HomeMy WebLinkAboutEVALUATION REPORT - FLOOD FLAPS - 10-28-18FILE UUIJY NOV 2o1s REPORT HOLDER: FLOOD FLAPS®, LLC POST OFFICE BOX 1003 ISLE OF PALMS, SOUTH CAROLINA 294S1 EVALUATION SUBJECT: SCANNED BY St Lucie County FLOOD FLAPS® AUTOMATIC FLOOD VENTS: MODELS FFWF12; FFNF12; FFWF08; FFNF08; FFWF05; FFNF05 ICC o ICC _ ICC C� CMG C LISTED Look for the trusted marks of Conformity! "2014 Recipient of Prestigious Western States Seismic Policy Council (IVSSPC) Award in Excellence" A Subsidiary of CO EC00HC L XCLES Evaluation Reports are not to be construed as representing aesthetics or any other attributes nota SCC� W specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a G9,9 recommendatio for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report Pr dl Cp o o 0- B.dy �M CCN Copyright 0 2d17 ICC Evaluation Service, LLC. All rights reserved. Evaluation Report Reissued September 2017 This report is subject to renewal September 2018, www.iC6-es.or4 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00—OPENINGS Section: 08 95 43=Vents/Foundation Flood Vents REPORT HOLDER: FLOOD FLAPS®, LLC POST OFFICE BOX 1003 ISLE OF PALMS, SOUTH CAROLINA 29451 (843) 881.0190 EVALUATION SUBJECT. FLOOD F FFWF12; 1.0 EVAI Complll ■ 2015, ■ 2015, (IRC) ■ Physic ■ Water ■ Weath, 2.0 USES Flood the e walls. 3.0 DE 3.1 C AUTOMATIC FLOOD VENTS: MODELS ; FFWF08; FFNF08; FFWF05; FFNF05 PION SCOPE with the following codes: 2 and 2009 Intemational Building Code® (IBC) 12 and 2009 Intemadonal Residential Cade® evaluated: operation automatic flood vents are used to provide for ion of hydrostatic flood forces on exterior models also allow natural ventilation. Flood Flaps"" automatic flood vents are engineered mechanically operated flood vents (FVs) that automatically allow flood waters to enter and exit enclosed areas. The FVs are constructed of ABS plastic which serves as the FV's housing, and a front grill that contains an anodized metal screen imbedded in polypropylene plastic. On contact with rising flood water, the grill will disengage from its secured position, allowing flood water and debris to flow through in 'either direction. The FVs are available in two series as described in Section 3.3. The sealed series models contain two rubber flaps that dose the. FV to the passage of air when using with conditioned areas or sealed crawl spaces. In the same manner as the grill, the two rubber flaps.are pushed open by water pressure, allowing water and debris to flow through the FV in either direction. See Figure 1 for an illustration of the Flood Flap? automatic FV. 3.2 Engineered Opening: The Flood Flaps® automatic FVs comply with the design principle noted in Sections 2.7.2.2 and 2.7.3 of ASCE/SEI 24-14 [Section 2.6.2.2 of ASCE/SEI 24-05 (2012 and 2009 IBC and IRC)] for a rate of rise and fall of 5 feet per hour (0.423 mm/s). In order to comply with the engineered opening requirement of ASCE/SEI 24, Flood Flaps® automatic FVs must be installed in accordance with Section 4.0. 3.3 Flood Vent Series Models: Flood Flaps® automatic FVs are available in two series with multiple models and sizes as described in Table 1. The sealed series models, designated FFWF, include two rubber flaps for the prevention of air Now. The multi- purpose series, designated FFNF, omits the rubber flaps. 3.4 Natural Ventilation: Flood Flaps® automatic FV models FFNF12, FFNF08, FFNF05, and FFNF02 have metal screens with inch by 14 inch (6 mm b�► 6 mm) openings and provide 37 square inches (0.02 m) of net free opening to supply natural ventilation for under -floor ventilation. Flood Flaps® automatic FV models FFWF12, FFWF08, and FFWF05 have not been evaluated for use as openings for under- floor ventilation. 4.0 DESIGN AND INSTALLATION Flood Flaps® automatic FVs are designed to be installed into walls of existing or new construction. Installation of the FVs must be in accordance with the manufacturer's instructions, the applicable code and this report Flood Flaps® automatic FVs can be installed in wood, masonry and concrete walls up to a thickness of 12 inches (305 mm). In order to comply with the engineered opening design principle noted in Sections 2.7.2.2 and 2.7.3 of ASCE/SEI 24-14 [Section 2.6.2.2 ' of ASCE/SEI 24-05 (2012 and 2009 IBC and IRC)], the Flood Flaps® FVs must be installed as follows: ■ With a minimum of two openings on different sides of each enclosed area. ICC-ESEvatuationReporisam not to be rnratruedas representing aesthetics or my other attributes noispeeificallyaddressed, nor are theylo be mastrued as an endorsement ofdiesubject ofttte report or a recommendationfor Its use There is no narramy by ICCEva/uation Service LLC express or implied, as to anyfmding or other matter in this report, or as to any product covered by the report Copyright © 20171CC Evaluation Service, LLC. Ali rights reserved. Page 1 of 3 r ESR-3s601 I Most and Trusted 2of3 J ■ With a minimum of one FV for every 220 square feet (20 m2) of enclosed area. ■ Below the base flood elevation. ■ With the bottom of the FV located a maximum of 12 inches (305 mm) above grade. 5.0 CONDITIONS OF USE The Flood Flaps® automatic flood vents described in this report comply with, or are suitable altematives to what is specified) in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The Flood Flaps® automatic FVs must be Installed in accordance with this report, the applicable code and the manufacturer's installation instructions. In the event of a conflict, the instructions in this report 5.2 The Flood Flaps® automatic FVs must not be used in place of "breakaway walls" in coastal high hazard areas, but are permitted for use in conjunction with breakaway walls in other areas. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Mechanically Operated Flood Vents (AC364), dated August 2015. 7.0 IDENTIFICATION The Flood Flaps® models recognized in this report are identified by a label bearing the manufacturer's name, the model number, and the evaluation report number (ESR-3560). TABLE 1—FLOOD FLAP AUTOMATIC FLOOD VENT MODEL SIZES MODEL NUMBER MODEL DESIGNATION ROUGH OPENING (Width X Height) (inches) VENT SIZE (W X H X D) (inches) ENCLOSED AREA COVERAGE NET FREE AREA OPENING' FFWF12 Sealed Series 16 x 8 1 SPI, X 731, X 12 220 NA FFNF12 i Multi -Purpose 16 x 8 15 /g X /4 X 12 220 37 FFWF08 Sealed Series 16 x 8 15 /e x /4 x 8 220 NA FFNF08 Multi -Purpose 16 x 8 15 /e x /4 x 8 220 37 FFW F05 Sealed Series 16 x 8 15 /s x t3/4 x 5 220 NA FFNF05 Multi -Purpose 16 x 8 15 /8 x r14 x 5 220 37 For m: i InCn = zo.4 mm; l r- = uxua m 'For untler floor ventilation only. I Most Widely Accepted and Trusted Page 3 of 3 f 1URE 1—FLOOD FLAW AUTOMATIC FLOOD VENT FFNFi FFNF05 LOOD FLAPS° AUTOMATIC FLOOD VENT SERIES MODELS &" DEPTH 5" DEPTH _APS® AUTOMATIC FLOOD VENTS MULTIPLE DEPTH OFFERINGS