Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLOMDA ENERGY EFFIC NCY CODE FOR BUILMNG CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: GAMBINA RESIDENCE SVeet CALUMET COURT Builder Name: (e�9 66106j / City, State, Zip: PORT ST LUCIE , FL, Permit Office: l�Q Permit Number: 9^' 'Y ��C� Owner. Jurisdiction: �� �® Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2) C 1. New, construction or existing New (From Plans) 9. Wall Types (6310.0 sqft.) Insulation Area L 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 3530.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Exterior R=19.0 2240.00 ft2 c. Frame - Wood, Exterior R=11.0 540.00 ft2 4. Number of Bedrooms 5 d. NIA R= ft2 5. Is this a worst case? No 10. Ceiling Types (6924.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 6924.00 ft2 6. Conditioned floor area above grade (ft2) 6924 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 °• A R= ft2 7. Win8ows(953.7 sgft.) Description Area ! 11. Ducts a. Sup: Attic, Ret: Attic, AH: AHU 1 R ftz 6 140 a. U Factor: Sgl, U=0.65 953.67 ft2 b. Sup: Attic, Ret: Attic, AH: AHU 3 6 250 SHGC: SHGC=0.25 c. Sup: Attic, Ret: Attic, AH: AHU 3 6 160 b. U!Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 24.0 SEER:16.00 c. U Factor: N/A ftz b. Central Unit 58.0 SEER:16.00 SHGC: c. Central Unit 36.2 SEER:16.00 d. U-iFactor: N/A ft2 13. Heating systems i kBtu/hr Efficiency SHGC: a. Electric Strip Heat j b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 1.500 ft. c. Electric Strip Heat 34.0 COP:1.00 27.0 COP:1.00 Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor!Types (6924.0 sqft.) Insulation Area ; a• Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 4784.00 ft2 b. Conservation features EF: 0.980 b. Raised Floor R=19.0 2140.00 ft2 None c. N/A R= ft2 - , 15. Credits None Glass/Floor Area: 0.138 Total Proposed Modified Loads: 183.13 ®��� Total Baseline goads: 203.36 !� I hereby certify that the plans and specifications covered by I Review cf the plans and SUE S74 I this calculation are in compliance wi h the Florida Energy I specifications covered by this V Code. calculation indicates compliance �O with the Florida Energy Code. ti ri,,,,:,..'%% "==••;:a�;, PREPA D B : Before construction is completed DATE: j this building will be inspected for ! compliance with Section 553.908 1(I - X w i I hereby certify that this building, as designed, is in compliance 'I Florida Statutes. with thel Florida Energy Code. �G® v5 iD WV, OWNER/AGENT BUILDING OFFICIAL: A,E I I DATE: • ------------ - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as ceri ff 6al factory -sealed in accordance with R403.3.2.1. - compliance requires an Air Harrier and Insulation Inspection : heclrllst in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 AaiW (R402.4.1.2). 3/7/2018 9:21 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: GAMBINA RESIDENCE Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 6924 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Permit Office: Rotate Angle: 0 Street: CALUMET COURT Cross Ventilation: County St. Lucie Jurisdiction: Family Type: Single-family Whole House Fan: City, State, Zip: PORT ST LUCIE , Nero/Existing: New (From Plans) FL, 1 Comment: 1 l CUMAT(E \/ Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site i 97.5 % 2.5 % Winter Summer Degree Days Moisture Range II FL, Fort Pierce FL VERO_BEACH _MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 1425 14250 2 Blockl 3359 33590 3 ....... Block3 2140 19260 i i SPACES - - Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated ? AHU 1 1425 14250 No 0 1 1 Yes Yes Yes 2 AHU 2 3359 33590 Yes 0 1 1 Yes Yes Yes iII t 3 AHU 3 2140 19260 No 0 ...__._.. 3 1 Yes Yes Yes !I _ FLOORS \ # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet it •i Slab -On -Grade Edge Insulation AHU i 124 ft 0 1425 ft2 _-_ 1 0 0 2 Slab -On -Grade Edge Insulation AHU 2 209 ft 0 3359 f? ---- 1 0 0 3 Raised Floor A HJ 3 ___ 2140 ft2 19 1 0 0 (� Poor — / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) �i • Hip Barrel tile 7744 ft2 0 ft2 Medium 0.6 No 0.9 No 20 26.6 A,TT0C II Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 6924 ft2 N N 317120-18 9:21 AM EnergyGaugeO USA - FlaRes2017 Section R405.4A Coi opliant Software Page 2 of 5 FORK R405-2017 CMUNG \ # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) AHU 1 20 Blown 1425 ft2 0.11 Wood 2 Under Attic (Unvented) AHU 2 20 Blown 3359 ft2 0.11 Wood l 3 Under Attic (Unvented) AHU 3 20 Blown 2140 ft2 0.11 Wood WALLS I J ' Adjacent 1 Space Cavity Width Height Sheathing Framing Solar Below _ 1I N Exterior Concrete Block - Ext Insul AHU 1 _Ft 4.09999 In 31 F 10 310.0 ft2 0 Qnro 0 0.600000 0 2 E Exterior Concrete Block - Ext Instil AHU 1 4.09999 18 10 180.0 ft2 0 0 0.600000 0 31 S Exterior Concrete Block - Ext Insul AHU 1 4.09999 31 10 310.0 ft2 0 0 0.600000 0 4 W Exterior Concrete Block - Ext Insul AHU 1 4.09999 54 10 540.0 ft2 0 0 0.600000 0 51, N Exterior Concrete Block - Ext Insul AHU 2 4.09999 80 10 800.0 ft2 0 0 0.600000 0 6' E Exterior Concrete Block - Ext Insul AHU 2 4.09999 48 10 480.0 ft2 0 0 0.600000 0 _ 7 S Exterior Concrete Block - Ext Insul AHU 2 4.09999 57 10 570.0 ft2 0 0 0.600000 0 8' W Exterior Concrete Block - Ext Insul AHU 2 4.09999 34 10 340.0 ft2 0 0 0.600000 0 _ 9 i N Exterior Frame - Wood AHU 3 19 70 9 4 653.3 ft2 0 0 0.600000 0 101 E Exterior Frame - Wood AHU 3 19 50 9 ' 4 466.7 ft2 0 0 0.600000 0 11 S Exterior Frame - Wood AHU 3 19 70 9 4 653.3 ft2 0 0 0.600000 0 121 W Exterior Frame - Wood AHU 3 19 50 9 4 466.7 ft2 0 0 0.600000 0 13! ! E Exterior Frame - Wood AHU 1 11 31 10 310.0 ft2 0 0 0.600000 0 _ 14, i S Exterior Frame - Wood AHU 1 11 23 10 230.0 ft2 0 0 0.600000 0 VVI O \9DQ3WS 1 Orientation shown is thz _ _ entered, Proposed orientation. ` 1 ^T / Wall _ Overhang T 1/ # 1 Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.65 0.25 N 54.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 2 N i Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 3 E 2 Metal Low-E Single Yes 0.65 0.25 N 40.0 ft2 1 ft 6 in 1 ft4 in Drapes/blinds Exterior 5 4 E 2 Metal Low-E Single Yes 0.65 0.25 N 10.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 1 5 S 3 Meta! Low-E Single Yes 0.65 0.25 N 45.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 6 S 3 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft2 1 ft 6 in 1 ft4 in Drapes/blinds Exterior 5 7 W 4 (Metal Low-E Single Yes 0.65 0.2E N 8.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 8 W 4 Metal Low-E Single Yes 0.65 0.26 N 24.0 fie 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 9 W 4 Metal Low-E Single Yes 0.66 0.25 N 8.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 :10 N 5 Metal Low-E Single Yes 0.65 0.25 N 48.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 11 N 5 Metal Low-E Single Yes 0.66 0.26 N 12.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 ;12 N 5 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 13 114 N 5 Metal Low-E Single Yes 0.65 0.25 N 32.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 N 5 Metal Low-> Single Yes O.GS 0.25 N 42.7 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 15 N 5 Metal Low-E Single Yes 0.65 0.26 N 10.7 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 16 N 5 Metal Low-E Single Yes 0.65 0.25 N 20.0 f12 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 17 N 5 Meta! Low-E Single Yes 0.85 0.26 N 8.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 18 N 5 Meta! Low-E Single Yas 0.66 0.25 N 18.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 19 N 5 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 3/7/2018':,:21 AM EnergyGauge® US;; - FlaRes2017 Section R405.4.1 Ccrlpl!ant Software Page 3 of 5 FO RM i R405-2017 WONDOWS Orientation shown is the entered, Pro o- -d orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation fnt Shade Screening 20 N 5 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 i; 21 S 7 Metal Low-E Single Yes 0.65 0.25 N 24.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 22 S 7 Metal Low-E Single Yes 0.65 0.25 N 36.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 23 S 7 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 I 24 S 7 Metal Low-E Single Yes 0.65 0.25 IV 8.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 25 S % Metal Low-E Single Yes 0.65 0.25 IV 4.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 i 26 S 7 Metal Low-E Single Yes 0.65 0.25 N 24.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 I 27 W 8 Metal Low-E Single Yes 0.85 0.25 N 80.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 28 W 8 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 ! 29 N 5 Metal Low-E Single Yes 0.65 0.25 N 90.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 i 1 30 i N 5 Metal Low-E Single Yes 0.65 0.26 N 30.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 j; I' 31 S 7 Metal Low-E Singie Yes 0.65 0.25 N 30.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 32 N 9 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 33 N 9 Metai Low-E Single Yes 0.65 0.25 N 20.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 i 34• S 11 Meiai Low-E Single Yes 0.65 0.25 N 16.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 35 S 11 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 36 S 11 Metal Low-E Single Yes 0.65 0.25 N 8.0 ftz 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 37 S 11 Metal LOW-E Single Yes 0.65 0.25 N 36.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 i 38 E 10 Metal Low-E Single Yes 0.66 0.25 N 21.3 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 CAR # Floor Area Ceiling Area Exposed Wall Perimeter' Avg. Wall Height Exposed Wall Insulation 1 1150 ft2 1150 ft2 54 ft loft 11 # Scope Method SLA CFM 50 EL; EgLA ACH ACH 50 1 Whi lehouse Proposed ACH(50) .000431 7828.3 429.76 808.24 .3147 7 # i System Type T^ Subtype _ Efficiency Capacity Black Ducts 1 Electric Strip Heat/ None COP:1 17 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COPA 34 kBtu/hr 2 sys#2 3 Electric Strip Heat/ None CORI 27 kBtu/hr 3 sys#3 3/7/2018 9:21 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 i FORM R405-2017 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None SEER: 16 24 kBtu/hr 720 cfm 0.8 1 sys#1 2 Central Unit/ None SEER: 16 58 kBtu/hr 1740 cfm 0.8 2 sys#2 3 Central Unitt None SEER: 16 36.2 kBtu/hr 1086 cfm 0.8 3 sys#3 HOT WATER SYSTEM \ # System Type SubType Location EF Cap Use SetPnt Conservation I I Electric None Garage 0.98 50 gal 80 gal 120 deg None SOLARHOT CiEAUER SYSTEM FSEC Cert # Company Name System Model # Collector Model Collector Storage # Area Volume FEF None None ft2 DUCTS Supply -- — Return — Air CFM 25 CFM25 HVAC # i V Location R-Value Area I Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool iAttic 6 140 ft2 Attic 14 ft2 Default Leakage AHU 1 (Default) c(Default) c 1 1 t; 2 Attic 6 250 ft2 Attic 25 ft2 Default Leakage AHU 3 (Default) c(Default) c 2 2 ' Attic 6 160 ft2 Attic 16 ft2 Default Leakage AHU 3 (Default) c(Default) c 3 3 TEMPERATURES �. Programabla Thermostat: None Ceiling Fans: Cooling Jan Feb l IViar Heating Jan Feb Xl Mar Venting [ Jan Feb [XXXIII Mar Apr Appr A May Jun IXj Jul May Jun ] Jul X Aug f Augg Sep Oct �Wji SeP Nov Dec [X] r Ma [ Jun � ]] Juf i [ Au Oct X Nov Decc r. Thermositat Schedule: HERS 2006 Reference Schedule Type 1 2 3 Hours 4 5 6 7 8 9 10 11 12 Cooling (UVD) AM 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (VVD) AM 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 68 Heating (VVEIJ) AM 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 a8 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 3/7/2018 9:21 AM EnergyGauge® USA- FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 i i 2017 i TABLE 402.4.11.1 AR BAR'R9ER AND 9V SULATOM 0HSPEOT�OM COMPONENT CRffERNA Project Name: GAMBINA RESIDENCE Builder Name: Street: CALUMET COURT Permit Office: City, State, Zip: PORT ST LUCIE , FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce Mtn Gti➢ 1� AIR EARROE R CROE'ER➢A ➢iyISBJLATTON ➢R9STALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall d. requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealingmaterial. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soft shall be aligned with the insulation and any gaps in the air barrier shall be sealed. I The insulation in any dropped ceiling/soffit Access openings, drop down stairs or knee wall doors to shall be aligned with the air barrier. i r unconditioned attic spaces shall be sealed. s Walls' The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls shall The junction of the top plate and the top of exterior walls shall be sealed. ; be insulated by completely filling the cavity with a s Knee avails shall be sealed. : material having a thermal resistance of R-3 per inch minimum. j Exterior thermal envelope insulation for framed walls i shall be installed in substantial contact and continuous ! alignment with the air barrier. vVii,dows, skylights i The space between window/doorjambs and framing, and r and doors skylights and framing shall oe sealed. Rim joists ? Rim joists shall include the air barrier. Rim joists shall be insulated. Floors I (including ' The 4ir barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to f above garage maintain permanent contact with the underside of and cantilevered floors) subfloor decking, or floor framing cavity insulation shall , be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the t underside of floor framing and extends from the bottom i to the top of al! perimeter floor framing members. Crawl pace walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shaftsl penetrations i Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. i Batts in narrow cavities shall be cut to fit, or narrow Narrow cavif!es cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recesses' lighting Recessed l;ght, fixtures installed in: the building therrna envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and j plumbing in eAerior walls, or insulation that on installation readily conforms to available space shall -- -- extend behind piping and wiring. Shovjai t_b on exderior wall The air bsrrler Installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be tubs shalt saparate them from the showers and tubs. i;,sulated. E Electric bl/phone box on The air barrier shall be installed behind electrical or communication exterior'Wai,s boxes or air -sealed boxes shall be installed. HVAC rlegister boots HV„C register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drf:+cl!. Conceded When required to be sealed, conceited fire sprinklers shall only be sealed d In a n.anner that is ;eCp!?'irY!OI;dBC by the manufacturer. Caulking or other t adhesive sedanzs shall not be used to fill voids between fire sprinkler cover plates err: v+ails or c�ili as. a. in aGiiitl :1, inspection Of IOp 4vfllls shall Ita in arrnrRn - , r t 3/7/20'i8'�.21 AM EnergyGauge) USA - Flakes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1