Loading...
HomeMy WebLinkAboutREVISION - FORMBOARD SURVEY,Jr n.o• t iae• , w.w 27P no ID M II I$o� QIO N Z i RR no ID SaseStreet Center line LEGAL DESCRIPTION i e ano zu, CHOCK ► d, IiVUiAIV KiVt K L D IA ► tJ WWI 31A, accora►ng to the rlat tnereot, as recorded in Plat Book 10, Page 57, Public Records of St. Lucie County, Florida. Flood Zone Data derived by scaling methods of the official FEMA Maps and limited to the accuracy of such maps. Flood Zone: X Community #: 120285, Panel 1. 0281 Suffix: J, Dot . Q12,, PREPARED FOR: Security America Mortgage, inc., its successors and/or assigns, as their interest may appear Ferraro Law Group, PL Old Republic National Title Insurance Company Gui Philipe Chibas and Patricia Ann Chibas Prepared By: Regina C. Kamer, PSM14363 Kamer Surveying, Inc. LB#7357 Prepared For: G UI PHILIPE CHIBAS & PATRICIA ANN CHIBAS LEGEND CIE - Covered Entry CAC - Concrete Pad with Air Conditioning CBS - Concrete Block Structure CUP - Corrugated Metal Pipe Conc. - Concrete CPE - Concrete Pad with Pool Equipment C1v - Cable TV Box Ll - Elevation FFE - Finished Roor Elevation GV - Water Gate valve HYD - Fire Hydrant O/L - Overhead Utility tine PP - Power Pole WPP - Wood Power Pole TCB - Telephone Communications Box SSMH - Sanitary Sewer Manhole UB -utility Box WU - Water Meter SURVEYOR'S REPORT 1 This Survey shall not be valid unless sealed with an embossed Surveyor's Seal 2 No underground improvements have been located as part of this Survey. 3 The last field date of this Survey was: 5.24.17 Update 11.26.18 4 This Survey was prepared using the Plat of Record only. No other documents were provided and no search of the public records was performed by this office. 5 The Survey shown hereon meets the requirement for field accuracy in a suburban area as set forth by the Minimum Technical Standards (5J— 1 7.050-052FAC). _ 6 By acceptance of this survey al! parties agree that the signing surveyor's liability is limited to the amount paid for said Survey. 7 Unless other wise noted all bearing and distances are in accordance with the record plat and have been verified by field measurements. See map for bearing base. 8 Parcel/Lot line locations have been based on found survey control along the center line of Silver Oaks Dr. 9 LEFT BLANK. 10 The Legal Description shown hereon was provided by the client and/or his/her representatives. 11 No ownership of fence lines has been determined os part of this Survey. 12 Off set calls to found survey control are relative to the nearest property corner, intersection of lines, point of curvatures (PC), point of reverse curvatures (PRC)or other identifiable point. 13 Compliance with local zoning requirements and or with requirements set forth by other State, Public, and/or Private entities has not been verified as part of this Survey. 14 Elevations shown hereon are assumed I F. I FCM - Found 4 W Concrete Monument RP - Found J' Iron Pipe RPC - Found1 iron Pipe with Cap 'RLS2035' RR - Found 15 Iron Rod , RRC - Found 15 Iron Rod with Cap IM43' ; SIRC - Set 15 Iron Rod with Cop U17357' i FIPC - Found 1/2' iron Pipe with Cap FM - Found Mo Nail ' FMD - Found jag Nail with Disk FN - Found Nail FNIT - Found Nail with Tin Tab SNIT - Found Nail with Tin Tab FPK - Found PK Nail FPKD - Found PK Nail with Disk i FRRS - Found Rail Road Spike /CO - In Pavement Cut Out KARNER SURVEYING, INC. RESIDENTIAL & COMMERCIAL SURVEYING SERVICES 2740 SW Martin Downs Blvd. 333 Palm City, Florida 34990 PHONE. 1-772-288 7206 FAX: 1-772-223 8181 www.kamersurveyinginc.com E—mail kamer®comcast.net ti-1 N 36.0' 22.6' N One Story Residence 6106 Silver Oak Dr. Reference Bench Mark — Finis a T15-oi--ET-1-0070�— — 1.0' 1.2' O 1 2' a? 8.05' 7.3' 1.2• to 1.2' M ►� 36.6' I ,/ ; / SCANNVEp BY St Lucie Coun �- 5.8' Detail at 1'--20' Sheet Title+ Boundary Survey Srni��,-�, Bate, Brom By, Fleld Boob a4DD-1 LL Job Na. CADD FRe, 0901-150 Sheet No., 1 of 1 Fite No. Proj.lndionRiverEstates/1ndRivEst6-19-19UD