HomeMy WebLinkAboutENERGY EFFICIENCY CODEFTLFORM R405-2017
FLU ENERGY EFFICIENCY CODE FOR BUILD C p
y
ION
Florida Department of Business and Professional Regulation - Residential Performance Method
i
i
Project Name. Gambina Guest House
Builder Name:
treet S)
Permit Office:
SCANNED
City, State, Zip: Port St. Lucie, FL , 34986
Permit Number.
S
� Y
Owner , Gambina Guest House
Jurisdiction:
t LUG
Designi Location: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 J County
J
1. construction
New or existing New (From Plans)
9. Wall Types (1770.0 sqft.)
Insulation Area
2. Singlc family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1770.00 ftz
3. Number of units, if multiple family 1
b. NIA
R= ftz
c. NIA
R= ftz
4. Number of Bedrooms 1
d. N/A
R= ftz
5. Is this a worst case? No
10. Ceiling Types (1335.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 1335.00 ftz
6. Condii ioned floor area above grade (ftz) 1335
b. N/A
R= ftz
Conditioned floor area below grade (ftz) 0
c. N/A
R= ft z
11. Ducts
R ftz
7. Wind6ws(140.8 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 140
a. U-Factor: Dbl, U=0.65 124.80 ftz
SHGC: SHGC=0.25
b. U-Factor:" Dbl, U=0.65 16.00 ftz
12. Cooling systems
kBtulhr Efficiency
SHGC: SHGC=0.30
a. Central Unit
24.0 SEER:16.00
c. U-Factor: N/A ftz
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftz
a. Electric Strip Heat
17.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.224 ft.
Area Weighted Average SHGC: 0.256
14. Hot water systems
8. Floor Types (1335.0 sgft.) Insulation Area
a. Electric
Cap: 50 gallons
a. SlatI-On-Grade Edge Insulation R=0.0 1335.00 ftz
b. Conservation features
EF: 0.950
b. NIA R= ftz
None
c. NIA R= ftz
15. Credits
CF, Pstat
Total Proposed Modified Loads: 46.95
Glass/Floor Area: 0.105
PASS
Total Baseline Loads: 51.37
l
I hereby certify that the plans and specifications covered by
Review of the plans and
Srtq ,
this calculation.are in compliance with the Florida Energy
specifications covered by this
04111E
= O�
Code.
calculation indicates compliance
_py
with the Florida Energy Code.
PREPAR D
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
I hereby
perlify that this building, as designed, is in compliance
Florida Statutes.
with the
Florida Energy ode.
G'Ob
OWNER/AGENT:
�r^_'��
BUILDING -OFFICIAL:
0+ 4
DATE:
DATE:
i
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
8/13/2018 5:17 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
INPUT SUMMARY (.I-IFrKI IRT RFPn1 T
PROJECT
Title:
Gambina Guest House
Bedrooms: 1
Address Type:
Street Address
Building
Type: User
Conditioned Area: 1335
Lot #
Owner
Name: Gambina Guest House
Total Stories: 1
Block/Subdivision:
# of Ulits:
1
Worst Case: No
PlatBook:
Builder)
Name:
Rotate Angle: 0
Street:
PennitlOffice:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
Port St. Lucie ,
Family
Type: Single-family
FL, 34986
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V
Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number
Name
Area Volume
1
Entire House
1335 14852
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
Infil, ID Finished Cooled
Heated
1
Bathroom
147 1470 No
0
11 Yes
Yes
Yes
2
Laundry
42 420 No
0
1 Yes
Yes
Yes
3
Closet
70 700 No
0
1, Yes
Yes
Yes
4
Bath
28 280 No
0
1 No
Yes
Yes
5
Kitchen
153 1530 Yes
0
1 Yes
Yes
Yes
6
Cafe
144 1440 No
0
1 Yes
Yes
Yes
7
Living Room
369 4428 No
2
1 Yes
Yes
Yes
8
Bedroom
382 4584 No
2
1
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist RWalue
Tile Wood
Carpel
1 Slab -On -Grade Edge Insulatio
Bathroom 241t 0
147 ft2
1 0
0
i
2 Stab-9n-Grade Edge Insulatio
Laundry 6 ft 0
42 ft2
0
0
3 Slab -On -Grade Edge Insulatio
Closet 7 ft 0
70 112
___
1 0
0
4 Slab -On -Grade Edge Insulatio
Bath 1 It 0
28 ft2
0
0
5 Slab -On -Grade Edge Insulatio,
Kitchen 12 ft 0
153 ft'
0
0
6 Slab -On -Grade Edge Insulatio
Cafe 26 ft 0
144 ft2
0
0
7 Slab -On -Grade Edge Insulatio
i
Living Room 38 ft 0
369 ft2
1 0
0
8 Slab -On -Grade Edge Insulatio
Bedroom 47 it 0
382 ft'
1 0
0
8/13/20118 5:17 PM EnergyGaugeO USA Section'R405.4.1 Compliant Software
I
Page 2 of 5
i
FORM R405-2017 INPUT SUMMARY CH17MI IST REPORT
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
1/
#
Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1
Hip Barrel tile 1493 W
0 ft2
Dark
0.6
No
0.9
No
20
26.6
ATTIC
v
#
Type - Ventilation
Vent Ratio (1
in) Area
RBS
IRCC
1
Full attic Unvented
0
1335 ft2
N
Y
CEILING
#
Ceiling Type Space
R-Value
Ins Type'
Area
Framing Frac Truss Type
1
Under Attic (Unvented) Bathroom
20
Blown
147 ft2
0.1
Wood
2
Under Attic (Unvented) Laundry
20
Blown
42 ft2
0.1
Wood
3
Under Attic (Unvented) Closet
20
Blown
70 ft2
0.1
Woad
4
Under Attic (Unvented) Bath
20
Blown
28 ft2
0.1
Wood
5
Under Attic (Unvented) Kitchen
20
Blown
153 ft2
0.1
Wood
6
Under Attic (Unvented) Cafe
20
Blown
144 ft2
0.1
Wood
7
Under Attic (Unvented) Living Room
20
Blown
369 ft2
0.1
Wood
8
Under Attic (Unvented) Bedroom
20
Blown
382 ft2
0.1
Wood
WALLS
Adjacent
Space
Cavity Width Height
_
Sheathing Framing
Solar
Below
o
_ 1
N
Exterior Concrete Block - Ext InsuBathroom
4.1 13
0 10
0
130.0 ft2
0
0
0.6
0
2
E
Exterior Concrete Block - Ext InsuBathroom
4.1 11
0 10
0
110.0 ft2
0
0
0.6
0
3
N
Exterior Concrete Block - Ext Insul Laundry
4.1 6
0 10
0
60.0 ft2
0
0
0:6
0
4
E
Exterior Concrete Block - Ext Insul ' Closet
4.1 7
0 10
0
70.0 ft2
0
0
0.6
0
5
N
Exterior Concrete Block - Ext Insul Kitchen
4.1 12
0 10
0
120.0 ft2
0
0
0.6
0
6
N
Exterior ConcreWBlock - Ext Insul Cafe
4.1 8
0 10
0
80.0 f12
0
0
0.6
0
7
S
Exterior Concrete Block - Ext Insul Cafe
4.1 1
0 10
0
10.0 ftz
0
0
0.6
0
_ 8
SW
Exterior Cohcrete Block,- Ext Insul Cafe
4.1 5
0 10
0
50.0 ft2
0
0
0.6
0
_ 9
W
Exterior Concrete Block - Ext Insul Cafe
4.1 7
0 10
0
70.0 fie
0
0
0.6
0
10
I NW
Exterior Concrete Block - Ext Insul Cafe -
4.1 5
0 10
0
50.0 ft2
0
0
0.6
0
11
S
Exterior Concrete Block - Ext Insl iving Room
4.1 20
0 12
0
240.0 ft2
0
0
0.6
0
12
W
Exterior Concrete Block - Ext InsLdving Room.
4.1 18
0 12
0
216.0 ft2
0
0
0.6
0
13
E
Exterior Concrete Block - Ext InsuBedroom
4.1 21
0 12
0
252.0 ft2
0
0
0.6
0
14
S
Exterior Concrete Block - Ext InsuBedroom
4.1 18
0 12
0
216.0 ft2
0
0
0.6
0
15 1 W
Exterior Concrete Block - Ext InsuBedroom
4.1 8
0 12
0
96.0 ft2
0
0
0.6
0
DOORS
#
Ornt Door Type Space
Storms
U-Value Width
Height
Area
Ft
In
Ft, In
1
W Wood Living Room
None
.39
3
8
24 f12
2
S Wood Bedroom
None
-.39
2
10
8
22.7 ft2
8/13120 8 5:17 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Pro osed orientation.
J
Wall
Overhang
#
Ornt ID Frame
Panes NFRC
U-Factor .SHGC Imp,
Area
Depth
Separation
Int Shade
Screening
1
N 1 Metal
Low-E Double Yes
0.65 0.25 N
8.0 ft2
1 ft 7 in
1 ft4 in
None
None
2
E 2 Metal
Low;E Double Yes
0.65 0.25 N
&0 ft?
1 ft 7 in
1 ft4 in
None
None
3
SW 8 Metal
Low-E Double Yes
0.65 0.3 N
3.0 ft2
1 ft 7 in
1 ft 4 in
None
None
4
SW 8 Metal
Low-E Double Yes
0.65 0.25 N
12.0 ft2
1 ft 7 in
1 ft 4 in
None
None
5
W 9 Metal
Low-,E Double Yes
0.65 0.3 N
3.0 ft2
1 ft 7 in
1 ft 4 in
None
None
I
6
W 9 Metal
Low-E Double Yes
0.65 0.25 N
12.0 ft2
1 ft7 in
1 ft 4 in
None
None
7
i
NW 10 Metal
Low-E Double Yes
0.66 0.3 N
3.0 ft2
1 ft 7 in
1 ft 4 in
None
None
8
NW 10 Metal
Low-E Double Yes
0.65 0.25 N
12.d ft2
1 ft 7 in
1 ft 4 in
None
None
9
W 12 Metal
Low-E Double Yes
0:65 0.3 N
3.0 ft2
6 ft 0 in
1 ft 4 in
None
None
10
W 12 Metal
Low-E Double Yes
0.65 0.25 N
24.8 ft2
1 ft 7 in
1 ft4 in
None
None
11
W 12 Metal
Low-E Double Yes
0.65 0:3 N
4.042
1 ft 7 in
1 ft 4 in
.None
None
12
E 13 Metal
Low-E Double Yes
0.65 0.25 N
36.0 ft2
1 it 7 in
1 ft "4 in
None
None
13
W 15 . Metal
Low-E Double Yes
0.65 0.26 N
12.0 ft2
8 ft 0 in
1 ft 4 in
None
None
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Whilehouse
Proposed ACH(50) .000495
1732.7 95.12 178.9
.3958
7
HEATING SYSTEM
#
,System Type
Subtype-
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat None
COP:1
17 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
SEER: 16
24 kBtu/hr
cfm
0.7 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType Location
EF Cap
Use
SetPnt
Conservation
1
Electric
None Laundry
0.95 50 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert .# Company Name
System Model # Collector Model #
Area
Volume
FEF
None
None
ft2
EnergyGougeO.USA Section R405.4.1 Compliant Software
Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DUCTS
—
Supply --
-- Return —
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area
. Leakage
Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic
6 140 ft2
Attic
45 ft2
DefaultLeakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling [ j Jan ((j
Feb
Feb
j j Mar
MarAppr
[
] Apr
j
[
j May
] May
[Xj Jun
i Jun
jXj Jul
[ ] Jul
ri Aug
AugjXj
Sep
SeppOct
W Oct j
X
j Nov
Nov
j( Dec
XDec
VentinggJanl
Ventin [ ]Jan [
i
J Feb
[XJ Mar
[X]
A r
[
J Ma
[ ]Jun
t
[ j Jul
Aug
Se
Oct l[xXJJ
Nov
[ Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80`
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78,
78
78
78
78
78
PM
7.8
78
78
78
78
78
78
78
78
� 78
78
78
HeatingD)
AM
66.
66
66
66
66
68
68
68
68
68
68
68
7
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
1
PM
68 _
68
68
68
68
68
68
68
68
68
66
66
MASS
ryass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 It
0.3
Bathroom
Default(81bs/sq.ft.
ft2
ft
0.3
Laundry
Defaulqu lbs/sq.ft.
ft2
ft
0.3
Closet .
Default(8 Ibs/sq.ft.
ft2
it
0.3
Bath
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Kitchen
De1au1t(8 Ibs/sq.ft.
ft2
ft
0.3
Cafe
Defaunto Ibs/sq.ft.
ft2
ft
0.3
Living Room
Default(8 Ibs/s .ft.
ft2
ft
0.3
Bedroom
Name:
Rating Compant:
i
8/13/2018 5:17 PM
.���fllt `♦1
q
e. l I
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Gambina Guest House Builder Name:
Sir eet: Permit Office:
City, State, Zip: Port St. Lucie , FL , 34986 Permit Number:
Owner: Gambina Guest House Jurisdiction:
w
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
Geneial
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
i
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
the insulation andahy gaps in the air barrier shall be sealed.
The Insulation in any dropped ceiling/soffit
Access openings, drop down stairs or knee wall doors to
shall be aligned with the air barrier.
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air bamer.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -',garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)'
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
I
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recesi ed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring-
Showeldtub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers prs
sealed in a manner that is recommended by the manufacturer.
I
Caulking or other adhesive sealants shall not be used to fill voids
a_ In addition inen rtin
of In �n� �ti.,u �..,
-- •••--�••••.. , •.+'.....•..•• .• ,vy —1— be 1,, --dal ce WI111 41C IJIUVISI0115 UI 1k L--4UU.
8/14/2018 10:56 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
201iF EPL DISPLAY CARD
I
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
4. Number of bedrooms
9. Is this a worst case? (yes/no)
6,. Conditioned floor area (sq. ft.)
I
71. Windows, type and area
a) U-factor:(weighted average)
I
b) Solar Heat Gain Coefficient (SHGC)
c) Area
8. Skylights
a) U-factor:(weighted average)
b) Solar Heat Gain Coefficient (SHGC)
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
I A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
3.
1
4.
1
13. Cooling system: Capacity
24.0
a) Split system SEER
16.0
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6.
1335
d) Room unit/PTAC EER
e) Other
7a.
0.650
7b,
0,256
14. Heating system: Capacity
17.0
7c.
140.7
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP
1.0
8a.
NA
d) Gas furnace, natural gas AFUE
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9a.
0.0
9b.
15. Water heating system
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
10A1.
e) Dedicated heat pump with tank EF
10A2.
4.1
f) Heat recovery unit HeatRec%
g) Other
1081.
10132.
16. HVAC credits claimed (Performance Method)
111. Ceiling type and insulation level a) Ceiling fans Yes
a) Under attic 11 a. 20.0 b) Cross ventilation No
b) Single assembly 11b. c) Whole house fan No
c) Knee walls/skylight walls 11c. d) Multizone cooling credit
d) Radiant barrier installed 11d. No e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: 6' Date:
i
Address of New Home: Z4 nUlA C/ e- City/FL Zip: Port St. Lucie, FL 34986
8/14/2018 10:55:54 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1