HomeMy WebLinkAboutPRODUCT APPROVAL - ROOF DECK� t f
41'iZJell-i,Q Monad bUilaing Coae Unlina.
BCIS florite Cog rn User Registration- 1 Hot Toples Submit Surcharge scats &Fac& ( pei1r167tfo11S F8C Staff i Scl§ site llaq 11nks 1 Search
db,.
Product Approval
•' 115ER 'pubffrwir'
�. prododAoprofial$tonn.> Prndnet'ar Aanikat(nnSPin•h > �Pnilcannn LIsE> Application Detail
FL FL6596 R5'
SCANNED
Appflcatfon Type Revision Cgdev4sion 201j BY
ApRlicatfon $faEus Approved St Lucie County
I
Comments
Archived
I
PCoduct Man ufacEtirer Carolina Carports,Inc.
Add6FssCBhonejEinaiF 187- Cardinal Ridge Trail,
Dobson,;NC 27017
(336)367=6400
FWaIld8dn@yahpo.coin
Authottized Signature robert cope
jason.c@ carolinacarparts,com
Tecfinical Representative Jason Cope
Address/.Phone%Emali M Cardinal Ridge Trali-
Dobson; NC 27017
.(800) 670=4262 Ext2037
Xq'n.c@ccihq:biz
Quality Assurance Representative
Address/Phone/Email
Category Structural Components
Subcategory Roof Deck
I
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional ;t ngine&
. Evaluation Report - Hardcopy Received
Florida. Engineer or Architect Name who developed Terrence E. Wolfe
the Evaluation Report
Florida. License PE-44923
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration pate 04/05/2627
Validated By Brian Jaks, RE,
Validation Checklist - Ha rdcopy Received
I
Certificate of Independence 1-6596 R5 COI Letter of Certlfication odf
Referenced Standard and Year (of Standard) Standard
Year
ASTM E 1'S92 nos
FM 4471 1992
Equivalence of product Standards
Certified By
Sections from the Code
I
https:/Iwww.fioridabuilding.org/pr/pr app dU.aspx7param=wGEVXQwtDglLgaglWlPgdmvgLTOCyKesgsq%2fzxULibg%aid 1/2
Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted
08/15/2017
Bate. Validated'
08//02017
Nate Pending FBC •Approval
t78/2Z%2017
Date Approved
IdY,1012017
Sitmm iry & Praduc€c
Number or Name
Description.
ffF"Mddei,
AG Panel
26 Ga. AG Roof lyanel over• aPerrfrarriing
Installation instse
inHVHZ: No•
FC6S9d R5 IF_-26"Ga. RG Roof Panel secured pdfse
outside HVHZ( Yes
Verified: py.;Terrence EiW.oife, P.E. 44923
p act ResiStanE: N/A
De91gn Pressure. +57 3 2 5
Created by irldependent'1•hfrd. Party: -Yes
.
psf/ psf
Other See. Evatuatldn Report for Gatious design pressuress:
Eva)uatf -Report`s
FC6596, RS' AE' .26 Ga, AG Rdof•Panel Secured.odf'
Instati peFinanufacturer sdetails, Not far use In HVHZ Zones,
Created by. Independent"Third Party: Yes
6595;Z
AG.Fine
Z3 Ga. AG Roaf Pane{ over.open frartt(agi
,[7,i. — of llsel
Instaliat)on InstnPctions
Npproved for. use {n HVHZ.'No
Approved; tot use oatslde HVHZd Yes
FC6596 R5 II'- Z9 Ga 4G SEructtiraf R6df'Panel NdN' HVH7.
Me: cured:odf
Impact Resistant: N/A
Design Pressure +41 6
Verified fay .Terrence E, Woltdi PA: 44923
Created Yes
psf/-57.3 psf
OtFter See EGa{uatidn Report fdrvaHous design pressures.
by IndependentTh rd.P,arty:
EJaluaton Report`s
Install per Inanufacturei-S details. Not for use in HVH2 Zones.
'FC6596. RS,Alt 29 Ga, AG§troctura{ RaaFPariel NON HVHZ
secured,pil
'Created.by Iiidepenilent-Th(rd;paelV; Yes'
Contact Us :: 2601 Qlilr Siona Hoad.'hllahossce FL 32399 Phone: 650.46MOZ4 .
The State -of Florida Is an'ANEEg;employer. SppyLlght 7.007-2033 StataofAa}Ida.: PrlvaN Statement : t Aecesslblllty St4tem2nt :; RSfund5tatement
under Florida. Lire, email addresses are public rdoards. If you.do dot want your e•mall'address released in iesponseto a public-recards request, do noiisend electronic
Mali to this entlty'Instead, contact the Office by phone or by.tradluonal'moil.•(( you have any questions, please contact 050.407.139S. •pursuant to Section,
455,27S(1); Florida statute;, effective deteher 1i,2012, licensees licensed under Chapter 455,,F,5, mustprovidq theoepartrnehtWith an email address I( they have
one. `fhc emalls provided maybe used, for.o(OcWI cammunl[atlon with the licensee. Hmvever. email addresseaam public record. If you do not wish to supply a. personal
address, please'provlda,the Department with arkmall address which ran ba made available to the,publlc-To determine If you are a licensee. under Chapter 455; FS.,
please click here. ,
Prqduet Approval.AccepM:
W 55A fCA:I M
Credit Card
I
https./Av.floridabultding.org/pr/prl_app dtt;aspxTparam=wGEV . QwtDgtLgagtWlPgdmv9LTOCyKesqsq%2fzxUUbg%3d 2/2
Fd"Cc,Er�gi7.:destifig Inc.Iny
IipinbICXX 77 33 8
Product;uat -
g�qj _ bon Moort.
CAROLINA CARPQRTS, INC.
2$ 6a. A6 Roof.Pahel gmer-operas framing
Florida. Product Appravat #"65q6A ks
Ffori4a'66ildiR' bdiizoll
g qq - - -
Per Rule 6143264
WNW.-' f-'!D
categ.o.r,y.-.Struct'ura[,Cb-ifip'ofients
Su6i:atb9d6- Roof Deck
NON HV HZ
Product Wnufactdkeir:
Carolina Carports, Inc.
187 CardinalAidge trail
Ddbson,PC.27017
Engineer Evaluator:
TerrenceiE.Wcil P;E. # 44923
Florida Evaluation MUM: 1920
Validatbr
Brian JaRs RE. ti70159
Contents:
Evaluation Report Pages 1- 4
E
.,"I CENS
STATE OF
gum ;WAIL
FL# 6596a R5 I r I I I
August 14, 2017
Force EtIv & Testing Nc.-
22-31,012M
UmpliahceStateMent!
The pe6dud as d6s6r!U4j.!h this tepoft has demonstrated compliance With the
Florida 66ilding toicle 2017 04. 1,, 1504.
Peoduct Efestripflarl:
AG Roof Panel, 26 Ga. Steel, 3.V Wide, through fastaried, structural roof-pahel.
Structural Application:
Maiterfall/Standards:
Material: 26Ga. Sti!i2li;ASTMA7kbrASTM>A653(�56cdnformin9 toFlodda
13uifdirig"-Cd'd6 2l)"I 7*'S-dctfon 150A.31. 60tidrfal - parintifnishl.
die 1, 5tmih.gtfi; Mln.'90,0,ksi
to(rrdsibffi-Reskt6rice: Panel Material 9fiall cbmp'IyWitKkoridbi guildingtod4
Panel Qimiensro*):
Thickness: 0. . 0 - I . 8 - 5 min. orderthickness
Wiclih, 36- maximum coverage
Rib Height: YV malor'rib at 9! :O.It.
Pbne[ -Rollformery MRS : Metal
Panel Fatfdner-.
#1244 x W"HWH S0#3 With Qir (16rhm), diameter sealing Waghihi; ci.i appri3v6d
equal..
CofrdsJon Resisitance: PO Flori-da'Building Cade 2017-,-Sectidri 1507.4;4.
SUbstratt, Description
Minimum 144ai (Grade 50) Steel tube framing or Minimum 18 Ga. (Grade 50
Steel hat chariftel See -table A f6r steef gabge. Framing must be
designed in accordance w/ Florida -BuildfingCode 2017.
Allowable DesflgriPressures:
Max1f4brn Design Pressure--
-599pif
G2.5psf
e-83.3,psf
446.9 Psf
+57.30 - if
Panel Fastener Pattern:
2-1-24
2-1-24
24-2-1
.PanefSpnn-
-W O.C.
4' -WO.C.
4'-G".O.C.
51-01 O.C.
4'-0' C.C.
Substrate,
Min.-14 Ga.
Steel Flaming.
Min. .18 Ga, Steel
Framing
Min 14 Ga. Steel
Framing
Min. 18'Ga.
Steel Framing
Min. 18, Ga.
Steel Framing
FL# 6596.1 R5
%
STATEOF Z
CA.
0"
OIL,
Cx)& "N
fum
August 14,2017
u
Fotce Erigineezing &,Testiag:Ii►c.
19330Itambi- addDrivc.
ilumbf ,TX77338'
Code Compliance:
The product described herein has demonstrated compliance Ah.
the Florida Buif BingCode 2017, Section 1504.3.2,15041.
Evaluation Repofiscope:
The prod'uctevaluation fs limited to compliance with the.structuraf.:Wind load
requirements of theftorida.Building'Code 20111 as'ref ates fe Rule 61G20-3.
Perf6rmance,Standards:
The product described herein has demonstrated, compfiance.with:
a 'ASTIVI E'2592.05:(2012)Test method far structural performance of
sheet metal roof:arid siding systefns.by uniform staticak,pressure
difference;
■ FM 4,471-92-FoofTraffic Re`sistance.Test
Reference: Data:
1. ASTM E 1592•05'Test
Force Engineerng & Testfng,.lnc. (F9G Organizatlao;llTSt 5328)
Report No�:183'.Q�63T-16A-E
Z: FM. 447.1-10,.Section 4.4 Foot TraME Resistance Test
Force Engineering &.Testing, Inc. (FBC Oi ganization #TST 5328)
Report No: "183=0109T=12; & 183-0I42T 15
3. Certificate of independence
By T2rrence E. Woife; P.E: (No. 44923) Ca Force Engineering & Testing; Ind.
(FBC Organization 0 ANE ID' .1920)
Test standard Equivalency:
The ASTM E 1592-05 test standard is equivalent to theAST.M'E 1592-05 (2012)
teststandard:
The FM;4411-10, Foot Traffic Resistance teststandard is equivalent to
FM 4471-92.
Quality Assurance Entity:
The manufacturer has established compliance of roof panel products in
accordance with the, Florida Building Code and Rule 61G20-3.005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimurn1tope Range:
Minimum Slope shall comply with Florida Building.Code 2017, including Section
1507.4.2 and`in accordance with Manufacturers recommendations. For slopes
less than 3:12, lap sealant must beused in the panel side laps..
Installation:
Install per manufacturer's recommended details.
E , E
mot. ��.c
��• STATE OF ;ate
'�p�`• LORI�A
sar�nm. �� FS • . �. ��'
,,��ON
sum
FL# 6596.1 R5
August 14.2017
I
Force Engineering &:Testing Inc.
19b6 iia'mblcwooJ Drinc
HuitiWITX, 77339°
Insulation: Manufacturer's approved produet (Optidrial)
Roof Panel.Fiie Classification: Fire classification is not partofthis acceptance:
Shear Dtaphi:aigen: Shear diaphragm values -outside the scope.ofthis repdit:
Oesign Procedure: Osed on the dirnension.9 of the structure, apprgpriafe wind toads are
deteitniried using Chapte f 16 of Elie Florida 8uildin� Code.3617 far we
cladding
wind loads These componentwiod,foddsforjoofdaddingare-compared toih6
allowable pressure•listed.afipve. The.desigrti professionaishatf setect_the
approp`r'raie erection details to:reference irk his drawings for proper fastener
'attac6mer ttahls structure and analyze the;pane) fasten6fsforspullo6tand'
pullovec Support framing must be in compliance vMh Florida Building Code 2017
Chapter 22 for steel and•Chaptee 16:for structural loading.
IFliiltll
CENOk
S.F:,h�'
NO.499 r n
'a STA-M Or
iy
'0�. RLOR'j-D?` 4's
FL# 6596.1 R5
August 14, 2017
LIOZ. 'tI MOW
,p��doouaaarr
avis
:gym
EZEt�N'oN `
NBO
queer➢
�Fli w jo oja�g
(9Nwa Bo-J V avi 33$)
'� N5Y16 Jt717g3S b3131tV10 (WW91) •B/S /ES f(JOS H98 :i'/C x �t-ZLji� �Na'mad V14D- Vh -13 15 09Y d), bj. ,V ':NIVY aO
9N6Y1'�i "13NNYHD�1tlH '133i5 (OS aUVIl�) V9 El 'NIIY
a3 N 1—Z—FZ 113WISVI-13M
.