HomeMy WebLinkAboutNOA - SKYLIGHTMIAMI-DADS MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
SCANNEDT (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) BY www.miamidade.gov/building
Sum-Tek Manufacturing, Inc. St Lucie County
10303 General Dr. RECEIVED
Orlando, FL 3 I LE COPY ARE
THFASTENERS PONSIBIUNOFTHEE S NOV 2, 6 ?018
,SCOPE: C0ICTOR OR RECORD
This NOA is being issued under the applicable rules and regulations governing the use of co #rup}gp+tartntEtit
The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product C-oritfo-l.:: -"
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right
to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed t0A , %`I fi01 RK
Y COR ECTIONS
Zone of the Florida Building Code. REQUIRED BY FIELD INSPECTORS THAT
DESCRIPTION- MD-CMA Skylight. MAY BE NECESSARY IN ORDER TO
COMPLY WITH Ad 2 AP LICAB r DES.
APPROVAL DOCUMENT: Drawing No. CMMA-002, titled "D-CMA", sheets 1 an of Z, prepaid 9
Sun-Tek Manufacturing, Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr., P.E., on October
06, ',2017, bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance
number and the expiration date by the Miami -Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved" or the Product Control Seal, unless
otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it
shal,i be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA #15-0513.05 and consists of this page 1, evidence submitted pages E-1, E-2, and E-3 as
well as approval document mentioned above.
The�submitted documentation was reviewed by He)my A. Makar, P.E., M.S.
LUCIE COUNTY
��`�MIAMFDADECOUN BUIL� ANo. 17-1023.18
IEWED FOR pirationDate: 03/13/2023
JAPPROVED1
OMPLIAN
VIE pproval Date: 03/15/2018
Page 1
PLANS AND PERMIT MUST BE KEPT JOB
SITE OR NO INSPECTION(S) WILL MADE
�e�-ccr2A-L-.
NOTICE OFACCEPTANCE: EVIDENCE SUBMITTED
EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #08-0110.06
DRAWINGS
1. Manufacturer's die drawings and sections.
2. Drawing No. CM4-002, titled "AIM-CMA ", sheets 1 and 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated 09113195 and 04125195, with no revisions, signed and sealed by
Rene J. Quiroga, P.E.
TESTS
1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 24113.2.1, TAS 202-94
along with marked -up drawings and installation diagram of Model MD-CMA Curb
Mounted Plastic Dome Skylight, prepared by National Certified Testing Laboratories,
Test Report #210-2885-1, dated 10131102, signed and sealed by W. A. Davis Jr., P.E.
CALCULATIONS
1. Anchor calculations prepared by Product Technology Corporation on 02105103,
signed and sealed by A. Perez Maldonado, PE
QUALITY ASSURANCE
1. Miami Dade Building Code Compliance Office (BCCO)
MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 07-0212.01 issued to General Electric Plastics for their
"Lexan Sheet Products", approved 05/25/07, expiring on 07/17/08.
STATEMENT
i. Code compliance letter issued by Product Technology Corporation on 02/06/03,
signed and sealed by A. Perez Maldonado
(Evidence Submitted under NOA # 03-0401.07)
OTHERS
1. Notice of Acceptance No. 03-0401.07, issued to Sun-Tek Manufacturing, Inc.,
approved on 10/09/03 and expiring on 03/13/08.
2. No change letter issued by Sun-Tek Manufacturing, Inc., dated 01/02/08, signed by
James Feudner.
—I" Z' &4� -
elmy A. Makar, P.E., M.S.
Product Control Section Supervisor
NOA No. 17-1023.18
Expiration Date: 03/13/2023
Approval Date: 03/15/2018
E-1
Tek
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #11-0601.04
�. DRAWINGS
1. Drawing No. CMA-002, titled "MD' -CM ", sheets I and 2 of 2, prepared by Sun-Tek
- Manufacturing, Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr.,
P.E., on May 08, 2012.
B. TESTS
L Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 24113.2.1, TAS 202-94
along with marked -up drawings and installation diagram of Model MD-CMA Curb .
Mounted Plastic Dome Skylight, prepared by National Certified Testing Laboratories,
Test Report No. NCTL-210-3859-1, dated 03104113, signed and sealed by Gerard J.
j Ferrara, P.E. .
C. CALCULATIONS
i 1. Anchor calculations prepared by J & L Wells Consulting LLC, 19 pages, dated
0311912013, signed and sealed by James D. Wells, Jr., P.E.
D. QUALITY ASSURANCE
1. By Miami -Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENT
1. Florida Building Code, 2010 Edition, compliance letter prepared by J & L Wells
Consulting LLC, dated 0412512012, signed and sealed by James D. Wells, Jr., P.E.
3.1 EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #15-0513.05
Al. DRAWINGS
1. Drawing #CMA-002, titled ".YID-CMA ", sheets 1 and 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated 05109111, signed & sealed by James D. Wells, Jr., P.E., on
05108112.
B: TESTS
1. None.
C. CALCULATIONS
1. None.
my A. Maker, P.E., M.S.
Product Control Section Supervisor
NOA No. 17-1023.18
Expiration Date: 03/13/2023
Approval Date: 03/15/2018
E -2
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
QUALITY ASSURANCE
1. By Miami -Dade County Department of Regulatory and Economic Resources.
MATERIAL CERTIFICATIONS
1. None.
STATEMENT
1. Florida Building Code, 2014 Edition, compliance letter prepared by J.& L Wells
Consulting LLC, dated 0510512015, signed and sealed by James D. Wells, Jr., AE.
NEW EVIDENCE SUBMITTED
DRAWINGS
1. Drawing No. CMA-002, titled "MD-CMA ", sheets I and 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr.,
P.E., on October 06, 2017.
TESTS
1. None.,
CALCULATIONS
1. None.
QUALITY ASSURANCE
1. By Miami -Dade County Department of Regulatory and Economic Resources.
MATERIAL CERTIFICATIONS
1. None.
STATEMENT
1. Florida Building Code, 2017 Edition, compliance letter prepared by J & L Wells
Consulting LLC, dated 1010612017, signed and sealed by James D. Wells, Jr., P.E.
elmy A. Makar, P.E., M.S.
Product Control Section Supervisor
NOA No. 17-1023.18
Expiration Date: 03/13/2023
Approval Date: 03/15/2018
E -3
�*t,1i�IBtt��s�
pAYID
J & L Wells Consulting LLC ``��wi��
Engineer of Record: 1453 Arbitus Circle ems' I -
- - -- -- - -James D. Wells, -Jr., P.E. - -- - Oviedo- FL-32765 - - �'- �. �36 (j -
Professional Engineer No. 53616 (407) 496-5489 ;a
Certificate of Authorization No. 27162 0�
STAVE ®F
E' D CfvA PLAN �_ s����:,"'�C�aatOP` ..•_,� b�
H�- 3.0000s910.625---1
DIMENSI❑NS F❑
FASTENER L❑CAT
14 FASTENERS
TO CURB
6 RIVETS
POLY TO ALUM
RIVET L❑CATI❑NS
RSIENER SCHEDULE SKYLIGHT TO CURB
10 X 2 PAN HEAD SHEET METAL SCRF1
PER LONC I PER SHORT
SIDE SIDE
13.625
27.256 MAX.
TENER SCHEDULE CURB
DECK #ID X 3" DECK
SCREWS
PER LONG SIDE PER SIDESHDR7
S'UmNE DLODD,G IDONUNDoS)
S)S-ID00 SUTANr BErMEFN
SKR)CHI AHD E .
(CONrDDDS)
OECD rD1�D ST O
GJDS0 IN][H ALUL�iHuN
ANDSNEiDFP LANDS
.IOY5 -IS ArwAnKn R4ef
N RE
/10 t(2 PHWlS PAN TLrAD SIIFET METAL SCDLW
1A1 ON LONG 9D[R (3) ON SHORT SiOE
AID - 3- DECK SCREE
1.) ON LOND SDE
(3) ON SHORT SIDE
c`CDN"°"Dw t°n Nrtu TxgEs (2)
DWG.#: CMA-002
our ER DONE .D70 PDLTCARBWAre
O10 POLYCARDDtaITC SHtCi
PAIRAN PAlSDM.
l Sh6fELD AUXROtON m
SNPC 1[r.D1 D03r
IWER D30 YwTrn-eo"et
PAL U T,
LETor
URAN 90340.V.
W
In
RCN
W °'
w� rsNDD WALC NAICRNL
1
er OTHM ( . ROVED
0 Ir)
DADE COUNTY)
IR SYP (50 QS GURB N%Ht TD OF
ax�nInCro i0 Nrtxi.N
or Al Ar LOAEst rraHt
D! F L i0 ROOT SURTAOE
NOTE: (APPN�OrP[oUBY D�ADe tcouNtixj
(1) ALL ROOFING DETAILS SHALL COMPLY WITH
CHAPTER 15 OF THE 2017 FLORIDA BUILDING CODE
(2) 4" MINIMUM DISTANCE FROM ANGLE LIP TO ROOF DESIGN PRESSURE RATING
SURFACE IS FOR SHINGLE. OR B.U,R. WITHOUT +— 60 PSF,
INSULATION, FOR INSULATION AND TILE ROOF ADD LARGE MISSILE IMPACT RESISTANCE
TILE HEIGHT AND INSULATION THICKNESS TO 4'
MINIMUM HEIGHT.
(3) ANCHORS TO BE MADE OF NON -CORROSIVE MATERIAL.
COMPATABLE WITH ALUMINUM.
RIVET SCHEDULE DECD
70 POLYCARBONATE 3116-
PER LONG PER SHO
SIDE I SIDE
RF I5 D
a" COrQPxy(,.T '&'*h the 0014dz
;? rceptance til0 - a Z3.18
E'V'I'aticnDate O
o�
By
ivADiR *15"
&4�_
3 ''-""' PRODUCT NAME;
,N,, MD-CMA SUN-TEK MANUFACTURING, INC.
DAT I 09 11 CALF D [t Nc� A— 10303 GENERAL DRIVE ORLANDO. FL 321324
oar® SDIma yes®�/"
J & L Wells Consulting LLC w������✓ v9� '� rs�
1453 Arbitus Circle
Engineer of Record: , OviedoFL 327_65 _ -
-- - - -- - - - — - James-D.-Wel1s; jr.-P.E, - - •� O.
Professional Engineer No. 53616 (407) 496-5489
Certificate of Authorization No.27162 =0; �alb��7� ram`
PART NAME: PROD IrT DRAWING _ _- �4� 3�i�4TE OF:
DESIGN PRESSURE RATING
+— 50 PSF
# 10 X 2" SCREW PPH LARGE MISSLE IMPACT RESISTANCE
(4) ON LONG SIDE& (3) ON SHORT SIDE
MINIMUM ENBEDMENT 1"
DECO RING STI-275
.060 THICK ALUMINUM
6063 T6 MITRE
AND WELDED CORNERS
4" MINIMUM
SEE NOTE #2
GLES (2)
2X SYP (SG 0.55) CURB HEIGHT
TO BE SUFFICIENT TO MAINTAIN
4" MINIMUM AT LOWEST POINT
OF FRAME TO ROOF SURFACE
SUPPLIED BY OTHERS AN
(APPROVED BY DADE COUNTY)
JER LINER .030 polycorbonot
(Polrom Palsun,
Sheffield Mokrolon or
Sobic Lexon 9034)
as complying with the Fioaiva
Building Code
AceepU ce No) 7
i' Xpilytion Date o Z—aa
FINISHED WALL MATERIAL
BY OTHERS ( APPROVED
DADE COUNTY)
5-1/2" DOME RISE
AIR FILLED INSULATED SPACE
#10 x 3" DECK SCREW
(4) ON LONG SIDE
(3) ON SHORT SIDE -
MINIMUM ENBEDMENT 5/8"
NOTE:
(1) ALL ROOFING DETAILS SHALL COMPLY WITH
CHAPTER 15 OF THE 2017 FLORIDA BUILDING CODE
(2) 4" MINIMUM DISTANCE FROM ANGLE LIP TO ROOF
SURFACE IS FOR SHINGLE. OR B.U.R. WITHOUT
INSULATION. FOR INSULATION AND TILE ROOF ADD
TILE HEIGHT AND INSULATION THICKNESS TO 4"
MINIMUM HEIGHT.
(3) ANCHORS TO BE MADE OF NON -CORROSIVE MATERIAL,
COMPATABLE WITH ALUMINUM.
STS-1000 SEALANT (CONTINOUS)
PRODUCT NAME, M o _ c MA
DWG.41; CMA-002
-OUTER DOME .070 POLYCAR13ONATE
(Polrom Polsun,
Sheffield Mokrolon or
Sobic Lexan 9034)
SILICONE BEDDING (CONTINUOUS)
BUTYL RUBBER SEALANT
BETWEEN SKYLIGHT
AND CURB (continuous)
SHIM® EA, ANCHOR (TYP)
WITH LOAD BEARING SHIM
1_ 0.500 MAX.
I3/ 16" RIVET
)/LONG SIDE
1 /SHORT SIDE
FLASHING BY OTHERS IN
ACCORDANCE WITH NRCA
ROOF DECK
SUN-TEK MANUFACTURING, INC.
10303 GENERAL DRIVE ORLANDO. FL 32824
Co O /