Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL - MODIFIED BITUMEN1 Q/8/2018 ,_ Florida Building Code Online Fiodda r� & ,0a t!g cof d�M BCIS Home I Log In ! User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category FL2533-R20 Revision 2017 Approved N SCANNED BY St Lucie County CertainTeed Corporation -Roofing 20 Moores Road Malvern, PA 19355 (610) 893-5400 mark.d.harner@saint-gobain.com Mark Harrier mark.d.harner@saint-gobain.com Mark D. Harrier 18 Moores Road Malvern, PA 19355 (610) 651-5847 Mark.D.Harner@saint-gobain.com Roofing https:ltfloridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgvwelwRFXRvHOHSbalV%2f8Ets3rRVh8k3uB2Sy%2b%2gMVggA%3d%3d ST. LUCIE BUILDING FOR REVIEWED BY DATE to I2C— 1 F AN5 AND PER IT MUST BE KEPT ON OB OR NO INSPECTION WIL BE MADE THESE PLANS AND ALL PROPOSED WORK. . ARE SU ECT TO ANY CORREC T ONS ,. (REQUIRED BY FIELD INSPECTORS THAT MAY DE NECESSARY IN ORDER M � COMPLY WITH ALL APPLICAKE CODES. CONCEALED FASTENERS OR -ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD P t _ E %40PY . -a 113 1 0/8/201 8 „ Florida Building Code Online Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer E' Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Robert Nieminen PE-59166 UL LLC 03/09/2020 John W. Knezevich, PE W) Validation Checklist - Hardcopy Received FL2533 R20 COI 2018 01 COI NIEMINEN.pdf Standard Year ASTM D6162 2008 ASTM D6163 2008 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2009 FM 4470 2012 FM 4474 2011 Method 1 Option D 06/20/2018 06/20/2018 06/27/2018 https://floridabuilding.org/pr/pr app_dtl.aspx7param=wGEVXQwtDgvwelwRFXRvHOHSbaIV%2f8Ets3rRVh8k3uB2Sy%2b%2fMVggA%3d%3d 2/3 10/8/2018 . Florida Building. Code Online Date Approved 08/15/2018 Summary of Products FL # Model, Number or Name Description 2533.1 Flintlastic Modified Bitumen Roof Modified Bitumen Roof Systems Systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL2533 R20 II 2018 06 FINAL Al ER CERTAINTEED MODBIT FL2533- Approved for use outside HVHZ: Yes R20.pdf Impact Resistant: N/A Verified By: Robert Nieminen, PE PE-59166 Design Pressure: +N/A/-635 Created by Independent Third Party: Yes Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) Evaluation Reports The design pressure noted in this application relates to FL2533 R20 AE 2018 06 FINAL ER CERTAINTEED MODBIT FL2533- one specific system. Refer to the ER Appendix for all R20.pdf systems and max design pressures. Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® 99 Im Credit s� eurit�=n�t_7•xte5- https://floridabuilding.org/pr/pr app_ fl.aspx?param=wGEVXQwtDgvwelwRFXRvHOHSbalV%2f8Ets3rRVh8k3uB2Sy%2b%2fjjMVggA%3d%3d 3/3 nt4 - -NEMO TABLE` DECK:' ::., APPLICATION, . '.:: ":TYPE 'DESCRIPTION ." PAGE; 1A Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-6 18 Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 7 1C Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 8-9 1D Wood New, Reroof (Tear -Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 10-12 1E-1 Wood New, Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 13-15 1E-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 16-17 1F Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 17 2A Steel or Structural Concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 18-20 28 Steel or Structural Concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 2141? 2C Steel or Structural Concrete New, Reroof (Tear -Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 26-;L_ - 3A Concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 29-36 3B Concrete New or Reroof (Tear -Off) A-3 Bonded Temp Roof/Vapor Barrier, Bonded Insulation, Bonded Roof Cover 36 3C Concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 37 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 38-39 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 40 4C LWIC New, Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 41-44 5A CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 45 58 CWF New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 46 Sc CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 46 SD CWF New, Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 47 6A Gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 48-49 6B Gypsum Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 50 6C Gypsum Reroof (Tear -Off) C Mech. Attached Insulation, Bonded Roof Cover 51- 6D Gypsum Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 51 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 52-57 713 Various Recover F Non -Insulated, Bonded Roof Cover 57 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: OMG #14 Roofgrip with Flat Bottom Plate (Accutrac), OMG HD with OMG 3 in. Galvalume Steel Plate, Dekfast #14 with Hex Plate or 3" Round Insulation Plate, Trufast HD with Trufast 3" Metal Insulation Plates or FlintFast #14 Fastener with FlintFast 3" Insulation Plates. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. ➢ Steel Deck: OMG #12 or #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG #12 Standard or HD with OMG 3 in. Galvalume Steel Plate, Dekfast #12 or #14 with Hex Plate or 3" Round Insulation Plate, Trufast DP or HD with Trufast 3" Metal Insulation Plates or FlintFast #12 or #14 Fastener with FlintFast 3" Insulation Plates. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. ➢ Structural Concrete: OMG #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG HD or CD-10 with OMG 3 in. Galvalume Steel Plate, Dekfast #14 or DekSpike with Hex Plate or 3" Round Insulation Plate, Trufast HD or CF with Trufast 3" Metal Insulation Plates or FlintFast #14 Fastener with FlintFast 3" Insulation Plates. Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation instructions. NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-1120 Certificate of Authorization #32455 CH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5B47 Appendix 1, Page 1 of 57 1 ONEM01jetc. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocya nu rate, polystyrene, wood fiberboard, perlite, GlasRoc Roof Board or gypsum -based roof board that meets the QA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for, or installed beneath rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet screws and plates are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. S. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016). 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Hot asphalt (HA): Full coverage at 25-30 Ibs/square ➢ Ashland Pliodeck (A-PD): Continuous 0.75 inch wide ribbons,12-inch o.c. Ribbons of subsequent layers shall be perpendicular to those in the layer below. ➢ Dow INSTA-STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1 inch wide ribbons,12-inch o.c. ➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ➢ Millennium PG-1 Pump Grade Adhesive (M-PG3): Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c. ➢ OMG OlyBond 500 or OlyBond Green (OB500): Continuous 0.75-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot) ➢ ICP Adhesives CR-20: Continuous 2.5 to 3-inch wide ribbons, 12-inch o.c. ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, boards shall be staggered from layer -to -layer. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyan u rate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: ➢ Ashland Pliodeck (A-PD) @ 12-inch o.c. MDP -105.0 psf (Min.1.0-inch) ➢ Ashland Pliodeck (A-PD) @ 6-inch o.c. MDP -277.5 psf (Min. 1.0-inch) ➢ Dow INSTA-STIK Quik Set Insulation Adhesive (D-IS): MDP -120.0 psf (Min.1.0-inch) ➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min.1.0-inch) ➢ Millennium PG-1 Pump Grade Adhesive (M-PG3): MDP -157.5 psf (Min.1.0-inch) ➢ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch Multi -Max FA3) ➢ OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-inch ISO 95+GL) ➢ OMG OlyBond 500 (08500): MDP -315.0 psf (Min. 0.5-inch ENRGY 3) ➢ OMG OlyBond 500 (OB50O): MDP -487.5 psf (Min. 0.5-inch ACFoam II) ➢ ICP Adhesives CR-20: MDP -117.5 psf (Min.1.0-inch) B. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria, Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 10. For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. NEMO ETC, LLC Evaluation Report 3520.03.04-1121 for FL2533-R20 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 6S3-SB47 Appendix 1, Page 2 of 57 OMEMO I etc. 12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Concrete Deck or Recover Applications using System Type D, the insulation is optional. 14. Lightweight Insulating Concrete (LWC) shall be cast, in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction.. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific deck. construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1 15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. CERTAINTEED FLINTLASTIC" MODIFIED BITUMEN COMPONENTS & APPLICATION METHODS REFERENCE MATERIAL APPLICATION•• BP -AA Base Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20 Hot asphalt at 20-40 Ibs/square Ply One or more Flintglas PIy.4; Flintglas Premium Ply 6 (Base and Ply sheets, Asphalt -Applied) BP-AA2 Base Yosemite Venting Base Hot asphalt in 24-inch diameter spots in 30- (Base, Spot -Asphalt -Applied) inch grid pattern BP-AA3 Base Yosemite Venting Base Hot asphalt in 9-inch diameter spots in grid (Base, Spot -Asphalt -Applied) pattern noted herein. BP-AA4 Base Yosemite Venting Base Hot asphalt in 9-inch wide ribbons spaced (Base, Strip -Asphalt -Applied) as noted herein. BP-CA2 Base/Ply Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20 Henry #903 Adhesive at 1.5 gal/square BP CA3 Base/Ply Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic ease 20 Millennium Hurricane Force Membrane Adhesive, beads spaced 6-inch o.c. Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base SBS AA Ply One or more Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Cap Flintlastic Cap 30; Flintlastic Cap 30 CoolStar, Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual (SBS, Asphalt -Applied) Hot asphalt at 20-40 Ibs/square Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStar Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Note: Base ply cures overnight prior to application of the ply or cap ply. Flint.8ond Brush or Karnak No. 81 Cold SBS-CAI ISM, Cold -Applied) Process Modified Bitumen Adhesive Brush \ Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Cap Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar, Grade at 1 gal/square Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStar Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base SBS-CA2 Cap Flintlastic Cap 30; Flintlastic Cap 30 CoolStar, Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual (SBS, Cold -Applied) Henry #903 Adhesive at 1.5 gal/square. Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar, Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStar NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20 Certificate of Authorization #32455 6"' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-SB47 Appendix 1, Page 3 of 57 ONEMO I etc. CERTAINTEED FLINTLASTIC" MODIFIED B... . .. (CONTINUED) °<REFERENCE '..: LAYER:' _ MATERIAL. APPWCATION Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base SBS-CA3 (SBS, Cold -Applied) Millennium Hurricane Force Membrane Adhesive, beads spaced 6-inch o.c. Cap Flintlastic Cap 30; .Flintlastic Cap 30 CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStar Base Flintlastic Ultra Poly SMS Base; Flintlastic Base 20 T Ply One or more Flintlastic Ultra Poly SMS Base; Flintlastic Base 20 T SBS-TA (SBS, Torch -Applied) Torch -Applied r Cap Flintlastic FR Cap 30 T; Flintlastic FR Cap 30 T CoolStar; Flintlastic GTS; Flintlastic GTS CoolStar; Flintlastic GTS-FR; Flintlastic GTS-FR CoolStar; FlintClad APP-TA (APP, Torch -Applied) Base One or more Flintlastic APP Base T; Flintlastic STA; Flintlastic STA Plus Torch -Applied pP Cap Flintlastic STA; Flintlastic STA Plus; Flintlastic GTA; Flintlastic GTA CoolStar; Flintlastic GTA-FR; Flintlastic GTA-FR CoolStar SBS-SA-H (SBS, Self -Adhering, Hybrid Systems) Base/Ply Black Diamond Base Sheet; Flintlastic Ultra Glass SA Self -Adhering Base Flintlastic SA PlyBase; Flintlastic SA Mid Ply SBS-SA (585, Self -Adhering) Self -Adhering Ply Flintlastic SA PlyBase; Flintlastic SA Mid Ply Cap Flintlastic SA Cap; Flintlastic SA Cap CoolStar, Flintlastic SA Cap FR; Flintlastic SA Cap FR CoolStar 16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following MDP limitations. The lesser of the MDP listings below vs. those in Table 3A applies: OPTION # VAPOR .. PRIMER BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; ADHERED INSULATION PERTABLE 3A; (The lesser of the MDP listings below VS. those VAPOR BARRIER in Table 3A applies) INSULATION ADHESIVE MDP (PSIS ;: TYPE ATTACK.:- - VB-1. FlintPrime Flintlastic SA PlyBase Self -adhering OB500,127inch o.c. -82.5 VB-2. FlintPrime Flintlastic GTA Torch -applied M-OSFA or M-PG1,12-inch o.c. -420.0 VB-3. FlintPrime Flintlastic Base 20 T, Flintlastic FR Cap 30 T or Flintlastic GTS Torch -applied M-OSFA or M-PG1,12-inch o.c. -495.6' 17. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. NEMO ETC, LLC Certificate of Authorization #32455 Prepared by: Robert Nieminen, PE-59166 eEDITION (2017) FBC NON-HVHZ EVALUATION CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Evaluation Report 3520.03.04-R21 for FL2533-R20 Revision 21: 06/20/2018 Appendix 1, Page 4 of 57 ONEMO I etc. TABLE 1E-2: WOOD DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE E. NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System , .: Deck. Base Sheet RoofCover.(Note 14) 1VIDP No. (Noted) ::(Psfl :. Base: Fasteners Attach' Ply: Cap; Glasbase; Flexiglas; Flintlastic Flintfast 3 in. Insulation Plates with (Optional) BP - W-89 Min. 15/32-inch plywood Base 20; Poly SMS Base; Ultra FlintFast #12 or #14; Trufast 3" Metal 6-inch o.c. at 4-inch lap and 6-inch o.c, in three AA, SBS-AA, SBS-AA, SBS- _97,5 at max 24-inch spans P Poly SMS Base; Yosemite Insulation Plates with DP or HD; OMG 3 (3), equally spaced, staggered center rows SBS-TA or TA or APP-TA in. Round Metal Plates with OMG #14 HD APP-TA W 90 Min. 15/32-inch plywood Flintlastic APP Base T OMG 3 in. Round Metal Plates with OMG 6-inch o.c. at 4-inch lap and 6-inch o.c. in three APP-TA APP-TA -97.5 at max 24-inch spans #14 HD (3), equally spaced, staggered center rows. Glasbase; Flexiglas; Flintlastic W-91 Min. 15/32-inch 1 plywood Base 20; All Weather / Empire Flintfast 3 in. Insulation Plates with 8-inch o.c. at 4-inch lap and 8-inch o.c. at three (Optional) BP- SBS-AA or at max 24-inch spans P Base; Poi SMS Base; Ultra PolyFlintFast y Trufast 3" Metal Insulation (3) equally spaced, staggered center rows AA, SBS AA or SBS-TA -97.5 SMS Base; Yosemite Plates with Trufast HD w th T SBS-TA W-92 Min. 19/32-inch plywood Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Note 2 7-inch o.c. at 3-inch lap and 7-inch o.c. in three BP -AA, SBS- AA SBS-TA or SBS-AA, SBS- -105.0 at max 24-inch spans Poly SMS Base; Yosemite (3), equally spaced, staggered center rows APP-TA TA or APP-TA W 93 Min.19/32-inch plywood Flintlastic APP Base T OMG 3 in. Round Metal Plates,with OMG #14 HD or Dekfast Hex Plate with Dekfast 7-inch o.c. at 3-inch lap and 7-inch o.c. in three APP-TA APP-TA -105.0 at max 24-inch spans P #14 (3), equally spaced, staggered center rows Glasbase; Flexiglas; Flintlastic Flintfast 3 in. Insulation Plates with (Optional) BP- W-94 Min. 15/32-inch plywood Base Poly SMS Base; Ultra FlintFast #12 or #14; Trufast 3" Metal 6-inch o.c. at 4-inch lap and 6-inch o.c, in four AA, SBS-AA, SBS-AA, SBS- -127.5 P at max 24-inch spans Poly SMS Base; Yosemite M Insulation Plates with DP or HD; OMG 3 (4), equally spaced, staggered center rows SBS-TA or TA or APP-TA in. Round Metal Plates with OMG #14 HD APP-TA W-95 Min. 15/32-inch plywood Flintlastic APP Base T OMG 3 in. Round Metal Plates with OMG 6-inch o.c. at 4-inch lap and 6-inch o.c. in four APP-TA APP-TA -127.5 at max 24-inch spans #14 HD (4). equally spaced, staggered center rows. Glasbase; Flexiglas Base; W-96 Min.15/32-inch plywood Flintlastic Base 20; All Weather / Flintfast 3 in. Insulation Plates with 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (Optional) at max 24-inch spans P Empire Base; Yosemite Venting FlintFast #12 or #14; Trufast 3" Metal (3), equally spaced, staggered center rows SBS-CAl SBS-CA3 52.5 Base; Flintlastic Poly SMS Base; Insulation Plates with DP or HD Flintlastic Ultra Poly SMS Base . .-System . Deck' Roof CoVer;(Note;14) No.. (Note 1) Pri Base. Ply cap. mer MDP (Psf) . W-97 Min. 15/32-inch plywood at max 24-inch spans FlintPrime or FlintPrime SA SBS-SA-H (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -112.5 W-98 Min. 1S/32-inch plywood at max 24-inch spans FlintPrime or FlintPrime SA SBS-SA (Optional) SBS-SA SBS-SA -127.5 NEMO ETC, LLC Evaluation Report 3520.03.04-1121 for FL2533-1120 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21:- 06/20/2018 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-S847 Appendix 1, Page 17 of 57 1 J I