PROJECT INFORMATION - DUCT SUMMARY
+�- wrightsoft�- Duct System Summary AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM For. GAMBINA RESIDENCE CALUMET COURT, PORT ST LUCIE, FL Extenal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 800 Cfm Job: Date: Mar 07, 2018 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 800 cfm 193 ft Supply Branch Detail Table Name Design (Btuh) Htg (Cfm) Clg (Cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk I EXERCISE EXERCISE c 2183 32 96 1.000 7.0 Ox0 VIFx 37.4 155.0 st9 -A C 2183 32 96 1.000 7.0 Ox0 VIFx 38.4 155.0 st9 M BATH h 4725 177 98 1.000 7.0 Ox 0 VIFx 12.2 115.0 st3 M TOILET c 716 23 32 1.000 5.0 Ox0 VIFx 12.5 115.0 st3 M Wlc 1 h 1567 59 33 1.000 5.0 Ox0 VIFx 13.1 115.0 st3 M WIC 2 c 24 0 1 1.000 4.0 Ox 0 VIFx 25.5 135.0 st8 MASTER BEDROOM h 5173 194 173 1.000 8.0 Ox0 VIFx 30.0 135.0 st8 MASTER BEDROOM -A h 5173 194 173 1.000 8.0 Ox0 VIFx 27.8 135.0 st8 STUDY C 2218 88 98 1.000 7.0 Ox0 VIFx 5.1 95.0 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (Cfm) FR (fpm) (in) (in) Material Trunk st9 Peak AVF 64 193 1.000 552 8.0 0 x 0 VinIFIX st8 st8 Peak AVF 452 540 1.000 688 12.0 0 x 0 VinlFlx st3 st3 Peak AVF 712 702 1.000 906 12.0 0 x 0 VinlFlx wrl htft` 2018-Mar-07 09:48:58 9 Right -Suite® Universal 2017 17.0.08 RSU08101 Page 1 '�'C'� So E:\Documnets\Wrightsoft WAC\GAMBINA RESIDENCE.rup Calc = MJ8 Front Door faces: S Return Branch Detail Table Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Thank rb3l Ox0 800 800 0 0 0 0 Ox 0 VIFx .` ' * wrightsoft' 2018-Mar-07 09:48:58 A5- Right -Suite® Universal 2017 17.0.08 RSU08101 C'1 EADocumnets\Wrightsoft WAC\GAMBINA RESIDENCE.rup Calc = MJ8 Front Door faces: S Page 2 - ° - 'wrightsoft,, Duct System Summary AHU 2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM For. GAMBINA RESIDENCE CALUMET COURT, PORTST LUCIE, FL Job: Date: Mar07, 2018 By: Heating Cooling Extermal static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply / return available pressure 0.500 / 0.500 in H2O 0.500 0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 1933 cfm 1933 cfm Total effective length (TEL) 238 ft I SupplyDetail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH1 h 981 37 19 1.000 8.0 Ox0 VIFx 26.0 195.0 st14 BEDROOM 4 h 4223 161 102 1.000 7.0 Ox0 VIFx 25.1 160.0 st14 BILLARD ROOM h 2668 101 94 1.000 7.0 Ox0 VIFx 32.1 160.0 st12 BILLARD ROOM -A h 2668 101 94 1.000 7.0 Ox 0 VIFx 40.0 160.0 st12 CABANA BATH h 1372 52 31 1.000 5.0 Ox0 VIFx 36.4 160.0 st10 CAFE; h 3999 152 123 1.000 7.0 Ox0 VIFx 36.1 160.0 st10 DINING h 2922 111 95 1.000 5.0 Ox0 VIFx 42.4 180.0 st15 DINING -A h 2922 111 95 1.000 7.0 Ox0 VIFx 40.4 180.0 st15 FAMIIIY ROOM c 5356 210 232 1.000 8.0 Ox 0 VIFx 48.5 180.0 st13 FAMILY ROOM -A C 5356 210 232 1.000 8.0 Ox 0 VIFx 43.7 180.0 st13 FOYER h 3544 135 131 1.000 7.0 Ox 0 VIFx 57.5 180.0 st11 FOYE -A h 3544 135 131 1.000 7.0 OxO VIFx 56.9 180.0 st11 KITCI fiEN C 2138 1 93 1.000 7.0 Ox 0 VIFx 43.7 180.0 st13 KITCHEN -A c 2138 1 93 1.000 7.0 Ox0 VIFx 36.0 160.0 st12 LAUNDRY c 1010 5 '44 1.000 5.0 Ox0 VIFx 21.0 160.0 st14 LIVING ROOM h 5330 203 155 1.000 8.0 Ox0 VIFx 54.0 180.0 st11 LIVING ROOM -A h 5330 203 155 1.000 8.0 Ox 0 VIFx 55.6 180.0 st11 PANTRY C 21 0 1 1.000 4.0 Ox 0 VIFx 36.7 160.0 st10 WIC 4 c 185 3 8 1.000 4.0 Ox 0 VIFx 22.7 160.0' st14 WINERM i c 39 1 2 1.000 4.0 Ox0 VIFx 44.4 180.0 st15 I ti so wri htft, 2018-Mar-07 09:48:58 9 RightSuite® Universal 2017 17.0.08 RSU08101 ' Page 3 �` Page HVAC%GAMBINA RESIDENCE.rup Calc = MJ8 Front Door faces: S Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st15 Peak AVF 223 192 1.000 638 8.0 0 x 0 VinlFlx st14 st11, Peak AVF 675 573 1.000 860 12.0 0 x 0 VinIFIX st10 st10 Peak AVF 880 728 1.000 954 13.0 0 x 0 VinlFlx st4 st13 Peak AVF 421 558 1.000 710 12.0 0 x 0 VinlFlx st12 st12 Peak AVF 625 839 1.000 785 14.0 0 x 0 VinlFlx st4 st14 Peak AVF 428 366 1.000 785 10.0 0 x 0 VinlFlx st4 st4 Peak AVF 1933 1933 1 1.000 886 20.0 0 x 0 VinlFlx Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb2 Ox 0 1933 1933 0 0 0 0 Ox 0 VIFx IrF wrightsoft` RightSuite® Universal 2017 17.0.08 RSU08101 EADocumnets\Wrightsoft WACIGAMBINA RESIDENCE.rup Calc = MJ8 Front Door faces: S 2018-Mar-07 09:48:58 Page 4 wrightsoft= Duct System Summary AHU 3 QUICK CALCS, INC. 317 ST;LUCIE LANE. FORT PIERCE. FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM For: GAMBINA RESIDENCE CALUMET COURT, PORT ST LUCIE, FL Job: Date: Mar 07, 2018 By: Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply / return available pressure 0.500 / 0.500 in H2O 0.500 / 0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 1207 cfm 1207 cfm Total 'effective length (TEL) 211 ft SupplyBranch-Detail• Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mad Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH12 h 424 27 20 1.000 5.0 Ox0 VIFx 54.6 155.0 st7 BATHI3 C 552 4 25 1.000 5.0 Ox0 VIFx 40.6 135.0 st6 BEDROOM 2 h 4351 280 177 1.000 8.0 Ox0 VIFx 55.6 155.0 st7 BEDROOM 3 h 2898 186 143 1.000 8.0 Ox0 VIFx 44.8 135.0 st6 BRIDGE c 2437 17 112 1.000 7.0 Ox0 VIFx 42.0 135.0 st6 BRIDGE -A C 2437 17 112 1.000 7.0 Ox0 VIFx 28.7 135.0 st5 GUEST BATH h 1473 95 49 1.000 6.0 Ox 0 VIFx 12.8 115.0 st2 GUEST SUITE h 2834 182 138 1.000 7.0 Ox0 VIFx 13.2 115.0 st2 HALF BATH c 689 29 32 1.000 5.0 Ox0 VIFx 24.6 135.0 st5 MECH ROOM c 1138 40 52 1.000 6.0 Ox0 VIFx 13.9 115.0 st1 THEATER c 3134 131 144 1.000 8.0 Ox 0 VIFx 11.8 115.0 st1 THEATER -A c 3134 131 144 1.000 8.0 Ox0 VIFx 19.1 115.0 st1 WIC h 419 27 15 1.000 4.0 Ox0 VIFx 54.6 155.0 st7 WIC 3I h 544 35 19 1.000 5.0 Ox0 VIFx 46.4 135.0 st6 WIC GUEST C 539 6 25 1.000 5.0 Ox0 VIFx 8.0 115.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st5 Peak AVF 46 143 1.000 411 8.0 0 x 0 VinlFlx st1 St7 Peak AVF 334 212 1.000 956 8.0 0 x 0 VinlFlx st6 st6 Peak AVF 576 512 1.000 873 11.0 0 x 0 VinlFlx st2 st2 Peak AVF 859 724 1.000 1094 12.0 0 x 0 VinlFlx st1 Peak AVF 348 483 1.000 732 11.0 0 x 0 VinIFIX � ,- so 9 wri htft'• Page 5 i Right-Suitetal Universal 2017 17.0.08 RSU08101 2018-Mar-07 09:48:58 EADocumnets\Wrightsoft WAC\GAMBINA RESIDENCE.rup Calc = MJ8 Front Door faces: S I Return Branch Detail Table Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb4l Ox0 1207 1207 0 0 0 0 Ox 0 VIFx •,% -- wrightsoft` 2018-Mar-07 09:48:58 �— Right-SuiteO Universal 2017,17.0.08 RSU08101 Page 6 A 'C'A E:\Documnets\Wrightsoft WAC\GAMBINA RESIDENCE.rup Calc = MJ8 Front Door races: S