Loading...
HomeMy WebLinkAboutNOA - SKYLIGHTMIAMI-DADS MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 SCANNEDT (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) BY www.miamidade.gov/building Sum-Tek Manufacturing, Inc. St Lucie County 10303 General Dr. RECEIVED Orlando, FL 3 I LE COPY ARE THFASTENERS PONSIBIUNOFTHEE S NOV 2, 6 ?018 ,SCOPE: C0ICTOR OR RECORD This NOA is being issued under the applicable rules and regulations governing the use of co #rup}gp+tartntEtit The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product C-oritfo-l.:: ­ -" Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed t0A , %`I fi01 RK Y COR ECTIONS Zone of the Florida Building Code. REQUIRED BY FIELD INSPECTORS THAT DESCRIPTION- MD-CMA Skylight. MAY BE NECESSARY IN ORDER TO COMPLY WITH Ad 2 AP LICAB r DES. APPROVAL DOCUMENT: Drawing No. CMMA-002, titled "D-CMA", sheets 1 an of Z, prepaid 9 Sun-Tek Manufacturing, Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr., P.E., on October 06, ',2017, bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and the expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved" or the Product Control Seal, unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shal,i be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #15-0513.05 and consists of this page 1, evidence submitted pages E-1, E-2, and E-3 as well as approval document mentioned above. The�submitted documentation was reviewed by He)my A. Makar, P.E., M.S. LUCIE COUNTY ��`�MIAMFDADECOUN BUIL� ANo. 17-1023.18 IEWED FOR pirationDate: 03/13/2023 JAPPROVED1 OMPLIAN VIE pproval Date: 03/15/2018 Page 1 PLANS AND PERMIT MUST BE KEPT JOB SITE OR NO INSPECTION(S) WILL MADE �e�-ccr2A-L-. NOTICE OFACCEPTANCE: EVIDENCE SUBMITTED EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #08-0110.06 DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. CM4-002, titled "AIM-CMA ", sheets 1 and 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated 09113195 and 04125195, with no revisions, signed and sealed by Rene J. Quiroga, P.E. TESTS 1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 24113.2.1, TAS 202-94 along with marked -up drawings and installation diagram of Model MD-CMA Curb Mounted Plastic Dome Skylight, prepared by National Certified Testing Laboratories, Test Report #210-2885-1, dated 10131102, signed and sealed by W. A. Davis Jr., P.E. CALCULATIONS 1. Anchor calculations prepared by Product Technology Corporation on 02105103, signed and sealed by A. Perez Maldonado, PE QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO) MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 07-0212.01 issued to General Electric Plastics for their "Lexan Sheet Products", approved 05/25/07, expiring on 07/17/08. STATEMENT i. Code compliance letter issued by Product Technology Corporation on 02/06/03, signed and sealed by A. Perez Maldonado (Evidence Submitted under NOA # 03-0401.07) OTHERS 1. Notice of Acceptance No. 03-0401.07, issued to Sun-Tek Manufacturing, Inc., approved on 10/09/03 and expiring on 03/13/08. 2. No change letter issued by Sun-Tek Manufacturing, Inc., dated 01/02/08, signed by James Feudner. —I" Z' &4� - elmy A. Makar, P.E., M.S. Product Control Section Supervisor NOA No. 17-1023.18 Expiration Date: 03/13/2023 Approval Date: 03/15/2018 E-1 Tek NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #11-0601.04 �. DRAWINGS 1. Drawing No. CMA-002, titled "MD' -CM ", sheets I and 2 of 2, prepared by Sun-Tek - Manufacturing, Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr., P.E., on May 08, 2012. B. TESTS L Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 24113.2.1, TAS 202-94 along with marked -up drawings and installation diagram of Model MD-CMA Curb . Mounted Plastic Dome Skylight, prepared by National Certified Testing Laboratories, Test Report No. NCTL-210-3859-1, dated 03104113, signed and sealed by Gerard J. j Ferrara, P.E. . C. CALCULATIONS i 1. Anchor calculations prepared by J & L Wells Consulting LLC, 19 pages, dated 0311912013, signed and sealed by James D. Wells, Jr., P.E. D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENT 1. Florida Building Code, 2010 Edition, compliance letter prepared by J & L Wells Consulting LLC, dated 0412512012, signed and sealed by James D. Wells, Jr., P.E. 3.1 EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #15-0513.05 Al. DRAWINGS 1. Drawing #CMA-002, titled ".YID-CMA ", sheets 1 and 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated 05109111, signed & sealed by James D. Wells, Jr., P.E., on 05108112. B: TESTS 1. None. C. CALCULATIONS 1. None. my A. Maker, P.E., M.S. Product Control Section Supervisor NOA No. 17-1023.18 Expiration Date: 03/13/2023 Approval Date: 03/15/2018 E -2 NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. MATERIAL CERTIFICATIONS 1. None. STATEMENT 1. Florida Building Code, 2014 Edition, compliance letter prepared by J.& L Wells Consulting LLC, dated 0510512015, signed and sealed by James D. Wells, Jr., AE. NEW EVIDENCE SUBMITTED DRAWINGS 1. Drawing No. CMA-002, titled "MD-CMA ", sheets I and 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr., P.E., on October 06, 2017. TESTS 1. None., CALCULATIONS 1. None. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. MATERIAL CERTIFICATIONS 1. None. STATEMENT 1. Florida Building Code, 2017 Edition, compliance letter prepared by J & L Wells Consulting LLC, dated 1010612017, signed and sealed by James D. Wells, Jr., P.E. elmy A. Makar, P.E., M.S. Product Control Section Supervisor NOA No. 17-1023.18 Expiration Date: 03/13/2023 Approval Date: 03/15/2018 E -3 �*t,1i�IBtt��s� pAYID J & L Wells Consulting LLC ``��wi�� Engineer of Record: 1453 Arbitus Circle ems' I - - - -- -- - -James D. Wells, -Jr., P.E. - -- - Oviedo- FL-32765 - - �'- �. �36 (j - Professional Engineer No. 53616 (407) 496-5489 ;a Certificate of Authorization No. 27162 0� STAVE ®F E' D CfvA PLAN �_ s����:,"'�C�aatOP` ..•_,� b� H�- 3.0000s910.625---1 DIMENSI❑NS F❑ FASTENER L❑CAT 14 FASTENERS TO CURB 6 RIVETS POLY TO ALUM RIVET L❑CATI❑NS RSIENER SCHEDULE SKYLIGHT TO CURB 10 X 2 PAN HEAD SHEET METAL SCRF1 PER LONC I PER SHORT SIDE SIDE 13.625 27.256 MAX. TENER SCHEDULE CURB DECK #ID X 3" DECK SCREWS PER LONG SIDE PER SIDESHDR7 S'UmNE DLODD,G IDONUNDoS) S)S-ID00 SUTANr BErMEFN SKR)CHI AHD E . (CONrDDDS) OECD rD1�D ST O GJDS0 IN][H ALUL�iHuN ANDSNEiDFP LANDS .IOY5 -IS ArwAnKn R4ef N RE /10 t(2 PHWlS PAN TLrAD SIIFET METAL SCDLW 1A1 ON LONG 9D[R (3) ON SHORT SiOE AID - 3- DECK SCREE 1.) ON LOND SDE (3) ON SHORT SIDE c`CDN"°"Dw t°n Nrtu TxgEs (2) DWG.#: CMA-002 our ER DONE .D70 PDLTCARBWAre O10 POLYCARDDtaITC SHtCi PAIRAN PAlSDM. l Sh6fELD AUXROtON m SNPC 1[r.D1 D03r IWER D30 YwTrn-eo"et PAL U T, LETor URAN 90340.V. W In RCN W °' w� rsNDD WALC NAICRNL 1 er OTHM ( . ROVED 0 Ir) DADE COUNTY) IR SYP (50 QS GURB N%Ht TD OF ax�nInCro i0 Nrtxi.N or Al Ar LOAEst rraHt D! F L i0 ROOT SURTAOE NOTE: (APPN�OrP[oUBY D�ADe tcouNtixj (1) ALL ROOFING DETAILS SHALL COMPLY WITH CHAPTER 15 OF THE 2017 FLORIDA BUILDING CODE (2) 4" MINIMUM DISTANCE FROM ANGLE LIP TO ROOF DESIGN PRESSURE RATING SURFACE IS FOR SHINGLE. OR B.U,R. WITHOUT +— 60 PSF, INSULATION, FOR INSULATION AND TILE ROOF ADD LARGE MISSILE IMPACT RESISTANCE TILE HEIGHT AND INSULATION THICKNESS TO 4' MINIMUM HEIGHT. (3) ANCHORS TO BE MADE OF NON -CORROSIVE MATERIAL. COMPATABLE WITH ALUMINUM. RIVET SCHEDULE DECD 70 POLYCARBONATE 3116- PER LONG PER SHO SIDE I SIDE RF I5 D a" COrQPxy(,.T '&'*h the 0014dz ;? rceptance til0 - a Z3.18 E'V'I'aticnDate O o� By ivADiR *15" &4�_ 3 ''-""' PRODUCT NAME; ,N,, MD-CMA SUN-TEK MANUFACTURING, INC. DAT I 09 11 CALF D [t Nc� A— 10303 GENERAL DRIVE ORLANDO. FL 321324 oar® SDIma yes®�/" J & L Wells Consulting LLC w������✓ v9� '� rs� 1453 Arbitus Circle Engineer of Record: , OviedoFL 327_65 _ - -- - - -- - - - — - James-D.-Wel1s; jr.-P.E, - - •� O. Professional Engineer No. 53616 (407) 496-5489 Certificate of Authorization No.27162 =0; �alb��7� ram` PART NAME: PROD IrT DRAWING _ _- �4� 3�i�4TE OF: DESIGN PRESSURE RATING +— 50 PSF # 10 X 2" SCREW PPH LARGE MISSLE IMPACT RESISTANCE (4) ON LONG SIDE& (3) ON SHORT SIDE MINIMUM ENBEDMENT 1" DECO RING STI-275 .060 THICK ALUMINUM 6063 T6 MITRE AND WELDED CORNERS 4" MINIMUM SEE NOTE #2 GLES (2) 2X SYP (SG 0.55) CURB HEIGHT TO BE SUFFICIENT TO MAINTAIN 4" MINIMUM AT LOWEST POINT OF FRAME TO ROOF SURFACE SUPPLIED BY OTHERS AN (APPROVED BY DADE COUNTY) JER LINER .030 polycorbonot (Polrom Palsun, Sheffield Mokrolon or Sobic Lexon 9034) as complying with the Fioaiva Building Code AceepU ce No) 7 i' Xpilytion Date o Z—aa FINISHED WALL MATERIAL BY OTHERS ( APPROVED DADE COUNTY) 5-1/2" DOME RISE AIR FILLED INSULATED SPACE #10 x 3" DECK SCREW (4) ON LONG SIDE (3) ON SHORT SIDE - MINIMUM ENBEDMENT 5/8" NOTE: (1) ALL ROOFING DETAILS SHALL COMPLY WITH CHAPTER 15 OF THE 2017 FLORIDA BUILDING CODE (2) 4" MINIMUM DISTANCE FROM ANGLE LIP TO ROOF SURFACE IS FOR SHINGLE. OR B.U.R. WITHOUT INSULATION. FOR INSULATION AND TILE ROOF ADD TILE HEIGHT AND INSULATION THICKNESS TO 4" MINIMUM HEIGHT. (3) ANCHORS TO BE MADE OF NON -CORROSIVE MATERIAL, COMPATABLE WITH ALUMINUM. STS-1000 SEALANT (CONTINOUS) PRODUCT NAME, M o _ c MA DWG.41; CMA-002 -OUTER DOME .070 POLYCAR13ONATE (Polrom Polsun, Sheffield Mokrolon or Sobic Lexan 9034) SILICONE BEDDING (CONTINUOUS) BUTYL RUBBER SEALANT BETWEEN SKYLIGHT AND CURB (continuous) SHIM® EA, ANCHOR (TYP) WITH LOAD BEARING SHIM 1_ 0.500 MAX. I3/ 16" RIVET )/LONG SIDE 1 /SHORT SIDE FLASHING BY OTHERS IN ACCORDANCE WITH NRCA ROOF DECK SUN-TEK MANUFACTURING, INC. 10303 GENERAL DRIVE ORLANDO. FL 32824 Co O /