Loading...
HomeMy WebLinkAboutREVIEW COMMENTS - 1cow Planning & Development Services Building rl<Code Regulation Division. 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462-6"3 Address: 0 Dyer Rd City / State / Zip: Port St Lucie, FI 34952 Parcel #: 3414-501-1412-200/8 REVIEW COMMENTS Page 1 Owner(s): Larry Seegott / Leslie D Trudeau Jurisdiction: SAINT LUCIE COUNTY Zoning: RM-5 Lot#: 12 APPLICATION INFORMATION I Permit Number: 1510-0005 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) I I CONTRACTOR INFORMATION Contractor; Name: I Business Name: Business Addr: City / Statej Zip: I REVIEWS AND COMMENTS Review Tvpelj Status i ADDRESSING ASSIGNMENT COMPLETE Block: 2 Automatic Sprinkler System? No Fax Number: Email: 000, Reviewed By Date Started Date Completed Date Released Lydia Galbraith 10/2/2015 10/5/2015 10/5/2015 Comment: DOCUMENTS MISSING PENDING Deanna Givens 10/1/2015 10/1/2015 Comment: NOTICE OF COMMENCEMENT 10/1/2015 Comment: VEG PERMIT SENT TO ERD 10/2/2015 Comment: A COPY OF THE PAID UTILITY SERVICE RECEIPT FOR ELECTRIC SERVICE OR A LETTER FROM THE ELECTRICAL UTILITY PROVIDER THAT ELECTRIC WILL BE AVAILABLE TO THE LOCATION. ENVIRONMENTAL REVIEW PENDING i Comment: FRONT COUNTER REVIEW COMPLETE Deanna Givens 10/1/2015 10/1/2015 10/1/2015 Comment: PLANS EXAMINER REVIEW INCOMPLETE William Durden .1012612015 CommentA:} PLEASE SUBMIT THEENET� RFOMANCE SHEETS OR SUBMIT A THE NFRC FENSTRATION 10/26/2015 Cv MANUFACTURE CERTIFICATE FOR THE U-FACTOR AND THE SHGC SHOWING COMPLIANCE WITH CHAPTER 4 SECTION 402.1.1 OF THE 2014 ENERGY CODE FIFTH EDITION. Comment: ' PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND t� 10/26/2015 APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE 10/26/2015 Comment: feo'_- PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE 10/26/2015 Comment: \ • PLEASE ADD TO THE PLANS THE CLIMATIC AND GEOGRAPHIC DESIGN CRIERIA WEATHERING AND TERMITE AREA IN ACCORDANCE WITH TABLE 301.2.(1) I Planning A Development Services, Building & Code Regulation DivisioiY 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462.6443 I .. REVIEW COMMENTS Page 2 10/26/2015 Comment: ,nl • PLEASE SHOW FLAME SPREAD INDEX AND SMOKE DEVELOPED INDEX FOR WALL AND CEILING FINISHES { IN ACCORDANCE WITH SECTION 302.9 OF THE 2014 FLORIDA RESIDENTIAL CODE 10/26/2015 Comment: • PLEASE SHOW THE FLAME SPREAD AND SMOKE DEVELOPED INDEX FOR THE INSULATION AS REQUIRED IN SECTION 302.10 OF THE 2014 FLORIDA RESIDENTIAL CODE Comment: • SHOW FLASHING DETAIL ON PLANS FOR ALL EXTERIOR WINDOWS AND DOORS. SEE SECTION R612.10 10/26/2015 FLASHING, SEALANTS, AND WEATHER STRIPPING, AND R703.8 FLASHING OF THE 2014 FLORIDA RESIDENTAL BUILDING CODE. i Comment: • ALL NEW SINGLE FAMILY HOMES SHALL PROVIDE AT LEAST ONE BATHROOM WITH A DOOR THAT HAS A 10/26/2015 CLEAR OPENING OF NO LESS THAN 29 WITH THE DOOR OPEN AT 90 DEGREES. SEE SECTION R320.1.1 OF THE 2014 RESIDENTAL BUILDING CODE FIFTH EDITION. 10/26/2015 Comment: ✓• ELEVATION DETAILS SHOW ENCLOSED UNDER FLOOR SPACE. PLEASE SHOW DETAIL OF HOW THIS IS TO BE INSTALLED. 10/26/2015 Comment: ELEVATION DETAILS SHOW ENCLOSED UNDER FLOOR SPACE. PLEASE SHOW DETAIL OF FOR THE VENTILATION FOR THE CRAWL SPACE. SEE SECTION R408 OF THE 2014 RESIDENTAL BUILDING CODE. Comment: • PLEASE FURNISH EITHER THE ICC EVALUATION REPORT OR A EVALUATION REPORT FROM A CERTIFIED 10/26/2015 TESTING LABORATORY THAT FOAM INSULATION MEETS THE REQUIRMENTS OF SECTION 316 OF THE 2014 FLORIDA RESIDENTIAL CODE Comment: 10/26/2615 f/' 'LEASE SHOW THE METHOD OF ATTACHMENT FOR THE ROOF SHEATHING INCLUDING THE FASTENER SIZE AND FASTNER SPACING IN ACCORDANCE WITH 803.2.3.1 OF THE 2014 FLORIDA RESIDENTIAL CODE 10/26/2015 Comment: V • PLEASE FURNISH TWO COPIES OF THE HARD] PRODUCT APPROVALS. 10/26/2015 Comment: • PLEASE FURNISH THE METHOD OF ATTACHMENT FOR THE WALL SHEATHING INCLUDING FASTENER /SIZE AND FASTENER SPACING PER 107.2.1 OF THE 2014 FLORIDA RESIDENTIAL CODE Comment: PLEASE FURNISH THE COMPRESSIVE STRENGHT OF THE CONCRETE BEING USED FOR THE FLOOR, 10/26/20.15 FOUNDATION, COLUMNS AND BEAMS BEING IN ACCORDANCE WITH 402.2 OF RTHE 2014 FLORIDA BUILDING CODE 10/26/2016 Comment: • PLEASE FURNISH THE METHOD OF ATTACHMENT FOR THE FLOOR SHEATHING INCLUDING FASTENER SIZE AND FASTENER SPACING PER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE Comment: • PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE 10/26/26,15 SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS ZONING REVIEW INCOMPLETE Lydia Galbraith 10/2/2015 10/2/2015 Comment: PLEASE PROVIDE A COPY OF THE HEALTH DEPARTMENT PERMIT FOR THE WELL. Comment: PLEASE INDICATE THE FOLLOWING INFORMATION ON THE SURVEY: - PROPOSED FINISHED FLOOR ELEVATION. MIN. REQUIRED IS 18" ABOVE CENTERLINE OF THE ADJACENT 10/2/201'5 ROAD (16.5') OR THE FLOOR HEIGHT REQUIRED FOR SEPTIC AND DRAINFIELD WHICHEVER IS GREATER. - FEMA FLOOD ZONE INFORMATION. - AT 2/16/12 ALL FEMA MAPS CHANGED IN ELEVATION NAVD AFTER THAT DATE ALL SURVEYS ARE REQUIRED TO BE IN NAVD OR HAVE A CONVERTION RATE FROM NGVD TO NAVD. 10/2/2015 Comment: PLEASE PROVIDE 2 CORRECTED SIGNED AND SEALED SURVEYS. THE SURVEYS DO NOT NEED TO BE RESTAMPED BY HEALTH DEP. 10/5/2015 Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS.