Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM 1100A=.08 I FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A Project Name: Street: City,, State, Owner_ Design Lotion: Westhday Addition Builder Name. Heritage Contracting Services, 105 s Cardinal Place Permit Office: St Lucie Zip: Fort Pierce , Ft, Permit Number Jospeh Westberry Jurisdiction: 661100 FL, ST LUCII CO INTL 1. New construction or existing New (From Plans) 9. Wall Types(1048:0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int insul, Exterior R=4.0 1048.00 fiz b. N/A R= ft2 3. Number Zf units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 Is worst 5. this a case? No 10. Ceiling Types (1409.0 sgft.) Insulation Area 6. Conditioned floor area (ft?) 1357 a. Under Attic (Vented) R=30.0 1357.00 ft2 I b. Knee Wall (Vented) R=19.0 52.00 ft2 7. Windows(89.1 sgfL) Description Area c. N/A R= ft2 a. U-Factor. Sgl, U=0.95 69.13 ii2 SHGC.� SHGC=0.55 11.. Ducts b. Y-Factor. Sgl, U=OM 20.00 ft2 a. Sup: Attic Ret: Interior AH: Interior Sup. R= 6, 250 ft2 5HGC. SHGC=0.55 12. Cooling systems c. U-Factor. N/A ft2 a. Central Unit Cap: 28.6 kBtu/hr SHGC! SEER: 14.2 d. UmFactior. WA SHGCI 13. Heating systems a. Electric Heat Pump Cap: 28.6 kBtu/hr e. U-Factor. WA ft? SHGC: HSPF:8:5• 14. Hot water systems 8. Floor Types (1357.0 sgfL) Insulation Area i a. Slab Edge Insulation R=Q.O 1357.00 ft2 a: Electric Cap: 50 gallons -On -Grade EF: 0.95 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 15.. Credits CF, Pstat GlasslFloor Area: 0.066 Total As -Built Modified Loads: 26.69 PASS Total Baseline Loads: 31.68 I hereby certify that the plans and specifications covered by this calculation are in comp an with the Floridaf�ergy Code. 1 �7 PREPARED BY' DATE: I hereby certify that this building, as desi ed, is in compliance with the Flo I'da Ene jde OWNER/AGENT: V� DATE: /( r Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes, E ;ME BUILDING OFFICIAL: DATE: 7/18/2011 12:20 PM EnergyGauge® USA - FlaRes2008 0 A. L+ %J) r. :Page 1 of 5 PROJECT Title: Westherry Addition Bedrooms: 3 Adress Type, Street Address Building Type: FLAsBuilt Conditioned Area: 1357 Lot # Owner. Jospeh Westberry Total Stories: I 13lock/SubDivislon: # of Units:, I Worst Case: No PlatBpok: Builder Name: Heritage Contracting Services Rotate Angle: 0 Street 105 s Cardinal Place Permit Office: St Lucie Cross Ventilation: No County: St. Lucie Jurisd c.tion: 661100 Whole House ran: No City, State, Zip: Fort Pierce, Family Type: Single-family Fl, New/Exist! ng: New (From Plans) I Cdrzirnent: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Tamp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, ST -LUCIE CCLINTL FL ST LUCIE CO INTL 2 39 90 75 70 722 58 Medium FLOORS # Floor Type Perimeter R-Value - --------- Area Mile Wood Carpet I I Slab-On-Grade'Edge Insulatio 120ft 0 1357 f12 0 0 1 ROOF .. . ...... . Roof Gable Roof Solar Deck # Type Materials Area Area Color Absor. Tested Insul. Pitch Gable or Shed -Composition shingles 1619 f12 340 ft2 Medium 0.9 N 0 26.6 deg ATTIC TYPO Ventilation Vent Ratio (I in) Area RBS IRCC Full attic Vented 300 1357 ft2 N N CEILING # Ceiling Type R-Value Area Framing Frac Truss Type I Knee Wall (Vented) 19 52 ft2 0.1 Wood 2 Under Attic (Vented) 30 1357 iF 0.1 Wood WALLS Omt Adjacent To Wall Type R�021ue Area Sheathing R­Value Framing Solar Fraction Absor. 11 N Exteiior Concrete Block - Int Insul 4 208 ft2 0 0 0.8 2' E Exterior Concrete Block - Int Insul 4 120112 D 0 0.8 3, S Exterior Concrete Block - Int Insul 4 208 fie 0 0 0.8 41 W Exterior Concrete Block - Int Insul 4 512 ft2 0 0 0.8 1 7/1812011 12:20 PM DOORS # Omt Door Type Storms U Value Area 1 N Insulated None 0.4 18.66666 WINDOWS Orientation shown is the entered, asBuilt orientation. . / ■ 1f #1 Overhang Ornt Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation Int Shade Screening 1 i 21 3 4 N Metal Single (Tinted) Yes 0.95 0.55 N 16 ft2 0 ft 0 in 0 ft 0 in HERS 2006 S Metal Single (Tinted) Yes 0.95 0.55 N 31.8 ft2 0 ft 0 in 0 ft 0 in HERS 2006 W Metal Single (Clear) Yes 0.95 0.55 N 20 ft2 0 ft 0 in 0 ft 0 in HERS 2006 W Metal Single (Tinted) Yes 0.95 0.55 N 21.33333 0 ft 0.in 0 ft 0 in HERS 2006 None None None None INFILTRATION & VENTING / V Method — Forced Ventilation — Run rime SLA CFM 50 ACH 50 ELA EgLA Supply CFM Exhaust CFM Fraction Fan Watts Default 0.00036 1281 7.08 70.3 132.3 0 cfrn 0 cfm 0 0 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Ducts 1 _ Central Unit None SEER: 14.2 28.6 :kBtu/hr cfrn 0.7 sys#1. HEATING SYSTEM # System Type Subtype Efficiency Capacity Duds 1 Electric Heat Pump None HSPF: 8.5 28.6 kBtu/fir sys#1 HOT WATER SYSTEM - System Type EF Cap Use SetPnt Conservation 1 Electric 0.95 50 gat 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System, Model # Collector Model # Area Volume FEF None None ft2 DUCTS _... _..... / V # — Supply — — Return— Air Percent Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF 1 Attic 6 250 fe Interior 50 ft2 Default Leakage Interior (Default) (Default) 1 7/18/2011 12:20 PM 1 run r,..n-.2nno TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Heating Jan W Feb Feb Mar 0Mar Apr Apr IA May May 0 Jun Jun Jul Jul Aug Aug Sep Set Oct 0 Oct Nov Nov Dec Dec N Ventin Jan Feb Mar pr l�J May Jun Jul Aug X X Se Oct Nov Dec Thermostat Schedule: HERS 2.006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling jvviH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68... 66...... 66 66. .. 7f1812011 12 20 PM Fnom%d'-.o sl F ICA _ ClaDnn9flnQ FORM 110GA-08 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 105 s Cardinal Place PERMIT #: Fort Pierce, FI, " INFILT.R.A -11ON REDUCTION COMPLIANCE CHECKLIST CIOMPONENTS SECTION REOUIREMENTS FOR EACH PRACTICE CHECK Exterior Wind s & Doors N1106.AB.1.1 Maximum:.3 cfrn/s .ft. window area; .5 clim/s .ft. door area. Exterio I & Adj: cent Walls N1106.AB.1.2 Caulk, gasket, weatherstrip or seal between:. windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to;. the foundation to the top `late. Floors N1106,ABA.2 Perietrations/openings> 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier Is installed that is sealed to the perimeter, penetrations and seams. Ceiling N1106.AB.1.2 n Between- walls & ceilings; penetrations of ceiling plane to top floor; . around shafts, chases, soffits, chimneys, cabinets sealed'to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is seated at the perimeter, at penetrations and seams. Recessed Lighiing Fixtures N1106.AB.1.2 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC with < 2.0 cfm from conditioned space, tested. Mufti-sto "Houses N1106.AB:1.2 Air barrier on perimeter of floor cavity between floors. Additional Infilt on refits N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have: combustion air. "'OTHER PRES 4 RIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENT SECTION REQUIREMENTS CHECK Water kleaters N1112AB.3 Comply with efficiency requirements in Table N1112.ABC.3 Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap re uired. Swimming Pool & Spas N1112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Heat pump pool heaters shall have a minimum COP of 4.0. Shower eads N1112.AB.2.4 Water flow must berestricted to ;no more than 2.5 gallons per minrite at 80 PSI& Air Distribution Systems N1110.A. B All ducts, fittings, mechanical equipment and plenum chambers shalt be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section Rill ' Ducts in unconditioned attics: R-6 min. insulation. HVAC C I britrols N1107 A6 2 Separate readily accessible manual or automatic thermostat for each system. Insulation N1104 AB 14.si Ceilings-Min. R-19. Common walls=frame R-11 or CBS R-3 both N1102 B 1.1 _ des. Common ceiling & floors R-11. 7/18r2011 12:20 PM GnemvGm,wef6l I.IQ/1 r1..6....onne .. ........... ESTIMATED ENERGY PERFORMANCE INDEX* = 84 • The lower the EnergyPerformance. Index, the more efficient the home. 105 s Cardinal Place, Fort Pierce, FI, $ . New construction in or axist g New (From Plans) 9. Wall Types Insulation Area a. Concrete Block - Int:lnsul, Exterior R=4.0 1048.00 W 2. Single farri11 or multiple family Single-family b. N/A R= �. Number o� u its, if multiple family 1 c. NIA R=' 4. Number of rooms 3 d. N/A R= S. Is this a wo case? No 10. Ceiling Types Insulation Area 6. Condftloned floor area (fts) 1357 a. Under Attic (Vented) R=30.0 1357 00112 b. Knee Wall (Vented) R=19.0 52.00 Its 7. Windows L Description Area c, N/A R= fts a. U-Factor. Sgl, W=U.95 69.13 W 11. Ducts SHGCGQ: SH.GC=0.55 Sup: Attic Ret: Interior AH: Interior Sup. W 6, 250 ft2 b. Uc r_ Sgl, U=0.95 20.00 Wa.. SHGC: SHGC=0.55 12. Cooling systems C. U-Factor NIA fts a. Central Unit Cap:28.6 kBttdht SHGC: SEER: 14.2 d. U-Factor WA 13. Heating systems SHGC: a. Electric Heat Pump Cap 28.6 kBtu/hr e. U-Factor.. WA ft HSPF:8.6 SHGC: 14. Hot water systems 8. Floor Typk Insulation Area a. Electric Cap: 50 gallons a. Slab-0n rade Edge Insulation R=0.0 1357.00 fF Ef: 0.95 b. NIA R= 10 b. Conservation features c. NIA R= fts None 15. Credits CF, Pstat I certify that Construction in this home based on in: Builder Sign Address of I` home has complied with the Florida Energy Efficiency Code for Building )ugh the above energy saving features which. will be installed (or exceeded) ke final inspection. Otherwise, a new EPL Display Cana will be completed ad Cod erempliant fea /2 Date: Oi• Home: r%S $. t!'� �cin� I L City/FL Zip:& Pace �4( *Note: T 'e home's estimated Energy Performance Index is only available through the EnergyGauge USA = FlaRes20 8 computer program. This is not a. Building Energy Rating. If your Index is below 100, your home may yual' for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at (321) 6381492 or see the Energy Gauge web site at energygauge.com for information and a list. of certified Raters. F _r information about Florida's Energy Efficiency Code for Building Construction, contact the Depart me� t of Community Affairs at (000) 487A 824. **Label re luired by Section 13-104.4.5 of the Florida Building Code, Building, or Section 132.1.1 of Appendix G of the Florida Building Code, Residential, if not DEFAULT. EnergyGauge® USA - FlaRes20Q8 I UIV F