Loading...
HomeMy WebLinkAboutLETTER FROM MOORE AND ASSOCIATESt 8 b - 0 Co35 •s i JAN 2019 �• �y � ��� 1iti�a9 �D�p��'tm`�nt County MOORED AND ASSOCIATES ENGINEERING AND CONSULTING 8 January 2019 Tubular Building Systems 631 SE Industrial Circle Lake City, FL 32025 Attn: Mr. Don Little 401 S. Main Street Suite 200 Mt. Airy, NC 27030 Phone: (336) 41 5-3540 Fax: [33B] 71 9-2020 1 009 East Avenue North Augusta, SC 29B41 Phone: [B03) 279-7799 Fax: 003) 279-3B4B www.MandA-inc.com S ANNED co, nty RE: Philliipe Chihas Building 40'-0" Wide x 61'-0" Long x 16'-0" Eave Height Enclosed Building with One (1) 14'-0" Wide x 61'-0" Long x 13'-0" Eave Height Enclosed Lean-to 6106 Silver Oak Drive, Fort Pierce (St. Lucie County), FL 34982 M&A Project No. 18350E Dear Mr. Little: Per your request, Moore and Associates Engineering and Consulting, Inc. (M&A) has developed this letter to address review comments made by the Planning & Development Services- Building & Code Regulation Division of St. Lucie County. A copy of the review comments provided to M&A via email is included in Attachment A. A copy of the building sales order form is included in Attachment B. The applicable master design was noted to be the Enclosed Building- Exposure B- Maximum 40'- 0" Wide x 20'-0" Eave Height- Box Eave Frame, Revision 4 dated 18 December 2017. A copy of the applicable master design with Florida digital seal/signature is included in Attachment C. The applicable master design was analyzed/designed per the 2017 Florida Building Code (FBC) 6"' Edition as well other codes/criteria. The 2017 FBC, 61' Edition is the model building code for the State of Florida and references the 2015 International Building Code (IBC). The 2015 IBC, in turn, references ASCE/SEI 7-10 Minimum Design Loads for Buildings and Other Structures. To verify that the subject building fell within the analysis/design parameters of the applicable master design, M&A obtained site -specific natural phenomena load information from the Applied Technology Council (ATC) website. This informat s '1lu din -Attachment D. COPY National Society of Professional Engineers® As can be seen, the site -specific load information is less than that used in the analysis/design of the applicable master design so long as the roof trusses and columns (legs) are spaced at or less than 4'-0" on center. The geometry of the subject building (i.e. width, eave heights and lean-to width) fall within the parameters of the applicable master design as well. It is our understanding that the subject building is or will be founded on a slab on grade with monolithic turned -down footings. It is assumed that the slab is/will be minimum 4" thick and be reinforced with welded wire fabric (WWF) and/or fiberglass fibers meeting the requirements of the American Concrete Institute (ACI) 318-14 Building Code Requirements for Structural Concrete and Commentary and/or local code requirements. Per Sheet 7A of the applicable master design, the turned -down footing should be reinforced with minimum two (2) continuous longitudinal #4 rebar. The rebar should be fabricated and installed in accordance with Sheet 7a as well as ACI 318-14. The foundation system for the applicable master design was based on the following analysis/design parameters: 1. Allowable soil bearing pressure of 1,500 psf 2. Minimum 28-day compressive strength of concrete = 3,000 psi 3. WWF meets the requirements of ASTM A185 (65 ksi yield strength) 4. Rebar meets the requirements of ASTM A615 (60 ksi yield strength) 5. Cover dimensions meet the requirements of ACI-318-14 If the building is placed on in -situ virgin subgrade, the subgrade should be tested to verify that it is compacted to minimum 95% of maximum density per ASTM D698- Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Standard Effort (12 400 ft-lbf/ft3 (600 kN-m/m3)). As noted above, the in -situ soils must provide a minimum soil bearing capacity of 1,500 psf. If fill material is used, the fill should be a 50150 clay sand mix. The fill should be placed and compacted to minimum 95% of maximum density per ASTM D698. The fill should be placed and compacted in greater than 8" lifts. Although the slab/foundation system and building superstructure are constructed of materials that are not affected by subterranean termites, M&A is unfamiliar with what may be stored within the building and whether those materials would be affected by termites. Thus, if any non -load bearing timber materials are placed within the building and/or if any timber and/or paper products are stored within the subject building, M&A recommends that the grade/subgrade under the building/foundation system be treated for termites. The termite treatment should comply with the requirements of Section 105.10 and 105.11 of the 2017 FBC, 6t' Edition. It is assumed that others will address comments relating to zoning. 2 Please contact me at (803) 279-7799 or (336) 415-3540 if you have any questions or need additional information. Sincerely, MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. MO Wayne S. Moore, P.E. : �'•••.�'�� Senior Civil/Structural Engineer 0 57170 Attachments C: Project File 3 �lr STATE OF : OR I s'••........••' C? O 'Olt 01NA11 E���`` I ATTACHMENT A REVIEW COMMENTS Planning & Development Services Building 8 Code Regulation Division ' 2300 Virginia Avenue Fort Pierce, FL 34982 'hone:(772j462-2172 Fax:(772)462-6"3 Address: City / State Zip: Parcel #: Zoning 6106 Silver Oak Dr Fort Pierce, FI 34982 3402-607-0150.000/2 RS-3 APPLICATION INFORMATION Permit Number: 1810-0635 Permit Type: CARPORT/GARAGE - DETACHED CONTRACTOR INFORMATION Contractor Name: - Business Name: I Business Addr: City / State 1 Zip: , REVIEWS iAND COMMENTS Review Tyne DOCUMENTS MISSING 11/8/2018 Commend ENVIRONMENTAL REVIEW Commend FRONT COUNTER REVIEW Comment: I PLANS EXAMINER REVIEW Commend 11/13/2018 11113/2618 Commend 11/13/2018 Comment: ZONING REVIEW Comment: 11/2/2018 Commend 11/2/2018 REVIEW COMMENTS 1 Owner(s): Gui P. Chibas / Patricia Chibas Jurisdiction: SAINT LUCIE COUNTY Lot#: 19 Block: 19 Stories: • Automatic Sprinkler System? No Fax Number: Status Reviewed By Date Started PENDING Ellen Vaughn 10/29/2018 VEG PERMIT FILED UNDER (C) FOR CHIBAS. NO FEE_ COMPLETE Lynn Swartzel 11/112018 COMPLETE Ellen Vaughn 10129/2018 INCOMPLETE William Durden 11/13/2018 Email: Date Completed Date Released 11/5/2018 11/5/2018 10/29/2018 10/2912018 FOUNDATION REQUIREMENTS ARE NOT SPECIFIED ON THE PLANS. PLEASE PUT ON THE PLANS THE SOIL DENSITY OR SUBMIT GEOTECHNICAL REPORT IN COMPLIANCE WITH R401 OF THE 2017 RESIDENTIAL BUILDING CODE. PLEASE CLARIFY ON THE PLANS IF TERMITE TREATMENT WILL BE REQUIRED. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. PLEASE CLARIFY IF ADDITIONAL FILL WILL BE INSTALLED. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE INCOMPLETE Lydia Galbraith 11/2/2018 SURVEYS ARE REQUIRED FOR ALL BUILDING PERMITS INVOLVING A PRIMARY STRUCTURE AND FOR ALL ACCESSORY STRUCTURES WITH A CONSTRUCTION VALUE EXCEEDING S 10,000.00. THE SURVEYS ARE REQUIRED TO BE SIGNED & SEALED BY A REGISTERED FLORIDA SURVEYOR. THE UPDATED SURVEY SHOULD INDICATE: - PROPOSED FINISHED FLOOR ELEVATION OF THE METAL BUILDING(MIN. REQUIRED IS 18- ABOVE CENTER LINE OF THE ROAD, SEE ST LUCIE COUNTY LAND DEV. CODE CHAPTER 7.04.01 C) - EXISTING ELEVATION OF THE HOUSE - ELEVATION OF CENTER LINE OF THE ADJACENT ROAD -THE MIN. REQUIRED REAR SETBACK IS 15', SIDE SETBACK IS 10'.. Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772,�462-2172 Fax.(772)462.6443 I REVIEW COMMENTS 11/2/2018 comment: PLEASE PROVIDE TWO UPDATED SIGNED AND SEALED SURVEYS INCLUDING BUT NOT LIMITED TO ABOVE COMMENTS. 11/2/2018 Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS. ATTACHMENT B BUILDING ORDER FORM ........................ ... Corporate Office: Main Number: 386 961-0006 631 SE Industrial Circle Fax Number: 386-961-0008 Lake City, FL 32056 tubularbuildingsystems@gmail.com Mailing: PO BOX 2254 Lake City, FL 32056 Sales Order Form ;.............._._..... .... ...... ..... _..._.......................... . Buyers Name(s) Philipe Ch)bas Date 10J17/2018 Address 6106 Silver Oak Drive County Dealer Carport Central -Cameron City Fort Pierce ST FL Zip 34982 Order Received & Verified BV TBS Phone 772-216-4638 Alternate 772-201-7216 Init6W: e-mail philipechibas@yahoo.com Cell Date: f: :: .:;:':':_":: ; ..... :..i to (if different same eriiisof3al Roof Style:::::: Vertical (60' footprint length) length NOTE: Frame lft shorter than roof len h Width: 54 Length: 61 Leg Height: 16/13 Installation :.: Perrnits ;`: yes Povaer.4vailafile? concrete ::....:.... . .:.. . .:...::.-..:.::-:;::•.::.,..-::: -.... yes Color.::; Roof: TBD Sides: TBD Trim: TBD x Base 40x61 Standard $22,285.00 "J" Trim x Base 14x61(lean to) Optional Connection Fee: Side to Side (drop down barn) $300.00 x Leg Height 16' main building 13' low leg leanto $5,925.00 Connection Fee: End to End i x Enclose Both Sides (horizontal siding) $2,770.00 Miscellaneous: x Enclose Each End (hoizontal siding) $5,410.00 Miscellaneous: x Extra Panels (lean to has 20' utility room) $2,275.00 Miscellaneous: Gable Closed: A. Sales Total $45,440.00 x Standard 36" x 80" Walk-in Door - No Window (2) $475.00 B. 4' OC Pricing Option (Sales Total x5%) $0.00 Upgrade Door C. Sales Tax (A & B X Sales Tax Rate) Rate `. 6% $2,726AO Standard Window- 24" X 36" - Mill Finish D. Additional Tax Over $5,000 (25,50,75) $25.00 Upgrade Window E. S6btotal (A+ B + C + D) $48,191.40 x Garage Door: Size (W'XH') (2)14x14 $4,400.00 F. Deposit (A & B X Deposit Rate) Ratef . 16% $7,270.40 x Garage Door: Size (W'XH') (1)1Ox10 $950.00 G. Total Less Deposit (E - F) $40,921.00 x I Garage Door: Size (W'XH') 1 Bx8 $650.00 H. Site Specific Plans $0.00 Frameout - Window I. 1 Lift Rental Fee jFrameout - Door I Additional Labor Fee(Return Trip, Install over etc.) $0.00 Frameout- Garage Doo K. Balance Due To Tubular Building Systems $41921.00 Header for Side Entrance L Additional Money Down (Collect From Dealer) $0.00 i Side Frameout- Square M Collect Money From: $40,921.00 Side Frameout- 4S* (Plus Side Closed Price) -If Collecting From Dealer Collect L+M'xCollecting From Customer Collect JAM from Dealer Please send drawings to customer ASAP for permitting and ground prep. If permitting is denied deposit will be refunded 100% 17OMPH wind Please see attached drawings for door placements: (I) walk In door placed between lean to and main building inside utility room 214X14 & 110x10 to have interior latch. 18x8to have exterior latch.14x14's evenly spaced on front end wall,10x10 centered on back end wall •��- ��r ••=••"ate •••w�=�� �. +�� a�++o�.a,auun d—e auaress or ouyer sutea aaove upon the receipt or the run purcnase price. The buyer is responsible for properly preparing the site for installation, obtaining any required permits and all otherTerms and Conditions. Tubular Building Systems IQ - PhMpo Chi a5 (Oct 1712018) ATTACHMENT C APPLICABLE MASTER DESIGN Digitally signed by Wayne 5 401 S. Main Street, Suite 200 Moore Mount Airy, NC 27030 Date: 7017.17.21 07:53:44-05'00' MOORE AND ASSOCIATES ENGINEERING AND CDNSUI-TING STRUCTURAL DESIGN ENCLOSED BUILDING EXPOSE D i MAXI BEM 409-099 WIDE X 20'-0" SAVE HEIGHT- BOX SAVE FRAME 18 December 2017 Revision 4 M&A Project No. 16022S/16072S/16073S/17301S Prepared for: Tubular Building Systems, LLC 631 SE Industrial Circle Lake City, Florida 32025 Prepared by: Moore and Associates Engineering and Consulting, Inc. 1009 East Avenue Nor#h Augusta, 5C 29841 E N No 57170 O STATE OF �11 f111111 This item has been electronically signed and seated by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. r� i I I SST %PyNE S. ENg�.;4� No 57170 O :. S TAT E OF .'�4/ A,C 0 A I •'�S'`S��fV A `��.��•` ,nn This item has been electronically signed and sealed by Wayne S. Mcore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. MOORS AND ASSOCIATES ttrr gas TUBULAR BUILDING SYSTEMS ENGINEERING AND CONSULTING, INC. PE COVER SHEET 40•-0"x2V-0" ENCLOSED BUILDING EXP. B D BV- PDI THIS DOCDrNi IS THE rRUMOT Or HM -AND •MIAIEL M THE IMWTHIMIND REPRDDIiCTIM COP"W& OR 0"COVISE un or "as DD UNDO I! CT Nib VSH DATE- 12-16-17 E- NTS 173015 B N4 Ii6122S IENT. T S ISHT, I iDwr. ND REV.% 4 LTTDAL IACTIO�IL IDITC0 AND Am D/NINOM"T MRE" MY K SUBACI TO DRAWING INDEX SHEET 1 PE SEAL COVER SHEET SHEET 2 DRAWING INDEX SHEET 3 INSTALLATION NOTES AND SPECIFICATIONS SHEET 4 TYPICAL SIDE AND END ELEVATIONS SHEET 5 TYPICAL RAFTER/POST FRAME AND SIDE FRAMING SECTION SHEET 5A TYPICAL RAFTER/POST FRAME AND SIDE FRAMING SECTION SHEET 6 TYPICAL RAFTER/POST CONNECTION DETAILS SHEET 6A TYPICAL RAFTER/POST CONNECTION DETAILS SHEET 7A BASE RAIL ANCHORAGE OPTIONS FOR LOW AND HIGH WIND SPEED' SHEET 7B OPTIONAL FOUNDATION ANCHORAGE FOR LOW AND HIGH WIND SPEED SHEET B BOX EAVE RAFTER END WALL AND WALL OPENINGS SHEET 9 BOX EAVE RAFTER SIDE WALL AND WALL OPENINGS SHEET 10 BOX EAVE RAFTER WALL OPENING DETAILS SHEET 11 BOX EAVE RAFTER WALL OPENING DETAILS SHEET 12 BOX EAVE RAFTER LEAN-TO OPTIONS SHEET 12A BOX EAVE RAFTER LEAN-TO OPTIONS AND DETAILS SHEjET 13 BOX EAVE RAFTER VERTICAL ROOF/SIDING OPTION SHEET 14 BOX EAVE RAFTER VERTICAL ROOF/SIDING OPTION SHEET 15 OPTIONAL HEADER Q�N • �O �'. No 57170 0 STATE OF :4U This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. MOORE AND ASSOCIATES oal►vN Illy, Jos TUBULAR BUILDING SYSTEMS INEERING AND CONSULTING, INC. D BV- PON 40'-O"x2O'-o" ENCLOSED BUILDING E". B MW IS UC ITT W tIC MI ASSWIMTCL DC Tr[ i 173015 12Cf1 IOM- l�TOta. W OtKwISC IRC w THIS McLov If CT wab VSN DATE- 12-10-17 - NTS NO 160M INSTALLATION NOTES AND SPECIFICATIONS 1 DESIGN IS FOR A MAXIMUM 40'-0' WIDE x 20-0- EAVE HEIGHT STRUCTURES 2 DESIGN WAS DONE IN, ACCORDANCE WITH THE 2014 FLORIDA BUILDING CODE (FBC) 5TH EDITION, 2017 FBC 67H EDITION, 2012 INTERNATIONAL BUILDING CODE (IBC), AND 2015 IBC (U.N.0) 3 DESIGN LOADS ARE AS FOLLOWS% A) DEAD LOAD = 1.5 PSF B) LIVE ILOAD = 12 PSF C) GROUND SNOW LOAD = 10 PSF 4 LOW ULTIMATE WIND SPEED 105 TO 140 MPH (NOMINAL WIND SPEED 81 TO 108 MPH), MAXIMUM RAFTER/POST AND END POST SPACING = 5.0 FEET. 5. HIGH ULTIMATE WIND SPEED 141 TO 170 MPH (NOMINAL WIND SPEED 109 TO 132 MPH) MAXIMUM RAFTER/POST AND END POST SPACING ' = 4.0 FEET. 6 RISK CATEGORY 1. 7. WIND EXPOSURE CATEGORY B. 8 SPECIFICATIONS APPLICABLE TO 29 GAUGE METAL PANELS FASTENED DIRECTLY TO 2 1/2' x 2 1/2' - 14 GAUGE TUBE STEEL (TS) FRAMING MEMBERS. FOR VERTICAL PANELS, 29 GAUGE METAL PANELS SHALL BE FASTENED TO 18 GAUGE HAT CHANNELS (U.N O). 9 AVERAGE FASTENER SPACING ON -CENTERS ALONG RAFTERS OR PURLINS, AND POSTS, INTERIOR = 9' AND END = 6', (MAX) 10• FASTENERS CONSIST OF n12-14x3/4' SELF -DRILLING FASTENER (SOF), USE CONTROL SEAL WASHER WITH EXTERIOR FASTENERS SPECIFICATIONS APPLICABLE ONLY FOR MEAN ROCF HEIGHT OF 20 FEET OR LESS, AND ROOF SLOPES OF 14' (3;12 PITCH) OR LESS SPACING REGUIRENENTS FOR OTHER ROOF HEIGHTS AND/OR SLOPES MAY VARY It GROUND ANCHORS CONSISTING OF a4 REBAR W/WELDED NUT x 30' LONG MAY BE USED FOR LOW WIND SPEEDS ONLY. 12 GROUND ANCHORS (SOIL NAILS) CONSIST OF 44 P,EBAR W/ WELDED NUT x 30' LONG IN SUITABLE SOIL CONDITIONS OPTIONAL ANCHORAGE MAY BE USED'IN SUITABLE SOILS AND MUST BE USED IN UNSUITABLE SOILS AS NOTED SOIL NAILS ARE NOT ALLOWED FOR HIGH WIND APPLICATION. 13 GROUND PNCHORS SHALL BE INSTALLED THROUGH BASE RAIL WITHIN 6- OF EACH RAFTER COLUMN ALONG SIDES AND ENDS 14 OPTIONAL BASE RAIL ANCHORAGE MAY BE USED FOR LOW AND AND MUST BE USED FOR HIGH WIND SPEEDS 15 WIND FORCES GOVERN OVER SEISMIC FORCES SEISMIC PARAMETERS ANALYZED ARE SOIL SITE CLASS = D RISK CATEGORY 1/11/111 R=3.25 (E =1.0 SOS = 1,f522 V = CSW Soi = 0.839 MOORE AND ASSOCIATES PEERING AND CONSULTING, INC. No 57170 O STATE 'OF ............ %% fllll This item has been electronically signed and seated by WayneS. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 40'-O"x2O'-O" ENCLOSED BUILDING EXP. B Is r1�2 BOX SAVE FRAME RAFTER ENCLOSED BUILDING WINDOW CAS APPLICABLE) DESIGN PRCSSUW LOW • C218 PSF. -23.6 PSh HIGH • C32.05 PSF. -35.6 PSF) . y _.—_.. q ........a...:�_�,-mac._ ...... ,.,.—y...... _. �• LENGTH VARIES DEPENDING ON TYPICAL SIDE ELEVATION -HORIZONTAL ROOF SCALE, 1/B' = 1'-0' Rau -UP DGER SWINGING DaGR tAS APPLICABLE) (AS APPLICABLE) DESIGN PRESSURE �BCSIFili PRESSURE LOW • (1%5 PSF, -200.4 PSF) LOW • t20.8 PSF, -2E.6 PSF) FIGH • (27.95 PSF. 40.7 Psr) HIGH • (3135 PSF, -34 IS PSh 1 - 40'-Cr M"INUM RAFTER SPAN 1 TYPICAL END ELEVATION -HORIZONTAL ROOF SCALE 1/8' " V-0' MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. NU =Mff IS THE FVAMft W HH) K AM ASSOC1ATE31. W_ THE IIWTT MIND O TgMICTIft WI I)4 CR GTKavISE OU W 114IS ➢ MPCO 32 6' No 57170 i v • i1 z STATE OFIQ 4(J This item has been electronically signed and seated by Wayne S. Mcore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 40'-0"x20'--0" ENCLOSED BUILDING EXP. B TYPICAL RAFTER/POST FRAME SECTION SCALE, 1/8' = I -D' ly�iN VaR]CS DE'rENDiPoG EQ! SEE MWES (PAGE 3) FOR MAXWtOt SPA[DyG I 7 TYPICAL RAFTER/POST SIDE FRAMING SECTION SCALE, Me' = 1'-Y MOORE AND ASSOCIATES PEERING AND CONSULTING, INC. R u TFfe p" ®I emR wssncwTa Tic TIC w4aafcnow 91FU n am se use of Tilts 6ocu m Is 113111190 MID "V IIfSiPN'i W INCIUM MAY W FACT TO ®,��gaaQss®aias�li S. �s�r ,ae E At s as NO 57170 ° • X Z TATE OF .a44/ A do 6/0 Thts item liar bean electronically signed and sealed by Wayne S. Wore, PE. using a Digitat Signature and dafe. Printed copies of this document are not considered signed and sealed and the signature must be verified an any electronic copies. TUBULAR BUILDING SYSTEMS 40'-0"x20'-0" ENCLOSED BUILDING EXP. B TYPICAL RAFTER/POST FRAME SECTION SCALE, 1/9' = l'-0" TYPICAL RAFTER/POST SIDE FRAMING SECTION SCALE ;Ile' a 1'-0' MOORE AND ASSOCIATES INEERING AND CONSULTING, INC. /Olt If 11[ PWWW1f W ItCa[ AU® Affomms. NC IK RC® ➢IICTIOK COrtW.- Do OfltRV= tdl w IMIS I w"m is 'milm'Ke m Allr U!lltg .0 itKgttlp� IMr K �Ul.t;CT 10 s No 57170 + V . � r • STATE OF �/' 41 ID This .tem has-been electronically signed and sealed by Wayne S. Wore, PE using a digital Signature and (Mate. Printed copies of this document are not considered signed and sealed and the signature muss be verified an any electronic copies_ TUBULAR BUILDING SYSTEMS 4O'-0"x2V-0" ENCLOSED BUILDING M. B f /f IS PQSTJ 16 W. U-CHANNEL BRACE BOX SAVE RAFTER/CORNER POST CONNECTION DETAIL FOR HEIGHTS 10'-0- r, 16'-0- SS PpjT MINIMUM 4' LONG, MINIMUM 13 GA, I NIPPLE SECURE PAST to NIPPLE ,,ITN E !0 ]r)6 RAIL 3/16 IS CONTTNUQUS BASE RAIL E)fST/BASE ® RAIL CONNECTION DETAIL SCALE NTS MOOtE AND ASSOCIATES 1EERING AND CONSULTING, INC. IT 13 ne PMOTT or "wK Iwo 11SSQIAM. M TUC 11MMIL Ei "wh of MMWISE um IF TIQS DalND" Is 31 16 wIPFLC TO T5 BOX [Av[ pnr TCR RAr `CD 7/16 TYP �JJ-J�{Yii "IN]" 6' LCNG,— NtN)NUM 14 GA, IS NIFPLC :[CU^+E PGST T TO NIPPLE WITH 0) et2-laY3ra' SDT (TYP> TS FwT- I8 GA U-C~JEL BRACE 3-t2 r TYP 3-T2 EEURE 'ttiH 1 (4) s12-t4.3,4' F` ssr (CACN END) BOX EAVE RAFTER/CIIRNER POST CONNECTION DETAIL. FOR HEIGHTS j 10'-0* SCALE: HIS SECURE WITH -� (a) 31�-14CRaRN]ra' SIT AT EACH END (8 P£p DRACE) t[Pp.Y tlNE. SHOWN iTSi Ct.lpliri BRACE COLUMN AND BRACE SECTION SCALE- NTS ®®��Qd0t1l9SiAI a � No57170 STATE OF .'�U�m This item has been electronically signed and seated by Wayne S. Moore, PE. using a Digital Signature and dale. Printed copies of this document are not considered signed and seated and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 4W-0"x20'-0" ENCLOSED BUILDING EXP. B 3/t6 NO°PLE TO RArTCR 7/Ifi TYP VSECURE TS BOX EAVE RArTCR/ 7/IS 1rP " �'- i 7/tti J, YJ• TS S➢r (EACH END) T8' GA. 0 CHXWIEL BRACE ATTACH To %. -Cog PANU Pa1NT i31 RAFTER PAST E.SEE MACE SEEF1aN FOR. END ATTACNMEPM I i TS Ct�RD m r BOX EAVE RAFTER/CORNER (D POST j "HON DETAIL FOR _j SCALE' "TS 1s z vz,a az 14 LA a 0 IS PDST MINIAu" 6• L04U. 11".iXTN 33 CA, 7JIfi TS NIPPLC ECURE POST TO NIPPLE 7/Ifi� WITH 141 Ale-14.7/4• e o sar Ts CON17rAIIus o• ° SAIL RAIL 2 POST/BASE RAIL CONNECTION DETAIL SCALE NTS MOORE AND ASSOCIATES PEERING AND CONSULTING, INC. !T IS THE PMKRTV O' ICE MO AS=IATES, ITC, TIC AClgppICTIOI CDTrpIG Q OTepY15C IKC TIaS DODAENT IS NIStTCD ATTt1 APir tTfEilltiilENT 7iEOgAp1 wr K SLMJCET TO ref Hl EHIC SOf AT EACH END r8 PER .TRACE) faiiY ENE SHDWN 102 ELARli vy I::] - to CA U-CHANNEL BRACE 2 7/2• FASTE"Ca TD NIE COLUMN AND R➢Dr ➢FAH. BRACE SECTIGN SCALE, NTS +�°"��eJIT4 S �i 1 440 ,oF, .'` - 0 �1' > " ' 4% e NO 5A-f f 70 per i STATE OF ; 4U OR tA may. p DIEli4 This Aem has been electronically signed and seated 67YA Me S. More, PE. using a Digitab Signature and Mate. printed copies of this document are not considered signed aatrisealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 40'-0"x20'-0" ENCLOSED BUILDING EXP. B RASE RAIL ANCHORAGE OPTIONS FOR LOW AND HIGH WIND SPEED VARIES INSTALL 1/2'.6 3/4' EXPANSION ANCHOR 2' WASHER THROUGH RASE RAIL WITHIN 6' DF EACH POST AND STAGGER ANCHOR ON EACH TOP OF ASPHALT SIDE OF COLUMN POST - DRILL 3/4• DIAMETER HOLE PAVEMENT OR FIBERS I GROUND SURFACE TECtRIEi THE RASE RAIL AND WF OR FIRERGLASs S/E8'DIAMETER TO HCR EYE VIT14 WTHROUGH BOLT Cn q CMBE7R(EHT I i (TYP3 Ll I`_� MUNCLlTMIC CONCRETE FOOTIN (3000 PS.D NIN3 REINFORCED <_ WITH (2) Hs•s CTF) muduS0- FIA,F_ ONCRETE MONOLITHIC SLAB RAIL AN HORAG CALE NTSMINIMUM ANCHOR EDGE DISTANCE IS 4') s COORDINATE WITH LOCAL CODES/ORD GENERAL NOTES CONCRETE: CONCRETE SHALL HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF 3,OOD PSI AT 28 DAYS COVER OVER REINFORCING STEEL: FOR FOUNDATIONS, MINIMUM CONCRETE COVER OVER REINFORCING ORS SHALL BE PER ACI-318 3 INCHES IN FOUNDATIONS WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH THE EARTH OR EXPOSED TO THE EARTH OR WEATHER, AND 1 1/2 INCHES ELSEWHERE REINFORCING STEEL: THE TURNDOWN REINFORCING STEEL SHALL BE ASTM A615 GRADE 60 THE SLAB REINFORCEMENT SHALL BE WELDED WIRE FABRIC MEETING ASTM A185 OR FIBERGLASS FIBER REINFORCEMENT REINFORCEMENT MAY BE BENT IN THE SHOP OR THE FIELD PROVIDED: I REINFORCEMENT 1S BENT COLD, 2 THE DIAMETER OF THE BEND, MEASURED 13N THE INSI➢E OF THE ,BAR, 1S NOT LESS THAN SIX -BAR DIAMETERS 3 1 REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT 'BE FIELD BENT HELIX ANCHOR NOTES: I FOR VERY DENSE AND/OR CEMENTED SANDS, COARSE GRAVEL AND COBBLES, CALICHE, PREL13ADED SILTS AND CLAYS USE MINIMUM (2) 4' HELICES WITH MINIMUM 30 INCH EMBEDMENT 2 FOR C13RAL USE MINIMUM (2) 4• HELICES WITH MINIMUM 30 INCH EMBEDMENT- 3 FOR MEDIUM DENSE COARSE SANDS, SANDY GRAVELS, VERY STIFF SILTS AND CLAYS USE MINIMUM (2) 4' HELICES WITH MINIMUM 30 INCH EMBEDMENT 4 FOR LOOSE TO MEDIUM DENSE SANDS, FIRM TO STIFF CLAYS AND SILTS ALLUVIAL FILL USE MINIMUM (2) 6' HELICES WITH MINIMUM 50 INCH EMBEDMENT 5�FOR VERY LOOSE TO MEDIUM DENSE SANDS, FIRM TO STIFFER CLAYS AND SILTS, ALLUVIAL FILL USE MINIMUM (2) 8' HELICES WITH MINIMUM 60 INCH EMBEDMENT MOORE AND ASSOCIATES INEERING AND CONSULTING, INC. LENT 19 THE WIdERTV d' NMM ATgDED" ES. OL THE IZED HICPYOO 11CI6 COP71N6. Olt OTt[RWIIIC -I Q IWIS DOCUMENT IS TS CONTINUMIS—i RASE RAIL HELD' EYE ANCHOR (SCE NOTES BELOW? 3 B GROUND BASE HELIX ANCHORAGE SCALE• NTS (CAN BE USED FOR ASPHALT) i 4�`��''�.�c' E N ' 4�` •� i No 57170 �O STATE OF :�� `. /1111 This item has been electronically signed and seated by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of thi document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 40'-O"a2O'-O" ENCLOSED BUILDING EXP. B D OPTIONAL FOUNDATION ANCHORAGE FOR LOW AND HIGH WIND SPEED INSTALL 1/20 ANCHOR ZTHROUGH BASE RAIL 2 1/4• 1 1/2- R ]FIBERGLASS EN EACH POST (SEE DETAIL VC INSTALL 1/2-0 ANCKEIR RCB THROUGH (TYP) BASE RAIL WITHIN V or EACH POST ..�.�I I I/r AND STAGGER ANC)<RI DN EACH SIDE Imo— Or COLUKN POST (SEE DETAR •C•) CVVr OR ]FIBERGLASS rISERS GRADE MINIMUM V -- EMBEDMENT ... MI>NDLITHIC CONU(EtE rMr]NG =11 PSI MEW REINFEIRCED -- WITH (2) 94•1 CONTINUOUS INCRETE MONOLITHIC SLAB E; RA I AN i H RA SCALE NTS CMINIMUM ANCHOR EDGE DISTANCE 1S 1 1/21) ■ COORDINATE WITH LOCAL CODES/ORD GENERAL NOTES CONCRETE: COkRETE SHALL HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF 3,000 PSI AT 28 DAYS. COVER OVER REINFORCING STEEL: FOR FOUNDATIONS, MINIMUM CONCRETE COVER OVER REINFORCING BARS SHALL BE PER ACI-31& 3 iINCHES IN FOUNDATIONS WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH THE EARTH OR EXPOSED TO THE EARTH DR WEATHER, AND 1 1/2 INCHES ELSEWHERE REINFORCING STEEL: THE TURNDOWN REINFORCING STEEL SHALL BE ASTH ASI5 GRADE 60; THE SLAB REINFORCEMENT SHALL BE WELDED WIRE FABRIC MEETING ASTH AIRS OR FIBERGLASS FIBER. REINFORCEMENT REINFORCEMENT MAY BE BENT IN THE SHOP OR THE FIELD PROVIDED - I -REINFORCEMENT IS BENT COLD. 2 THE DIAMETER OF THE BEND, MEASURED ON THE INSIDE OF THE BAR, IS NOT LESS THAN SIX -BAR DIAMETERS. 3.'REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT 'BE FIELD BENT MOORE AND ASSOCIATES PEERING AND CONSULTING, INC. Is MINIMUM 6• , � j !� CMBECMENT - ' � - IC CONCRETE TOUIW.- MIN.) RE(MORCED APs CWTINUBS - —_ CONCRETE MONOLITHIC SLAB 1$ A RA AN H RA SCALE NTS CMINIMUM ANCHOR EDGE DISTANCE IS i 1/2') ■ COORDINATE WITH LOCAL CODES/ORD. T/CONCRETE 1/B HEX NUT ANCHOR ROD THROUGH BASE IC RAIL DETAIL SCALE• NTS I No 57170 :� :• STATE OF QJ :,`0NA &--% This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 40'-O"x20'-0" ENCLOSED BUILDING EXP. B BOX EAVE RAFTER END WALL AND WALL OPENINGS is TRUSS NO CS GE A TYPICAL B13X EAVE RAFTER END WALL FRAMING SECTMN SCALE 1/9' = V-V SEE MIES (PAEZ 7) FOR rS NUSS TYPICAL BOX EAVE RAFTER END WALL OPENINGS FRAMING SECTION SCALE, 1/8- - 1'-0- MOORE AND ASSOCIATES INEERING AND CONSULTING, INC. IIOR Is lee N we" a' 1ME ma I► MMICS. Wn lee me WICK EOAI)a 01 0" w= WE or "n 01 MIT Is rmM 90 fm MR 1WRII6EM" "Emoo1 1Mv Ir suettr m ®�eeeeeaa�aaarr®�°ji o4s �E �� psi ` no 57170 s . s STATE OF fir+ s i �.�� RR, ��'®e This ;tetra has been efec2ronicaflp signed and seared byWayne S. Pwore; PE. using a Digita) Sigrtmre a 6dale. POwee_d copies of thi, document are not considered signed and sealed and the signature must be verified on any efectronic copies. TUBULAR BUILDING SYSTEMS 40'-0"x20'-O" ENCLOSED BUILDING EXP. B BOX EAVE RAFTER SIDE WALL .,AND WALL OPENINGS IiNG MN VWDVV 4 KADER AND WINDtlV .. M30 APPLICADLE NO VALLD TYPICAL BOX EAVE RAFTER SIDE WALL OPENINGS FRAMING SECT113N SCALE, ±/e- = V-o• i i i MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. tNts oocu ►r is rK ins W Omer "I Assioa UL PC ne u�wnaRixo i1plp0utn0i4 ea.m m tmaevise use w "S o0mKW is a'IS161iirrrrs job No 671i70 a, s s ++ e s � w s �. A- �? o ri����� rrr>sd This item has been electronically signed and seated by Wayne& Wore, PE. using a Digitaf Signature and date. Printed copies of this document are not considered signed and sealed and she signature must be verified an any electronic copies. TUBULAR BUILDING SYSTEMS 40'-0"x20'-0" ENCLOSED BUILDING EXP. B i BOX EAVE RAFTER WALL OPENING DETAILS IS BDx 11EAVE RAFTER - TS POST (CORNER) HiNIMUR 6' LONG, NINIKU." 4 15 GA. 7S RIPPLE. S£CD9C IS WITH (Rr s[2-t4a3/+' Safi OST 2-a2'712' 15 GA- WGL£ GA. ANGLE CLZP CLIP SECURE TO CCLUM -3/16 O POST AND �'tiMER SECUREO EITHER AND RAFTER WITH, f4t NIPPLE t0 SDF'S BASE 1, 16 GA. C61P ANTLE EAC£R, DR BOTTOM e@zT-14r7/4' 7/16 SEL11aE Td RAFTER POST WINDOW RAIL W[in + a RND M C A;a[L, VI('4y +• SDF sT2•t+n3/4' SDrS IS END COLtPvf "'Tr TRUCTURAL HC.'CER Wr1TG`A= SSE RAIL Ol WUibOW RAIL E®ST®RA�"TER C �,C�ONN�ECTION DETAIL TS I 'S TRUSSLBRaFTER ENDRD, ETR HEADER' I I &END POST/BASE RAIL HEA�- R WINDOW RAIL TDt IIDa➢Ilt[£ECTI®1l DiETAIL POSNECTION DETAIILALE f7TS SCAL IS END POST UA 2•R2'x2' 16 GA ANGLE CLIP ODOR WINDOW SECURE TO POST LEACH rRAs1E POST SIDE) AND RAFTER CHDRWRAIL WITH RIP-14.3/4- SUP 2 ON DOTYCM AND a ON STCE NOTE- AT ROLL -UP DODR OPENINGS. POST SHUMD BE TS NQN-STRRUCTURa6 FLUSH WITH RAIL END- CLIP HEADER, BASE RAIL, POST TO RAIL ONLY W SIDE rra u.—i c•tr OPPOSITE THE OPEMNS. TS Box RAFTER IS 7/14 ' 1 TS ITU CAVE 3116 RAFTR Ts C1IIRD POST TO HEADER, BASE RAIL. OR WINDOW RAIL CkORD/RAFTER cEl�llt9ECTI�II� DETAIL C®UNECTI®e',t II2ETAIIL SCALE NTS 5CA E•. ?d'S TRUSS POST AND CORD TO RAFTER Esc -- ALE' NTS i toSS491TB9pr11 E Al No 57170 r >-:0 % STATE OF ;�4/Z This kem has-been electrontrallp signed and seated by Wayne 5. Moore, PE. using a Digital Signature and date. Printed capiies of this document are not considered signed arctsealed and the stgrreure must be vedfied on any electronic copies. MOORS AND ASSOCIATES IXAVX By$ AS TUBULAR BUILDING SYSTEMS ENGINEERING AND CONSULTING, INC. Dwxazi w. Pzm 40'-0"Y0'-0" ENCLOSED BUILDING EXP. B TMS DOCLIOC S TIC F6001T Or DOW NO A=JAIM ILK. T1t CT WA ws" DATE- 18-1®-17 D NTS Na 95�o22S 111MiT1�iIND 1CrrMODWT1Ob CO"[w OQ Orl99V1SC IIRC w 11i1S DD xww if �TRIQTLT' gtI1.0 AMAMf DIF'MMDCM[MT TKKUPON MT K SULIECT TO _-- _ BOX EAVE RAFTER WALL OPENING DETAILS 3116 L NIPPLE TO S P13ST wEADER 3n6 MINIHuw 6• LDNG, 72 PDST NIPPLE 7D 3iI6 NIPPLE 10 7i16 MINIMUM 13 GA., TS MEADER 7Y16 DASC RAIL 3i36 a > WITH,MIPPLE. SEGURE EACH Vltw c47 >t12-14a7/4• 0 0 ' SCr 6' LUNG, M'INIMIMIS CA, TS MIPPLE SECURE IS caurju4mS pt MINIMUM 6• LONG, 4 VITR (4) I12-144/4' SDP SASEMINIMUM iS GA., TS NIPPLE. SECURE EACK�q VITw (4) ole-14°3/0• SDr TS P13ST 3-� DIDUDLE.TS F.tpu"2R DOUBLE HEADER/POST POST/DCUDL£ HEADER POST/EASE RAIL 10 CONN CT OIL DETAIL 11 CQNNECTiON DETAIL 12 �®NNECTION DETAaIL SCALE NTS SCALE NTS SCALE, NTS i v4 X 2 6ir 14-CA M&ECTOR LEEVE WITH (6) 12'14a3/4' SCr S eSPLICE CONNECTION DETAIL SCALE NTS Nrt��po57170 s m• ad j d - it • s vt STATE aF :j.40� Thia;tern has been eressronlcalry signed and seafed Ire Wayne S. I13core, FE. using a Digital Signature and dWe. Printed copies of this document are rice considered srg,Ted ardseared and she signature must be verified an azre electronic copies. MOORE AND ASSOCIATES time w• in TUBULAR BUILDING SYSTEMS PEERING AND CONSULTING, INC. cItED ay. pmt 40•-a-x2O'-a" ENCLOSED BUILDING EXP. B T IS TT[ TM PIUXVT DT M®D MD ASSDiIATM GC T1[ 160 RE MDDIICT1p1, CDPTIML at OTTtAr1SC UK DT 1111% M"DM1 IS CT IiJt+ VSII GATE, 1H-18-17 CALE, TITS M 16D2�5 141111193 AMII MIT It/MINUM UT TM[DdIRr MT W ZULYCT TO RLOr EXLENSIOIR OPTION MAIN SLRtf-TUPC TS TRUSS STANDARD LLAN-70 OPTION TYPICAL BOX SAVE RAFTER LEAN—TO OPTIONS FRAMING SECTION SI30T?i CPTIONS SHOWN) SCALE: NTS (:MAXIMUM WIDTH OF SINGLE MEMBEP. RAFTER LEAN-TO IS (MAXIMUM WIDTH IIF DOUBLE MEMBER RAFTER LEAN-TCf IS 16'-0*.� /15�;' ar 3Jf6TP rRAFTCR TS MY CAVE NIPPLE RAFTER MINLMLIN 6' LONG, MINIMUM 15 GA. •• NIPPLE. POST i0 NI 14) tl NIPPLE WITH 141 2O14x3/Sti 6' 24' IS GA. U-CNAMxCL BRACE 95• TO B' RAFTCR POST] CR 41P 18 GA. U-04ANPXL BRACE (4• TO 16.1 RN TER POST) SECURE WITH <4) oL2-14.3/4' SDF (C&C14 CND) iS POST LEANS —TO RAFTER/ CORNER POST DETAIL I SCALE, NTs n 2'.2•X2' I6 GA. ANGLE CLIP SECURE 10 POSI AND RAFTER WITH 012-14.3/4' SOF 2 ON 70P AND 2 ON BOTTOM —IS RAFTER 1c LONG % 13 GA NiPPLC. SCCUx'E POST _ TO NIPPLE l7N - (4) *1 J- .V3N• SCfi 4 4 o' rS EXTENSION 6• r ]•t2 RAFTER 3.12 IS POST SIDE EXTENSION RAFTER/COLUMN DETAIL FCC RAFTER SPM < l;—W SCALE- NTS -IS POST MINIMUM 4' 1.1511G. M1141MUM 13 CIA. IS NIPPLE SECURE WITH a) 212-14.3/4' SDF CONTINUL4IS BASE RAIL Ly --is POST LEAN-TO RAFTER TO RAFTER COLUMN CONNECTION DETAIL LEAN—TO POST L FOR RAFTER SPANS a2'—Q' CONNECTION DETAIL 16 SCALE: NTS SCALE NTS MOORE AND ASSOCIATES oaAVn By..,as ENGINEERING AND CONSULTING, INC. 0 p.1 PON nRls OOW[Nt Is 11[ !!O!LlTe Q IWdt (coo ASSOc1Af[s. INC DIC CT WA VSK JNIWn10Rittb OVRDIICTIAN, �tUt!•rr Oi OiKYYIs[ IRE Ott 181s is ,s®111551aaaiBA°r No 57170 s STATE OF . 41 ` This item has been etectronicalty signed and seated by Wayne S. Mcore, PE. using a Digitaf Signature ardeate. Printed copies of this document are not considered signed and sealed and the signature must be verged on any electronic copies. TUBULAR BUILDING SYSTEMS 40'-0^x20=0" ENCLOSED BUILDING EXP, B NIPPLE TO 3/16 RATTER TS BOX EAWC 3/16 RAFTER 2'.2'X2' 16 GA. ANGLE CLIP 12' LONG TS 15 GA. Ir SECURE .TO POST AND NIPPLE SECURE POST RAFTER WITH 112.14.3/4• 10 NIPPLE WITH SDr (°) +12-14*3/4' SBf - 2 ON TOP AND 2 ON BOT113H ° IS RArTER 6. IS DOUBLE TIP 3.12 EXTENSION RArTER .12 TS POST 2'•2'+2' 16 GA. ANGLE IS POST 3-12 irP CLIP SECURE M COLIA[N 3_12 AND RArtER WITH fQ +12-14+3/4' SDr S LEAN-TO RAFTER TO RAFTER SID�R"A TENSION RAFTER/COLUMN DETAIL COLUMN CONNECTION DETAIL FOR FOTER SPANS 12'-0' C L S 16'-0' RAFTER SPANS 12'-0' < L < 16'-0' �SA SCA16A SCALEa NTS MOORE AND ASSOCIATES PEERING AND CONSULTING, INC. R IS THE 1PROPCOTY Or 1=K 04 ATSRIARS. INC THE IBM DOM"M MITT 11[=/� II11� K $US.7 TO It Ne1S1IAwfOO,,,, No 57170 r STATE OF f1111 This stem has been electronically signed and sealed by Wayne S. Moore, PE using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 40'-0"x20'-0" ENCLOSED BUILDING EXP. � B 12-19-17 D NTS ND IIIXP�S BOX EAVE RAFTER VERTICAL ROOFISIDING OPTION t TYPICAL END ELEVATION VERTICAL ROOF SCALE: 1/8' = P-0' 24 GA. LALVoLN ID SETA_ RWF PLELS rASTEWD 41 PLMINS is VMS t3' to GAUGE rURRM CHANUEL CPURLINi _ 48- 'Sc. AAA 40'-0' MA%(WUN RAr TER SPAN TYPICAL SECTION VERTICAL ROOF OPTION SCALE! 1/8• = 1--ff MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. THIS OOCTrEw Is THE FMMTT Q TI0- r An ASSOCIATES. PC. TI[ UMIITIIMIZED qC WPATOIL COPIM M OTHERWIU UK OT THIS DOMID T IS STmICTLT PROggTEG AND ANT ITfIlITIrMHf THIKUPDT MST SC Sk"CT TO LEGAL ACTIO(L 0®g3d�91Iffy,", `°c`s � ' V�s� � � ��' `• �' sus i No 57170 STATE OF Ms item has been electrenkaily signed and seated bKWagne.S. Moore„ Pc using a i igital Signature and (kw Printed copies of this document are not considered signed andseakedl and tYae signature must be verified orr any electronic copies. TUBULAR BUILDING SYSTEMS 40'-0°a30'-O" ENCLOSED BUILDING EXP. B TYPICAL END ELEVATION VERTICAL ROOF SCALE: 1/8' = P-0' 24 GA. LALVoLN ID SETA_ RWF PLELS rASTEWD 41 PLMINS is VMS t3' to GAUGE rURRM CHANUEL CPURLINi _ 48- 'Sc. AAA 40'-0' MA%(WUN RAr TER SPAN TYPICAL SECTION VERTICAL ROOF OPTION SCALE! 1/8• = 1--ff MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. THIS OOCTrEw Is THE FMMTT Q TI0- r An ASSOCIATES. PC. TI[ UMIITIIMIZED qC WPATOIL COPIM M OTHERWIU UK OT THIS DOMID T IS STmICTLT PROggTEG AND ANT ITfIlITIrMHf THIKUPDT MST SC Sk"CT TO LEGAL ACTIO(L 0®g3d�91Iffy,", `°c`s � ' V�s� � � ��' `• �' sus i No 57170 STATE OF Ms item has been electrenkaily signed and seated bKWagne.S. Moore„ Pc using a i igital Signature and (kw Printed copies of this document are not considered signed andseakedl and tYae signature must be verified orr any electronic copies. TUBULAR BUILDING SYSTEMS 40'-0°a30'-O" ENCLOSED BUILDING EXP. B BOX EA`E a } 1 .R i �1R i r• 'I i i i .1 f I tt i f i9 LENGTH VARIES DEFENDING CN [ NUNSER AND SPACING OF RAFTERS s TYPICAL SIDE ELEVATION VERTICAL ROOF/SIDING SCALE: li®' = 1'-0' LENGTH VARIES, DEPENDING ON NUNKR AND SPACtMG CF RAFTERS LS' 1D GAUD£ FURRING CMANNEL FASTENED TO j EACH RAFTER/LEG WITH (2) 012-W.3/4' SOr SPACED 4 4IJT MORE THAN 4V Q.C.. fi i 6� SEE NOTES TO 'PACE 3) Fc`R 11A%tHuH !{ SPACING 4 4 TYPICAL FRAMING SECTION VERTICAL RO13F/SIDING OPTION SCALE 1/8' = I'-0" SS' 10 WU€£ FURRING CHANNEE FASTENED TO EACH RAFTER WITH (2) RprTCR 012-14+3/4• SDF SPACED NOT MRE THAN 40' DC. PANEL ATTACHMENT (ALTERNATE FQR VERTICAL RADF PANELS) MOORE AND ASSOCIATES HNEERING AND CONSULTING, INC. Is 4444406111/Fd"! ®� "f S. MO No 57170 E OF o44/ This item- has been efectrogicalky signed and seated by Wayne 5. Moore, PE. using Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic cnpie. . TUBULAR BUILDING SYSTEMS 40'-0"x2o'-0" ENCLOSED BUILDING EXP. B OPTIONAL HEADED 2 1/2x2 1/2-14 GA (TYP.} 2 1/Ex2 1/2-14 GA mi V-13" D.E. (TY° ) 3/16 TYA 3/k6 i HEADER DETAIL FUR OPENINGS 10'-0' < LENGTH UT-G' SCALC- MS I / I MOORE AND ASSOCIATES 13INEERING AND CONSULTING, INC. cma u TIE PROMTT Or $UK MO AT3'fX1ATO. BC TK )RUID 401011111CIM eo"M 0 OTWWM vai or TNla OOpOEnT as 2 1/2x2 1/2-14 GA CTYP 7 3/16 3/116 TYP HEADER DETAIL. FOR OPENINGS LENGTH 90'—V SCALE NTS ®Jf e � Ncl 57170 s � • s r STATE 01F . �: • vva• . This =Tom hag been efecsrcnecalfy signed and seated Ere Wayne S. 0core, FE. using a Vig2at Signature and date, Primed copies of This ducwnent are ncrz considered, signed and sealed and the signature must be vef fled on any electronic copies. TUBULAR BUILDING SYSTEMS 4W-0"x2V-0" ENCLOSED BUILDING EXP. B i ATTACHMENT D ATC LOAD INFORMATION 102019 ATC Hazards by Location A This is a beta release L,, chle new ATC Hazards by Location website. Pleb�,»contact us with feedback. OTC Hazards by Location Search Information Address: 6106 Silver Oak Dr, Fort Pierce, FL 34982, USA Coordinates: 27.3538809,-80.3102098 \1 Timestamp: 2019-01-08T19:23:52.953Z Hazard Type: Wind 'text Results IMRI 10-Yea01 88 mphl MRI25-Year 108 mph MRI 50-Year' 120 mph MRI 100-Year ®132 mph You are in a wind-borne debris region if you are also within 1 mile of the coastal mean high water line. Risk Categoi I ® 148 mph You are in a wind-borne debris region. Risk Category 11 ® 161 mph You are in a wind-borne debris region. Risk Category III ® 172 mph If the structure under consideration is a healthcare facility, you are in a wind-borne debris region. If other occupancy, use the Risk Category 11 basic wind speed contours to determine if you are in a wind-borne debris region. Risk Categorjy IV ® 182 mph You are in a wind-borne debris region CE 7-10 MRI 10-Year 88 mph MR125-Year 108 mph MRI 50-Year 120 mph https://hazards.atcouncil.org/#/wind?address=6106%20Silver%20Oak%20Dr%2C%20Fort%20Pierce%2C%20FL%2034982%2C%20USA&lat=27.353... 1 /2 178/2019 ATC Hazards by Location MRI 100-Year You are in a wind-borne debris region if you are also within 1 mile of the coastal mean high water line. Risk Category I You are in alwind-borne debris region. Risk Category II You are in a wind-borne debris region. Risk Category III -IV If the struct�re under consideration is a healthcare facility, you are in speed contours to determine if you are in a wind-borne debris region. ANGE 7-05 i ASCE 7-05 !Mind Speed You are in aiwind-borne debris region. A 132 mph A 148 mph A 161 mph A 172 mph a wind-borne debris region. If other occupancy, use the Risk Category 11 basic wind A 141 mph The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process. Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Disclaimer , Hazard loads ate interpolated from data provided in ASCE 7 and rounded up to the nearest whole integer. Per ASCE 7, islands and coastal areas outside the last contour should use the last wind speed contour of the coastal area — in some cases, this website will extrapolate past the last wind speed contour and therefore, provide a wind speed that is slightly higher. NOTE: For queries near wind-borne debris region boundaries, the resulting determination is sensitive to rounding which may affect whether or not it is considered to be within a wind-borne debris region. While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in the report should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals ininterpreting and applying the results of the report provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation fo� the building site described by latitude/longitude location in the report. https:Hhazards.aicauncii.org/#/wind?address=6106%2OSilver%200ak%2ODr%2C%2OFort%2OPierce°/a2C%20FL%2034982°/a2C%20USA&Iat=27.353... 2/2 '1/8/2019 ATC Hazards by Location ® This is a beta release cat` the new ATC Hazards by Location website. Pled contact us with feedback. Xc i Hazards by Location Search Information Address: 6106 Silver Oak Dr, Fort Pierce, FL 34982, USA Coordinates: 27.3538809,-80.3102098 Timestamp: 2019-01-08T19:24:20.207Z Hazard Type: Snow Text Results Ground Snow Load 0 Ib/sgft ASCE 7-05 Ground Snow Load 0 Ib/sqft The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process. Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Disclaimer Hazard loads a re interpolated from data provided in ASCE 7 and rounded up to the nearest whole integer. While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in the report should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals ininterprating and applying the results of the report provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the report. https:llhazards.atcouncil. org/#/snow?address=6106%2OSilver%200ak%2ODr%2C%2OFort%2OPierce%2C`/`20FL%2034982%2C%20 USA&Iat=27.35... 1 /1 138/2019 ATC Hazards by, Location , i Y ® This is a beta release ur-(ne new ATC Hazards by Location website. Ple& ,contact us with feedback. ATC Hazards by Location Search Information Address: 6106 Silver Oak Dr, Fort Pierce, FL 34982, USA Coordinates: 27.3538809,-80.3102098 Timestamp: 2019-01-08T19:24:46.238Z Hazard Type: Seismic i Reference Document: ASCE7-10 Risk Category:; I Site Class: D Report Title: TBS- Chibas Building Map Results MCER Horizontal Response Spectrum sa(g) 0.08 0.06 0.04 0.02 0.00 0 2 4 6 Text Results 8 Design Horizontal Response Spectrum Sa(a) 0.05 0.04 0.03 0.02 0.01 0.00 Period (s) 0 2 4 6 8 Period (s) Basic Parameters Name Value Description Ss 0.055 MCER ground motion (period=0.2s) S1 0.028 MCER ground motion (period=1.Os) SMs 0.088 Site -modified spectral acceleration value SM1 0.068 Site -modified spectral acceleration value https.//hazards.atcou ncii.org/#/seismic?address=6106%2OSilver%200ak%2ODr%2C%2OFort%2OPierce%2C%20FL%2034982°/`2C%20USA&Iat=27. 1/2 118/2019 ATC Hazards by Location SDS 0.059 � 1 1 l i'ieric seismic design value at 0.2s SA - SDt 0.046 Numeric seismic design value at 1.0s SA Additional Information Name Value Description SDC A Seismic design category Fa 1.6 Site amplification factor at 0.2s F, 2.4 Site amplification factor at 1.0s PGA 0.026 MCEG peak ground acceleration FPGA 1.6 Site amplification factor at PGA PGAM 0.042 Site modified peak ground acceleration TL 8 Long -period transition period (s) SsRT 0.055 Probabilistic risk -targeted ground motion (0.2s) f SsUH 0.061 Factored uniform -hazard spectral acceleration (2% probability of exceedance in 50 years) SsD 1.5 Factored deterministic acceleration value (0.2s) S1 RT 0.028 Probabilistic risk -targeted ground motion (1.0s) S1 UH 0.034 Factored uniform -hazard spectral acceleration (2% probability of exceedance in 50 years) 31D 0.6 Factored deterministic acceleration value (1.0s) PGAd 0.5 Factored deterministic acceleration value (PGA) i The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process. Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Disclaimer Hazard loads, are provided by the United States Geological Survey Seismic Design Web Services. While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in the report should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitabjlity and applicability by engineers or other licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation fori the building site described by latitude/longitude location in the report. https:llhazards.atcouncii.org/#/seismic?address=6106%20Silver°/a20Oak%20Dr%2C%20Fort%20Pierce%2C%20FL%2034982%2C%20USA&Iat=27.... 2/2