HomeMy WebLinkAboutNOA - ULTRA WIND - WATER SEAL%;
525
(in
if'it
in
Of
OCT 2 4 Z018
ST. Lucie County, Perm
NT OF REGULATORY AND ECONOMIC RESOURCES (RER)
CODE ADMBU3T11ATION DIvl,4ION
Hug products Corporation
e Street
OH 43812
N14M-=DA.DE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Sft=% Room 208
Masai, Florida 33175-2474
T (786) 315-2590 F (786)'315-2599
wwwidamidade gLIs oaomy
SCANNED
BY
St Lucie County
yr.
NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
mentation.submitted has been reviewed.and accepted by Miami Dade County RER - Product Control Section to be
in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control Section
rIianni Dade County) andlor the AHJ (in areas other than Miami Dade County) reserve the right to have.this
fact or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
ner, the manufacturer will incur the expense of such testing and the AAJ may immediately revoke, modify, or
er, , use of such product or material within their jurisdiction. RBR reserves the right to revoke this acceptance,
is determined by Miami Dade County'Product Control Section that this product or material fails to meet the
iirements of the applicable building code.
product is approved as described herein, and has been designed to comply with the Florida Building Code
uding the Hugh Velocity Hurricane Zone of the Florida Building Code.
SCRIPTmom Ultra HT Wind & Water Seal I" High Temperature .
SEEING: Each unit shall bear a pemoanent label with the manufacturer's name or logo, city, state.and following
anent: ''Miami -Dade County Product Control Approved", unless otherwise noted herein.
NEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
�e applicable building code negatively affecting the performance of this product.
DAMN of this. NOA will occuir after the expiration date or if there has been a revision or change induct,
erials, use, andlor manufacture of the productorprocess. Misuse of this NOA as an endorsement of any pr
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
his. NOA shall be cause for termination and removal. of NOPL
A.DVERTISEMEN'T: The NOA number preceded by the words Miami Dade County, Fronde, and followed by the
expiration.date may be -displayed in adveitlsmg literature. If any portion of the NOA is, displayed, then it shall be done
in its entirety.
=beCTION: A copy of this entire NOA shall :be provided to the user by the manufacturer or its distributors .and available for inspection at the job site at the request of the Building Official.
NOA.consists of pages 1 through 3.
submitted documentation was reviewed by Juan E. C61100, PA-
NOA, No.: 13-11MA6
Expiration Date: 03/27/19
Approval Date: 03/27/14
Page I of 3
l
ROOFING COMPONENT APPROVAL
Cates_
Sub -Category
Roofing
Underlayment
SBS
it
SCOPE:
This acceptance is for Ultra HT Wind and Water Seal` High Temperature roof underlayment as described in ithis
Notice of Acceptance, for use with approved prepared roof assemblies.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specation Description i'
Ultra HT Wind and Water 36' x 67' rolls ASTM D 1970 45 mils thick (nominally), self adhering,
Seal•` High Temperature membrane composed of a white, non -slip crop �s-
lan inated polymer film, laminated to a I
rubberized asphalt adhesive with a split release
liner.
MANUFACTURING LOCATION:
1. Coshocton, OH
EVIDENCE SUBMITTED:
Test Agency Vest Idenfter Test Name/Renort Date
PRI Construction Materials Technologies,, MFM-039-02-01 ASTM D 1970 08/15L13
Inc.
APPROVED ASSEMBLIES:
Deck Type 1: Wood, non insulated
Deck Description: New construction or reroof minimum 19&, or greater plywood or wood plank.
System E(1): Anchor sheet mechanically fastened deck, membrane adhered.
Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" head rap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" -d.c. at the laps and
two staggered rows 12" o.c. the field of the roll.
Membrane: One or more plies of Ultra HT Wind & Water Seal` High Temperature underlayment with a
minimum.3" side lap and 6' end lap. Place the first course of membrane parallel to the eaves
rolling the membrane to obtain maximum contact. Remove the release membrane as the.
membrane is applied.
Surfacing: Approved for mechanically fastened metal roofing, asphaltic shingles, wood shakes and shingles,
quarry slate roof assemblies. 1'
NOA No.: 13-1125.06
MWMtd)�ADE cou E*ratlon-Date: 03/27/19
Approval -Date: 03i27n4
Page 2 of 3
r
1. Fire Classification is not part of this' acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. Ultra HT Wind & Water Seal°! High Temperature underlayment shall be installed, in
strict compliance with applicable Building Code.
3. Ultra HT Wind & Water SeaI7 High Temperature underlayment may be used in mechanically fastened metal
roofing, asphaltic shingles, wood shakes and shingles, quarry slate roof assemblies. Ultra HT. Wind & Water
Seal"` High Temperature underlayment shall not be used as roof tile underlayment.
4. Ultra HT Wind & Water Seal' High Temperature underayment shall be applied to a smooth, clean, and dry
surface with deck free of irregularities.
5. Ultra HT Wind & Water Seal High Temperatureunderlayment shall not be applied over an existing roof
membrane as a recover system.
6. Ultra HT'Wind & Water Seal` High Temperature underlayment shall not be left exposed as a temporary roof for
longer than 30 days of application.
7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. '
& Ultra.HT Wind & Water Seal` High Temperature underlayment may be used with any approved roof covering
Notice of Acceptance listing Ultra HT Wind & Water Seaiw High Temperature underlayment as, a component
part of an assembly in the Notice of Acceptance. If it is not listed, a request may be made to the Authority
Having Jurisdiction (AHJ) or the. Miami -Dade County Product Control Department for approval provided that
appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire.
testing results.
9. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions. For ridge applications, center the membrane and roll from
the center outward in both directions.
10. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention
to overlap areas.
11. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
12. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed,in place and formed around the protrusions to ensure a tight fit. A second layer of Ultra HT Wind &
Water Seal` High Temperature underlayment shall be applied over the underlayment.
13. All products listed herein shall have a quality assurance audit in accordance with the'Florida Bu ilding:Code and
Rule 61G20-3 of the Florida Administrative Code.
14, All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,
city and.state of manufacturing facility, and the following statement: "Miami -Dade County Product Control
Approved" or the Miami Dade County Product Control Seal as shown below.
MlAMI•DJ1DE COUKfY
APPROVED
END OF THIS ACCEPTANCE
NOA No.: 13-1125.06
Expiration Date: 03/27/19
Approval Date: 03/27114
Page 3 of 3