HomeMy WebLinkAboutEVALUATION REPORT - UNDERLAYMENTSMEMO j etc. Certificate ofAuthorizatlon #32455 353 Christian Street, Unit #13 Oxford, CT 0647.8 (203) 262-9245 EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT Polyglass USA, Inc.. Evaluation Report P12060.02.09-R24 1111 West Newport Center Drive SCANNED F1.5259-1128 Deerfield Beach, FL 33442 BY Date of Issuance: 02/24/2009 (954) 233-11230 St Lucie County Revision 24: 004/2018 SCOPE: I - This'Evaluation Report is issued under Rule 61620-3 and the applicable rules and ' regulations governing the use of . construction materials in the State of Florida..The documentation submitted has been reviewed by Robert Nieminen, P.'E. for use of'Ithe product under the Florida Building Code and. Florida Building Code, Residential Volume.. The products described herein have been evaluated for compliance -with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof. Underlayments LABELING: Llabeling shall:be in .accordance With the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the namedproduct(s) changes, the• referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of.this Evaluation !Repo.rt by the named client constitutes agreement to notify Robert Nieminen; P.E..of any changes, to the product(s),i the Quality Assurance or the production facility location(s). NEMO l etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADvERTisEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed -in advertising literature. If any portion of the Evaluation -Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the.request of the.Building Official. . This Evaluation-Reportconsists of pages 1 through 14. Prepared Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE2983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 01/24/2018. This does not serve as an electronically signed document CERTIFICATION OF INDEPENDENCE: 1. NEM01 etc. does not have, nor does it intend to acquire or will it acquire, a financial. interest in'any company manufacturing or distributing products it evaluates. 2. NEMO J etc. is not owned, operated or control by any company manufacturing or distributing products it evaluates. 3. . Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports. are being issued.. 4. Robert Nieminen,.P.E. does not have, nor will acquire, a financial interest in any other entity involved In the approval process of the product. . 5. This is a .building code evaluation. Neither. MEMO I etc. nor Robert Nieminen, P.E. are, in. any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. O.-NEMOletc. ROOFING COMPONENT EVALUATION: I 1. SCOPE: Product Category: Roofing. Sub -Category: Underlayment Compliance Statement:- Roof Underlayments, as produced byPolyglas;-US , l c., Piave demonstrated compliance with the following sections of the oh Edition (2027).Florida Building. Coe rough testing in accordance with the following Standards. Compliance is subject to the Installation, Requirements.and Limitations / Conditions of Use.set forth herein. 2. STANDARDS: Section property Standard Year 150413.1 Wind Uplift FM 4474 2011 150413.1 Wind Uplift UL 1897 2012 150712.3 / 1507.1.1 Physical Properties ASTM D226 . 2009 150712.4 / 1507.1.1, 1507.2.9.2 Physical Properties ASTM' D1970 2025 . 1507!3.3 Physical Properties FRSA/TRI April 2012 2012 15071,11.2 Physical Properties ASTM D6164 2011 1507111.2 Physical Properties ASTM D6222 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Enti Examination Reference Date FM Approvals (TST 1867) Wind Uplift 3004091 01/12/2000 PRI (TST 5878) Physical Properties PRIC1111 04/08/2002 PRI (TST 5878) Physical Properties PUSA-005=02-01 01/31/2002 PRI (TST 5878) Physical Properties PUSA-013-02-01 .12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-02 12/23/2002. PRI (TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI (TST5878) Physical Properties _ PUSA-018-02-01. 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 07/23/2005 PRI (T57 5878) Physical Properties, PUSA-033-02-01 01/12/2006 PRI (TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI (TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI (75T 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI.(TST 5878) .Physical Properties PUSA-076-02-01 02/22/2008 PRI (TST 5878) Physical Properties PUSA=083-02-01 04/14/2008 PRI (TST 5878) Physical Properties PUSA-088-02-01 . 07/29/2009 MTI (TST 2508) Physical Properties JX20H7A 04/01/2008 MTI (TST2508) Physical Properties RX14E8A 01/29/2009 ERD (TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD (TST 6049) Wind Uplift 11757.08.01-1 08/13/200.1 ERD (TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD (TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD i(TST 6049) Wind Uplift P1740.01.07 . 01/04/2007 ERD (TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD !(TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD;(TST6049) Physical Properties P13450.08.09 08/13/2009 ERDI(TST6049) Wind Uplift P30540.11.09-R1 11/30/2009 ERD (TST 6049) Physical Properties . P11030.11.09-1 12/30/2009 ERDI(TST.6049) Wind Uplift P11030:11.09-2 11/30/2009 ERDI(TST6049). Physical Properties P11030.11.09-3 11/30/2009 ERDI(TST6049) Physical Properties P33360.06.10 06/25/2010 ERD (TST 6049) Physical Properties P33370.03.11 03/02/2011 ERD (TST 6049) Physical Properties 033370.04.11 04/26/2011 ERD'I(TST 6049) Physical Properties P37300.10.11_ 10/19/2011 NEMO ETC, LLC. Evaluation Report P12060.02.09-1124 Cer0rt—!ofAuth0&.t1on #32455 C" EDITION.(2017.) FBC NON-HVHZ EVALUATION F1.5259-1128 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 2 of 14 ERD ERD ERD ERD ERD ERD ERD ERD ERD ERD ERD ERD, ERD ERD ERD• ERD ERD ERD ERD ERD ERD ERD ERD ERD ERD ERD ERD ERD ERD UL, 6049) 6049) 6049) iT 6049) iT 6049) iT 6049) iT 6049) iT 6049) iT 6049) iT 6049) iT 6049) iT 6049) . iT 6049) iT 6049) iT 6049) . iT.6049) iT 6049) iT 6049) iT 6049) iT 60491 iT 6049) iT-6049) iT 6049) iT 6049) . iT 6049) 5T 6049) iT 6049) . . iT 6049) (EVL 2396) -Dade (CER 1592) iss USA ass USA iss USA. :. (QUA9625) 4. PRODUCT DESCRIPTION: Examination Physical Properties Physical Properties Physical Properties Wind Uplift Physical Properties Wind Uplift. Wind Uplift Wind Uplift Wind Uplift Wind Uplift Physical Properties Physical Properties, Physical Properties. Physical Properties Physical Properties Physical Properties. Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties - Physical Properties . Wind Uplift Physical Properties Wind Uplift Physical Properties Physical Properties Physical Properties IBC Compliance HVHZ Compliance Manufacturing Affidavit P/L Affidavit Materials Affidavit Quality Control Reference P40390.08.12-1 P40390.08.12-2 C41420.09.12-3 P39680.03.13 P45370.04.13 . P1738.02.07-R2 11757.04.01-1-R1 P41630.08.13 P11751.05.03-111 P11781.11.03-R1 P45270.05.14 6020.07.14-1. 6020.09.14-2 6020.09.14-3 6020.09.14-4 6020.09.14 5 6020,09.14-6 P46520.10.14 P43290.10.14 PLYG-SC7550.03.15 P40390.04.15 P44360.10.14-R1 PLYG-SC8080.05.15-1 PLYG-SC8905.05.16-1 PLYG-SC8080.07.16 PLYG-SC12025.10.16 PLYG-SC13640.12.16 PLYG-SC11900.03.17 PLYG-SC12115.08.17 ESR-1697 NOA 14-0717.08 Products Current Mule -Hide Cross Ltg Polystick SA Compound. Service Confirmation a Mechaplcally Fastenetl'Untlerlayments 4.1A Elastobase is a fiberglass reinforced,•SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet.. 4.1.3 Polyglass 62 Base is a fiberglass -reinforced, asphaltic base sheet. i 4.1.4 Polyglass APP. Base is a fiberglass -reinforced,. APP. modified bitumen base sheet. i 4:2 . :Self=Adhering Underlayments X, ONEMO etc. Date 08/06/2012 08/07/2012 09/11/2012 03/04/2013 04/26/2013 04/29/2013. 04/30/2013 08/06/2013 12/26/2013 11/26/2013 05/12/2014 09/08/2014 09/08/2024 09/08/2014 09/08/2024 09/08/2014 09/08/2014 10/03/2014 10/17/2014 03/24/2025 04/03/2015 05/18/2015 05/20/2015 05/17/2016 07/16/2016 10/12/2016 12/27/2016 03/10/2017 08/08/2017 11/01/2014 01/22/2015 02/19/2009 03/01/2008 08/18/2011 Exp.10/05/2018 4.2.2 . Polystick IR-Xeis a nominal 60-m. , y it thick rubberized asphalt waterproofing membrane; glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. NEMO ETC, LLC. Evaluation Report. P12060.02.09-R24 Certificate ofAutharization #32455 &P EDITION (2017) FBc NON-HVHZ EVALUATION FL5259-R28 P.olyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 3 of 24 O.NEMOletc. 4.2.4 Polystick TU P is a nominal. 130-mil thick rubberized asphalt waterproofing membrane,. glass=fiber/polyester reinforced, with a granular surface; meets "FRSA/TRI April 2012. 4.2.5 Polyst)ck TU Max is a, nominal 60=mil thick rubberized asphalt waterproofing membrane with a.190.g/M2 polyester fabric surface; meets ASTM D3970 and FRSA/TRI April 2012: I 4.2.6 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet, and Mule -Hide SA-APP Cap Sheet.(FR) are polyester . reinforced, APP modified .bitumen cap sheets; meet FRSA/TRI April 2012. . 4.2.7 Polystick Dual Pro'" is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a "polyester fabric surface; meets ASTM D1970: 4.2.8 Polystick Tile Pro'" is a "nominal 60-mil thick "dual -layer rubberized asphalt waterproofing membrane, fiberglass, reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI'April 2012. . 4.2.9 Polystick MU-X".is. a nominal " 54-mil thick, dual -layer rubberized asphalt waterproofing membrane,. fiberglass reinforced,,with'a polypropylene film surface; meets"AC188 and physical, requirements of ASTM D1970 (See Section 4:3" "• Mechamcall Fastenedand/ori"ded"Undedayments: 4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an alternate to "Mineral Surface. Roll. Roofing" (ASTM D6380, Class.M) in the "Single Ply System" -from FRSA/TRI April 2012 (04-12) beneath" mechanically fastened the roof systems or Hot Asphalt applied "Cap Sheet"'in the Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered file roof systems. " 4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; "meet ASTM D6164. . i Elastofiex S6 G and Elastoflex S6 G FK are for use as an alternate to "Mineral Surface Roli Roofing" (ASTM" D6380, -Class M) in the "Single Ply System" from FRSA/TRI.Apri12012 (04-12) beneath mechanically fastened the roof systems. Elastoflex S6 G is for use as an, alternate to Hot Asphalt applied "Cap Sheet" in. the "Two. Ply System" -from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered -tile roof'systems.."Elastoflex S6 G FR -is for use as an alternate''to Hot Asphalt applied- "Cap Sheet" in the "Two Ply System from. FRSA/TRI.April .2012. (04-12) beneath mechanically fastened tile roof systems. 4.3.3 Polyflex G. and .Polyflex G. FR are polyester reinforced, APP modified, bitumen cap sheets; meet ASTM D6222. Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the: 'Two'Ply System" from FRSA/TRI April 2012. (0412) beneath mechanically fastened or adhered tile roof systems. Polyfle'x G"FR is for use as an alternate to Heat Applied,"Cap Sheet" in. the `Two Ply System" from FRSA/TRI April 2012 (04-12) beneath. mechanically. fastened the roof systems., 5. LIMITATIONS: 5.1 This Is a building code• evaluation. Neither NEMOJ etc. nor Robert Nieminen,. P.E. are, in any way, the Designer of " Record for any project on which this.Evaivation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report Is not for use in the HVHZ. 5.3 Fire Classification Is not partof this Evaluation Report, refer to current Approved. Roofing Materials Diirectory_for.fire ratings of.thisproduct. 5.4 i Polyglass Roof.Underlayments may be used with.any prepared roof cover.where the product Is specifically referenced within FBC approval .documents. If not listed, a request may be .made to the Authority Having. Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. i NEMO ETC, LLC. " Evaluation Report P12060.02.09-R24 ceruflrnte ojAuthot&at/on N32455 O EDI710N (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 4 of 24 ONEMOjetc. 5.5 i Allowable Roof Covers: 16OF:COVER OPTIONS UndMayment Asphalt Shingles Nail -On The Foam -On Tile Metal Wood Shakes & Shingles Slate Elastobase Y� Base sheetYn2- I es ( p y system) Yes (Base Sheet In 2-ply system) Yes Yes Yes Elastobase P Yes Yes (Base Sheet In 2-ply system) Yes (Base Sheet in 2-ply system) Yes Yes yes Polyglass G2 Base No ' Yes (Base Sheet in 2-ply system) Yes (Base Sheet In 2-ply system) No No No Polyglass APP Base No Yes (Base Sheet in 2-ply system) Yes (Base Sheet In 2-ply system) - No No No IgStic S or MTS PLUS Ye Yes Yes No noYe ' Yes Yes Po ystick IR-Xe No No No Yes Yes Polystick TU P No Yes Yes (See 5.5.1) No No No Polystick TU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes PolystickTUMax No Yes Yes (See 5.5.1) Yes No No Polykck Dual Pro Yes No No Yes Yes . Yes Polystick Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick MU-X Yes No No Yes Yes Yes Elastoflex S6 G Yes Yes Yes (See 5.5.1) No Yes Yes Elastoflex S6 G FR Yes Yes No No Yes Yes Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes PolyfjexG Yes Yes Yes (See5.5.1) No Yes Yes Polyflex GFR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Yes Yes Yes (See 5.5.1) No Yes Yes 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. TABLE 1A: ALLOWABLEML.E ADHESIVE UNDERLoMi N CONtBINATIONS .' Adhesive Florida Product Underlayments Approval DAP Foam Touch 'n Seal StormBond Roof FL14506 Polystick TU Plus, Polystick TU Max Tile Adhesive DoW TileBondTM FL22525 Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Adhesives Polyset® AH-160 F1.6332 Elastoflex G TU, Elastoflex 56 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Adhesives Polyset" RTA-1 FL6276 Elastoflex G TU, Elastoflex 56 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) 2 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R24 Certificate of Authorization 932455 6t" EDITION (2017) FBC NON-HVHZ EVALUATION FL52S9-R28 Polyglass Roof Underlayments, (9S4) 233-1230 Revision 24: 01/24/2018 Page 5 of 14 5.6� 5.6.1 1 5.6.3 -ONE-Wjetc. Allowable Substrates: Direct=Bond to Deck-' Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to- > New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D4.1 primed existing plywood; New or existing, unprim - ed. OSB; ASTM D41 primed OSB;.Southern Yellow. Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels (designed andinstalled to meet Wind loads for project). Note: Polyglass does. not: require Priming of new or existing plywood or OSB sheathing. New or existing plywood or . OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. -Elastoflex GT.U,-ElastoflexS6,G,or Elastoflex S6 G FR in hot asphalt to: >.➢ ASTM D41 primed structural concrete. Polyflex d or Polyflex G FR torch -applied to: >'ASTM: D41 primed structural concrete. Band-tot-Insulatiom. Polystick (all'Vaditions),- Polyflex SAP or -SAP FR, M4le-Hide'SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: > ASTM C1289, Type [I, Class 1 p 'olyi ocyanurate' or Type V polyisocVanurate-composite insulation; Dens Deck s DuraGuard; Dens Deck Prime; dr-SECUROCKGypsum-Fiber Roof Board. Elastoflex G TU, Elastoflex S6G.orElas.toflekS6G FR in hot asphalt to: > Dens Deck Prime or SECURO,CK Gypsum -Fiber Roof Board. .... .. Polyflex,G or Polyflex G FR torch -applied to: > ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically -attached prepared roof coverings, Insulation shall be attached.pdr minimum - reiluirements of the.prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems, insulation attachment shall be designed by a'qualified design professional and ,installed based on testing of the insulation/underliyment system in accordance with FBC Section 1504.3.1. Bond to Mechanically Attached Base Layer: Polystick . (all. variations), Polyflex SAP or SAP FR, Mule -Hide. SA-APP Cap Sheet or SA-APP Cap Sheet (FR)'Dual Pro or Tile Pro self-aidhered.to:' -> ASTM D226, Type I . or-11 felt;. Elastobase; Elag@Sise P or Mule -Hide Nail- Base.. Elastoflex IS TU,- Elastoflex S6 G or.Elastoflex S6 G FR in hot asphalt to: > . ASTM D226, Type e I or 11 felt, Elastobase; Elastobase P, Mule -Hide Nail Base, or Polyglass'G2.Base. Polyflex G or Polyflex G FR torch -applied to: > Elastobase; Elastobase P,_ Mule -Hide Nail Base, Polyglass G2'Base or Polyglass APP Base. For installations under mechanically attached prepared roof coverings, -base layer.shall be attached per minimum codified requirements. :For installations under foam -:on tile systemi,.Oase layer shall, be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein,- or as tested in - accordance with FBC Section 1504.11. NEMOETC, U.C. lival - uation Report P12060.02.09-R24 I Certificate ofAutharizaMn 432455 e EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 PoIVgIass Roof Underla4menits, (954)233-1230 Revision 24:01/24/2018 Page 6 of 14 1 ONEMOletc. 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does.not address wind uplift resistance of all underlayment systems beneath foam -on the systems, where the.underlayment . forms part of the load:path.' The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure Is the result of testing for wind. load resistance based on allowable wind'loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).Refer to FRSA/TRI April 2012 (04- 12), Append)x A, Table 1A or FBC 1609 for determination of design wind loads. #1 'Maximum Design Pressure -90 psf: Deck: Min. IS/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus,.Polystick TU Max, Polyflex SAP, Polyfle,x SAP FR, Mule -Hide SA-APP Cap Sheet and Mule=Hide SA-APP Cap Sheet (FR), self -adhered. #2 Maximum Design Pressure = -97.5 Dsf: Deck: Min..15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or. Polystick MTS PLUS, self -adhered. Underlayment:• Polystick TU P; •Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x . 1Y.." ring shank nails through 32 ga:,1-5/8" diameter tin caps spaced 12-Inch o.c, #3 Maximum Design Pressure = 405 DO Deck: Min. 15/327inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000. Base. Ply:: (Optional) Polystick MTS or Polystick MTS PLUS; self -adhered. Underlayment: Polystick TU P, Polystick TU Plus,.Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA APP Cap Sheet and Mule Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y," ring shank'nails'through 32 ga.,1-5/8" diameter tin caps spaced 12-Inch o.c. #4 Maximum Design Pressure = -235 psf Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)PG100orASTM,D41 Base Ply:: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP. FR, Mule -Hide SA APP Cap Sheet and Mule -Hide SA=APP Cap Sheet.(FR), self -:adhered. #5 Maximum Design Pressure = -315 psf, Deck: - Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG 100 or ASTM 641 Base Ply: (Optional) Polystick MTS or'Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered: #6 Maximum Design Pressure = -622.5 Dsf: . Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100orASTM D41 Underlayment: Elastoflex G TU or.Elastoflex S6'G1 applied.in full mopping of hot asphalt or Polyflex G, torch -applied.. . #7 Maximum Design Pressure = -30:0 Dsf*:. . Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase'or Mule -Hide. Nail Base (poly -film top surface)" Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing:.. . 6-inch o:c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional)-Polystick MTS.or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR; Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self=adhered. NEW ETC, I.I.C. Evaluation Report P12060.02.09-R24 CerGflcate ofAutharization #32455 . - 6T" EDITION (2017) FBC NON-HVHZ EVALUATION - FL5259-R28. Polyglass Roof. Underlayments; (9s4) 233-1230 Revision 24: 01/24/2018 Page 7 of 14 #9 #10 #12 #13 #14' IINNEMO etc. Maximum Design Pressure = -37.5 psf*: Deck:- Min.15/32-inch plywood to meet project requirements to satisfaction of Authority'Having.lurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) .. Fasteners: 11 ga. x 1,25-inch long x 1-inch head diameter round metal cap nails. , Spacing: 6-inch o.c, at the 3-inch wide side laps and 6-Inch o.c. at two (2) equally spaced staggered center rows. Base Ply:. (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU .P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet.and Mule -Hide SA-APP Cap Sheet (FR), self -adhered: Maximum Design Pressure = -37.5 psf*: Deck: Min..19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet:. One (1) or two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch long x -1-inch head diameter round metal cap nails " Spacing:. 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2). equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. Maximum Design Pressure = -45 psf*: . Deck: Mina 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) layer ASTM D226, Type 11,felt Fasteners: 11 ga.'x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter. tin caps Spacing: 4-inch o.c. at the 2-Inch wide side laps and 4-inch o.c: at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU, applied In full mopping of hot. asphalt: Maximum Design. Pressure = -45 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. . Base Sheet: Two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1=5/8-Inch diameter tin caps Spacing: 9-inch o.c. at the 2-Inch wide side laps and 9-inch o.c. at two (2). equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Pius, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU,or Elastoflex S6 G, applied in full mopping of hot asphalt.. . . Maximum Design- Pressure = -45 osf Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having jurisdiction.,, Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners ' Spacing:... . 9-inch o.c. at.the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. Maximum Design Pressure = -52.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: - Elastobase (sanded top surface. for hot -asphalt or torch -applied -cap or poly-filrn surface for.torch=applied cap) Fasteners: Simplex MAXX Cap Fasteners' Spacing:: 9-Inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment; Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hat asphalt or,Polyflex G, torch -applied. Maximum Design Pressure = -52.5 psf: Deck: Min. 15/32-inch'plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex Original Cap Nails Spacing: 64nch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Base Ply:. (Optional).Polystick.MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and. Mule -Hide SA-APP Cap Sheet (FR),-self-adhered. NEMO ETC, I.I.C. Evaluation Report. P12060.02.09-1124 CertbYcate ofAuthorizatfon A32455 6TM EDITION (2017) FBC NON-HVH2 EVALUATION FL52594t28 Polyglass Roof Underlayments, (954) 233-123Revision 24: 01/24/2018 .0 _ Page 8 of i4 #15 Maximum Design Pressure = -52.5 Dsf: Deck:.. Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the'3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G.TU or Elastoflex S6 G, applied in full -mopping of hot asphalt or Polyflex G, torch -applied. #16 Maximum Design Pressure = -60 Dsf: Deck: Min.19/32-inch plywood to"meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface fortorch-applled cap) Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter.tin caps Spacing: 87inch o.c. at the 4-Inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, "torch -applied. #17 Maximum Design Pressure = -60 Dsf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.. - - Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12-inch o.c. at the 4-Inch wide side laps and 12-inch ox. at two"(2) equally spaced staggered center rows. Underlayment: Elastoflex.G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #18 Maximum Design Pressure = -67.5 psf: j Deck: Min. 15/32-inch" plywood to meet project requirements to satisfaction of Authority HavingJurisdiction. Base Sheet: Polyglass G2.Base or Poiyglass APP Base (requires use of torch -applied underlayment) Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/84nch diameter "tin caps Spacing:. 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally -spaced staggered. center. rows: . Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch - applied.. #19 Maximum Design Pressure = -75 psf Deck: -Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction:. Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG TGolvalume.Steel Plates, OMG Roofgrip #14 with OMG flat.Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates -or Simplex MAXX Cap Fasteners Spacing:' 10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows." Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch - applied. . #20 I Maximum Design Pressure = -90 Dsf: Deck: Min: 15/32-inch plywood to meet project requirements to satisfaction of Authority. Having Jurisdiction. Base Sheet: Elastobase (sanded.top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex.MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Underlayment:. Elastoflex G TU or Elastoflex S6 G,.applled 16 full mopping of hot asphalt or Polyflex G, torch -applied. #21 i, Maximum Design Pressure =-90 Dsf:' " Deck Min. 15/32-4nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OiVIG #12 Standard Roofgrip or OMG #14 Heavy, Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal " . Plates r Spacing:. 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.. Underlayment: Elastoflex G TU or Elastoflex S6 G,, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #22 Maximum Design Pressure = -90 Dsf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction: Base Sheet:. Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: " 6-inch o.c. at the'44nch wide side laps and 6-inch o.c. at three (3).equally spaced staggered'center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. NEMO ETC, I.I.C. Evaluation Report P32060.02.09-1124 Certificate ofAuthorization #32455 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 9of14 #231 #24 I #25 #26 #27 �I #28 f0NEM0.1.ett. Maximum Design Pressure = -90 psf Deck:. Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction: Base Sheet: Polyglass G2 Base or Polyglass APP Base.(requires use of torch-opplied underlayment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with'OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with CMG Flat Bottom Plates (Accarac),.Trufast HD with. Trufast'3-inchInsulation Plates or Simplex MAXX .Cap Fasteners Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.- . Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in'full mopping of hot asphalt or.torch-applied or Polyflex G, torch-. applied. Maximum Design Pressure =-97.5 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film tap surface) Fasteners: • • 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch. diameter tin caps Spacing: 4-inch o.c. at the 4-inch'wide side laps and flinch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS.PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max,.Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule=Hide SA-APP Cap Sheet (FR), self -adhered. Maximum Design Pressure = -105 psf. . Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-Inch o.c. at the 2-inch wide side laps and.6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU.or Elastoflex S6 G, applied in full mopping of hot asphalt or, Polyflex G,,torch-applied. Maximum Design Pressure = -112.5 psf: Deck. Min'.,19/32-inch plywood.to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)' . Fasteners: 11 ga. x 1.25-Inch x 3/8-inch head diameter annular ring shank roofing, nails. at 1-5/8-inch diameter tin caps Spacing: 6-1nch o.c. at the'4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin -caps Base Ply: Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA APP Cap Sheet (FR), self -adhered. Maximum Design Pressure = -120 psf: - Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: •Elastobase.(sanded top surface for hot -asphalt or -torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG .#12.Standard.Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates . Spacing: . 6=inch o.c. at the, 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.-. Underlayment: Elastoflex.G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. Maximum Design Pressure = -120 psf . Deck: Min'.15/32-irich plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) . Fasteners: Trufast#12 DP orTrufast#14 HD with Trufast 3" Metal Insulation Plates Spacing: . 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows. Underlayment:.Elastof16 G TU.or. Elastoflex S6 G, applied in full mopping of hot asphalt. All other. direct -deck, adhered. Polyglass underlayment systems beneath. foam -on the systems carry a Maximum Design Pressure of-45 psf. NEMO ETC, LLC. Evaluation Report P12060.02:09-1124 Certificate of Authadzatbn #32455 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZR Polyglass Roof Underlayments; (954) 233-1230 -Revision 24: 01/24/2018 .. Page.10 of 14 I f0NE]M0jlAC. 5.6..2 For mechanically attached. Base. Sheet; the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. . Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design. pressure determined in accordance. with FBC 1609. In this case, Zones 2 and 3 shall employ an 'attachment density designed by a qualified. design professional to resist the elevated pressure criteria. Commonly used methods, are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29' and Roofing Application Standard RAS 117. Assemblies marked with an asterisk's carry the limitations. set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone .2/3 enhancements: . 5.7 Exposure Limitations: Elastobase; :Elastobase P, Polyglass G2 Base. or Polyglass APP Base shall not be left exposed for longer than .30-days . after installation. Polystick IR-Xe or. Polystick MU-X shall not be left exposed for longer than 90-days after installation. Polystick MTS;.MTS.PLUS, TU P, TU Plus,TU Max; Dual Pro, Tile Pro or Elastoflex G.TU shall not be.left exposed for longer than 180-days after. installation. Polyflex SAP or SAPFR, .or Mule -Hide SA-APP. Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering Is to be adhesive -set tile, in which 'case the maximum exposure is 30 days. Elastoflex S6 .G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have. an exposure limitation, unless the .prepared roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only),. in which case the maximum exposure is 180 days. . 5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient'of friction. than ASTM D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth. in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance. 5.9 Tile Slippage Limitations (FRSA/TRI April 2012 (04.42)): when loading roof tiles on the underlayment-in direct -deck tile assemblies, the maximum roof slope shall be as $illnum ThPcp chine limitations can -only he exceeded by using'battens during loading of the roof tiles. Tg8LF;2:.TILE.SLIPPAGE UMITAT10N5FOR DIR�GT• DEGKTILEINS7ALLATIONS.. Underlayment Tile Profile Staging Method Maximum Slope Elastoflex G TU . I Flat 10-tile stack 7:12 . Lugged RAlle stack (6 over 2) 6:12 . Elastoflex S6 G or56 G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polystick MTS or MTS PLUS . Flat 6-tile stack (4 over 2) 5:12 Lugged &tile stack (4 over 2) 4:12 Polystick Tile Pro Flat or Lugged, 6-tile stack (4 over 2) 7:12 Polystick TU Max Flat 6-tile stack (4 over 2) or 10-tile stack 7:12 Lugged 6-tile stack (4 over 2) 7:12 Lugged: 10-tile stack 6:12 Polystick TU P Flat 6-tile stack (4 over 2) 6:12 Lugged 6-tile stack (4 over 2) 4:12 Polystick TU Plus I. Flat or Lugged 6-tile stack (4 over 2) 7:12 Flat or Lugged ' . 104ile stack 6:12. Poly(Iex,G or G FR Flat or Lugged, 6-tile stack (4 over 2) ' 4:12 Poly(lex SA P o -SA P FR Flat or Lugged 6-tile stack (4 over 2) 4:22 NEMO ETC, LLC. Evaluation Report P12060.02.09-1124 eeri ate of AuthodwtFan #32455. GP EDITION (2017) FBC NON-HVHZ EVALUATION FL52S9-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 11 of 24 i ONEMOJetc. 6. INSTALLATION: 6.1 Polyglass .Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6:3 Elastobase Elastoi>Iase PorMule-H(de Nail ease:. Non Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D226, Type If underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1. 6.3.2 Tile Applications: Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the 'Two Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with FRSA/TRI April 2012 (04-12) Installation. Manual. 6.4 lystie[ fyfT , MTS PLUS, IR=Xe, TU.P, TU P.lus, TU Max, Dua(%Pro, Tile Pro or MU X or•Polyflex SAP, Polyflex SAP FR; Mule-Hide`SA APP Cap Sheet orMule-Tilde SA APP Cap Sheets FR) { 6.4.1 Shall be installedin compliance with the codified requirements for ASTM D1970 (except Polystick TU P) underlayment 6.4.2 in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Direct -to -Deck with Mechanically Fastened Roof Covers: All self-adhering'materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be. back -nailed in selvage edge seam in accordance with Polyglass / Mule - Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back - nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back -nailed. All seal -lap seams (selvage laps) must be firmly rolled with a. minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to; the end of the glue pattern (the sheet will overlap the fabric). View of Ovelap Seam of Dual Pro and Tile Pro All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap. Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application_ such as crickets, exposed valleys, or exposed roof to wall details NEMO ETQ, U.C. Evaluation Report P12060.02.09-R24 Cert!lflcare ofAurhorLmdoo #32455 67X EDITION (2027) FBC NON-HVHZ EVALUATION . FL5259-R28 Polyglass Roof Underlayments; (9541233-2230 Revision 24: 02/24/2018 Page 12 of 14 NEW j etc. Repair of Polystick membranes is.to be accomplished by applying Polyplus.50 Premium Modified Wet/Dry.Cement or Polyglass P6500 Modified Cement-to.the area in need of repair, followed by a minimum 6 k 6 inch patch of the Polystick material of like kind, set, and hand rolled In place over .the repair area. Patch laps,_ if. needed, shall be installed in a water shedding manner. All Polystick membranes. shall .be installed to ensure full, .contact with approved substrates. Polyglass requires a" minimum of 40-lb weighted -roller or; -on steep slopes, use of a stiff broom with approximately 40-I4s of load applied •. for.the field membrane.Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. _ 6.4.3 Tile Applications (not allowed for Polystick Dual P% IRXe or Polystick MU X): . Reference is made to FRSA/TRI April 2012 .(04-12) Installation Manual and Table I. herein, using the instructions noted.above as a guideline. For mechanically fast roofing over 2-ply system; consisting of Base Sheet and self -adhering -top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04712), Table 1. For adhesive -set tile applications, refer to Section 5.6.4 herein.. 6.4.4 Two (2) Ply Underlayment Systems: Polystick MTS or: MTS PLUS'followed by Polystick MTS, MTS. PLUS,TU P, TU Pius, TU Max, Tile Pro, MU-X or Polyflex SAP is allowable for. use under.mechanically attached prepared roof systems.. Limits -of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2- ply underlayment system is desired. . Polystick MTS or MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP isallowable for use under foam -on the systems. Limits of use are'those associated with.the top -layer. material. This is not.a requirement, . j but is allowable if a 2-ply,underlayment system is desired. E{a toflex G7U, Elastaf(ex S6:G oKIastof1eX56 G Fii 6.5A Elastoflex G TU, Elastoflex S6 IS or.Elastoflex S6 G. FR shall .be.installed in compliance with. current Polyglass published installation requirements.. For use in tile applications: j ✓ Elastoflex G TU is for use as an alternate to "Mineral Surface.Roll.Roofing" (ASTM D6380, ClassM) In the "Single. Ply System" from FRSA/TRI April 2022 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied--'.'Cap.Sheet" in the "Two Ply System" .from FRSA/TRI April 2012 (04-12) beneath mechanically, fastened or adhered tile roof systems. ✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System"from FRSA/TRI April. 2012 (04-12) beneath mechanically fastened tile, roof systems or the Hot Asphalt . .. applied"Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12).beneath mechanically. fastened. or adhered tile roof systems. ✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single . Ply System" from.FRSA/TRI -April 2012 (64-12) beneath mechanically fastened tile roof systems or the•Hot Asphalt applied "Cap Sheet" in the `Two Ply'System"from FRSA/TRI, April 2012 (04-22).beneath mechanically fastened tile roof systems. 6.5. . For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6. G FR shall.be fully asphalt -applied to.the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set. minimum 3'feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.6:1 Polyflex.G or. Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use in file applications:..... j ✓ Polyflex G is for use as an alternate to.the Heat Applied,"Cap Sheet" in the "Two PIy. System" from FRSA/TRI April 2011(04-12) beneath mechanically fastened or'adhered tile roof systems (Base Sheet Limited per 5.6.3). ✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap, Sheet" irl the."Two Ply System" from FRSA/TRI. April 2012 (04-12) beneath mechanically fastened the roof systems (Base Sheet Limited per 5.6.3). NEMO ETC, I.I.C. Evaluation Report 1312060.02:09-R24 Certificate i fAuthodzation A324W e. EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230_ Revision 24: 01/24/2018 Page 13 of 14 i 7. 8. NEMO l etc. 6.6.2 Polyflex G. or Polyflex G. FR shall be fully torch -applied to, the substrates. noted In Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course., Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyondthe lap edge. 6_7 Tile Stanina: . 6.7.1 Tile shall be loaded and staged In a manner that prevents tile slippage and/or, damage to the underlayment.. Refer to Table 2 herein, and Polyglass published requirements for the staging., 6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof slopes greater than 7:12.. Precautions should be taken .as needed, such as the use of battens or nail- ' boards, to prevent tle sliding and/or damage to the underlayment during the loading process.. 6.7.3 Polyglass.specifies the minimum .cure .time after installation of .self'adhering membranes and. before loading of roofing tiles is forty-eight (48) hours. BUILIDING PERMIT REQUIREMENTS:.. . As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate'the installation of this product. MANUFACTURING PLANTS: . Contact the noted QA agency for information on product locations covered for F.A.C. 61620-3 QA requirements..The following olants have aualified oroducts under their respective physical properties specifications. Plant .:.. • ' �.:' 7. 8. NEMO l etc. 6.6.2 Polyflex G. or Polyflex G. FR shall be fully torch -applied to, the substrates. noted In Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course., Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyondthe lap edge. 6_7 Tile Stanina: . 6.7.1 Tile shall be loaded and staged In a manner that prevents tile slippage and/or, damage to the underlayment.. Refer to Table 2 herein, and Polyglass published requirements for the staging., 6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof slopes greater than 7:12.. Precautions should be taken .as needed, such as the use of battens or nail- ' boards, to prevent tle sliding and/or damage to the underlayment during the loading process.. 6.7.3 Polyglass.specifies the minimum .cure .time after installation of .self'adhering membranes and. before loading of roofing tiles is forty-eight (48) hours. BUILIDING PERMIT REQUIREMENTS:.. . As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate'the installation of this product. MANUFACTURING PLANTS: . Contact the noted QA agency for information on product locations covered for F.A.C. 61620-3 QA requirements..The following olants have aualified oroducts under their respective physical properties specifications. Plant .:.. • ' �.:' :`So�cificat'io • „ `>���`• ;Product s Fernley,. NV, Hazleton, PA & Winter Haven, FL ASTM D1970 Pol stick.MU-X. Hazleton, PA M-D.13-.0004 • Elastoflex G TU i Hazleton, PA & Winter'Haven, FL j ASTM D1970 Polystick IR-Xe ASTM b1970 &•FRSA/TRI April 2012 Polystick TU Plus ASTM D1970.& FRSA/tRl April 2012 Polystick TU Max . Tuscaloosa, AL ASTM D4601; Type II Polyglass G2 Base Winter Haven, FL ASTM D226 (physicals) Elastobase, Elastobase P ASTM D6509 Polyglass APP Base FRSA/TRI April 2012. Polystick MTS, Polystick MTS PLUS FRSA/TRI April 2012 'PolystickTU P FRSA/TRI April 2012 Polyflex SAP, Polyflex SA P FR ASTM D1970 Polystick Dual,Pro ASTM D1970.& FRSA/TRI April M12 Polystick Tile Pro ASTM D6164 Elastoflex S6, Elastoflex S6 G FR ASTM D6222 Polyflex G, Polyflex G FR 9. QUALITY ASSURANCE ENTITY: LIL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - . I MEMO ETC, LLC.' CeWfleate'af Autharizatlon H32455 I 6TM EDITION (2017) FBC NON-HVHZ EVALUATION Polyglass Roof Underlaymetns; (954) 233-1230 Evaluation Report 1312060.02.09-1124 FL5259-RZ8 Revision 24: 02/24/2018 Page 14 of 14