufactiare:. Caulking or other
Iv
adhesive sealants shall not he ussi to fill voids betwesr, fire sprinkler
_
•• _cove!" p!^ateS and Y•✓ails Or Celli!"I'�S.
a. ]n ad•i itiar , inspection
of log walls shall ba !n accordance with the of ICC-500.
3/7/2018 ,;:?1 AIVI
provisions
EnergyGaugew USA - rlaRes20'17 FBC 5th Edition (2017) Compliant
Software Page 1 of 1