HomeMy WebLinkAboutPERMIT WORKSHEETPERMIT NUMBER �, :,:::...... .... ><;:.: �:.. ,�
Installer -Tkomas �- S�ytvtih9s License# 2%}00�01�.) New Home [� Used Home El
Home installed to the Manufacturer's Installation Manual
Address of home ���%%� ��rf�-� ��, Home is installed In accordance with Rule _1.5-C
being installed _ _ _ _
Single wide [] Wind Zone II
Manufacturer Sky Lr N e Length x width tic x KT' r
Double wide [] I
NOTE., If home Is a single wide fill out one half of the blocking plan
If home Is a triple or quad wide sketch In remainder of home
I understand Lateral Arm Systems canr�flbe�u�sed on any home (new or used)
where the sidewall ties exceed 5 it 4 ire, 9Z�80 Eye
Typical pier spacing
lateral FCFSS
2' S-O
r,�� q,�y(M °Fcr. r71
Show locatlo 9tiof��ofit�1.udi'n i��n''`� Lateral Systems ,
onglludlna-----(use-darie-lln$s}tD�soirp ids�jlocatlons)-- --
- --- -- —
G' n C
U
marriage wall ploys wlthln T of and of home per Rule 1 sc
0
nsfallatlon Decal Il
Triple/Quad r Seri 111
Wind Zone III El
. a
PIER SPACING TABLE FOR USED HU&BI.
Load Footer
bearing size 16" x 16' 18 1/2' x 18 1/2' 20' x, 20' 22' x 22' 24' X 24" 6' x 26'
capacity (sq In) (256) (342) (400) (484)` (576)` (676)
Interpolated from Rule 1SC- 1 pier spacing table.
PIER PADS
1-beam pier pad size 1-7% x zS%2
Perimeter pier pad size dGx�s
Other pier pad sizes
(required by the mfg.)
Draw the approximate locations of marriage
wall openings 4 foot or greater. Use this
symbol to show the piers.
List all marriage wall openings greater than 4 foot
and their pier pad sizes below.
POPULAR PAD SIZES
ANCHORS
Opening Pier pad size
4�
4 It 5 It
ln17x2S' 1------> 1-7
FRAME TIES
-7 = 17x 25 "" 17xz�
within 2' of end of home
spaced at 5' 4" oc
TIEDOWN COMPONENTS
OTHER TIES
Longitudinal Stabilizing Device LSD
Number
S Ky t-► h e brei MG,
PERMIT WORKSHEET
gage 2 of 2
PERMIT NUMBER.
........
POCKET PENETROMETER TEST Site Preparation
The pocket penetrometer tests are rounded down to 150t)
or check -here to dedlare 1000 Ib. soil without testing.
x o x Ldo x :06
POCKET PENETROMETER TESTING METHOD
1. Test the perimeter of the home at 6 locations.
2. Take the reading at the depth of the Tooter.
3. Using 500 lb. increments, take the lowest
reading and round down to that increment.
X_t
TORQUE PROBE TEST
The results of the torque probe test is 30 0 inch pounds or check
here if you are declaring 5' anchors without testing — . A test
showing 275 inch pounds or less will require 5 foot anchors.
Note: A state approved lateral arm system is being used and 4 ft.
anchors are allowed at the sidewall locations. I understand 5 ft
an are required at all centerline tie points where the torque test
reading is 275 or less and where the mobile home manufacturer may
requires anchors with 4000 b holding capacity.
Installer's initials
ALL TESTS MUST BE PERFORMED BY A LICENSED INSTALLER
Installer Name
Date Testedoil
Connect electrical conductors between mu►I#i-wi,
source. This includes the bonding wire between
Connect all sewer drains to an existing sewer tap or septic tank. Pg. IYE?
Connect all potable water supply piping to an existing water meter, water tap, or other
independent water supply systems. Pq.
Debris and organic material removed t/e5
- -Water--drainage: Natural-- Swat- —Pad Othery
Fastening multi wide units
Floor: Type Fastener: B/9 Length: y*. Spacing: a G" o•C
Walls: Type Fastener: Length: Spacing:Y'
Roof: Type Fastener: 3L8 Length: Li Spacing: .2 Y" 6. c-
For used homes a min. 30 gauge, 8" wide, galvanized metal strip
will be centered over the peak of the roof and fastened with qalv.
roofing nails at 2" on center on both sides of the centerline.
GaskCtsweatherproofing requlrer entl
I understand a properly installed gasket is a requirement of all new and used
homes and that condensation, mold, meldew and buckled marriage walls are
a result of a poorly installed or no gasket being installed. I understand a strip
ofitape will -not -serve as a Bask_eT
Installer's initials 7
Type gasket Cen-�ev' Sed-L Installed:
pg., ad Between Floors Yes
Between Walls Yes tel
Bottom of ridgebeam Yes
_ Weatherproofing
The bottomboard will be repaired and/or taped. Yes pg. � 9
Siding on units is installed to manufacturer's specifications. Yesy
Fireplace chimney installed so as not to allow intrusion of rain water. Yes i-'
Miscellaneous
Skirting to be installed. Yes No
Dryer vent installed outside of skirting. Yes � N/A
Range downflow vent installed outside of skirting. Yes ✓ N/A
Drain lines supported at 4 foot intervals. Yes
Electrical crossovers protected. Yes
Other:
Installer verifies all information given with this permit worksheet
is accurate and true based on the
P9
e 15C-1 & 2
Installer Signature 277e%,y 7�� Date -17 Off,