Loading...
HomeMy WebLinkAboutLETTER WITH RESPONSES TO REVIEW COMMENTS - 12-21-15Joseph P. McCarty, Architect, Inc. 960 East Osceola Street Stuart, Florida, 34994 772-287-6735 fax:772-287-4618 DPR Registration Number 9639 December 21, 2015 Planning and Development Services Bi ilding & Code Regulation Services 2300 Virginia Avenue Fort Pierce, FL 34982 Re: 0 Dyer Road Permit #1510-0005 SCANNED BY St Lucie County RECEIVED DEC 2 9 2015 As follows is response to plan review comments: 1)1 The energy performance criteria for windows is as follows: SH5500 has a OF of 0.3300 and SHGC of 0.2200, the AW5540 has a OF of 0.3200 and SHGC of 0.1800. lam attaching the order from Manning Building supplies that references these numbers. I could not obtain the actual NFRC certificate. I was told by Manning Building that when the windows are delivered they will have stickers attached to the windows and doors with these values. The Therma-tru doors have a U factor of .32 and a SHGC of .29, these numbers will again be attached to the doors for job -site inspection, or can be verified at the Therma-tru web site. 2){ Flame spread and smoked developed index for the insulation has been put on the plans. 3)� Weathering area is indicated on plans as "negligible" per 301.2(3) 4)1 Termite infestation area is indicated on plans as "very heavy" per 301.2(6) , 5)1 Plans now indicate that wall and ceiling finishes shall have a flame -spread classification Iof not greater than 200. Wall and ceiling finishes shall have a smoke -developed index_ of not greater than 450. All wall and ceiling finishes are gypsum board. 6) Plans now indicate that flame spread for Icynene insulation is 25 or less, smoke developed index of 450 or less. The fiberglass batt insulation has a flame spread of 25 and smoke developed index of 50. 7), The window installation detail on sheet 1 has been revised to indicate fin -frame windows with integral flashing. 8), Bath #2 door has been revised to 2'-8" I 9) The elevations show piers and open space between the piers. This open space has been labeled on the plans. 10) The area under the house is open. (see 7) 11) ICC report on foam insulation, is attached. 12) Roof sheathing and nailing is specified on Sheet 5 13) Two copies of Hardie Board product approval are attached. 14) Wall sheathing and nailing are indicated on sheet 1. 15) Sheet 3 has been revised to indicate 3000 PSI compressive strength on all concrete. 16 Sheet 1 shows floor sheathing as3/4" T&G plywood. 10d nails 6" on center has been noted on detail. 17) Hand written notes have been removed from plans. � I J Joseph P. McCarty i OF g �N P. Q