HomeMy WebLinkAboutEVALUATION REPORT - HORIZONTAL SLIDERURNER ENGINEERING & CONSULTING, INC. i SCANNED BY St Lucie County 1239 Jabara Ave. North Port, FL 34288 Ph. 941-3 80-1574 FBPE C.O.A. #29779 Evaluation Report 871B April 18, 2015 i Product Description: Series 8200 PVC Horizontal Slider Window, Large Missile Impact (HVHZ), XO or OX 74"x63" unit size with design pressures of +/-60 psf (Fin or Flange window) Manufacturer: Custom Window Systems, Inc. 1900 SW 44`' Ave, Ocala, FL 34474 -nt of Compliance: This report evaluates the above -listed product per the requirements of FAC Approval Rule Chapter 61G20-3.005 (4). This product complies with the requirements of the 5t' (2014) Florida Building Code including the High Velocity Hurricane Zone. The product testing Is performed are outlined below. %, k k k y a k, a I I k Cechnical Documentation: 1) This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North Port, FL 2) Approval drawing CWS-871B, signed and sealed by Lucas A. Turner, P.E. 3) Test Reports NCTL-210-3887-1, -1A, -2, and -2A, by National Certified Testing Laboratories, Orlando, FL, signed and sealed by Gerard J. Ferrara, with testing performed: TAS 201, 202, 203 `94, ASTM E 1886 `02/04/05, ASTM E 1996 `04/06/09, and AAMA/WDMA/CSA 101/I.S.2/A440 `08 4) Supplemental Calculations to support CWS-871B, signed and sealed by Lucas A. Turner, P.E. I hstallation: Units must be installed according to approval document CWS-871B. Limitations of Use: This product: ` ` All I • May be used up to the sizes and daylight openings indicated in CWS-871B 0 Achieves design pressures of +/-60 psf • Is Large Missile impact resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • Requires Dupont Butacite PVB Interlayer per Miami -Dade N.O.A. 13-0129.27t • Requires Quanex (Mikron) white rigid PVC framing per Miami -Dade N.O.A. 12-1017.02t t I have evaluated the interlayer and framing materials in these Dupont and Quanex NOAs and find that they comply with the requirements of the 5 h Ed. (2014) Florida Building Code for use in this product. . . . . . Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. 1j111111/111/11 ..........010 �. No 56201 ..•�:�Pr . 0 .. Er sTA1 of : �� ` 4/18/2015 ,Al fi o Rlt, UX��.Lucas A. Turner, P.E. FL PE 458201 HORIZONTAL SLIDER - LARGE MISSILE IMPACT 641/4" MAX FLANGE TABLE OF CONTENTS GENERAL NOTES & ELEVATION: SECTION VIEWS & GLAZING DET EXTRUSIONS & B.O.M................... 75 114" MAX. OVERALL FLANGE WIDTH 74" MAX. UNIT WIDTH . j-33" GLASS DLO 0 GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED. WINDOW SYSTEP4S TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AND 1900 SW 44TH AVE. IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED OCALA, FLORIDA 34474 .IN ASTM E 1996 PER THE FBC. W WV.CWS.CC I 2. GLAZING OPTIONS: (SEE SHEET 2) "OX", "XO". 8200 PVC 3. CONFIGURATIONS: HORZ.SLIDER 4. DESIGN PRESSURE RATING: IMPACT -NEGATIVE DESIGN LOADS BASED ON, TESTED. PRESSUREAND GLASS TABLES ASTM E-1300-04: -POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE AND GLASS TABLES. ASTM E-1300-04. � a 5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED o o O Y w w 5.4 IN THE DESIGN OF THIS PRODUCT. SEE SHEET 5 FOR ANCHOR. DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ¢ m ANCHOR CALCULATIONS. 6: PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT U Z REQUIRED. 'THE IMPACT ROTARY LOCKS ARE INTENDED TO BE LEFT ' o w y Z UNLATCHED DURING NORMAL OPERATION OF THIS PRODUCT, BUT W MUST BE ENGAGED PRIOR TO EXPOSURE TO HURRICANE WINDS AND, w m FLYING DEBRIS. a ❑ ❑ )_ a 7. ALL FRAMES AND .VENTS FULLY WELDED. SMALL JOINT SEAM SEALANT U U USED AT FIXED MEETING RAIL AND HEAD/SILL. ❑a qx W' . U ❑ 8. SERIES / MODEL DESIGNATION HS-8200. CO Q O 9. THE DESIGNATION XAND,O STAND FOR THE FOLLOWING: „tit1[goofy = OPERABLE SASH, 0 = FIXED SASH`PNDEN� 'T:�',�'�' 10.S CTIONCALLOUTSAPPLYTOALLELEVATIONSIN'A'SIMILAR +X VP LOCATION. ++ wt ":�13? No 58201 11. EXTERNAL WEEP SLOT 114" x 1" LOCATED 4" FROM BOTH ENDS. r9 • STATE OF 'IfJ MAX. UNIT SIZE DESIGN PRESSURE RATING IMPACT RATING 74"-x,63"----- +/=-60-P-SF- -LARGE MISSILE IMPACT v00; ' fONA%- � +� 4/11/2015 LUCAS A. TURNER, P.E. FL PE #,56201 1239 JABARA AVE. NORTH PORT,'FL 34288 PH. 941-38Q-1574 SHEET DESCRIPTION: GENERALNOTES AND, ELEVATIONS DRAWN BY: DATE: ADE J0/16/13 DWG#: REV.: CWS487_1 B -- --- SCALE: s SHEET 1:1;'s •'1; OF 5. INTERIOR SECTION A -A II SECTION C-C - - - --- — -- - -AL-TERNATE-FIN-FRAME--- INTERIOR SECTION B-B NOTE: FIXED LITE AT HEAD AND SILL IS SIMILAR. HEAD IMPACT HOOK (TYP.) MIDSPAN OF SASH (ITEMS 35& 36) JAMB SWEEP LOCK LOCATIONS 1:20 SWEEP LOCK (TYP.) ONLY ENGAGED PRIOR TO HURRICANE FORCE WIN LOCATED AT THIRD POINTS (ITEM 27) GLASS TYPE A WINDOW SYSTEMS &-U, IzI 1900 SW 44TH AVE. OCALA. FLORIDA W74 WWW.CWS.CC . 8200 PVC: . HORZ. SLIDER IMPACT O O ❑ W Q :m rn D Z N W Z W W O a a_ o . w a z a 4i .o JVERP'LL No -58201 '�� 4NNEALEDorTEMPERED AIRSPACE z _ �9= STATE !OF : 4r: MINEALED i���,�5�.......... O R 10 `�N . �S fN A DUPONT PVB INTERLAYER . 4NNEALED 4/11/2015 FECT GLAZE "H" FLEX 552 " LUCAS A. TURNER, P.E: FL PE # 58' Z 1239 JABARA AVE. NORTH PORT,;FL 34288. PH.941-380-1574:' SHEET DESCRIPTION: 1/2" GLASS;BRE ' SECTION:VIEWS AND GLAZING DETAIL DRAWN BY: DATE: ADE 10/10/13 DWG REV.: . :CWS-871. B �— - SCALE SHEET 1:2 2OF5 PARTS LIST rEM PART# DESCRIPTION 1 H-1497 Reinf. Sash Meet. Rail 2 H-1699 Reinf. S.B.R./S.S.R, 3 H-1836 ' Meet. Rail, Fxd. 4 H-6052 Sash Tap/Bot. Rail 5 H-6048 Main Fr., SH, w/ Fin., PVC 6 H-6050 Sash Meet. Rail, PVC 7 H-6051 Sash Side Rail, PVC 8 H-6049. Main Fr., SH, w/Fig:, PVC 9 P-3029 Screen Pull Tab 10 P-3033 Screen Spring, SS 11 P-3113 Screw Support, PVC 12 P-3218 Screen Frame 13 P-3228 Screen Spline, .155 Die., Blk. 14 P-4754 Screen Frame Comer Key 15 P3342 Seam Sealer, SM-5504 16 P-3352 Set. Blk., 85 Dur., 1/8" x 5/8" x 2" 17 P-3429 Wstp., 0.270 x .187 back FinSeal, 18 P-3539 1#8 x 3/4" Square TEK 2 Zinc 19 P-4730 #8 x 1/2" Truss PH TEK 2 Zinc 20 P-3752 Cap Plug, 1/2" Hole 21 P-3783 or P-5250 Spring Lock, Impact, PVC 22 P-4779 Roller, Tandem 23 P-4051 #8 x 1 114 Ph FH TEK, Wht. 24 P-4069 Keeper, Impact, PVC 25 P-4479 lWeep Coaerw/ Flap 26 P-4638 #8 x 2 112 Ph Truss SMS 27 P-4958 Rotary Lock 28 P4952 Keeper, Rotary Lock 29 P-4959 Wstp., 0.420 x .187 back FinSeal, 30 P-4633 Barrel Fastener 31 S-1112 Reinforcement, Head 32 S-1498 Reinf. S.B.R./S.S.R, 34 S-1776 Roller Track 35 S-1999 Frame Hook, Head, Impact 36 S-2000 Panel Catch, Head, Impact 37 S-6005 Anti Lift 38 S-6013 Scm. Adapt., w/ Nib, PVC 39 S-6014 Scm. Adapt., PVC 40 S-6063 Fixed Rail Cover 41 S-6064 Glazing Bead 42 GLASS SEE SHEET 2 43 Purfect Glaze "H". SikaFlex 552 VENDOR MATERIAL 3118" -1 (� e 2 11/16" "��� 3 oQoQ 1/16" �� r PVC FRAME FLANGE16049 Keymark Alum Keymark Alum Keymark Alum Mikron PVC Mikron PVC Mikron PVC Mikron PVC Mikron PVC 3 118" —� � � � � 3 .. 5 9/16" �o� 2 1/8" FIXED RAIL -1836 Summit PVC FRAME FIN-6048 Hurley 1 15/16' 1 3116" Team Plastic Rubber I—23116^ 9116• Allmetal RollFormE 7 6 4 40 Dapa 1518' 1518" q 15I18" q 15116• Allmetal Nylon 1/16° I q 1/16" I 1/16• vts" Schnee Silicone L LL FrankLowe Rubber PVC SASH MTG. RAIL-6050 PVC SASH SIDE RAIL-6051 PVC SASH TOP/BTM RAIL-6052 PVC FIXED RAIL COVER -6063 Ultrafab Fastenal Steel Fastenal Steel M&M Nylon Interlock M&M Nylon Fastenal Steel Interlock Ajax Steel Sullivan Zinc Sullivan Zinc Ultmfab Fastenal Steel Keymark Alum Keymark Alum Keymark Alum Keymark Alum Keymark Alum Mikron PVC Mikron PVC Mikron PVC Mikron PVC Mikron PVC CARDINAL GLASS Henkel / Sika Silicone rO 3/16" 0 ��.. 6".� 1 5116" 35 7/8" 1/16" PLAN VIEW-1999 HEAD ACT HOOK -1999 0 3116" O �518"f~ T— 36 S/f 1/16" PLAN VIEW-2000. PANEL IMPACT CATCH - 2000 �3/16° - 3•1/2" 11 SCREW SUPPORT-3113' LINE -ITEMS NOT USED: - NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. 33 5/e" t•�- I—y -1T�"--I-I �� 1 i III iris" SASH MTG. RAIL-1497 3116•-0 314" r- T- 3 � 1116" S.B.RJS.S.R.- 1498 v4 4, 7/8' PVC GBEAD-6064 1/2"� jam, v8•y -►ii- I 36 1116" PVC SCREEN CATCH -6p13 39 1/16' PVC SCREEN SUPPORT -6014 CORNER CONSTRUCTION CORNER WELD (ALL SIDES) 1:8 15 6 FIXED MEETING RAIL SCREWED TOGETHER WITH OUTERFRAME 1:8 314" 2 15/16" L0 1/16" SASH REINF. - 1699 34 1/16" ROLLER TRACK -1776 r 7/8" 1 9/11 I I 31 . 1/16" GLAZE BEAD -1112 318" 1 I� 1 5/16° �71"I 3 L iris^ PVC ANTI -LIFT, - 6005 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC . 8200 PVC HORZ.iSLIDER IMPACT O N Q 0 0 ❑ U Z m F: LD oN y N W Z L> wwof Lu U JP5-��C 6 N S`:G�Q�•� I' No 58201 "11w STATE IOF "i4f zz 4/11/2015 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, jFL 34288- PH.941-380-1574 SOM AND EXl ^ y^10/10/13 ADE IG 0: REV.: CWS-871 B ALE: SHEET 1:2 3OF5 wIN®ow.sYsre�ss 12 1/2" MAX. O.C. (TYP.) '1900 SW 44THAVE. 4' MAX. 8- MAX. O.C. (TYP.) 6' MAX (TYP•) 13 P SEE NOTE 2 E NOTE 2 OCALA, FLORIDA 34474 W W W.CWS.CC . 6" MAX (TYP.)).. 4" MAX (TYP.) r INSTALLATION 82�� PUC ANCHOR GYP.) , 1 HORZ. SLIDERINSTALLATION ' 1 ' ' I ' ANCHOR(TYP.) IMPACT I I B. MAX O.C. (TYP.)17' In v 0TYP.) C. I O 1 0 (MAX I O I I I O I `/ I II I I x I Y W W I ¢ m I M y Z Q I , I 1 I I C O S2 I I 1 I '.� W t O . jjI L------- m w d - -- -- -- -- -- -- -- -- F- O U ANCHOR LAYOUT -(FLANGE) ANCHOR LAYOUT -(FIN) U o opQ z . c11 No 58201 p . NOTES:' STATE .. 'PLC O 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD. 4i�S; 2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALL Z 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 5. 4/11/2015 , LUCAS A. TURNER, P.E. FL PE # 58201 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. 1239 JABARA AVE. 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SU13ST'RATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT,,FL 34288 PH. 941-380-1574' SPECIFIED IN TABLE 1, SHEET 5. SHEET DESCRIPTION: I 6..ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE. ANCHOR SCHEDULE AND INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REOURE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE -THE USE OF IX BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. NOTES 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR MASONRY, 1" FOR WOOD AND METAL. DRAWN BY: DATE: ADE 10/10/13 8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. DWG a: REV.: SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 5. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-871 B 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCALE: SHEET FMA/AAMQ 100(FIN WINDOWS);;FMA/AAMA 200(FLANGE WINDOWS), FMANVDMA 250(BOX WINDOWS), FMA/AAMAANDMA 300(EXTERIOR DOORS) 1:20 4 OF-5 MIN.EMBEDMENT (( jJj](�4j/j�•I%f/�{ TYPICAL HEAD ANCHORAGE SEE TABLE 1 SUBSTRATEV(SiSAyC4W/ BY OTHERS WINDOW SYSTEMS MIN. EDGE DIST. 114" MAX SHIM SEE TABLE 1 MIN. EDGE DIST SUBSTRATE 1900 SW 44TH AVE. SEE TABLE 1 SEE TABLE 1 BY OTHERS . DIST. SUBSTRATE BY OTHERS 114" MAX. SHIM �SEE TABLE 1 W FLORIDA 34474 W W. SEE TABLE 1 MINEDGE DIST MIN. EMBEDMENT �0 SEE TABLE 1 PERIMETER SEALANT SEE TABLE 1 Q O PVC BY INSTALLER INSTALLATION ANCHOR 820 Q HORSLIDER INSIDE AND OUT SEE TABLE 1 j� �j0 LI 0 MIN. EMBEDMENT SEALANT BEHIND �SEE TA13LE 1 IMPACT FLANGE BY INSTALLER 1/4' MAX SHIM Q � II1I BYRINSTALLERSEALANT o o O PERIMETER SEALANT BY ee INSIDE AND OUT INSTALLER a INSIDE AND OUT Y W INSTALLATION ANCHOR � 2 INSTALLATION ANCHOR SEALANT BEHIND SEE TABLE 1 W Q m FLANGE BY INSTALLER SEALANT BEHIND co SEE TABLE 1 FIN BY INSTALLER 0 Z �g1 HORIZONTAL SECTION r_F*� HORIZON7ALSECTION u°O. O 5 TYPICAL JAMB ANCHORAGE 5 TYPICAL FIN ANCHORAGE p W 1/4' MAX SHIM SEALANT BEHIND oQ q FLANGEjBY INSTALLER �7 1 u PERIMETER SEALANT MIN. EMBEDMEN' BY INSTALLER SEE TABLE INSIDE AND OUT SUBSTRATE BY OTHERS SEE TABLE 1 - MIN. EDGE DIST. SEE TABLE 1 VERTICAL TYPICAL SILL ANCHORAGE TABLE:1:APPROVED INSTALLATION FASTENERS FRAME TYPE SUBSTRATE TYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE DIST. FLANGE CONCRETE (2.0 KSI MIN.) 3/16' ITW TAPCON 1-1/2" 1-118" FLANGE HOLLOW OR GROUT -FILLED CMU (117 PCF MIN.) 3/16" ITW` TAPCON 1" 2" FLANGE CONCRETE (2.85 KSI MIN.) 3/16" ELCO ULTRACON FLANGE GROUT -FILLED CMU (ASTM C-90) 3/16" ELCO ULTRACON 1-114" 2-1/2" FLANGE 2X MIN. SOUTHERN PINE (G=0.55) 3/16" RW TAPCON OR ELCO ULTRACON 13/8" 7/8" FLANGE 2X MIN. SOUTHERN PINE (G=0.55) #10 WOOD SCREW 13/8" 7/8" FLANGE 16 GAUGE (0.060") MIN. STEEL STUD (33 KSI YIELD MIN) #10-16 HILTI KWIK-FLEXOR ITW TEKS SELF -DRILLING SCREW FULL THREAD THRU 0.060" 7/16" FLANGE 1/8' ALUM. (6063-T5 MIN.) OR 1/8" STEEL_(33-KSI MIN.) __ _ ___ #10 GRADE 5 SELF -TAPPING / DRILLING W SCRE_ _ FULL THREAD _ THRU 0 125"_ 7116" FIN 2X MIN. SOUTHERN PINE (G=0.55) #8 WOOD SCREW 1-11T 1/2" HEAD AND SILL SIMILAR FOR FIN INSTALLATION iZ w Z IL o 0 D- 12 O U y.. a.44 U � m Q O Z.. ti� .Pr1D RE 4V ..0 No 5S201 -�-P 4� ID= STATE OF 4U i 4/11/2015 a� LUCAS A. TURNER, P.E. FL PE # 58201 PERIMETER SEALANT. 1239 JABARA AVE. BY INSTALLER INSIDE AND OUr NORTH PORT, FL 34288 PH: 941-380''-1574 ' HORIZONTAL SECTION �,S BOX FRAME INSTALLATION SHEET DESCRIPTION: HEADBAND SILL SIMILAR FOR BOX INSTALLATION INSTALLATION{ DETAILS FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE, UP TO AND INCLUDING A BOX -FRAME APPLICATION IS ACCEPTABLE PROVIDED: DRAWN BY: DATE ADE 10/10/93 MIN. 1/4" FILLET OF CONSTRUCTION -GRADE ADHESIVE CAULK IS APPLIED DWG#: REV.: INSIDE AND OUT, FULL PERIMETER, BY INSTALLER. CWS-871 B --PRODUCT.ANCHORAGE-IS-IN.A000RDANCE-WITH-REQUIREMENTS-AS- — SHOWN FOR FLANGE WINDOWS. SCALE: SHEET 1:2 5OF5