HomeMy WebLinkAboutREVIEW COMMENTS - 1cow
Planning & Development Services
Building rl<Code Regulation Division.
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462.2172 Fax:(772)462-6"3
Address: 0 Dyer Rd
City / State / Zip: Port St Lucie, FI 34952
Parcel #: 3414-501-1412-200/8
REVIEW COMMENTS
Page 1
Owner(s):
Larry Seegott / Leslie D Trudeau
Jurisdiction: SAINT LUCIE COUNTY
Zoning: RM-5 Lot#: 12
APPLICATION INFORMATION
I
Permit Number: 1510-0005 Stories:
Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS)
I
I
CONTRACTOR INFORMATION
Contractor; Name:
I
Business Name:
Business Addr:
City / Statej Zip:
I
REVIEWS AND COMMENTS
Review Tvpelj Status
i
ADDRESSING ASSIGNMENT COMPLETE
Block: 2
Automatic Sprinkler System? No
Fax Number:
Email:
000,
Reviewed By Date Started Date Completed Date Released
Lydia Galbraith 10/2/2015 10/5/2015 10/5/2015
Comment:
DOCUMENTS MISSING PENDING Deanna Givens 10/1/2015
10/1/2015 Comment: NOTICE OF COMMENCEMENT
10/1/2015 Comment: VEG PERMIT SENT TO ERD
10/2/2015 Comment: A COPY OF THE PAID UTILITY SERVICE RECEIPT FOR ELECTRIC SERVICE OR A LETTER FROM THE
ELECTRICAL UTILITY PROVIDER THAT ELECTRIC WILL BE AVAILABLE TO THE LOCATION.
ENVIRONMENTAL REVIEW PENDING
i
Comment:
FRONT COUNTER REVIEW COMPLETE Deanna Givens 10/1/2015 10/1/2015 10/1/2015
Comment:
PLANS EXAMINER REVIEW INCOMPLETE William Durden .1012612015
CommentA:} PLEASE SUBMIT THEENET� RFOMANCE SHEETS OR SUBMIT A THE NFRC FENSTRATION
10/26/2015 Cv MANUFACTURE CERTIFICATE FOR THE U-FACTOR AND THE SHGC SHOWING COMPLIANCE WITH
CHAPTER 4 SECTION 402.1.1 OF THE 2014 ENERGY CODE FIFTH EDITION.
Comment: ' PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND
t�
10/26/2015 APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA
ADMINISTRATIVE CODE
10/26/2015 Comment: feo'_- PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2014 FLORIDA BUILDING
CODE
10/26/2015 Comment: \ • PLEASE ADD TO THE PLANS THE CLIMATIC AND GEOGRAPHIC DESIGN CRIERIA WEATHERING AND
TERMITE AREA IN ACCORDANCE WITH TABLE 301.2.(1)
I
Planning A Development Services,
Building & Code Regulation DivisioiY
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462.2172 Fax:(772)462.6443
I ..
REVIEW COMMENTS
Page 2
10/26/2015 Comment: ,nl • PLEASE SHOW FLAME SPREAD INDEX AND SMOKE DEVELOPED INDEX FOR WALL AND CEILING FINISHES
{ IN ACCORDANCE WITH SECTION 302.9 OF THE 2014 FLORIDA RESIDENTIAL CODE
10/26/2015 Comment: • PLEASE SHOW THE FLAME SPREAD AND SMOKE DEVELOPED INDEX FOR THE INSULATION AS
REQUIRED IN SECTION 302.10 OF THE 2014 FLORIDA RESIDENTIAL CODE
Comment: • SHOW FLASHING DETAIL ON PLANS FOR ALL EXTERIOR WINDOWS AND DOORS. SEE SECTION R612.10
10/26/2015 FLASHING, SEALANTS, AND WEATHER STRIPPING, AND R703.8 FLASHING OF THE 2014 FLORIDA
RESIDENTAL BUILDING CODE.
i Comment: • ALL NEW SINGLE FAMILY HOMES SHALL PROVIDE AT LEAST ONE BATHROOM WITH A DOOR THAT HAS A
10/26/2015 CLEAR OPENING OF NO LESS THAN 29 WITH THE DOOR OPEN AT 90 DEGREES. SEE SECTION R320.1.1 OF
THE 2014 RESIDENTAL BUILDING CODE FIFTH EDITION.
10/26/2015 Comment: ✓• ELEVATION DETAILS SHOW ENCLOSED UNDER FLOOR SPACE. PLEASE SHOW DETAIL OF HOW THIS IS
TO BE INSTALLED.
10/26/2015 Comment: ELEVATION DETAILS SHOW ENCLOSED UNDER FLOOR SPACE. PLEASE SHOW DETAIL OF FOR THE
VENTILATION FOR THE CRAWL SPACE. SEE SECTION R408 OF THE 2014 RESIDENTAL BUILDING CODE.
Comment: • PLEASE FURNISH EITHER THE ICC EVALUATION REPORT OR A EVALUATION REPORT FROM A CERTIFIED
10/26/2015 TESTING LABORATORY THAT FOAM INSULATION MEETS THE REQUIRMENTS OF SECTION 316 OF THE 2014
FLORIDA RESIDENTIAL CODE
Comment:
10/26/2615 f/' 'LEASE SHOW THE METHOD OF ATTACHMENT FOR THE ROOF SHEATHING INCLUDING THE FASTENER
SIZE AND FASTNER SPACING IN ACCORDANCE WITH 803.2.3.1 OF THE 2014 FLORIDA RESIDENTIAL CODE
10/26/2015 Comment: V • PLEASE FURNISH TWO COPIES OF THE HARD] PRODUCT APPROVALS.
10/26/2015 Comment: • PLEASE FURNISH THE METHOD OF ATTACHMENT FOR THE WALL SHEATHING INCLUDING FASTENER
/SIZE AND FASTENER SPACING PER 107.2.1 OF THE 2014 FLORIDA RESIDENTIAL CODE
Comment: PLEASE FURNISH THE COMPRESSIVE STRENGHT OF THE CONCRETE BEING USED FOR THE FLOOR,
10/26/20.15 FOUNDATION, COLUMNS AND BEAMS BEING IN ACCORDANCE WITH 402.2 OF RTHE 2014 FLORIDA
BUILDING CODE
10/26/2016 Comment: • PLEASE FURNISH THE METHOD OF ATTACHMENT FOR THE FLOOR SHEATHING INCLUDING FASTENER
SIZE AND FASTENER SPACING PER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE
Comment: • PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE
10/26/26,15 SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED
DOCUMENTS
ZONING REVIEW
INCOMPLETE Lydia Galbraith 10/2/2015
10/2/2015
Comment: PLEASE PROVIDE A COPY OF THE HEALTH DEPARTMENT PERMIT FOR THE WELL.
Comment: PLEASE INDICATE THE FOLLOWING INFORMATION ON THE SURVEY:
- PROPOSED FINISHED FLOOR ELEVATION. MIN. REQUIRED IS 18" ABOVE CENTERLINE OF THE ADJACENT
10/2/201'5
ROAD (16.5') OR THE FLOOR HEIGHT REQUIRED FOR SEPTIC AND DRAINFIELD WHICHEVER IS GREATER.
- FEMA FLOOD ZONE INFORMATION.
- AT 2/16/12 ALL FEMA MAPS CHANGED IN ELEVATION NAVD AFTER THAT DATE ALL SURVEYS ARE
REQUIRED TO BE IN NAVD OR HAVE A CONVERTION RATE FROM NGVD TO NAVD.
10/2/2015
Comment: PLEASE PROVIDE 2 CORRECTED SIGNED AND SEALED SURVEYS. THE SURVEYS DO NOT NEED TO BE
RESTAMPED BY HEALTH DEP.
10/5/2015
Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS
EXAMINER MIGHT HAVE ADDITIONAL COMMENTS.