HomeMy WebLinkAboutEVALUATION REPORT - FLOOD FLAPS - 10-28-18FILE UUIJY
NOV 2o1s
REPORT HOLDER:
FLOOD FLAPS®, LLC
POST OFFICE BOX 1003
ISLE OF PALMS, SOUTH CAROLINA 294S1
EVALUATION SUBJECT:
SCANNED
BY
St Lucie County
FLOOD FLAPS® AUTOMATIC FLOOD VENTS:
MODELS FFWF12; FFNF12; FFWF08; FFNF08; FFWF05; FFNF05
ICC o ICC _ ICC
C� CMG C LISTED
Look for the trusted marks of Conformity!
"2014 Recipient of Prestigious Western States Seismic Policy Council
(IVSSPC) Award in Excellence"
A Subsidiary of CO EC00HC L
XCLES Evaluation Reports are not to be construed as representing aesthetics or any other attributes nota
SCC� W
specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a G9,9
recommendatio for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as
to any finding or other matter in this report, or as to any product covered by the report Pr dl Cp o o 0- B.dy �M CCN
Copyright 0 2d17 ICC Evaluation Service, LLC. All rights reserved.
Evaluation Report
Reissued September 2017
This report is subject to renewal September 2018,
www.iC6-es.or4 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council®
DIVISION: 08 00 00—OPENINGS
Section: 08 95 43=Vents/Foundation Flood Vents
REPORT HOLDER:
FLOOD FLAPS®, LLC
POST OFFICE BOX 1003
ISLE OF PALMS, SOUTH CAROLINA 29451
(843) 881.0190
EVALUATION SUBJECT.
FLOOD F
FFWF12;
1.0 EVAI
Complll
■ 2015,
■ 2015,
(IRC)
■ Physic
■ Water
■ Weath,
2.0 USES
Flood
the e
walls.
3.0 DE
3.1 C
AUTOMATIC FLOOD VENTS: MODELS
; FFWF08; FFNF08; FFWF05; FFNF05
PION SCOPE
with the following codes:
2 and 2009 Intemational Building Code® (IBC)
12 and 2009 Intemadonal Residential Cade®
evaluated:
operation
automatic flood vents are used to provide for
ion of hydrostatic flood forces on exterior
models also allow natural ventilation.
Flood Flaps"" automatic flood vents are engineered
mechanically operated flood vents (FVs) that automatically
allow flood waters to enter and exit enclosed areas. The
FVs are constructed of ABS plastic which serves as the
FV's housing, and a front grill that contains an anodized
metal screen imbedded in polypropylene plastic. On
contact with rising flood water, the grill will disengage from
its secured position, allowing flood water and debris to flow
through in 'either direction. The FVs are available in two
series as described in Section 3.3.
The sealed series models contain two rubber flaps that
dose the. FV to the passage of air when using with
conditioned areas or sealed crawl spaces. In the same
manner as the grill, the two rubber flaps.are pushed open
by water pressure, allowing water and debris to flow
through the FV in either direction. See Figure 1 for an
illustration of the Flood Flap? automatic FV.
3.2 Engineered Opening:
The Flood Flaps® automatic FVs comply with the design
principle noted in Sections 2.7.2.2 and 2.7.3 of ASCE/SEI
24-14 [Section 2.6.2.2 of ASCE/SEI 24-05 (2012 and 2009
IBC and IRC)] for a rate of rise and fall of 5 feet per hour
(0.423 mm/s). In order to comply with the engineered
opening requirement of ASCE/SEI 24, Flood Flaps®
automatic FVs must be installed in accordance with
Section 4.0.
3.3 Flood Vent Series Models:
Flood Flaps® automatic FVs are available in two series
with multiple models and sizes as described in Table 1.
The sealed series models, designated FFWF, include two
rubber flaps for the prevention of air Now. The multi-
purpose series, designated FFNF, omits the rubber flaps.
3.4 Natural Ventilation:
Flood Flaps® automatic FV models FFNF12, FFNF08,
FFNF05, and FFNF02 have metal screens with inch by
14 inch (6 mm b�► 6 mm) openings and provide 37 square
inches (0.02 m) of net free opening to supply natural
ventilation for under -floor ventilation. Flood Flaps®
automatic FV models FFWF12, FFWF08, and FFWF05
have not been evaluated for use as openings for under-
floor ventilation.
4.0 DESIGN AND INSTALLATION
Flood Flaps® automatic FVs are designed to be installed
into walls of existing or new construction. Installation of
the FVs must be in accordance with the manufacturer's
instructions, the applicable code and this report Flood
Flaps® automatic FVs can be installed in wood, masonry
and concrete walls up to a thickness of 12 inches
(305 mm). In order to comply with the engineered opening
design principle noted in Sections 2.7.2.2 and 2.7.3 of
ASCE/SEI 24-14 [Section 2.6.2.2 ' of ASCE/SEI 24-05
(2012 and 2009 IBC and IRC)], the Flood Flaps® FVs must
be installed as follows:
■ With a minimum of two openings on different sides of
each enclosed area.
ICC-ESEvatuationReporisam not to be rnratruedas representing aesthetics or my other attributes noispeeificallyaddressed, nor are theylo be mastrued
as an endorsement ofdiesubject ofttte report or a recommendationfor Its use There is no narramy by ICCEva/uation Service LLC express or implied, as
to anyfmding or other matter in this report, or as to any product covered by the report
Copyright © 20171CC Evaluation Service, LLC. Ali rights reserved. Page 1 of 3
r ESR-3s601 I Most
and Trusted
2of3
J
■ With a minimum of one FV for every 220 square
feet (20 m2) of enclosed area.
■ Below the base flood elevation.
■ With the bottom of the FV located a maximum of
12 inches (305 mm) above grade.
5.0 CONDITIONS OF USE
The Flood Flaps® automatic flood vents described in this
report comply with, or are suitable altematives to what is
specified) in, those codes listed in Section 1.0 of this report,
subject to the following conditions:
5.1 The Flood Flaps® automatic FVs must be Installed in
accordance with this report, the applicable code and
the manufacturer's installation instructions. In the
event of a conflict, the instructions in this report
5.2 The Flood Flaps® automatic FVs must not be used in
place of "breakaway walls" in coastal high hazard
areas, but are permitted for use in conjunction with
breakaway walls in other areas.
6.0 EVIDENCE SUBMITTED
Data in accordance with the ICC-ES Acceptance Criteria
for Mechanically Operated Flood Vents (AC364), dated
August 2015.
7.0 IDENTIFICATION
The Flood Flaps® models recognized in this report are
identified by a label bearing the manufacturer's name,
the model number, and the evaluation report number
(ESR-3560).
TABLE 1—FLOOD FLAP AUTOMATIC FLOOD VENT MODEL SIZES
MODEL
NUMBER
MODEL
DESIGNATION
ROUGH OPENING
(Width X Height)
(inches)
VENT SIZE
(W X H X D)
(inches)
ENCLOSED AREA
COVERAGE
NET FREE AREA
OPENING'
FFWF12
Sealed Series
16 x 8
1 SPI, X 731, X 12
220
NA
FFNF12
i
Multi -Purpose
16 x 8
15 /g X /4 X 12
220
37
FFWF08
Sealed Series
16 x 8
15 /e x /4 x 8
220
NA
FFNF08
Multi -Purpose
16 x 8
15 /e x /4 x 8
220
37
FFW F05
Sealed Series
16 x 8
15 /s x t3/4 x 5
220
NA
FFNF05
Multi -Purpose
16 x 8
15 /8 x r14 x 5
220
37
For m: i InCn = zo.4 mm; l r- = uxua m
'For untler floor ventilation only.
I Most Widely Accepted and Trusted Page 3 of 3
f
1URE 1—FLOOD FLAW AUTOMATIC FLOOD VENT
FFNFi
FFNF05
LOOD FLAPS° AUTOMATIC FLOOD VENT SERIES MODELS
&" DEPTH
5" DEPTH
_APS® AUTOMATIC FLOOD VENTS MULTIPLE DEPTH OFFERINGS