HomeMy WebLinkAboutENERGY EFFICIENCY CODEFTLFORM R405-2017 FLU ENERGY EFFICIENCY CODE FOR BUILD C p y ION Florida Department of Business and Professional Regulation - Residential Performance Method i i Project Name. Gambina Guest House Builder Name: treet S) Permit Office: SCANNED City, State, Zip: Port St. Lucie, FL , 34986 Permit Number. S � Y Owner , Gambina Guest House Jurisdiction: t LUG Designi Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 J County J 1. construction New or existing New (From Plans) 9. Wall Types (1770.0 sqft.) Insulation Area 2. Singlc family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1770.00 ftz 3. Number of units, if multiple family 1 b. NIA R= ftz c. NIA R= ftz 4. Number of Bedrooms 1 d. N/A R= ftz 5. Is this a worst case? No 10. Ceiling Types (1335.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 1335.00 ftz 6. Condii ioned floor area above grade (ftz) 1335 b. N/A R= ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ft z 11. Ducts R ftz 7. Wind6ws(140.8 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 140 a. U-Factor: Dbl, U=0.65 124.80 ftz SHGC: SHGC=0.25 b. U-Factor:" Dbl, U=0.65 16.00 ftz 12. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.30 a. Central Unit 24.0 SEER:16.00 c. U-Factor: N/A ftz SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.224 ft. Area Weighted Average SHGC: 0.256 14. Hot water systems 8. Floor Types (1335.0 sgft.) Insulation Area a. Electric Cap: 50 gallons a. SlatI-On-Grade Edge Insulation R=0.0 1335.00 ftz b. Conservation features EF: 0.950 b. NIA R= ftz None c. NIA R= ftz 15. Credits CF, Pstat Total Proposed Modified Loads: 46.95 Glass/Floor Area: 0.105 PASS Total Baseline Loads: 51.37 l I hereby certify that the plans and specifications covered by Review of the plans and Srtq , this calculation.are in compliance with the Florida Energy specifications covered by this 04111E = O� Code. calculation indicates compliance _py with the Florida Energy Code. PREPAR D Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby perlify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy ode. G'Ob OWNER/AGENT: �r^_'�� BUILDING -OFFICIAL: 0+ 4 DATE: DATE: i - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 8/13/2018 5:17 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY (.I-IFrKI IRT RFPn1 T PROJECT Title: Gambina Guest House Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 1335 Lot # Owner Name: Gambina Guest House Total Stories: 1 Block/Subdivision: # of Ulits: 1 Worst Case: No PlatBook: Builder) Name: Rotate Angle: 0 Street: PennitlOffice: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: Port St. Lucie , Family Type: Single-family FL, 34986 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1335 14852 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil, ID Finished Cooled Heated 1 Bathroom 147 1470 No 0 11 Yes Yes Yes 2 Laundry 42 420 No 0 1 Yes Yes Yes 3 Closet 70 700 No 0 1, Yes Yes Yes 4 Bath 28 280 No 0 1 No Yes Yes 5 Kitchen 153 1530 Yes 0 1 Yes Yes Yes 6 Cafe 144 1440 No 0 1 Yes Yes Yes 7 Living Room 369 4428 No 2 1 Yes Yes Yes 8 Bedroom 382 4584 No 2 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist RWalue Tile Wood Carpel 1 Slab -On -Grade Edge Insulatio Bathroom 241t 0 147 ft2 1 0 0 i 2 Stab-9n-Grade Edge Insulatio Laundry 6 ft 0 42 ft2 0 0 3 Slab -On -Grade Edge Insulatio Closet 7 ft 0 70 112 ___ 1 0 0 4 Slab -On -Grade Edge Insulatio Bath 1 It 0 28 ft2 0 0 5 Slab -On -Grade Edge Insulatio, Kitchen 12 ft 0 153 ft' 0 0 6 Slab -On -Grade Edge Insulatio Cafe 26 ft 0 144 ft2 0 0 7 Slab -On -Grade Edge Insulatio i Living Room 38 ft 0 369 ft2 1 0 0 8 Slab -On -Grade Edge Insulatio Bedroom 47 it 0 382 ft' 1 0 0 8/13/20118 5:17 PM EnergyGaugeO USA Section'R405.4.1 Compliant Software I Page 2 of 5 i FORM R405-2017 INPUT SUMMARY CH17MI IST REPORT ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch 1/ # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel tile 1493 W 0 ft2 Dark 0.6 No 0.9 No 20 26.6 ATTIC v # Type - Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1335 ft2 N Y CEILING # Ceiling Type Space R-Value Ins Type' Area Framing Frac Truss Type 1 Under Attic (Unvented) Bathroom 20 Blown 147 ft2 0.1 Wood 2 Under Attic (Unvented) Laundry 20 Blown 42 ft2 0.1 Wood 3 Under Attic (Unvented) Closet 20 Blown 70 ft2 0.1 Woad 4 Under Attic (Unvented) Bath 20 Blown 28 ft2 0.1 Wood 5 Under Attic (Unvented) Kitchen 20 Blown 153 ft2 0.1 Wood 6 Under Attic (Unvented) Cafe 20 Blown 144 ft2 0.1 Wood 7 Under Attic (Unvented) Living Room 20 Blown 369 ft2 0.1 Wood 8 Under Attic (Unvented) Bedroom 20 Blown 382 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height _ Sheathing Framing Solar Below o _ 1 N Exterior Concrete Block - Ext InsuBathroom 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 2 E Exterior Concrete Block - Ext InsuBathroom 4.1 11 0 10 0 110.0 ft2 0 0 0.6 0 3 N Exterior Concrete Block - Ext Insul Laundry 4.1 6 0 10 0 60.0 ft2 0 0 0:6 0 4 E Exterior Concrete Block - Ext Insul ' Closet 4.1 7 0 10 0 70.0 ft2 0 0 0.6 0 5 N Exterior Concrete Block - Ext Insul Kitchen 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 6 N Exterior ConcreWBlock - Ext Insul Cafe 4.1 8 0 10 0 80.0 f12 0 0 0.6 0 7 S Exterior Concrete Block - Ext Insul Cafe 4.1 1 0 10 0 10.0 ftz 0 0 0.6 0 _ 8 SW Exterior Cohcrete Block,- Ext Insul Cafe 4.1 5 0 10 0 50.0 ft2 0 0 0.6 0 _ 9 W Exterior Concrete Block - Ext Insul Cafe 4.1 7 0 10 0 70.0 fie 0 0 0.6 0 10 I NW Exterior Concrete Block - Ext Insul Cafe - 4.1 5 0 10 0 50.0 ft2 0 0 0.6 0 11 S Exterior Concrete Block - Ext Insl iving Room 4.1 20 0 12 0 240.0 ft2 0 0 0.6 0 12 W Exterior Concrete Block - Ext InsLdving Room. 4.1 18 0 12 0 216.0 ft2 0 0 0.6 0 13 E Exterior Concrete Block - Ext InsuBedroom 4.1 21 0 12 0 252.0 ft2 0 0 0.6 0 14 S Exterior Concrete Block - Ext InsuBedroom 4.1 18 0 12 0 216.0 ft2 0 0 0.6 0 15 1 W Exterior Concrete Block - Ext InsuBedroom 4.1 8 0 12 0 96.0 ft2 0 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft, In 1 W Wood Living Room None .39 3 8 24 f12 2 S Wood Bedroom None -.39 2 10 8 22.7 ft2 8/13120 8 5:17 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Pro osed orientation. J Wall Overhang # Ornt ID Frame Panes NFRC U-Factor .SHGC Imp, Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Double Yes 0.65 0.25 N 8.0 ft2 1 ft 7 in 1 ft4 in None None 2 E 2 Metal Low;E Double Yes 0.65 0.25 N &0 ft? 1 ft 7 in 1 ft4 in None None 3 SW 8 Metal Low-E Double Yes 0.65 0.3 N 3.0 ft2 1 ft 7 in 1 ft 4 in None None 4 SW 8 Metal Low-E Double Yes 0.65 0.25 N 12.0 ft2 1 ft 7 in 1 ft 4 in None None 5 W 9 Metal Low-,E Double Yes 0.65 0.3 N 3.0 ft2 1 ft 7 in 1 ft 4 in None None I 6 W 9 Metal Low-E Double Yes 0.65 0.25 N 12.0 ft2 1 ft7 in 1 ft 4 in None None 7 i NW 10 Metal Low-E Double Yes 0.66 0.3 N 3.0 ft2 1 ft 7 in 1 ft 4 in None None 8 NW 10 Metal Low-E Double Yes 0.65 0.25 N 12.d ft2 1 ft 7 in 1 ft 4 in None None 9 W 12 Metal Low-E Double Yes 0:65 0.3 N 3.0 ft2 6 ft 0 in 1 ft 4 in None None 10 W 12 Metal Low-E Double Yes 0.65 0.25 N 24.8 ft2 1 ft 7 in 1 ft4 in None None 11 W 12 Metal Low-E Double Yes 0.65 0:3 N 4.042 1 ft 7 in 1 ft 4 in .None None 12 E 13 Metal Low-E Double Yes 0.65 0.25 N 36.0 ft2 1 it 7 in 1 ft "4 in None None 13 W 15 . Metal Low-E Double Yes 0.65 0.26 N 12.0 ft2 8 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Whilehouse Proposed ACH(50) .000495 1732.7 95.12 178.9 .3958 7 HEATING SYSTEM # ,System Type Subtype- Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 24 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Laundry 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert .# Company Name System Model # Collector Model # Area Volume FEF None None ft2 EnergyGougeO.USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS — Supply -- -- Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area . Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 140 ft2 Attic 45 ft2 DefaultLeakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [ j Jan ((j Feb Feb j j Mar MarAppr [ ] Apr j [ j May ] May [Xj Jun i Jun jXj Jul [ ] Jul ri Aug AugjXj Sep SeppOct W Oct j X j Nov Nov j( Dec XDec VentinggJanl Ventin [ ]Jan [ i J Feb [XJ Mar [X] A r [ J Ma [ ]Jun t [ j Jul Aug Se Oct l[xXJJ Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80` 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78, 78 78 78 78 78 PM 7.8 78 78 78 78 78 78 78 78 � 78 78 78 HeatingD) AM 66. 66 66 66 66 68 68 68 68 68 68 68 7 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 1 PM 68 _ 68 68 68 68 68 68 68 68 68 66 66 MASS ryass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 It 0.3 Bathroom Default(81bs/sq.ft. ft2 ft 0.3 Laundry Defaulqu lbs/sq.ft. ft2 ft 0.3 Closet . Default(8 Ibs/sq.ft. ft2 it 0.3 Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen De1au1t(8 Ibs/sq.ft. ft2 ft 0.3 Cafe Defaunto Ibs/sq.ft. ft2 ft 0.3 Living Room Default(8 Ibs/s .ft. ft2 ft 0.3 Bedroom Name: Rating Compant: i 8/13/2018 5:17 PM .���fllt `♦1 q e. l I EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Gambina Guest House Builder Name: Sir eet: Permit Office: City, State, Zip: Port St. Lucie , FL , 34986 Permit Number: Owner: Gambina Guest House Jurisdiction: w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA Geneial A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. i Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation andahy gaps in the air barrier shall be sealed. The Insulation in any dropped ceiling/soffit Access openings, drop down stairs or knee wall doors to shall be aligned with the air barrier. unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air bamer. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -',garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors)' of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to I exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recesi ed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring- Showeldtub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers prs sealed in a manner that is recommended by the manufacturer. I Caulking or other adhesive sealants shall not be used to fill voids a_ In addition inen rtin of In �n� �ti.,u �.., -- •••--�••••.. , •.+'.....•..•• .• ,vy —1— be 1,, --dal ce WI111 41C IJIUVISI0115 UI 1k L--4UU. 8/14/2018 10:56 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 201iF EPL DISPLAY CARD I ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 4. Number of bedrooms 9. Is this a worst case? (yes/no) 6,. Conditioned floor area (sq. ft.) I 71. Windows, type and area a) U-factor:(weighted average) I b) Solar Heat Gain Coefficient (SHGC) c) Area 8. Skylights a) U-factor:(weighted average) b) Solar Heat Gain Coefficient (SHGC) 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: I A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 3. 1 4. 1 13. Cooling system: Capacity 24.0 a) Split system SEER 16.0 5. No b) Single package SEER c) Ground/water source SEER/COP 6. 1335 d) Room unit/PTAC EER e) Other 7a. 0.650 7b, 0,256 14. Heating system: Capacity 17.0 7c. 140.7 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 8a. NA d) Gas furnace, natural gas AFUE 8b. NA e) Gas furnace, LPG AFUE f) Other 9a. 0.0 9b. 15. Water heating system 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF 10A1. e) Dedicated heat pump with tank EF 10A2. 4.1 f) Heat recovery unit HeatRec% g) Other 1081. 10132. 16. HVAC credits claimed (Performance Method) 111. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11 a. 20.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: 6' Date: i Address of New Home: Z4 nUlA C/ e- City/FL Zip: Port St. Lucie, FL 34986 8/14/2018 10:55:54 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1