Loading...
HomeMy WebLinkAboutSTRUCTURAL PERFORMANCE CERTIFICATION - AUTH - 11-11-14 - 2Docunent Title: Structural Performance Doc No: FRM B1.02 Rev No: 7 Page 1 or: 1 >�'EYSTON SCANNED CiIrf1FIGAYpNO.fIVG Certification , iBY Authorization Report St Lucie County I Required By: PRO 131-03 CAR & Product ID Number: 190 - 1029.0 Issue Date: 11 /11 /2014 Revision Date: 11/17/2014 Expiration Date: 10/1/2018 Company Code- 1 an This Certification Authorization Report (CAR) is issued by Keystone Certifications, Inc. (KCU after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components. i This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified atwww.keystonecerts.com. Licensee Information: Product Information: PGT Industries Model: SH5500 View PVC Imp Single Hung 1070 Technology Dr. PO Box 1529 Operator Type: H Nokomis FL 34274 Config: EM/AII, GS-5/16" Ann Lami iG i Max Width: 52 Max Height: 92 Referenced Standard: )Product Rating: AAMA/WDMA/CSA 101/I.S.2/A440-11 Class LC-PG65 1324x2330 (52x92)-Type H Neg DP=70 Qualifying Test Information: Test Report No: FTL-7950 Test Report Expiration: 10/1/2018 Authorized .Signature: Digitally signed by Steven M. Urich DPI: cn=Steven M. Urich, o=Keystone 2/- Certifications, Inc.,ou, = email=surich@keystonecerts.com, c=US Date: 2014.11.1715:55:47-05'00' wW W. KEYSTONECERTS.COM Keystone Certifications, Inc. 564 Old York Road, Suite 5 Etters, Pennsylvania 17319 Phone: 717-932-8500 Fax: 717-932-8501 MAX. BUCK WIDTH SEE TABLE 1 26' MAX. B, SEE 12* MAX. O.C. SHEET 3 A, SEE SHEET3 12' MAX. O I MAX. UCK SEE 1 BUCK B NO ANCHORS AT SILL ` ELEVATION FOR TYP. EQUAL LEG FRAME, EQUAL-LITE CONFIGURATION GENERAL NOTES: SERIES 5500 IMPACT RESISTANT VINYL SINGLE HUNG WINDOW 1) THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS OFTHE FLORIDA BUILDING CODE. 2) ALL WOOD BUCKS LESS THAN 1-1YY THICK ARE TO BE CONSIDERED IX INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2' THICK OR GREATER 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER, (EOR) OR ARCHITECT OF RECORD, (AOR). 3) ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. USE ANCHORS OF SUFFICIENT EMBEDMENT. INSTALLATION ANCHORS SHOULD BE SEALED. OVERALL SEALINGIFLASHING STRATEGY FOR WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS BEYOND THE SCOPE OF THESE INSTRUCTIONS. 4) MAX. 114- SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE. USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. WOOD BUCKS, BY OTHERS, MUST BE SUFFICIENTLY ANCHORED TO RESIST LOADS IMPOSED ON THEM BY THE WINDOW. 5) THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WINDLOADS CORRESPONDING TO THE REQUIRED DESIGN PRESSURE. THE 33-1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. THE 1.6 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD. ANCHORS THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE FOR CORROSION RESISTANCE. B, SEE SHEET 3 A. SEE SHEET 3 - SEE TABLE 1 28- A MAX. MAX. O.C. 1 / 17.88 MAX O.C. MAX. B HEIGHT TABL X Q 1 D� MAx. / A 13.773' MAX. O.C. &1 B W'n.nV I alLL } ELEVATION FOR TYP. FLANGE FRAME, PROVIEW/ORIEL CONFIGURATION ().COTTAGE SIMILAR) TAR[ P 1- MAX. BUCK WIDTH SEE TABLE 1 2' MAX D. ET 4 —+•+ I+— 4-MAX. O.C. SHEET 4 C, SEE r SHEET4 l T 4' MAX. 0 I / MAX. BUCK JCK O.C. - HEIGHT SEE SEE X /� TABLE 1 C D 2' MAX.�— ELEVATION FOR TYP. FIN OR J-CHANNEL FRAME, EQUAL-LITE-CONFIGURATION (SIMILAR ANCHOR DIMENSIONS FOR OTHER CONFIGURATIONS) Window Buck Size Configuration Reini. Level Design Pressure Certification (CAR) Number Width Height + ( ) P� (_) Psf 52-1/8" 84" Equal-lite R1 50.0 50.0 190-285, 1028 52-1/8" 84"' Std. ProView 52-1/8" 91-13/16" Custom Sash 52-1/W 84" Equal-lite R2 65.0 70.0 190-286, 1029 52-1/8" 84" Std. ProView 52-1/8" 91-13116" Custom Sash J?n.r CERT. OF AUTH. #29296 1070 TECHNOLOGY DRIVE NI VENICE, FL 34275 (941}480-1600 VINYL SH WINDOW FPA (IMP --RESIST.) GENERAL NOTES & ELEVATIONS SHAPES MAY BE USED BY INSCRIBING THE SHAPE IN A BLOCK AND OBTAINING DESIGN PRESSURES FOR THAT BLOCK SIZE FROM THE TABLE ON THIS SHEET. 0 12/13/14 J ROSOWSKI SH-5500 h NTS N 1 OF 4 o z FPA-5500.0 � i' A. LYNN MILLER, P.E. P.E., 58705 Mi TAPI e m eurunoc ,"feTe1 , en Tuon, mu enauv Anchor Substrate Min. Edge Distance Min. Embedment 10 SMS (steel, 183 S.S. or410 S.S.) Max. DP of 50.0 P.T. Southern Pine (SG-0.55) 7/16" 1 Steel, A36 30 0.05T Steel Stud, A653 Gr. 33 3/8" 0.0346' (20 Ga.) Aluminum, 6063-75 VT_ 0.0713" 14 Ga. #12 SMS (steel, 188 S.S. or 410 S.S.) P.T. Southern Pine (SG=0.55) 9/16" Steel, A36 3/9" 0.05(y' Steel Stud, A053 Gr. 33 3/8" 0.0346" (20 Ga.) Aluminum, 6063-T5 3/8" 0.0713' 14 Ga. 3/18" Ultracon (steel) Max. OP of 50.0 P.T. Southern Pine (SG=0.55) 7/18" 11v8" Concrete (min. 2.85 ksi) 1" 13/8' Ungmted CMU, (ASTM G90) 2-1/2" 14/4" 1/4" Ultracon (steel) P.T. Southern Pine (SG=0.55) 1" 13/8" Concrete (min. 2.85 ksi) 1" 13/4" Ungmted CMU, (ASTM C430) 2-1/7 1-114" Concrete (min. 2.85 ksi) 2-1/T 13/4" 1/4" Crete -Flex (410 S.S.) P.T. Southern Pine (SG=0.5 i" 13/8" Concrete (min. 3.35 ksi) 1" 13/4" Ungrouted CMU, (ASTM C-90) 2-1/2" 1414" Concrete min, 3.35 ksi 2-1/2" 13/4" 1/4' Aggle Gator Concrete min. 3.275 ksi 1 P.T. Southern Pine (SG=0.55) 1-112" 1" 13I8" 13l8" .Ungrouted CMU, MTIM C- 0 T 1-1/4" WINDOW SHAPES AS SHOWN BELOW OR SIMILAR, MAYBE USED BY INSCRIBING THE SHAPE IN A BLOCK AND OBTAINING DESIGN PRESSURES AND ANCHORAGE FOR THAT BLOCK SIZE FROM THE TABLE ON SHEET 1. —�{ WIDTH WIDTH �— = 2 = JIT(7 RMUSTOP (EWAL{IiESHOLVl4 ARCHTOP (PROVIEWA')RIEL SHOWN) 1 TAFI F A- P=J1k1VAP` U=MT TVOGC Reinforcement Upper Ut6 LowerUte Level Bottom Rail ToRail p Bottom Rail Side Rails R1 B A A A R2 C A A _A Teal F 3• AMrHnRS INCTAI � FA Tl.lafln!!u uRCnDeI c Anchor Substrate Min. Edge Distance Min. Embedment 2-1/2'x Common Nail Max.x. DP of 50.0 D P.T. Southern Pine (SG=.55) 9/16" 2-7/16" 2-1/2" x .131" Ring -shank Nail P.T. Southern Pine (SG=.55) 9/16, 2-7116' 2-lrr x .W Roofing Nail P.T. Southem Pine (SG=.55) 9116' 2-7116" #10 SMS (sleet, 0 S. S.S. or 410 S.S.) P.T. Southern Pine (SG=.55) 3/4' 13/8" Aluminum, 6063-T5 3/8' 0.0713' (14 Ga.) Steel Stud, Gr. 33 31B" 0.0346' (20 Ga.) Steel, A36 3/6" 0.050' ANCHOR NOTES: 1)-UNGROUTED CMU' VALUES MAY BE USED FOR GROUTED CMU APPLICATIONS. 2) PANHEAD, FLATHEAD OR HEXHEAD ARE ACCEPTABLE. 3) ANCHOR LENGTH TO BE SO THAT A MIN. OF 3 THREADS EXTEND BEYOND THE METAL SUBSTRATE. 5116" A/A PVB — 7/16" AIR SPACE 1/8" ANNEALED OR TEMPERED GLASS DURASEAL, SUPERSPACER OR CARDINAL XL EDGE 5/16" A/A PVB — 3/8" AIR SPACE 3/16" ANNEALED OR TEMPERED GLASS DURASEAL, SUPERSPACER OR CARDINAL XL EDGE GLAZING TYPES GE-77DO OR DOW-791 SILICONE O EXTERIOR 1!2' NOt BITE TY a TYP. GLAZING DETAIL 7/8' NOM. [-- REINFORCENT TYPE A REINFORCENT TYPE B REINFORCENT TYPE C i r 1.�•1 i•/_ •J•� PVB INTERLAYER MANUFACTURED BY DUPONT INC. (AKA KURARAY AMERICA, INC.'`' VINYL SH WINDOW FPA(IMP: RESIST.) 0 12113/14 o GLASS/ANCHOR OPTIONS ern J ROSOWSKI `'�'~• _ ® 1,_c CERT. OF AUTH. lr19298 �� r�- ;:P.• -�`,: 1070 TECHNOLOGY -DRIVE N. VENICE, FL 34275 N po° yln4,.j/at, $ " 3 A. LYNN MILLER, P.E. (941)-480-1600 h SH-5500 NTS 2 OF 4 o z FPA-5500.0 z p.E.p 58705 EDGE DISTANCE SHOWN INSTALLED THROUGHIX BUCKSTRIP EMBEDMENT -i FLANGE SHOWN SHOWN FRAME INSTALLED INSTALLED SHOWN DIRECTLY TO THROUGHix r----�- EMBEDMENT EMBEDMENT SUBSTRATE BUCKSTRIP 00 T r EDGE ❑G� o G- �O EDGE �a DISTANCE a DISTANCE �JI/a �UU OPT. SASH TOP EDGE I, LS 21 LIFT RAIL EXTERIOR DISTANCE S q C S 0 D FLANGE FRAME jEQUAL 0 SHOWN BUCK WIDTH �'11 LEG FRAME HORIZONTAL SECTION A -A SHOWN BucK J HEIGHT 0 D ❑L� INSTALLATION NOTES: ' EXTERIOR 1 D 1) SEE SHEET 1 FOR SPACING REQUIREMENTS. 2) SEE TABLE(S) ON SHEET 2 FOR ANCHORAGE AND SUBSTRATE REQUIREMENTS. 3) MAX. SHIM THICKNESS TO BE 1/4'. 4) GLASS SHOWN IS FOR ILLUSTRATIVE PURPOSES t I - a ONLY AND MAY DIFFER TO MEET DESIGN OPT. SASH I FLANGE a REQUIREMENTS. BOTTOM LIFT - ' HANOLEA.00K FRAME O FIN AND/OR FLANGE MAY BE REMOVED TO CREATE J SHOWN OTHER FRAME TYPES. EQUAL LEG FRAME INSTALLATION THROUGH EXTERIOR SHOWN J�El THE FRAME. INTO METAL • ! . ! ..: ! ; r: r NO ANCHORS .` a'-. •'.;c::_!; REQUIRED IN / VINYL SH WINDOW FPA (IMP. -RESIST.) 0 12/13l14 FLANGE OR T EQUAL -LEG - FRAME SILLS a FLANGE & EQUAL-LEG/BOX FRAMES ,-L J ROSOWSKI S ij VERTICAL SECTION B-B CERT.OFAUTH.!l29296 x8 '`;;:•. u.... 1070 TECHNOLOGY DRIVE- - -- - - - - - - - — — —-N-VENICE, FL 34275 (941)-480-1600 SH-5500 H NTS ° 3 OF 4 3 z FPA-5500.0 z z° A. LYNN MILLER, P.E. REM 58705 SHOWN INSTALLED _ EDGE DISTANCE SHOWN INSTALLED SHOWN INSTALLED THROUGHTHE —i THROUGH THE THROUGH THE FRAME FRAME INTEGRAL FIN J-CHANNEL <— EMBEDMENT EDGE DISTANCE (-+— FRAME EMBEDMENT j SHOWN 0 I O �� �n�� Qn f I E DIS' OPT. SASH TOP LS 2J I LIFT RAIL BUCK II ' HEIGHT r EXTERIOR a FRAME SHOWN BUCK WIDTH HORIZONTAL SECTION C-C RENT II —� SHOWN INSTALLATION NOTES 1)SEE SHEET( FOR SPACING iEQUIREMENTS. t) SEE TABLE(S) ON SHEET 2 FOR 4NCHORAGE AND SUBSTRATE tEQUIREMENTS. I) MAX. SHIM THICKNESS TO BE 1/4". I) GLASS SHOWN IS FOR ILLUSTRATIVE 'URPOSES ONLY AND MAY DIFFER TO BEET DESIGN REQUIREMENTS. i) FIN AND/OR FLANGE MAY BE REMOVED f0 CREATE OTHER FRAME TYPES. �-7 1 1 OPT. SASH ' FIN . J BOTTOM LIFT FRAME HANDLEfLOCK �� SHOWN FIN EXTERIOR FRFlAME o EXTERIOR FRAME o SHOWN SHOWN INSTALLATION THROUGH INSTALLATION THROUGH THE ��I�000 THE FRAME, INTO METAL INTEGRAL FIN, INTO METAL 0 SHOWN EDGE _ INSTALLED DISTANCE TH THE EDGE ANY SH WINDOW FPA (IMP: RESIST.) 0 12/13/14 -"''' INTEGRAL FIN —�i _. DISTANCE o J-CHANNEL & INTEGRAL FIN FRAMES L� J ROSOWSKI -, J• .(a�t' Fes-- EMBEDMENT � _ VERTICAL SECTION D-D CERT. OF AUTH.#29296 � - •• •"' -•,' 1070 TECHNOLOGY DRIVE - - - - - - - — — -- - - - N.VENICE, FL 34275 (941) 1600 SH-5500 ° NTS v 4 OF P.E.# 58705 4 Q z FPA-5500.0 z A. LYNN MILLER, P.E. '^ �n CD i