Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT INFORMATION - PROJECT SUMMARY
wrightsoW Project Summary AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: For. Notes: GAMBINA RESIDENCE CALUMET COURT, PORT ST LUCIE, FL Job: Date: Mar 07, 2018 By: Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db - 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range . M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 18092 Btuh Ducts 3223 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh PIPIng 0 Btuh Equipment load 21316 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Area (ft2) Heating 1425 Cool ingg Volume (ft') 16028 14in 16028 Air changes/hour 0.34 0.18 Equiv. AVF (cfm) 92 49 Heating Equipment Summary Make Trade Model AHRI ref i Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat i 100 EFF 6.1 kW 208288 BFuh 800 cfm 0.038 cfm/Btuh 1.00 in H2O Sensible Cooling Equipment Load Sizing Structure 13537 Btuh Ducts 4576 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 17207 Btuh Latent Cooling Equipment Load Sizing Structure 3052 Btuh Ducts 1225 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 4276 Btuh Equipment total load 21483 Btuh Req. total capacity at 0.70 S H R 2.0 ton Cooling Equipment Summary Make Trane Trade TRANE Cond 4TTR40251-1 Coil TEM6AOB24H21++TDR AHRI ref 7567540 Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 13.0 EER, 16 SEER 16800 Btuh 7200 Btuh 24000 Btuh 800 cfm 0.044 cfm/Btuh 1.00 in H2O 0.81 j Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft" 2018-Mar-07 09:48:51 RightSuite® Universal 2017 17.0.08 RSU08101 Page 1 IEADocumnetsMightsoft WACIGAMBINA RESIDENCE.rup Calc = MJ8 Front Door faces: S i - - wrightsofts Project Summary AHU 2 QUICK CALCS, INC. 317 STCLUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUIC For: Notes: GAMBINA RESIDENCE CALUMET COURT, PORTST LUCIE, FL COM Job: Date: Mar 07, 2018 By: Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 38916 Btuh Structure 31609 Btuh Ducts 11904 Btuh Ducts 12928 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 50819 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 42310 Btuh Method Construction Simplified Average Latent Cooling Equipment Load Sizing quality Fireplaces 0 Structure 4420 Btuh Ducts 4727 Btuh Area (ftz). Heating Cooling 3359 3359 Central vent (0 cfm) 0 Btuh Volume (ft3) 52329 52329 Equipment latent load 9147 Btuh Air changes/hour CEquiv. AVF (cfm) 0.23 0.12 198 Equipment total load 51458 Btuh 106 Req. total capacity at 0.70 S H R 5.0 ton Heating Equipment Summary i Cooling Equipment Summary Make Make Trane Trade Trade Trade TRANE AHRI ref Cond 4TTR6061C1 Coil TEM6AOC6OH51++TDR+UF/HRZ Efficiency 100 EFF AHRI ref 8858422 Efficiency 13.0 EER, 16 SEER Heating input 15.0 kW Sensible cooling 40600 Btuh Heating output Temperature rise 51307 Btuh 24 OF Latent cooling 17400 Btuh Actual air flow 1933 cfm Total cooling Actual air flow 58000 1933 Btuh cfm Air flow factor Static 0.038 cfm/Btuh Air flow factor 0.043 cfm/Btuh pressure Space thermostat I 1.00 in H2O Static pressure Load sensible heat ratio 1.00 0.83 in H2O Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft`a RightSuite® Universal 2017 17.0.08 RSU08101 2018-Mar-0709:48:51 ACCA�E:1Documnets%Wrightsoft WAC%GAMBINA RESIDENCE.rup Cato = MJ8 Front Door faces: S Page 2 - - wrightsoft5 I Project Summary AHU 3 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772.466-6796 Email: QUICKCALCS@AOL.COM For: Notes: GAMBINA RESIDENCE CALUMET COURT, PORT ST LUCIE, FL Weather. Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 12595 Btuh Ducts 6191 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 18785 Btuh Infiltration Method Construction quality Fireplaces Area (ftz) Volume (ft3) Air changesthour Equiv. AVF (cfm) Fort Pierce, FL, US Simplified Average 0 Heat! 49 Co 2ing 140 19756 19756 0.37 0.20 122 65 Heating Equipment Summary jMake ;Trade Model AHRI ref (Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 4.7 kW 16029 Btuh 12 OF 1207 cfm 0.064 cfm/Btuh 1.00 in H2O Job: Date: Mar 07, 2018 By: Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17402 Btuh Ducts 8893 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 24980 Btuh Latent Cooling Equipment Load Sizing Structure 4731 Btuh Ducts 2407 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 7137 Btuh Equipment total load 32118 Btuh Req. total capacity at 0.70 SHR 3.0 ton Cooling Equipment Summary Make Trane Trade TRANE Cond 4TTR40371-1 Coil TEM6AOC48H41++TDR+UF/HRZ AHRI ref 8858455 Efficiency 13.0 EER, 16 SEER Sensible cooling 25340 Btuh Latent cooling 10860 Btuh Total cooling 36200 Btuh Actual air flow 1207 cfm Air flow factor 0.046 cfm/Btuh Static pressure 1.00 in H2O Load sensible heat ratio 0.79 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft" Right -Suite® Universal 2017 17.0.08 R6U08101 2018-Mar-07 09:48:51 E:1Documnets\Wrightsoft 1-1VACIGAMBINA RESIDENCE.rup Calc = MJ8 Front Door faces: S Page 3 m a CT A W (j CA �. . . rn (nAwN-+ On: pp In 1 �` 8P 88 9 G �NNNNN�NNNN+ D+_cNNNNN DfNN(Noo(No �Nw!NONN — m N d8 3c�a>>• F ad 7 F c m 7 7 aka <o y P. f0 p (p Ncoi,�o�no�co�o�o---- pp. . (o p m tz� e e F n co n rS. �, F 2 7 7 A O O a g O 0 0 0 0 O O O O .O -- ---- ------ ---�Q 00 O OOOOOOOCI Oft, ' O O l O N 0 0 0 0 O O O O O O 0 0 0 0 O 0 0 (b 6 k k k k I k� HIM 1 1 9 (6 (b (b 1 .1 1 1 k cb k (b k k (b cb k A. � k k C WC �c >'O 0 O n (�OCCOOOpPp��(O�OpO�OOOOOO��COOOOOOOGOOOOOO�OOOOOG�(O�OOOOppQ(11�p ppp(��p pp O7NOOW0 OOOWpD0000000 WOOOO MEOWOO W OOOOOOOW 00 O � Z5 -- TO N O (D 1C/ � � F F �'F FF f. F i� yN NtoN NN (n N4141 fn NNN (p (pm (p 7 777 77 777 77 777 O �0 00]0000W 0 0 Co 0O000 00 0 0 0 O 0OD pO N Op0S0S0 .8 OAO-O Oo OWSAS0op0 NNW S0O0SAS00 SA-0O 888SOSO 8OpO 8888 W= . O (� (� (.� (� O N O O.00 W W�1 O N O O O A O O� Ap O N O O'O O O OV WV WI N O O O O O; Ap O A O O N O O O O O O V T OAOOOOVV OtO S' Ca WCCfOS/D S O O S C c VV(D C 0 c0 CO SO S COO S S(O S S 00 SS � 0O W O A V O) pW� N (O�1 CN11(W11'O 000 A(OOOOOOCAiIOOlA0000000000 W O C O C OA ON OOS 00000 ' ,(N71 O N A V. N W � o(Wilo 00000 oOVoo 00000WOV00000000rn0000000000000000 = o C O� O(A NO N W000 N O� N co WcN00000TOA000fDO 10gc) SOO OO OOCCAO 0000W C800u 00000 VCoco N 7' Ci SN j �j����'j1� V000 VO 00 V O OO OOO�O OCOJIO OOCVJ100000000OOW+000O00OOOON00000 Q0 O CD O j�0000A00� 00000000co 00000008(DC a 0000Wi ON O 0000000 p� N (U 3 ms CI1 O O l � ' c (A N N pp N N-+O OOOOOONOOOOOOOOOADOOOOOOOOWO000000000(A00000 � cn 7: N� O O O CO,� mW (Am (b O VW CTN"00 Oo W W O(J1 wVW�1 ({{(��aa SS VVOOOOVO O(OOOOOOOOONO.O OOOOONDNA O O O O O Lmn O co 00(01100000 CW� S Ci Cx� j O OC x C n 8 W O1J�� I" wI"cO N 0 0 (pip OW o _pp (C_(��� 0 0000�00�.00000000(11000000+OON0 O.00000000W00000 8 3 T. O C n n D 0 `co 0 r 0 0 9 I moo v o v N O V N O co +!+ wrightsoft' Right-J® Worksheet Job: AHU 1 Date: Mar07, 2018 QUICK CALCS, INC. By: I 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 3 4 5 Room name RoExposed omhe height l '.Room dimensions Room area M WIC 1 13.0 ft 10.0 ft heat/cool 7.0 x 13.0 ft 91.0 ft' M WIC 2 0 it 10.0 ft heat/cool 7.0 x 7.0 it 49.0 ft' Ty Construction number U-value (Btuh/ftk °F) Or HTM (Btuh/ftz) Area (ft') or perimeter (ft) Load (Btuh) Area (ft-) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NOS Heat Cool 6 11 12E-Osw 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 12E-0sw 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 11 G O 12E-0sw 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 16A30td 22A-tph 0.068 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.650 0.650 0.650 0.650 0.650 0.068 0.650, 0.143 0.650 0.650 0.068 0.650 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.650 0.650 0.650 0.540 0.068 0.143 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.032 1.358 in n n in n n n n n n n n n n a e a a a s s s s s s s s s s s s s s w w w w w w nw nw nw - - 0.00 0.00 0.00 0.00 0.00 4.00 0.00 0.00 18.20 0.00 18.20 0.00 0.00 0.00 0.00 0.00 4.00 18.20 18.20 0.00 0.00 0.00 0.00 0.00 0.00 4.00 0.00 18.20 0.00 0.00 18.20 0.00 0.00 0.00 4.00 0.00 18.20 18.20 0.00 0.00. 0.00 0:00 0.90 38.02 0.00. 0.00 0.00 0.o0 0.00.. 2-19 0.00 0.00 14.99 0.00 14.99 0.00 0.00 0.00 0.00 0.00 219 33.77 33.77 0.00 0.00 0.00 0.00' 0.00 . 0.00. 2.19 0.00 14.99 0.00 0.00 14.99 0.00 0.00 0.00 2.19 0.00 33.77 33.77 0.00 0.00 0.00 0.00 2.24 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 130 0 0 0 0 0 . 0 0 91 91 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 130 0 0 0 0 0 0 0 91 13 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 521 0 0 0 0 0 0 0 82 494 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 284 0 0 0 0 0 0 0 204 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .0 0 7 49 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 • 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 16 0 IG12E-0sw. 1�1 LG p W C F I l 6 c)AED excursion -5 0 Envelope loss/gain 1096 484 6 16 12 a) Infiltration b)' Room ventilation 233 0 67 0 0 0 0 0 13 Internal gains: Occupants @ 230 k Appliances/other 0 0 0 O 0 0 Subtotal (lines 6 to 13) 1330 550 6 16 14 15 Less external load Less transfer Redistribution Subtotal Ddct loads 18% 34% 0 0 0 1330 237 0 0 0 550 186 18% 34% 0 0 1 7 1 0 0 2 18 6 Total room load Air+required (cfm) 1 1567 59 737 33 g 0 P4 1 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed ACCA wrigF7tsOTt" Right-Suite(g) Universal 2017 17.0.08 RSU08101 2018 Mar-07 09:48:51 E:1Documnets\Wrightsoft HVAC%GAMBINA RESIDENCE.rup Calc = MJ8 Front Door faces: S Page 2 +!+ wrightsoft' Right-M) Worksheet Job: AHU 1 Date: Mar07,2018 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name M TOILET M BATH 2 Exposed wall 4.0 it 37.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat1cool 4 Room dimensions 7.0 x 4.0 it 1.0 x 244.0 it 5 Room area 28.0 ft' 244.0 ft' .Ty Construction LI-value Or HTM Area (ft2) Load Area number (Btuh/W °F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimfeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12E-0sw 0.068 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 0.00 0:00 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 0.00 0.00 0 0 0, 0 0 0 0 0 2 glazing, clr low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 11 2 glazing, clr low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 ! 13A4ocs 0.143 n 4.00 219 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazinq, clr low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 TLG 12EOsw 0.068 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 Vtl 13A• flocs 0.143 a 4.00 Z 19 0 0 0 0 50 50 200 109 2 glazing, clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazinq, cir low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 12E-Osw 0.068 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing; clr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 13A-0ocs 0.143 s 4.00 2.19 0 0 0 0 180 159 637 348 2 glazing, cir low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 6 6 109 90 2 glazing, clr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 18.20 14.99 0 0 0 0 15 15 273 225 2 glazing, clr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 11GO 0.540 s 0.00 0.00 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 w 0.00 0.00 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 40 32 128 70 140 140 561 306 2 glazing, clr low-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 8 0 146 270 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazinq, cir low-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 Vll, 13A-4ocs 0.143 nw 0.00 0.00: 0 0 0 0 0 0 0_ 0 2 glazing, cir low-e 0.650 nw 0.00 0.00 0 0 0 0• 0 0 0 0 2 glazing, clr low-e 0.650 nw 0.00 0.00 0 0 0 0 0 0 0 0 C I 16A-00td 0.032 0.90 2.24 28 28 25 63 178 178 159 399 F ' I I 22A-tph 1.358 - 38.02 0.00 28 4 152 0 244 37 1407 0 6 c) AED excursion 112 -14 Envelope loss/gain 451 515 3346 1463 12 a) Infiltration- 72 21 664 191 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 j Appliances/other p 0 Subtotal (lines 6 to 13) 523 535 4010 1653 Less external load 0 0 0 0 Less transfer Redistribution 0 0 0 0 14 Subtotal 0 523 0 535 1 4010 1 1655 15 Duct loads 18% 34% 93 181 18% 34% 715 559 Total room load Airl required (cfm) 616 716 7 725 4725 2214 23 32 IT7� 98 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wrightBOft" Right -Suite® Universal 2017 17.0.08 RSU08101 2018-Mar-0709:48:51 .4CCA EADocumnetslWrightsoft HVACIGAMBINA RESIDENCE.rup Calc = MJ8 Front Door faces: S Page 3 co D C) 0 D L S CnA W N O O) T OIA WN-+ p y� r r T �c BS ONN p auC, O_- p O G7 S88 8 6 � � 8 8 33 3 m 9 NN-+N NNN++-+N NNNNN�NNNNN+NNN-+NNNNNNNN�NNNN� N�(p(�[O f010f0 WOO OLIO NG(O WO N�010 f0 lO IO f0 f0 wOOt0ON p1 p7 pp�� p� D p—p�� y—y -- p—� m-- D— m p—� — p—� y—y p-1 y—y p—� y—y D pp-11 p—p11 p—� p—� m p W b �, �. J(') c O iz0.wn�m� o a dN o m ' (p N O o J O $ O c f7i J'O,J N m lo' f ID (D N, N� N N, N, g C N, N, N, N N. N. N C N. N. �. b 777� 7777 �'� j7E 7'77y770J �J7777M=1 'J-JJ N n f0 fC f0 ft] f0 I<] f0 f0 f0 N f0 (O (O 90 (O a f0 y fp * 1] 99. f0 (O ICI f0 (0 q f0 (0 f0 •. N 2 S '�' 0 0 O no 0 O Ono no 00 no 0 O o O O O O O o 0 0 0 an 0 0 a N cb k cb A k k b (b (b (6 (b cb (b c6 k k (b k (b k (b cb k �6 k O v O '$ 000T(C `tLn1 �jQ O0C0ON O ID,. O 00 o 9 mW0000D O O W 0's00000 D O : :E (AN fANN NN NNN 0W bl 0(D (p 0)(0 CD 7 J J JJ JJJ J7 JJJ W OD(Op:O OO �OOOpAo00Wo00000 0000p0 A.0p0 = N f-i O pO QA000p00o0000D pAo00000D p0p p0p0 NO000.0000OOSS00OOOOSOOOOOOOOOOOSSOOOOO8SO'Od8 m= OOO WWONO OO AOONp N0000 OOW -WN0 OOOOAOAOONOOOOO $ONO r.. A00pyCpp000DOOO.0p000pp0OO 0VV) 00OOOOOC) 00O0(000.000 G� Q O � O O wrn00000a0000000000000000000000000000000000oO � O 3r. W O o 0 Z N v 0, cn o OO)0000000O000-O00000--Ooo.O00000.000Oo0Oo0oo X o 2 � rn 00 oo(iloo O I CD cn ocn0000000000000000 00000000000000000000000a00. m 00o sn o m ^c ... g g 0O oowCo w CD CD oo 'w O Ow00000000000000Oo0o0OOO000OOOoOooccOooOOOOo _ O � d 0 8O o o 0 CD 0000 co00000000 a 00000000000 a m 000000000000 0 0 � A O o c � 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 X p A O O O 0 0 0 O O O O O O O O O O O O O O O o O O O o O O O O O O 0 C. O O 0 O 0 O o 0 0 0 0 O O O O 0 O O 0 0 0 0 W E sn S �� _ 8 8 O O O o O O O O 0 0 0 0 o O O o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 T 1- .0 ZEn, A c_ O O rl 7 L In N D ®® m n cn/� G rn O •to D I� ^z VI V CD N rn rF O) rn m 9 OD O N ti O N 2 L d G CO .i.. jl I LL G N V � m n t (Yj ii N�/ a J LL ui U w a Of O LL N Z +. g t pn w T 7 MCIMMM N )000000000 OOO 000 00000 MM 00M MM MMM MM MMM M0M N N OOo (O 000 0) lmn oovc+)2 f�0 28S D N tp� 00000 OOOOa000000000000000000000000000000000t0 - N O MO O OO�-1� N hV L J m O afi V N N N f0 (mD U_ c 2 lCl) p X W _ 0000av0000000000000000000000000000000000000 o o _ U� d d Z O O C O O O O O cq O o 0 0 m 0 0 0 0 0 0 0 0 0 0 0 0 0 O:O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O'� p c 000000000000000000000000.o�o�000000000000rno '- v v M o0 O og n (D oovc� co& g too ca� OOOOOOOOOOOOOOOOOOOOOOOOOOOWOO(D OO O[� O O O O O O O[tV co QJJ O OO a0 OO—�N (D �O N �� N In R n N MM p N N N ❑ V' 7 p X � C7 O O O O O O O O O O O O O O C. O O O O O O O O O O W ON 0 0 OM O O O N O 0 0 0 0 0 0 ctcn � c O LL c Z N O to vm C p, O O O MM O O O O O O O O MC) O O O O O O Oa O O p O v O O M MM o'N O MM O O O O V G O o W N O a0 ^^ p n OSSOS VSSWSWOSS'S Svrz nSS SS SO� SS SSW OS O�O nPz SSO SNS S 00000(I00�0�0000 OfV CM��000000f�C�OC�000cli Mvi OCVO U �= m pp SS pSS OppppNS NSp pSSNN08 pS8Sp N SSNSpS8S N SSp Sp.O o) 000S Odlid0a60 aD00 CDC;goswd00000'r OCO OOCD OO OVO 000000000 N _ Cl) N o O CCC CC CC C CC C C C CN NNN G)Nw NN N4Jm fnw N vl to NN 3 3 � � 333333� LL S�p pp pp pp pp p p po pp p po pppp p pMYp SMOMtA W OoSW V2co tloolno ooulmcl N�po �VN W WpMMco .-S(O fo(ofoOoo(D N N Uto O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o- C BA �m U O. O� 3333 33333333 3 33 33 33 333333 3333 93 c o o 0 0 0 0 0 0 0 0 o a o 0 0 0 00 0 0 o a o 0 0 0 0 0 0 0 0 zz Z p� Z .. p�������a U� N N �N� m y. C c o N N L C .�L O 1=] �3G 'NC NC N� Nm NO: 3 NC_ N_C N_C 3 NC_ NC_ aC N_C NC_I�QV NO_7 NC7 NC_7 NC_l NCI NC_l N N_C NC_7 N_C aC NC_ N_CO a Nm ,Q� NCl NW NCI �m7 T l0' l0 (0 l0 7 f0 l0 l0 @ lU f0 Cl0 (0 l0 10 L m f0 (d f0 f0. 7 Cl0 f0 (0 (0 (0 (U O Q (0 •l0 •f0 •.• O Ln {p 01 N CaC O tlj (yO (p O{pp E � UC l0 f0 ld ^5mmm�mmmmmmmQNm�maNmmmmm,mmmmrnmc�N�mmmQamm� NNNN'"NNNNNNNN N NN NNNNN'�NNNNNN� NNN N-NN4 o yl C N v yry.- NC O.V. E C L'O (0 y a) ° g CIS CIS _ u G xm Ey�gg g 5g} o �9 3 �' �� — E o o— y y y.a " ;c .�W�.�.� FT -- ------- - -�-�--- - o �- m.0 c_._.� U) -I�i�UB0 p F3 ULL r-Nc)V'W to . W L 00 m O (OO CAOM000$O O^c+ o o0000000000 CDC, 00000000io v) t0 N 0 00 0 000o m oo 8 8 Ln W N h U U ^(p0 Oco OM a 00000000.00000000� 0 (O O N O M C)00000000 0 m co m-, f0 C.4 N LO coN N O M rn M N 0 0CC)R1, ffDD O(O 0 M 2 (O co N O O x Z N V'OO CDC CAOO CDC.00O ON OCO 00000000000000000000 O O O OCO.- ((�h o a v W 0p .....c 00000000000000000000000000000 M,0a a wC)0�OCN,� O m N N p] co C1 N V' o' M 0 o N N o M OnO O �M gj�aOV nMO 00M00000 tOpM N(pV cO O��OON�N O p o pp�� �r7 pp 11��OO pip�pp+� 4O OQ M 000 coN I, — 8 cq (b O .co wW p t_ Jm 1f7 CA o O N 0 (n [O N (O (O O� M a)'V'0�M0 n O(NOO 000 OO MCO tO I� �(IOOO (pOM�(p{ 00�(pppp NO (D eF M f"- (O f0 N O f0 M N O lO c0 M C^0 0 tD 000(O O VM, (O P07 (") N N (tAO tO N � '- ch aD f") N ccc000 (OD 0) M N = M M� �O �(o �N V'OOOOI,OOOOOOOONONOOMOOOMOMCON (p V(OD-W ammCDC 0000(' LO f�77 q�q N (p (0 VV cc0')) fV o co Q.-. ui (A v N CC p �p tp ty c�WOrnO(pN.r--(O� MVM'�NONOOMOOOMO��aDNth c`�VM'ONOO OO fOO N.c70 O M co p. O (p O O. N o M O U pp n(� hh ((pp p O O Om Opm�m Op)mQ)COO �OppN O.00 pp77'O [A CAOOTOMIMMO�I�OOI��GO WINO MOD)WQ)07000�0�00 -O oO T.O-CACAO 8 �qOiO�--------aV---CfIOG.=000� C(�I q���� 0(`I�O Och N NNCVO c'op m O pp. p pp pppp ppppp pp pp S N O N O O N N N N N N N N O O O O O M O O O N o S N N N N N N � 0 0 N 0 0 N O N N rn O (p .- c0 O a0 OO V' �O 47 c0 c0 CO c0 00 COS O V' O O O O O c0 O'V c0 cd 00 Cp CO Cd ^ Ci 4 eR O O a0 V' OD cd O 00 N _ M � E OC OoOOODOtO(O(nOO(OO(O(O(oO(o (p (0OO cO((OO(o co (O (O toMM�OpOpOp 0pOppp pp p VV 3 O M w O m OV(O (Co o000000000000000000000000 0000000000000000� m U o 3333 3�3333�33 3 33 33�33 33�333 3333 33 o 0 0 0 o a o 0 0 0 0 0 0 0 o p o 0 0 0 0 0 0 o p o 0 0 C 2 U U U U U U V U U U U U U U U U U U U U U' U U U V U U U V U U CA [A N O O O) O 01 CS [A N CA p Ol O) 07 y OI N O 'O .N C N fO L N C O ]LLJ Cn O Ol m 07 66 C7 N' 01'p N_C C (C_� (C� NC 3 (C� QU (_C� N_C 3 (C_� NC_ (C� NC_ NC_ (C_� (C� (C_� NC_ (_C� (_C� �3G Upy• NC_ (C_� (C_� (C� (CNC_j a T (p (� (0 117 f0 f0 (0 l0 (0 l9 l0 (0 1 (0 (0 (0 f0 l0 10 l0 l0 lU (0 l0 O T C7 .-. a�} •l0 . C O L� {Cp p) N lCl C 'C (p E 0.D. E U G (0 l0 fp (0 (0 10 (p 0101 0101g 0(m Op101OOI CSN rn� rn aN rn rnrn OI co, CD 0) 0)mm MU( W O OIm [7. OOI� NNNN.- N NN N N N p ((�/� O O W C •� C (p ` °yy� O U C.La(p N N� N� NN�NNNNN�NNNNN N.�--��NNNN Ncli N N E �� 00( C5 -pp E N Egw.EEE _$ , x. �s U) U- (D , O v W"I U) +� wrightsoft Right-M Worksheet Job: AHU 2 Date: Mar 07, 2018 QUICK CALCS, INC. By: 317 ST1LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS(cDAOL.COM 1 i Room name FOYER CABANABATH 2 ,Exposed wall 18.0 ft 7.0 ft 3 Room height 32.3 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 18.0 x 21.0 ft 1.0 x 75.5 it 5 Room area 378.0 ftz 75.5 ftz Ty Construction LI-value Or HTM Area (ft') Load Area (ftz) Load number I (Btuh/ftz-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool i 6 12E-0sw 0.068 n 1.90 1.18 0 0 0 0 0 0 . 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr lower 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 11 2 glazing, clr low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 13AAocs 0.143 n 4.00 2.19 0 0 0 0 70 43 174 95 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 5 0 97 80 2 glazing, cir low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 18.20 14.99 0 0 0 0 21 0 388 320 2 glazinq, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 V�/; 12E-0sw 0.068 a 1.90 1.18 0 0 0 0 0 0 0 0 �G 2 glazing, clr low-e 0.650 a 0.00 0.00. 0 0 0 0 0 0 0 0 VI/ 13AAocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 12E-Osw . 0.068 s 1.90 1.18 169 139 265 165 0 0 0 0 2 glazing, cir low-e 0.650 s 0.00 0.00 0 0 0 0 0 0- 0 0 2 glazing,, cir low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 18.20 14.99 30 30 546 450 0 0 0 0 2 glazing;. clr low-e. 0.650 s 0.00 0.00 : 0 0 0 0 0 0. 0 0 e 13A-4ocs 0.143 s 4.00 2.19 419 347 1391 760 0 0 0 0 2 glazing, cir low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 18.20 14.99 24 24 437 360 0 0 0 0 2 glazing, cir low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 11 G 0 0.540 s 15.12 14.31 48 48 726 687 0 0 0 0 W 12E Osw 0.068 w 0.00 0.00 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 'I 2 glazing, clr low-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazinq, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 13A-4ocs _ 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing; cir low-e 0.650 nw 18.20 26.88 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 nw 18.20 26.88 0 0 0 0 0 0 0 0 C 16A-30td 0.032 0.90 2.24 360 360 323 806 0 0 0 0 F E 22A-tPh 1.358 - 38.02 0.00. 378 18 684 0 76 7 266 0 6 c)AED excursion -140 -17 Envelope loss/gain 4372 3088 925 478 12 a) Infiltration 1056 303 126 36 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 900 0 Subtotal (lines 6 to 13) 5428 4291 1051 514 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 0 0 14 15 Subtotal Duct loads 0 5428 0 4291 0 1051 0 514 31% 41% 1660 1755 31% 41% 321 210 Total room load Air required (cfm) 7088 6046 1372 724 270 262 52 31 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wrightsoft" 2018-Mar-07 09:48:51 ACCA " Right -Suite® Universal 2017 17.0.08 RSU08101 E:\Documnets\Wrightsoft I-IVAC\GAMBINA RESIDENCE.rup Calc = MJ8 Front Door faces: S Page 7 - iivrightsoft', Right-M Worksheet 'Job: AHU 2 Date: Mar07,2018 QUICK CALCS, INC. By: i 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS(a)AOL.COM 1 2 3 4 5 Room name R;0= wall Boom height Room dimensions Room area DINING 36.0 ft 12.0 ft heat/cool 1.0 x 454.0 ft 454.0 ft2 WINE RM 0 ft 10.0 ft heat/cool 5.0 x 6.0 It 30.0 ft' Ty Construction number U-value (Btuh/ft' °F) Or HTM (BtulVftz) Area (ft) or perimeter (ft) Load (Btuh) Area or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat cool Gross NIP/S Heat Cool 6 11 %1, 12E-0sw 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, cir low-e 13A4ocs 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, cir low-e 12E-0sw 2 glazing, clr low-e 13A-4ocs 2 glazing, cir low-e 2 glazinq, clr low-e 12E-0sw, 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, cir low-e 13A-4ocs 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, cir low-e 11GO 12E-0sw 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, clr low-e 2 glazinq, cir low-e 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 16A-30td 22A-tph 0.068 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.650 0.650 0.650 0.650 0.650 0.068 0.650 0.143 0.650 0.650 0.068 0.650 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.650 0.650 0.650 0.540 0.068 0.143 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.032 1.358 n n n n n n n n n n n n n n a a a a a s s s s s s s s s s s s s s w w w w w w nw nw nw - - 1.90 18.20 0.00 18'20 0.00 4.00 18.20 18.20 18.20 18.20 18.20 18.20 18.20 18.20 1.90 0.00 4.00 0.00 0.00 1.90 0.00 0.00 0.00 18.20 0.00 4.00 18.20 18.20 18.20 18.20 18.20 18.20 15.12 0.00 4.00 18.20 0.00 0.00 18.20 4.00 18.20 18.20 0.90 38.02 1.18 14.99 0.00 14.99 0.00 Z19 14.99 14.99 14.99 14.99 14.99 14.99 14.99 14.99 1.18 0.00 2.19 0.00 0.00 1.18 0.00 0.00 0.00 14.99 0.00 2.19 14.99 14.99 14.99 14.99 14.99 14.99 14.31 0.00 2.19 33.77 0.00 0.00 33.77 2.19 26.88 26.88 2.24 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 120 0 0 0 0 0 0 0 0 192 0 12 0 0 30 0 0 0 120 0 0 0 0 0 0 0 0 454 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 120 0 0 0 0 0 0 0 0 150 0 12 0 0 30 0 0 0 120 0 0 0 0 0 0 0 0 36 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 480 0 0 0 0 0 0 0 0 601 0 218 0 0 546 0 0 0 480 0 0 0 0 0 0 0 0 1369 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 263 0 0 0 0 0 0 0 0 328 0 180 0 0 450 0 0 0 263 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 30 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C I U)/ a ' C i 1 W i Vj! C F 6 c)AED excursion -101 0 Envelope loss/gain 3695 1382 0 0 12 a) Infiltration b) Room ventilation 775 0 222 0 0 0 0 0 13 Internal gains: Occupants @ 230 0 Appliances/other 0 0 1500 0 0 0 Subtotal (lines 6 to 13) 4470 3104 0 0 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 31% 41% 0 0 5 4475 13691 0 0 13 3117 1275 31% 41% 0 0 11 11 3 0 0 28 28 11 ETotal room load Air required (cfm) i 5844 222 4392 191 15 1 39 2 Calculations approved byACCA to meet all requirements of Manual J 8th Ed ,qCIF - wr�gF�tsoft'" 0709:48:51 �p Right -Suite® Universal 2017 17.0.08 RSU08101 2018-Mar- EADocumnetsMightsolt HVACIGAMBINA RESIDENCE.rup Calc = MJ8 Front Door faces: S Page 8 g a6ed S :sloe/ J000 luoJd 9r" = oleo d-*30N301S3U VNIGNVJ10VAH 11os146uMlslauwn0o4N:3 t9:9b:60 LO-JeW-gLOZ toL9 nsu 90'0'LL LLOZ !esJan!u0 @allnS-346!il . 1400V ;1os;y6��nn -PPI P3 Me r lenueW 10 s;uaulaim ai 11e POW 01 VOOV q PeAojaae suoppoleo 6l 6b4 L£ l86 l lZ 0 8 I (w1o) pannbaJ Jld peOI woOJ 1e101 Oct. 8l£ 0£Z ZSL %l4 %l£ 9 Z %lb %l£ SPeollona Sl £l S 91. 9 l 9 9 !elolgnS bl 0 p 0 0 u ollnqulslpaa 0 0 p p JalsueJl ssa� Peol leu+alxa ssel 90£ 9W 0 0 (£l 019 Sau!I) Ie3o19nS 0 0 Jaglo/saouegddV 0 0 0 0 OEZ @7 sluedn000 :su1e6 Iewalul £L 0 l£ 0 801. 0 0 0 0 uo1lelguan wool{ (q u011eJ11BUl (e Zl SLZ 6£9 0 0 ule6/ssoladolanu3 Ol 0 uolsmoxa c ruy(o g 0 0 8ZZ 0 9 0 09 0 0 0 ££ 00'0 WE 89E'l gdl-VZZ I � 0 O O 0 0 0 0 0 O 0 0 bZ'Z 06'0 Z£0'0 P)0£ V9l 0 0 0 99'9Z OZ'9l Mu 099'0 a-Mol J10 '6u!zel6 Z 0 0 0 0 0 0 0 0 0 88'9Z OZ'9l MU 099'0 a-MOI Jl0 '6UIze16 Z 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 %Z 00'4 Mu E4l'O soo�V£l 'bulze!ti 0 0 0 WEE OZ'Bl M 099'0 a-Mol J10 Z 0 0 0 0 0 0 0 0 OD'O 00'0 M 099'0 a-Mol J10 'Bu!*MI5 Z q 0 0 0 0 0 00'0 00'0 M 099'0 a-Mol Jlo '6UIzelb Z 0 0 0 0 6 0 0 0 0 LL'££ OZ'8l M 099'0 a-Mol J10 '6u1Ze16 Z 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6lZ 00'4 M Ebl'0 soo4bB1 0 0 0 0 0 0 0 0 00'0 I.C31 00'0 ZV91. M S 890'0 OWO Msp-3Zl OEM , M 0 0 0 0 0 0 0 0 66171, We S 099'0 a-MOl J10 '6ulzel6 Z 0 0 0 0 0 0 0 0 66141 0Z'8l S 099'0 a-Mol Jlo '6u1ze16 Z 0 0 0 0 0 0 0 0 66'4l OZ'8l s 099.0 a-Mol Jl0 '6uIZe16 Z OZl 9bl 8 8 0 0 0 0 66'4t OZ'8l S 099'0 a-Mol Jlo '6urzelb Z 0 0 0 0 0 0 0 0 66'4l OZ'8l S 099'0 a-Mol J10 '6u1ze16 Z 09 £L b 4 0 0 0 0 6631 OZ'81, S 099'0 a-Mol J10 '6uize16 Z SOl 0 Z6l 0 8b 09 0 0 0 0 0 6VZ 00'b S Ebl'O S0017-VEL 0 0 0 0 0 . 0 0 00'0 00'0 S 099'0 a-Mol Jlo '6ulZO Z 0 0 0 0 0 0 6611 OZ'8l S 099'0 a-mol J13'6ulzel6 Z 0 0 0 0 0 0 0 0 00'0 00'0 S 099'0 a-Mol JIo '6u1ze16 Z 0 0 0 0 0 0 0 0 00'0 00'0 s 099'0 a-Mol Jlo '6u1ze16 Z 0 0 0 0 0 0 0 0 00'0 00'0 S 099'0 9-Mol J13 '6uiZe16 Z 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 BVI. 061 S 890'0 MSOGZl 'Iju!zelb 0 0 0 00'0 00'0 a 099'0 a-Mol J10 Z 0 0 0 0 0 00'0 00'0 a 099'0 a-Mol J10 '6UIze16 Z I 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6l'Z 0017 a £bl'O soob-V£l '6u!ZLIB 0 0 00'0 00'0 a 099'0 a-Mol JIo Z 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 %1 061 a 890'0 MSO3Zl 66'4l OZ'8l u 099*0 Z 0 0 0 0 0 0 0 0 66'bl OZ'8l u 099'0 a-Mol Jl0 'Bu-zej6 0 0 0 0 0 0 0 0 66'4l OZ'9l u 099'0 a-Mol J10 6u1ze16 Z 0 0 0 0 0 0 0 0 66171, OZ'9l u OS9'0 a Mot Jlo '6ulze16 Z 0 0 0 0 0 0 0 0 66'4l OZ'8l U 099 0 a-Mol J10 '6ui-zel6 Z S 0 0 0: 0 0 0 0 0 6614 OZ'9l U 099'0 a-Mol J10 '6uize[6 Z 0 0 0 0 0 0 0 0 66171. OZ'8l u 099'0 a-Mol J10 'Bu!zelB Z 0 0 0 0 0 0 0 0 6614 OZ'9l u 099'0 a-MOI J13 '6uIzeI6 Z 0 0 0 0 0 0 0 0 6lZ 00'b U £bl'0 sOoII-VEI 0 0 0 0 0 0 0 0 0 (WO 00'0 U 099'0 a-Mol J10 '6urml6 Z 1 1 0 0 0 0 0 0 0 6614 OZ'8l U 099'0 a-Mol J13 '6ulzel6 Z 0 0 0 0 0 0 0 0 00'0 00'0 u 099'O a-Mol 110 '6UIZel6 Z 0 0 0 0 0 0 0 0 6614 OZ'9l u 0199'0 a-Mol J10 '6u1ze16 Z 0 0 0 0 0 0 0 0 8VI, 06'1. u 890'0 Msp-3Zl g 1000 leaH S/d/N SsOJE 1000 1eaH S/d/N SSOJE) I00O leaH (da z11/4n)g) Jagwnu (gnlg) (4) Jalawuad Jo Wig) (11) Jalawuad Jo (zl1/gnlg) PeO� (zl1) eon/ Peol (z1i) eaJV W1H Jp amen-n uollorulsuoO Al z11 0'09 11 0'Ol X 0'9 z11 O'££ 11 0'£E x 01 eam. wool S 1003geag 11 O'Ol 1003/ ag 11 0'01, SuolSUaullp wood{ lg6lag wOOa 4 E 4 0'9 11 0 1[- pesod a Z 4 HBO Aa1NVd aweu wOoa l Wo0'lOV@7S01V0N0!nD :I!ew3 96L9-99t-ZLL :Xed 66L9-99t ZLL :auogd 9464£ l3 '30a31d i8Od '3NV1 31on-i iS LLE :AS ':DNI `scrido moint sioZ,/Ojew :oleo Z nHd :qor weLisvoM @r-iuf 21 01. 96ed S :saoeJ JooQ luoJj BfVy = oleo dru•3oN3aISBU VNIBYVVE)1O /Ni gosl46uM1slouwnoo01:31 1,9:81,:60 LO-JeW-8LOZ 1,01,8011SN 80'0'LL LLOZ IesJanluN ®9l!nS-1461a ! .�yos;y6��nn �i P3 419 f lenueW;o sluawaim al ))e laaw o1 VOOV Aq pamdcfe suo1le)no)eo ZOL 09EZ 1,91. £ZZ4 0 0 0 0 (wJo) pannbaJ �!y peol wool lelol I 999 696 %Lb %LE 0 0 %L4 %L£ speol1on0 SL SL9L £EZE 0 0 8 £ 56L- 09-u011nquls!pa2j IelolgnS bL 0 0 0 0 0 0 0 0 J91sueil ssal Peol IeUJapca ssal L99L OEZE 94l 09 (£L 019 scull) IelolghS 0 0 Ja41o/saouellddy 0 0 0 0 OEZ @@ sluednoo0 :sule6lewajul El 0 4EL 0 L917 0 0 0 0 uoRep— woos (q UOReJlIBUI (e ZL cog I. 49LZ Ski, 09 u1e6/ssol adolmu'3- 9- uolsJnoxe O3H (o 9 0 696 9Z 617Z 0 0 0 SZL 00'0 ZO'8E SSE, I, 4d1-VZZ d 899 EZZ 6bZ 64Z OSL 09 L9 L9 4Z'Z 06'0 ZEO'0 P=_v91. 10 0 0 0 0 0 0 0 0 98'9Z OZ'8 L mu 0S9.0 a-mol J13 '6ulze16 Z 0 0 0 0 0 0 0 0 88'9Z OZ'9L MU INTO a-mol Jlo 'Bu!ZBIB Z 0 0 0 0 0 0 0 0 0 0 0 6LZ 00'V MU EVl'O sOyEL 0 0 0 0 0 LL'EE OZ'8L m 099'0 a-mol JIO 'buIZelb Z 0 0 0 0 0 0 0 0 00'0 00'0 m 099'0 a-mol J13 '6uze16 Z 0 0 0 0 0 0 0 0 00'0 .00'0 m 099'0 a-mol JIa '6ui el6 Z 0 0 0 0 0 0 0 0 LL'EE OZ'9 L m 099'0 a-mol Jp '6u!zel6 Z 6LZ DOtr OOl OOL 0 0 0 0 6LZ 00'17 m E4l'O SoWVU 0 0 0 0 0 0 0 0 00'0 00'0 m 990'0 mso-3Zl 1M 0 06S 0 999 0 9E 0 9E 0 0 0 0 0 0 0 0 LE'bL ZL'91, s 0179'0 OOLL '6ul-16 66'4L OZ'8 L s 099'0 a-mol JIo Z 0 0 0 0 0 0 0 0 66171, OZ'9L s OS9'0 a-mol Jlo '6u1zeI6 Z EY- 0 0 0 0 0 0 0 0 66'17l OZ'81, s 1Z 0 0 0 0 0 0 0 0 66'14 OZ'BL s OS9'0 a-moi '6uize16 I JIo I Z 0 0 0 0 0 0 0 0 66171, OZ'BL s 099'0 a-mol J13 '6ulzel6 Z 0 0 0 0 0 0 0 0 66'til OZ'8L s 099'0 a-mol JIo 'Bu!*-15 Z LLZ 9617 VZL 09L 0 0 0 0 6LZ 00'17 s Etil'0 soo"EI, 0 0 0 0 0 0 0 0 00'0 00'0 s 099'0 0-m91 JIo '6u!ze16 Z 0 0 0 0 0 0 0 0 66'bl OZ'SL s 039'0 a-mol Jlo '6uIze16 Z i 0 0 0 0 0 0 0 0 00'0 00'0 s 099'0 a-moI JIa '6ulZel6 Z 0 0 0 0 0 0 0 0 00'0 00'0 s 099'0 a-mol JIO '6uIZel6 Z 0 0 0 0 0 0 0 0 00'0 00.0 s 099'0 a-mol ip '6u1ze16 Z 0 0 0 0 0 0 0 0 SL'L 06'L s 990'0 ms0-3ZL 0 0 0 0 0 0 0 0 00'0 00'0 a 099'0 a-mol JI0 'tiu!zelb Z 0 0 0 0 0 0 0 0 00'0 00'0 a 099'0 a-mol J13 TUIZe16 Z I 0 0 0 0 0 0 0 0 6l'Z 0017 a UVO SOWVEL 0 0 0 0 0 0 0 0 00'0 00'0 a a-mol Jlo ' Z O 0 0 0 0 0 0 0 0 8L'L 06'L a 8 0 0 MSOl6 o-3Zl 0 0 0 0 0 0 0 0 66171. OZ'81, U 099'0 0-mol J18-bulzelb Z 0 0 0 0 0 0 0 0 66TL OZ 8L U 099'0 a-mol J10 su!616 Z 0 0 0 0 0 0 0 0 66TI, OZ'8L U 099'0 a-mol J13 16u!ze16 Z 0 0 0 0 0 0 0 0 66'bL OZ'8L U 099'0 a-mol Jlo 'Bulzel6 Z ' 0 0 0 0 0 0 0 0 6614 OZ'8 L U OS90 a-moI J13'6ulzel6 Z 0 0 0 0 0 0 0 0 6611 OZ'8 L U 099'0 a-mol JIo '6ulzel6 Z 0 0 0 0 0 0 0 0 6614 OZ'81, U 099'0 a-moI JIo '6u!ze16 Z 0 0 0 0 0 0 0 0 66171. OZ'8 L U OS9'0 a-mol Jlo '6wze16 Z 0 0 0 0 0 0 0 0 6LZ 0031 U C17VO s30td8L AA 0 0 0 0 0 0 0 0 00'0 00'0 U 099'0 a-mol J13 '6ulzei6 Z l L 0 0 0 0 0 0 0 0 66'VL OZ'8L U 099'0 a-mol J13 '6u.6 Z 0 0 0 0 0 0 0 0 00'0 00'0 U 099'0 a-mol J13 'BUIZ816 Z 0 0 0 0 0 0 0 0 66171. OZ'SL U 099'0 a-nnol J10 '6u12e16 Z 0 0 0 0 0 0 0 0 8l'L 061 U 890'0 mso-3Zl / 9 1000 leaH SMIN SSOJO 1000 1eaH s-9 1000 lueH (do z1JMn18) Jagwnu Nn18) (11) Jalawuad Jo (4nle)Jalawuad tSId/N Jo (x1J/4n18) PEO'l (r1J) ew PeOI(z1J) wiv W1H JO anlemn U01loculsuo0 �l elJ 0'6bZ z1J O'SZL eaJe woo -di S 8 0'617Z X 01 11 O'SZL x 01 suolsuawlp woos, 17 1000pea4 11 0'01. 1000/lea4 11 O'Ol 146Ia4 wooal E 11 0'9Z 1J 0 Item PasocIX3' Z 4 W0021(138 )QVMTWH aweu wooaI L Woo'IoY@soltloNoinc) :Ilew3 96L9-994 ZLL xed 66L9-99b-ZLL :auo4d 976bE l.d '20U31d laOd '3NVI Mom iS L LE 'DNS 'scrido :AS a='LOJeUU :Oleo Z nHv :qor, iaa4smaoM or-i4Bw .,:Uos44B1j n -- wrightsoft= Right-J® Worksheet Job: AHU 2 Date: Mar07,2018 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC 4 LAUNDRY 2 Exposed wall O ft O ft 3 Room height 10.0 It heat/cool 10.0 It heat/cool 5 Room dimensions area Z10.0 x 5.0 ft 13.0 x 7.0 It 50.0 ft 91.0 W Ty Construction U-value Or HTM Area (ftz) Load Area (ft' ) Load number (Btuh/ft' "F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12E-Osw 0.068 n 1.90 1.18 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing; clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 11 2 glazing, clr low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazinq, cir low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 12E-Osw 0.068 a 1.90 1.18 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 �+ 13A-4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 CC 2 glazinq, clr low-e 0.650 a 0.00 0.00' 0 0 0 0 0 0 0 0 12E-Osw 0.068 s 1.90 1.18 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glaiing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 9 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 11GO 0.540 s 15.12 14.31 0 0 0 0 0 0 0 0 W, 12E-Osw 0.068 w 0.00 0.00 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazinq, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 V)/ 13A-4ocs 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 nw 18.20 26.88 0 0 0 0 0 0 0 0 L�GG 2 glazing; cir low-e 0.650 nw 18.20 26.88 0 0 0 0 0 0 0 0 C I F 16A-30td 22Atph 0.032 1.358 - 0.9D 38.02 2.24 0.00 50 50 50 0 45 112 91 91 82 204 i i 0 0 91 0 0 0 6 c)AED excursion Envelope loss/gain 45 108 82 182 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13) 45 108 82 682 Less external load Less transfer 0 0 0 0 Redistribution 0 9 0 23 0 0 14 151 Subtotal Duct loads 54 131 14 96 35 717 31% 41% 17 54 31% 41% 29 293 i Total room load Air, required (cfm) 71 185 125 folo 3 8 5 4 4 uaiculations approved byACCA to meet all requirements of Manual J ILFP- wrightsoft- ACCA l Right -Suite@ Universal 2017 17.0.08 RSU08101 IE:IDocumnets%Wrightsoft WACIGAMBINA RESIDENCE.rup Calc = MJ8 Front Door faces: S 2018-Mar-07 09:48:51 Page 11 ZL a6ed L9=97:60 LO-JEN-91.0Z S :saoel JOoQ luoJj 9fy4 = o!e0 dru•30N3(1183N VNMINV'J\0VAH Sosig6uMlsiauwnoo0\:3' LOL90nS21 80'0'LI. LLOZ IesJan!un C,ial!nS-ig6!a 4}os;LjBl jjv% r lenueW;0 sluawai(n ai Ile 199w 04 yOC)y q paAoidde suo(le(nole7 EZL ZSL 99L E (w;o) paJlnbaJ l.rV 9z8z 666E 9LZ7 OL peol Wool lei ol OZS LE6 %L7 %LE L7ZL 9L W? %W speollona SL SOOZ 0 Z90E 0 ME 79 IelolghS bl 0 0 EL 0 S 0 uoMqulslpaa 0 0 0 0 JalsueJl ssal PeOI lewapca ssal SOOZ Z90E EZOE 97 (EL of 9 scull) IelolgnS 0 000E Jaglo/saouegddV j 0 0 0 0 OEZ @@ sluedn000 :sule6 ewes I i £L 0 0 0 0 uollepluan —,d (q 8ZL 977 0 0 uo!leJlllul (e ZL LM 81,9Z EZ 97 ule6/ssol adolanu3 LEI. 86- uo!s noxe CSV (o 9 0 E8L LZ OLZ 0 0 0 7ZE 00'0 ZOW - 84E'L gd)-ya j d 99L 99 7L 7L LZL 87 US 79 7Z'Z O6'0 - ZEO'O Pao£-V9L 10 9E9 t,9E 0 OZ 0 0 0 0 99'9Z OZ'9 L MU OS9O a-mol Jlo '6u!zel6 Z SLZ 971. 0 9 0 0 0 0 99*9Z - OZ'91, MU O99'0 a-mol Jlp ,BU!ZelB Z L9 09L 07 89 0 0 0 0 6LZ 00'7 Mu EtWO soo�d£l /UI 0 0 0 0 0 0 0 0 LL'EE OZ'8L M 099'0 a-mol J13 'Dulzelb Z 0 0 0 0 0 0 0 0 00'0 00'0 M 099.0 a-mol Jp '6u!ze16 Z Sr- 0 0 0 0 0 0 0 0 00,0 00'0 M 099'0 a-mol Jlo '6uizelb Z 0 0 0 0 0 0 0 0 LL'EE OZ'8L M O99'0 a-mol Jlo '6u!zel6 Z 99L 88Z ZL ZL 0 0 0 0 6LZ 0017 M E7L'0 soot-VEL 0 0 0 0 0 0 0 0 00'0 00'0 M 890'0 MsO.3ZL M 0 0 0 0 0 0 0 0 ILE111. ZV91, s Ots'O 0O4 0 0 0 0 0 0 0 0 6617L OZ'8L s 099'0 a-mol Jlo '6ulzel6 Z 0 0 0 0 0 0 0 0 66171, OZ'8L s 099'0 a-mol Jlo '6u!ze16 Z 0 0 0 0 0 0 0 0 66TI, OZ'SL s Z 0 0 0 0 0 0 0 0 66TI, OZ'9 L s 099'0 a-mol J13 '6uizej6 0 0 0 0 0 0 0 0 6614 OZ'8L s 099*0 a-mol J10 '6ul7e16 Z 0 0 0 0 0 0 0 0 66171. OZ'9L s 099'0 a-mol J13 '6uizel6 Z 0 0 0 0 0 0 0 0 6L'Z 00'7 s E7L'O sootrb'EL 0 0 0 0 0 0 0 0 00'0. 00'0 s 099'0 a-mol Jlo '6u!zel6 Z 0 0 0 0 0 0 0 0 66'7L ; OZ'8L s 099'0 a-mol Jlo '6u!zel6 Z 0 0 0 0 0 0 0 0 00'0 00'0 s 099'0 a-mol J10 '6u!zel6 Z 0 0 0 0 0 0 0 0 00'0 00'0 s O99'O a-mol Jlp '6UIzel6 Z 0 0 0 0 0 0 0 0 00'0 00'0 s 099'0 a-mol J10 '6U!Ze16 Z 0 0 0 0 0 0 0 0 8L'L O61 s 890'0 Ms0-3Z1 0 0 0. 0 0 0 0 0 00'0 00'0 a 099'0 a-MOI Jlo 'bulzelb Z 0 0 0 0 0 0 0 0 00'0 00'0 a 099'0 a-mol J!O 'Bu!zel6 Z 0 0 0 0 0 0 0 0 6LZ 00'7 a E7L'O soov-yEL 0 0 0 0 0 0 0 0 00'0 00'0 a 099'0 a-mol Jlp '6u!zel6 Z 0 0 0 0 0 0 0 0 9L'I, 0WL a 890'0 MsO-3ZL. !fh 0 0 0 0 0 0 0 0 66'71. OZ'8L U 099'0 a-mol J!O 'buizel6 Z ON88E 0 lZ 0 0 0 0 66TI,OZ'8L u 059'0 a-mol Jlo '6ulzel6 Z 0 0 0 0 0 0 0 0 66171. OZ'81. U Z 0 0 0 0 0 0 0 0 66'7L OZ'8L U 099'0 a-mo! J10 '6uizej6 1 0 0 0 0 0 0 0 0 66171. OZ'81, U O99'0 a-mol J10 16ulzel6 Z 0 0 0 0 0 0 0 0 66171. OZ'9L U OS9'O a-mol Jlo '6uilzel6 Z I 09 L6 0 S 0 0 0 0 66171, OZ'8L U 099'0 a-mol Jlo '6ulzel5 Z 0 0 0 0 0 0 0 0 66171, OZ'81, U 099'0 a-mol Jp '6ulzel6 Z 8LL 9ZE LS SOL 0 0 0 0 6VZ 00'7 U E7L'0 s307y£L 0 0` 0 0 0 0 0 0 00.0 00.0 u i L 0 0 0 0 0 0 0 0 6631 OT21.. u 00999*0 &-M l ilo '6�iRis a 0 0 0 0 0 0 0 0 00'0 OO'0 U 099'0 a-mol Jlo '6ulzel6 Z 0 0 0 0 0 0 0 0 66171, OZ'81. U O99'0 8-M01 J10 '6ulzel6 Z 0 0 0 0 0 0 0 0 8L'L 06'L U 890'0 MSO-3ZL 9 100O leaH S/d/N s-9 1000 1 le9H SMIN ssoJl) 100O leaH (doz3lMnl9) Jagwnu (4n18) (u) Jalawuad Jo (ynlg) (lI) Jalawuad Jo (zllMnlB) Peol G1I) eaJy Peol G1I) eaJy VUH JO amen u0!lorulsu00 Ajl zII 9'60Z zl3 O'7ZE eaJe woog S it 9'60Z x 0'1, 11 0'91, X 0'81. suolsuaw!p wooaj 7 100011eay it O'ZL 1000/leaq 11 O'ZL lg6!eq woos E II 9'OZ 11 0 11— pasocbq Z 3dH0 N3HOIN eweu W0081 L W00'IOV@S0lV0N01nO :11-3 96L9-99U-ZLL ace j 66L9-99t,-ZLL :auogd 91,64E ld '30-d3ld IHOd '3NVl 310n1'ls LLE :Ae `so- o mono SLOVLOJeW :a;ed Z nHv :qor waysvoM ®f I4B!N ,,Uos4i4Bp n {. £L 06ed S :saoel Jood luoJj 8fN = oleo dni'30N3aISEIN VN18NVEJ1oVAH UOsig6uMlslauwn3oOl:3 L0190nSN 80'0'LL LLOZ IesJaA!un ®alms-lgnu 19:911:60L0-JeW-9LOZ g13os;y6� tnn _�1 . P3 Mg f lenuen jo sjuawann ei Ile 109w 0; V:DOV q pamclde suollelnole- 99L Z4E4 EOZ LEES 994 1.1,L01. 6L4 LZOLL (w1o) paJlnbei JIV peol wooJ 1e101 09ZL ME 0 0 0 09ZL L804 0 0 0 %14 %I•£ 601E Z09L 0 p 0 £89Z 4448 0 0 0 %1.4 %L£ Speollon0 IelolgnS UO!inguls!Paa J91SUEJl ssal PLO1 IeuJayca ssGq SL 41 ME L804 Z09L 4448 (EL 019 Saull) IelolgnS 006 0 0 0 0 0 Jaylo/saoue!lddV 0£Z @o sluedno30 :sule6leulaltyl EL 0 8L1 0 OZ9 0 89E 0 64ZL U048111— woof{ (9 uo!le uul 6 ZL 400Z 994E 44ZL 96LL u!e6/ssoladoWu3 DOL- 841.I. uo!smoxe 03V(b 9 0 L99 0 0 0 0 0 0 0 0 0 0 0 LLZL SS£ 0 0 0 0 0 0 0 0 0 0 0 ZE 96E 0 0 0 0 0 0 0 0 0 0 0 96£ 96£ 0 0 0 0 0 0 0 0 0 0 0 0 LOLL 0 0 0 ZOLZ 0 0 9L9 CZ!, 0 0 0 §OZZ E44 0 0 . 0 994L 0 0 49E 4ZZ 0 0 0 89 464 0 0 0 0 0 0 0 99 0 0 0 464 464 0 0 0 08 0 0 OZ 941, 0 0 0 00'0 4ZZ_ 98'9Z 89'9Z 6VZ LL'EE 00'0 00'0 LL'£E 6VZ 00'0 1,E311, 66171, ZO'8E 06'0 OZ'BL OZ'81 00'4 0Z'8L 00'0 00'0 OZ'8 L 00'4 00'0 ZV91, OZ'81, MU Mu MU M m M M M M s S 89E'1, ZEO'O OS9'0 OS9'O E4L'0 099'0 099'0 099'0 099'0 £4L'O 890'0 O4S'0 OS9'0 ydl-VZZ P10E-V9L a-mol J16 '6ulzei6 Z a-mol Jlo '6u!zel6 Z Soot-VE1 a-mol Jlo 'bu!zelb Z a-mol Jlo 'Bu!zel6 Z a•mol Jlo '6u!zel6 Z a-MOI Jlo '6U!Zel6 Z soot vet Ms0-3ZL poll a-mol J10 '6wzelb Z j 10 J� '' ' M 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 , 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 66'41 6614 66'4L 66'4L 6611 6VZ 60`0 66'4L 0070 00'0 OZ'8L 2'81, OZ'9 L OZ'8 L OZ'8L 0017 00'0 OZ'8I, 00'0 00'0 s S S S s S S S S S 099'0 099'0 099'0 OS9'0 099'0 £4L'O 099'0 099'0 0919'0 099'0 a-mol Jp '6ulzel6 Z a-Mol Jp '6u!zel6 Z a-Mol Jlo '6ulzel6 Z a-mol Jlo '6u!zel6 Z a-mol Jlo '6ulze16 Z sODIp-`d£L a-Mol JID '6uizel6 Z a-Moplo '6uizel6 Z a-mol Jlo '6ulzel6 Z a-mol Jlo '6ulzel6 Z q 0 0 0 0 SZ4 0 0 0 0 0 04S 0. 0 0 0 8LL 0 0 0 0 0 999 0 0 0 0 46L 0 0 0 0 0 0 0 0 0 0 46L 0 0 0 0 0 9£ 0 0 0 0 664 0 0 0 0 0 OLZ 0 0 0 0 £L6 0 0 0 0 0 9Z£ 0 0 0 0 8ZZ 0 0 0 0 0 0 0 0 0 0 8ZZ 0 0 0 0 0 8L 00'0 OVI, 00'0 00'0 6VZ 00'O 911 66TI, 66TI, 66'41 66'4L 00'0 061 00'0 00'0 0017 OQ'O 061 OZ'81 WTI, OZ'91. OZ'9L S S a a a a a U U U U 099'0 990'0 099'0 099'0 EtWO 099'0 890'0 099'0 099"0 099'0 099'0 a-Mol Jlo '6ulzel6 Z MSO-3ZL a-Mol Jp 'tiuizelb Z a-Mol Jlo '6u!zel6 Z sowVEL a-Mpl Jlo '6U!zel6 Z Ms0-3ZL a-mbl Jl0 'bu!zelti Z a-mol Jlo 'BU16115 Z a-mol Jlo '6u!zel6 Z a-mol Jlo 'Bu*-16 Z !tA !N Er- 0 0 0 0 0 0 0 0 0 06 0 60L 0 0 0 9 6614 66171. OZ'81, OZ'8L U U 099'0 099'0 a-mol Jlo '6ulzelb Z a-Mol Jlo '6UIzel6 Z 0 0 ZSZ 0 0 0 0 L94 0 0 0 0 SLL 0 0 0 0 LSL 0 0 0 0 0£9 0 0 0 0 £SLL 0 0 0 0 88Z 0 0 0 0 ZL£ 0 0 66TI. 6611 6VZ 00'0 6611 0Z"81. OZ'8L 0017 00'0 OZ'81, U U U U U 099'0 099'0 E41'0 099'0 099'0 a-mol Jlo '6u!zel6 Z a-mol Jlo '6u!zel6 Z SOob-VEL a=Mol J10 'Bu!zelB Z a-mol Jlb '6u1ze16 Z L L 0 0 0 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00'0 66'41• 81.1 00'O OZ'8 L 061 U U U 099'0 099'0 890'0 a-mol J10 '6u!ze16 Z a-mol Jlo-'6u1ze16 Z Msp-3ZL 9 1000 1 MH S/d/N ssoJO 1000 IeaH SON ssOJO 1000 leaH JO (jozll/4n18) ants"-n Jagwnu u0110ruisu00 All ! Nme) PeOI (14j) Jalawuad Jo Gm) eaJV (4n113) PeOI (11) Jalawped Jo Gu) eaJV (z7J/4n18) MH zlJ O'96E 11 0'9L X O'ZZ 1003MOLI 11 8'01, 11 0'ZE NOON Gu"I9 z1J 010, u 0'61, X OWsuolsuaw!p 1000/lea4 11 OZL 11 0'89 NOOa l"11WVd eaJe wooai woog 146!94 wood, 11— p9sOdx3' aweu woos! g 4 £ Z L N00'IOV@S0lV0N01nD :l!ew3 96L9-99h-ZLL :xe j 66L9-99b ZLL :auogd 9464E ld '30b3ld -LUOd '3NVl 31On1 iS LL£ :AS •Owi `smvo xmu OLOVLOJEW :Oleo Z nHv :qor iaaysvoM w-wl')1N „�}os;ysi.onrI .F gill Om o4 n c C m 1 � V X CA m C 0 m T C O 0 oT CD W 2 D1 A W N � - K V i, m b> A C 0 n D n co 0 0 0 K LZ U3 S 0 �oov°0 m•• + Wrightsoft' Right-M Worksheet AHU 3 j QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Mar 07, 2018 By: 1 Room name HALL 2 WIC 2 2 3 Exposed wall Room height 0 ft 9.3 ft heat/cool 7.0 ft 9.3 ft heat/cool 4 5 Room dimensions Room area 6.0 x 3.0 ft 18.0 ft2 6.0 x 7.0 ft 42.0 ft2 yTy Construction number LI-value (Btuh/1`1:2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 I 12E-0sw 2 glazing, cir low-e 2 glazing, clr low-e 0.068 0.650 0.650 n n n 1.90 0.00 18.20 1.18 0.00 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 2 glaiing, clr low-e 2 glazing, clr low- 6.650 0.650 n n 0.00 18.20 0.00 14.99 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 .e 13AAocs 2 glazing, clr low-e 2 glazing, clr low-e 0.143 0.650 0.650 n n n 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, clr low-e 2 glazinq, clr low-e 12E-0sw 2 glazing, cir low-e 13A-4ocs 2 glazing, cir low-e 2 glazinq, cir low-e 12E-Osw 2 glazing, clr low-e 0.650 0.650 0.650 0.650 0.650 0.650 0.068 0.650 0.143 0.650 0.650 0.068 0.650 n n n n n n a a a a a s s 0.00 0.00 0.00 0.00 0.00 0.00 1.90 18.20 0.00 0.00 0.00 1.90 18.20 0.00 0.00 0.00 0.00 0.00 0.00 1.18 33.77 0.00 0.00 0.00 1.18 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0` 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ' G VII 2 glazing, cir low-e 2 glazing, cir low-e 0.650. 0.650 s s 18.20 18.20 14.99 14.99 0 0 0 0 0 0 0 0 0 0" 0 0 0 0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 13A-4ocs 2 glazing, clr lower 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, cir low-e 11G0 12E-0sw 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, cir low-e 2 glazinq, clr low-e 13A-4ocs 2 glazing, cir low-e 2 glazing, clr low-e 16A 30td 22A-tph 0.650 0.650 0.143 0.650 0.650 0.650 0.650 0.650 0.650 0.540 0.068 0.143 0.650 0.650 0.650 0.650 0:143 0.650 0.650 0.032 1.358 - s s s s s s s s s s w w w w w w ` nw nw 'nw - 0.00 18.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.90 38.02 0.00 14.99 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.18 0.00 0.00 0.00 0.00 0.00 .. 0.00 0.00 0.00 2.24 0.00 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -. 0 0'' 0 18 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 . 18 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 40 0 0 0 0 0 0 0 0 0 0 0 65 0 0 0 0 0 0 0 0 42 0. 0 0 0 0 0 0 0 0 0 0 ' 65 0 0 0 0 0 0 0 0 42 0, 0 0 0 0 0 0 0 0 0 0 124 0 0 0 0 0 0 0 0 ' 38 0 0 0 0 0 0 0 0 0 0 0 77 0 0 0 0 0 0 0 0 94 0 I I W N113AAocs i C F e r i I 6 c) AED excursion p 0 Envelope loss/gain 16 40 162 171 12 a) Infiltration b) Room ventilation 0 0 0 0 117 0 34 0 13 Internal gains: Occupants @ 230 1 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 16 40 278 205 14 15 q Less e:demal load Less transfer Redistribution Subtotal Duct loads 49% 51% 0 0 -16 0 0 0 0 -40 0 0 49% 51% 0 0 3 281 138 0 0 7 211 108 Total room load Air required (cfm) i 0 0 0 0 419 271 319 15 Cal ACCA of Manual J Wrigft7tsOft" Right -Suite® Universal 2017 17.0.08 RSU08101 E:\Documnets\Wrightsoft HVAC\GAMBINA RESIDENCE.rup Calc = MJ8 Front Door faces: S 2018-Mar-07 09:48:51 Page 15 + - rightsoft- Right-J® Worksheet AHU 3 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Mar07, 2018 By: 1 u Room name BATH 2 BATH 3 2 3 Exposed wall Room height 6.0 ft 9.3 ft heat/cool 0 ft 9.3 ft heat/cool 4 5 Room dimensions Room area 1.0 x 81.0 ft 81.0: ft2 1.0 x 46.0 ft 46.0 ft2 i Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N!P/S Heat Cool Gross N/P/S Heat Cool 6 11 w 12E-0sw 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, cIP Iow-e. 2 glazing, cfr low-e 0.068 0.650 0:650 0.650 0.650 ' n n , : n ' n n 1.90 0.00 18.20 0.00 18.20 1.18 = 0.00 14.99 0 00 14.99 0. 0 ..- . 0 `" 0 , ;... 0 ': 0 `- 0 =' 0 0 _" ' 0 0 0 0 0 0 0 0 0 0 0". 0 0 0 '. 0 0 0 0"- O 0 :.. 0, .:. 0: 0 r 0 :. 0 ' . 0 0 0 0 0 0 I I V�/ �" 13A-4ocs 2 glazing, dr low-e 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, cir low-e 2 glazinq, clr low-e 12E--0sw . 2 glazing, clr low-e 13A-4ocs 2 glazing, cir low-e 2 qlazinq, clr low-e 12E-0sw , 2 glazing, cir iow e. 0.143 0.650 0.650 0.650 0.650 0.650 0.650 0.650 0.650 0.068 0.650 0.143 0.650 0.650 0.068 0.650 n n n n n n n n n a a a a a s s 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.90 18.20 0.00 0.00 0.00 1.90 18.20 0.00 0.00 0.00 bm 0.00 0.00 0.00 0.00 0.00 1.18. 33.77 0.00 0.00 0.00 - 1.18 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. . .0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.-' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .'.' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 - • 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 i I I l I C V u I p R WI_ C F 2 glazing, cir low-e 2 glazing; cir low-e 2 glazing, cir low-e 2 glazing, clr low-e, 13A-4ocs 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, clr lower 2 glazing, clr low-e 2 glazing, cir low-e 11G0 12E-0sw 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazinq, cir low-e 13A4ocs 2 glazing, cir low-e 2 glazing, clr low-e 16A-30td 22AAph 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.650 0.650 0.650 0.540 0.068 0.143 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.032 1.358 s s s s s s s s s s s s w w w w w w 'rtw nw nw .. - 18.20 18.20 0.00 18.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.90 38.02 14.99 14.99 0:00 1499 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2.24 0.00 0'. . 0 0 :: 0 0 0 0 0 0 0 0 0 56 0 0 0 0 0 0 0 0 81 0 0 0 '. 0 ` 0 0 0 0 0 0 0 0 0 56 0 0 0 0 0 0 0 0 81 0' 0 0 0 , .. 0 0 0 0 0 0 0 0 0 : 106 0 0 0 0 0 0 0 0" 73 0 0 0, 0 0 0 0 0 0 0 0 0 0 66 0 0 0 0 0 0 0 0 181 0`" 0 0 0; ' 0 0 0 0 0 0 0 0 0 - '. 0 0 0 0 0 0 0 0 0: 46 0 0 0 0 .: ; ; ' , 0 0 0 0 0 0 0 0 0 • 0 0 0 0 0 0 0. 0 0 46 0 0 0 .. 0 .. 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 0' 0 41 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 103 0 P i I i I W I C p d 6 a c) AED excursion 0 0 u Envelope loss/gain a 179 - 247 41 103 12 a) Infiltration b) Room ventilation 100 0 29 0 0 0 0 0 13 Initemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 250 Subtotal (lines 6 to 13) 279 276 41 353 14 15 Less external load L6.ss transfer R" distribution Subtotal Duct loads 49% 51% 0 0 5 284 140 0 0 13 290 148 49% 51% 0 0 5 46 23 0 0 12 365 187 Total room load Air required (cfm) 424 27 438 201 ]_1 69 4 552 25 of Manual J -Ith" wrightsoft- Right -Suite@ Universal 2017 17.0.08 RSU08101 E:1Documnets\Wrightsoft WACIGAMBINA RESIDENCE.rup Calc = MJ8 Front Door faces: 2018-Mar-07 09:48:51 Page 16 - wrightsoft- Right-M Worksheet AHU 3 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: M ar 07, 2018 By: 1 Room name WIC 3 HALL 3 2 ,Exposed wall 9.0 ft 0 ft 3 4 Room height Room dimensions 9.3 ft heat/cool 9.3 ft heat/cool 5 ) oom area 1.0 x 57.0 ft 57.0 ft2 5.0 x 4.0 It 20.0 ft? I Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuhlft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12E-0svv 0.068 n 1.90 .. 1.18.. 0 0 0; .: 0 0 0 0 0 2 glazing, clr low-e ` 0.650 n 0.00 .. 0.00 0 0 0 0 0 0 0 0 2 glazing; clr low-e 0.650 n 18.20 14.99 0 `. 0 0- _- 0 0 0' 0 0 I I 2 glazing; 'cir 16" 0.650 n_ 0.00 .' 0.00 : 0 0 0 0:' 0 0 0 0 11 2 glazing, clr low-e 0.650 n 18.20 14.99 ,j ' -. 0 0 0 ; '. 0 0 0 0 0 13A-4ocs 0.143 n 0.00 0.00 0 0 0 0 ., 0 0 0 0 2 glazing, clr low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 I 2 glazing, clr low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 I 2 glazing, clr low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 I 2 glazing, clr low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 I 2 glazinq, clr low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 V)% 12E-0sw ,.. 0.068 a 1.90 1.18 0 0 0 0 0 0 0 0 t=G 2 glazing; clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0• 0 �•��)f 13A-4ocs 0.143 a 0.00 0.00 0 0 0 0 0 0 0 0. 2 glazing, clr low-e 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 I s 2 glazinq, clr low-e 12E-Nw 2 glazing, clr low-e 0.650 0.068 0.650 a , s s 0.00 1.90 18.20 0.00 1.18 14.99 0 0 .. 0 0 0 0 0 0 0 0 0 0 0 0 `: , 0_ 0 0 0 0 0 0 0 0 0 B 2 glazing, clr lii 4. 6.650 s 18.20 14.99 0 0 0 0'. 0 0 0. 0 I 2 glazing; clr low-e 0.650 s 18.20 14.99 0 0 0 0.: 0 0 0 0 I 2 glazing; clr low=e 0.650 s 0.00 6.00 j- 0 0 0 0 0 0. 0 0 2 glazing, cli low-e 0.650 s 18.20 94.99 ` 0. 0 0•' 0 0 0 0 0 ' 13A-4ocs 0.143 s 0.00 0.00 0 0 0 0 0 0 0 0 I 2 glazing, clr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 I I 2 glazing, clr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 I 2 glazing, clr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 I I 2 glazing, clr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 11GO 0.540 s 0.00 0.00 0 0 0 0 0 0 0 0 Wj 12E-Osw, 0.068 - w 1.90 - • 1.18 84 84 159 99 0 0 0 0 %f 13A-0ocs 0.143 w 0.00 0.00 0 0 0 0 _ 0 0 0 0 2 glazing, clr low-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 I I 2 glazing, clr low-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 l 2 glazing clr low-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 Val I-- G 13A-4ocs 0143 nw 0.00 : 0.00 0: 0 0 0 0 0 0. 0 2 glazing clr low-e ` ' 0.650 nw -0.00 0,001. 0 0 . 0 0 ` 0 0 0 0 t 2 glazing, cir low-e 0.650, nw 0.00 0.00 .: 0, 0 0.. 0 0 0 6 0 C 16A-30td 0.032 0.90 2.24 57- 57 51 128 20 20 _ 18 45 F 22A tph 1.358 38.02 0.00 0 0 0• 0 0 0 0 0 6 c �AED excursion 0 0 w Envelope loss/gain 210 227 18 45 12 1 a) Infiltration 150 43 0 0 b) Room ventilation 0 0 0 0 13 Irtemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 - 0 Subtotal {lines Edo 13) 361 270 18 45 L less extemal load Less transfer 0 0 0 0 14 Rbdistribution Subtotal 0 4 0 10 0 18 0 45 15 D,6ctloads 49% 51% 179 143 49% 51% 0 0 Total room load '423 Air required (cfm) 1 544 35 19 0 0 ::10 ACCA Of I" wrightsoft- RightSuite® Universal 2017 17.0.08 RSU08101 E:\DocumnetslWrightsoft WAC%GAMBINA RESIDENCE.rup Calc = MJB Front Door faces: 2018-Mar-07 09:48:51 Page 17 N +� wrightsofta Right-J® Worksheet AHU 3 QUICK CALCS, INC. 317 STILUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Mar 07, 2018 By: 1 2 3 4 5 Room name Exposed wall Room height �Room dimensions Room area BEDROOM 3 30.0 ft 9.3 ft heat/cool 1.0 x 210.0 ft 210.0 fN GUEST SUITE 36.0 ft 9.3 ft heat/cool 1.0 x 280.0 ft 280.0 f 2 y Construction number U-value (Btuh/ t2-°F) Or HTM (Btuhlft?) Area (ft2) or perimeter (ft) Load (Btuh) - Area (ft2) or perimeter (ft) Load (Btuh) Heat CcoI Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 A 12E-0sw 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing; clr low'-e 2 glazing; clr low- 13A-0ocs 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, cir low-e 12E-0sw 2 glazing, cir low-e 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 12E-0sw . - 2 glazing, cir low-e 2 glazing, clr'lowre 2 glazing,,'clr low-e, 2 glazing, clr low=e 2 glazing,_ clr low-e' 13AAocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, clr.low-e 2 glazing, cir low-e 11GO 12E-Qsw 13A-0ocs 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing clr low-e 13A-4ocs 2 glazing clr low-e 2 glazing. cir low-e 16,430td 221ktph` 0.068 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.650 0.650 0.650 0.650 0.650 0:068 0.650 0.143 0.650 0.650 0.068 0.650 6.660, 0.650 -0.650 0.650 0.143 0.650 0.650 0.650 0.650 0.650 0.650 0.540 0.068 0.143 0.650 0.650 0.650 0.650 0.143: 0.650 0.650 0.032 1'.358 n n : n n n n n n n n n n n n a a a a a s s s s s s s s s s s s s s w w w w w w nw ' nw " nw - - 1.90 0.00 18.20 '0.00 18.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.90 18.20 0.00 0.00 0.00 1.90 18.20 18.20 18.20 6.60 18.20 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 0.00 1.90 0.00 0.00 0.00 0.00 0.00 0.00 0.06 0.00 0.90 38.02 . ': 1.18 0.00 `. 14.99 <' 0.00 14.99 0.00 0.00 0.00 0:00 0:00 0.00 0.00 0.00 0.00 :. 1:18 33.77 0:00 0.00 0.00 1.18 14.99 14.99 14.99 ` 6.00 ;, 14.99 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00 . 0.00 2.24 0.00 0 0 0 0 -. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. 158 0 8 - 0. 0 _ . ,36 0 0 0 0 0 0 0 0 121 0 0 0 0 0 0 0 0 210 ' . 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 114 ' 0 8 0 0 36 0 0 0 0 0 0 0 0 121 0 0 0 0 0 0 0 0 210 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 217 0 146 0 0. 655 0 0 0 0 0 0 0 0 230 0 0 0 0 0, 6. 0 0 188 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 135 0 120 0 0 540 0 0 0 0 0 0 0 0 143 0 0 0 0 0 0" 0.-, 0 470 0 ... - 0 ;' 0 0 0 0 0 0 0 0 0 0 0 0 0 102 0 0 0 0 130 6 : 0 15 0 0 0 0 0 0 0 0 0 0 102 0 0 0 0 0 0 0 0 280 '' 14 0 0 0 0 0 0 0 0 0 0 0 0 0 0 102 0 0 0 0 109 ' 6.- 0 15 0 0 0 0 0 0 0 0 0 0 102 0 0 0 0 0 0 0 - 0 280 2. , 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 195 '0 0 0 0 208 109 0 273 0 : 0 0 0 0 0 0 0 0 0 195 0 0 0 0 0 0' 0 0 251 68 0 0 0 0 0 0 0 0 0 0 0 0 0 0 121 0 0 0 0 129 90 r. 0 225 0 0 0 0 0 0 0 0 0 0 121 0 0 0 0 0 0 0 0 627 0 u l X b q l V/1 l�G (-� V I B 6 I G I Wp �i G C F 6 c�AED excursion 0 0 Envelope loss/gain m 1436 1408 1299 1313 12 a) Infiltration b) Room ventilation 501 0 144 0 601 0 172 0 13 InGGtemal gains: Occupants @ 230 y Appliances/other D 0 500 0 0 500 Subtotal (lines 6 to 13) 1937 2052 1900 1986 14 15 Less Less Redistribution Subtotal Duct external load transfer loads 49% 51% 0 0 6 1943 955 0 0 15 2067 1056 49% 51% 0 0 0 1900 934 0 0 0 1986 1015 Total Ail room load required (cfm) l 2898 1861 3123 1431 2834 182 3001 138 C:alculatlons approved byACCA to meet all requ w1-i4jhtsoft•' Right -Suite@ Universal 2017 17.0.08 RSU08101 E:%Documnets%Wrightsoft WACIGAMBINA RESIDENCE.rup Calc = MJ8 Front Door faces: 2018-Mar-07 09:48:51 Page 18 A 2 ui p N a 7 � m 2 O U _I U O J Q Y U 5 E W m rn I. O cli ai LL .�L L Z � � O N V co ® Q I. n �M V ++ t ►' Y r O a L6 Q V M LL W U W a O LL O H 4j W g W T r) J_ c� 0000000000 00001Z0000000000000000000000a o000N0 O QI •ct0 OM � OOO�tyh V} Opp o0000000000000�O00000000000000000000000000wo � r�o ool.rc- nOO L � rL p O r N (DN O V N NV' f0 0 O _ ' p X '.. .. .. . Vn _ O O O O O O O O O O O O O OS O O O O O O O O O O O O O O CD O O O O O O O O O O (3' O O O fj) e w o O t `,E oOo oo ooO o00oo as COO COO oo oOo oo Can 000o0 CDC 000 ONo p N CL yyy o ' 000000000000000000000000000000000000000000'.1�0 IOC O f� l0 a OO OOO�h� MN ON M N 8 � � 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0'O O O O O O O O O O O O O O O O O M O (O f'7 0 0 M O O O CO fp L � m O l0 (O O NOl � O - C9 O x U 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0"0 O O O O O o 0 0 0 0 0 0 o a 0 0 0 0 0 0 Op O'O O � o � n e 0 a � 1. m 0 'E •2 OOOoOOOOOOOOOOOOOOOOoCO000OoOOO000000000000o O CA n o v ODOOOSOOOOSSS O[A,O 0000 0Sv'Iz SS S:cS a) a)O S'S S S 0 S S SOCr 00SS O'000NO g ov.0 "6600006Ool-:Vida Q:-Ii 0loo0add 00:00000000:cdo �� U .. m Erp SSSSp W- NSO S.SN a S I.. SOS OOOD S Ili SpSS-S STO �p OCO 00o000o00.-00 o00.r- 00 aD GD O 000 o o 00000�--000C C70CC000 r r �O •`� = � L O CC C C7 Ndp07 NN fgmN Ny Nul vl N W 333 33 33Cc C � � CCpC CppC CC CppC LL py pNpN ppC ppC �ppp �pOS N�OOIO tO IO tO tO BOO �Op �pO OcO(O rf0f0Oc0 V�tfO(DM pO �pOS SS�rV N�pO 8 SD1FOi 0OO�ppp a 2LCOO u4Oi W; N^ fLDOO gmcLoidd6d66d60000o00o00000a- D m OID 3.3.33 3��3�3333'3 33 33��33. 33333� 333��:33 oo"a'o 0 oaoo 0 00 oa o 00000 00 00 'Uo -Z� pp�� pu �uu you o �ii Cy yCCCC NC m � l0 O � mr c N� of 3CC CC p���� p�� WOI IQ��N.I0 NM'0= CCC C3 _CC 3-C CCCG V CC C C_C _C 3 ��� �� mN NN N N N m -ly � �N N�a NN NNN `mo4"N cN9 ,N ty WO1 N0 O E2 yA p � n (yp N (p O CC E �70 E 3�EN UC ^ OW Of OI^�101001 O1mmC7N CAMOIQNm00101m� Ol Ol�m0laa <— m0l 0. QNQN N N'N N N N N N N N N N r N r N N r N N N N N N N N N NN r eN- r O o NE p� C C N E y O a w 8 m St �0•c c3 s� _ (�I z 4 Y O u. p p p ��pop�S5,O OO _Q�-W.�-�.�_ vo O lil� C� `u�a CO 5 O g_ ul n7 NN O s �d U � I� r N M t iO t0 O .M-• W i T 4- wrightsoft Right-M Worksheet AHU 3 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Mar 07,2018 By: 1 Room name GUEST BATH THEATER 2 3 Exposed wall Room height 22.0 ft 9.3 ft heat/cool 62.0 ft 9.0 ft heat/cool 4 5 Room dimensions Room area 8.0 x 14.0 ft 112.0 ft2 27.0 x 18.0 ft 486.0 ft2 s Ty Construction number U-value (Btuh/ft2--°F) Or HTM (Btu ft2) Area- (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 q I 12E-Osw 2 glazing, cir low-e 2 glazing, clr low 0.068 0.650 0.650 n n , n 1.90 0.00 18.20 - 1.18 0.00 14.99 0 0 0 0 `:: 0 0 0 0 0 - 0 0 0 243 0 0 243 0 0 463 0 0 288 0 0 11 k ;' 2 glazing, cir low-e. 2 glazing, cir low-e 0.650 0.650 - n . n 0.00 18.20 0.00 . 14.99 - 0 0 0 ;;' 0 0 0 0 0.. i 0 0 0 0 '.. 0 0 0 0 13A-4ocs 2 glazing, cir low-e 2 glazing, clr low-e 0.143 0.650 0.650 n n" n 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 , 0 0 0 , 0 0 0 0 0 0 0 0 0 h I 2 glazing, cir low-e 2 glazing, cir low-e 0.650 0.650 n n 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 E 6 Y �Jf 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 qlazinq, cir low-e , 12E-Osw ' 2 glazing, cir low a 13A-4ocs 2 glazing, clr low-e 0.650 0.650 0.650 0.650 0.068 0.650 0.143 0.650 n n n n a a a a 0.00 0.00, 0.00 0.00 1.90 18.20 0.00 0.00 0.00 0.00 0.00 0.00 1.18 33.77 0.00 0.00 0 0 0 0 130 0 0 0 0 0 0 0 . 130 0 0 0 0 0 0 0 248 0 0 0 0 0 0 0 154 0. 0 0 0 0 0 0 162 0 0 0 0 0 0 0 162 0 0 0 0 0 0 0 308 0 0 0 0 0 0 0 192 0 0 0 G r 2 glazing, clr low-e 12E-0sw 2 glazing; cir low-e 0.650 0.068 0.650 a s . s 0.00 1.90 18.20 0.00 1:18 14.99 0 74 0. 0 ; ' 66 0 0 126 0 0 79 0 0 117 0 0 117 0 0 223 0 0 138 0 i 2 glazing, clr lower •2 glazing; clr.low-e 0.650 0.650 :., s s 18.20 18.20 14.99 14.99 • 8 0 ' 8 0 146, 0 120 0. '. 0 0 0 0 0 0 0 0 W! VI/ --�G C F P 2 glazing, Gr low-e 2 glazing, cir low-e 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, clr low-e 11GO 12E-0sw . 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low a 2 glazing, cir low-e 2 glazing, cir low-e 13A46cs 2 glazing; cir low-e 2 glazing, clr low- 16A-30td 22A tph ox6 o 0.650 0.143 0.650 0.650 0.650 0.650 0.650 0.650 0.540 ' 0.668 0.143 0.650 0.650 0.650 0,650 '0.143. 0.650 0.650 0.032 1.358 - s, ,* s s s s s s s s s w w w w w w dw nw ' nw - - 0.00 18.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.90 38.02 0.00 14.99 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.18 0.00 0.00 0.00 0.00 0.00 0.00.. 0.00 0.00 2.24 0.00 0" . 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. 0. 112 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0, 0- 0 112 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 160 0 ' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 251 0 � ' 0 0 0 0 0 0 0 0 0 0 36 0 0 0 0 0 0 0 0 486 0 0 0 0 0 0 0 0 0 0 0 36 0 0 0 0 0 0 0 0 486 0 0 0 0 0 0 0 0 0 0 0 69 0 0 0 0 0 0 0 0 435 0 0 0 0 0 0 0 0 0 0 0 43 0 0 0 0 0 0 0 0 1089 0 M C P 6 c�AED excursion 0 0 r Envelope loss/gain 620 603 1498 1749 12 a a) Infiltration b) Room ventilation 367 0 105 0 1001 0 287 0 13 Internal gains: Occupants @ 230 0 0 0 0 k Appliances/other 0 1900 Subtotal (lines 6 to 13) 987 709 2499 3936 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 49% 51% 0 0 0 987 485 0, 0 0 709 362. 49% 51% 0 0 234 2733 1344 0 0 211 4148 2120 TO, room load Air required (cfm) 1473 95 1071 49 4077 262 6267 288 CA to meet all Ed. wrightsoft- Right -Suite® Universal 2017 17.0.08 RSU08101 E:IDocumnets%Wrightsoft WACIGAMBINA RESIDENCE.rup Calc= MJ8 Front Door faces: S 2018-Mar-07 09:48:51 Page 20 A+- wrightsoft` Right-J® Worksheet Job: AHU 3 Date: Mar 07, 2018 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name THEATER HALL HALF BATH 2 3 Exposed wall Room height 4.0 ft 9.3 ft heat/cool 4.0 ft 9.3 ft heat/cool 4 5 Room dimensions Room area 4.0 x 14.0 ft 56.0 ftz 4.0 x 8.0 ft 32.0 ftz I T,y Construction number U-value (BtulVW °F) Or HTM (Btuh/ft2) Area (ft') or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12E-Osw 2 glazing, cU low-e 2 glazing, clr low-e 0.068 0.650 0.650 n n n 1.90 0.00 18.20 1.18 0.00 14.99 37 0 0 16 0 0 30 0 0 19 0 0 37 0 0 37 0 0 71 0 0 44 0 0 11 2 glazing, clr low-e 2 glazing, clr low-e 0.650 0.650 n n 0.00 18.20 0.00 14.99 0 21 0 0 0 388 0 320 0 0 0 0 0 0 0 0 13A-4ocs 2 glazing, clr low-e 2 glazing, cir low-e 0.143 0.650 0.650 n n n 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 0.650 0.650 n n 0.00 0.00 0.00 0.00 0 0 0 A 0 0 0 0 0 0 0 0 0 0 0 0 W I VI/ A 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 12E-Nw : 2 glazing, clr low-e 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 12E-0sw 2 glazing, clr low-e 0.650 0.650 0.650 0.650 0.068 0.650 0.143 0.650 0.650 0.068 0.650 n n n n a a a a a s s 0.00 0.00 0.00 0.00 1.90 18.20 0.00 0.00 0.00 1.90 18.20 0.00 0.00 0.00 0.00 1.18 33.77 0.00 0.00 0.00 1.18 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �--rG 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 13A-4ocs 2 glazing, clr low-e 2 glazing, or low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 11GO 112E-0sw 13A-4ocs 2 glazing, clr low- 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 13A-4ocs .' 2 glazing, clr low-e 2 glazing, -clr low-e 16A-30td 22A tph. 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.650 0.650 0.650 0.540 0.068 0.143 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.032 1.358 s s s s s s s s s s s s w w w w w w nw nw nw 18.20 18.20 0.00 18.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.90 38.02 14.99 14.99 0.00 14.99 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2.24 0:00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 56 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 56 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 125 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 32 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 32 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 29 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 72 0 f w I- C I F I I 6 c)'AED excursion 0 0 Envelope loss/gain 469 464 100 116 12 a) Infiltration b) Room ventilation 67 0 19 0 67 0 19 0 13 Internal gains: Occupants @ 230 0 0 0 0 R Appliances/other 0 200 Subtotal (lines 6 to 13) 535 483 166 335 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 49% 51% 0 0 -535 0 0 0 0 -483 0 0 49% 51% 0 0 134 300 148 0 0 121 456 233 Total room load Air required (cfm) 0 0 0 0 448 29 689 32 Calculations approved byACCA to meet all requirements of Manual J 8th Ed I� wrr9htsoft" 2018-Mar-07 09:48:51 ACCA � Right -Suite® Universal 2017 17.0.08 RSU08101 Page 21 !E:%Documnets\Wrightsoft WACIGAMBINA RESIDENCE.rup Calc = MJ8 Front Door faces: S P -- r rightsoft' E Right- l® Worksheet AHU 3 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Mar 07, 2018 By: 1 u Room name BRIDGE 2 3 4 5 Exposed wall Room height Fltoom dimensions Room area 0 ft 9.3 ft heat/cool 1.0 x 278.0 ft 278.0 ft2 I Ty Construction number Ll-value (Btuh/ft' °F) Or HTM (Btuh/ft2) Area (ft') or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross NlP/S Heat Cool 6 m p 12E-Osw . 2 glazing; cir lower 2 glazing, clr low-e 0.068 0.650 0.650 n n ri 1.90 0.00 18.20 1.18 0.00 14.99 , 0 , 0 . 0 0. 0 0 0 0 . 0 0- 0 0 ; .. ' 11 2 glazingl clr low-e 2 glazing, clr low-e 0.650 0.650 n n 0.00 18.20 0.00 , 14.99 . 0 , 0 . 0 0 0 - 0 0 0 ' P 13A-0ocs 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, clr low- 2 glazing, clr low-e 0.143 0.650 0.650 0.650 0.650 n . n n n n 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 B V Vtl w 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, clr low-e 1,2E-0sw: 2 glazing, clr low-e 13A-4ocs 2 glazing, clr low-e 2 glazing, cir low-e 12E-Osw 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing; cir low-e 2 glazing, cir low-e 13A flocs 2 glazing, cir lows 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 11 G 0 12E0sw 13A-4ocs 2 glazing, clr low-e 2 glazing, cir lows 2 glazing, clr low a 2 glazinq, cir low-e 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 16A-30td 22A-tph 0.650 0.650 0.650 0.650 0.068 0.650 0.143 0.650 0.650 0.068 . 0.650 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.650 0.650 0.650 0.540 0.068 0.143 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.032 1.358, n n n n a a a a a s s' s s s s s s s s s s s s w w w w w w - nw 'nw nw - - 0.00 0.00 0.00 0.00 1.90 18.20 0.00 0.00 0.00 1:90 18.20 18.20 18.20 0.00 18.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 6.00 0.90 38.02 0.00 0.00 0.00 0.00 1.18 33.77 0.00 0.00 0.00 1:18 14.99 14.99 14.99 ; - 0.00 14.99 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1:18 0.00 0.00 0.00 0.00 '0.00 : 0.00 0.00 : 0,00 2.24 0.00 0 0 0 0 0 0 0 0 0 0 0 : 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -:.,. 0 0 ` • ` 0 278 '- ' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 . 0 278 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 249 0 0 0 0 0 6 0 0 0 0 0 0 0 0 . 0 0- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 623 0 . . CVO/ -G P' d V P V� C G L h__G C F i 6 c) AED excursion O Envelope loss/gain 249 623 12 a)° Infiltration ti Room ventilation 0 0 0 0 13 Internal ryry gains: Occupants @ 230 0 0 p Appliances/other 2500 Subtotal (lines 6 to 13) 249 3123 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 49% 51% 0 0 105 354 174 0 0 103 3225 1648 Toltal Ai( room load required (cfm) 528 34 4874 224 ACCA to of -Ft-F wrightsoft" 2018-Mar-0709:48:51 RighlSuite® Universal 2017 17.0.08 RSU08101 Page 22 E:1Documnets\Wrightsoft WAC\GAMBINA RESIDENCE.rup Calc = MJ8 Front Door faces: S