Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PRODUCT APPROVAL - UNDERLAYMENTS
Plorida Building Code Online BCIS Home I Log In I User Registration Hot T Product Approval F eco• p,au� umr Suhmit charge I is s L Page 1. of 2 ti -- Kh n;7-- : r"IH ;�aub14iie,'meP:«p Product Approval Menu > Product or Application Search > ADalication List > Application Detail FL # FL2894-R7 qC-epA. f ©�-'�,(0 5/^�,� Application Type Revision 1 f�— Code Version 2017 ST. LUCIE COUNTY BUILDING DIY;SION Application Status Approved REVIEWED FOR COMPLIANCE e n A z A Comments Archived Product Manufacturer CONCEALED44'48T. `,,AEFOORiARTACHIV.Ei4TS ARE THE RESPONSIBILITY OF THE CONTRACTOR OR RECORD Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Testing Lab Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) n4r-s, . E�9_I .NS A6rliti ALL C�IR®PO` ED t 40r K "ARE SLIBJCCT TO ANY CORRECTIONS REQIJIREI I BY FIELD INSPIEC�i O lVeoducct Standards MAY BE NECESSARY II CODES. COMPLY WITH ALL AP4'� v Lim I C - " - 13 PLANS AND PERMIT MUST BE KEPT N OB SITE OR NO INSPECTION(S) WILL E ADE G.A.P. Roofing 4444 Hunt Street pryor, OK 74361 (386) 288-4583 dave.swaroopgap@gmail.com SCANNED Dave Swaroop BY dave.swaroopgap@gmail.com St Lucie County Dave Swaroop P.O. Box 828 Jasper, FL 32052 (386) 288-4583 dave.swaroopgap@gmail.com Roofing Underlayments Test Report PRI Construction Materials Technologies, LLC Keystone Certifications, Inc. 12/31/2023 Locke Bowden P.E. M Validation Checklist - Hardcopy Received FL2894 R7 COI PRi CMT Certificate of Independence - 2014-08-29 pdf Standard Year ASTM D 226 2009 ASTM D 4601 Type II 2004 ASTM D 4869 2016 ASTM D 6380 Class M Type II 2003 TAS 110 2000 Approved Testing Lab FL2894 R7 Eauiv GAPR-016-02-01 FBC 2017 Later - FBC FL2894.odf I http://W,iw,floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDqukmQHM%2b... I 6/14/2018 ' Florida Building Code Online Product Approval Method Method 1 Option B Date Submitted 04/19/2018 Date Validated 05/01/2018 Date Pending FBC Approval 05/0212018 Date Approved 06/12/2018 Page 2 of 2 Summary of Proaucts FL # Model, Number or Name Description 2894.1 Glass Base Sheet ASTM 04601 Glass Base Sheet ASTM D4601 Type lI Type II Limits of Use Approved for use in HVHZ: No Installation Instructions FL2894 R7 II TR G2 4601 Type iI.Ddf Approved for use outside HVHZ: Yes Verified By: PRI Construction Materials Technologies, LLC Impact Resistant: N/A Test Reports II-adf Design Pressure: N/A Other: Fiberglass base sheet is applied over Flat roofing FL2894 R7 TR G2 4603Type FL2894 R7 TR GAPR-016-02-01 FBC 2017 Letter - FBC FL2.894.Ddf deck. To be used with approved systems. 2B94,2 Tile Underlayment ASTM D 6380 Organic Underlayment used under Concrete Tiles Limits of Use Installation Instructions installation,Ddf Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL2894 R7 II Tile Underlayment Verified By: PRI Construction Materials Technologies, LLC Impact Resistant: N/A Design Pressure: N/A Test Reports FL2894 R7 TR GAPR-016-02-01 FBC 2017 Letter - FBC FL2894.1)-df FL2894 R7 TR Tile Underlayment Oualitv.Ddf Other: Tile Underlayment ASTM D6380 Organic Underlayment used under Concrete Tiles. This product shall be used as a component of approved roof assembly. Install in accordance with 1507.3.3 Type 1#3'0 Fe� i:xr y #30 Saturated Felt Paper, ASTM D 4869 Type II Limits of Use Approved for use in HVHZ: Installation Instructions FL 894 R7 11 Felt Installation Instructions od f Approved for use outside HVHZ: Yes Verified B PRI Construction Materials Technologies, LLC Y� Impact Resistant: N/A Test Reports FL2894 R7 TR 4869Aooroval Ddf Design Pressure: N/A Other: Subroofing underlayment to be installed under FL2894 R7 TR GAPR-016-92-01 FBC 2017 Letter FBC FL2894.Ddf organic, asphalt, metal, slate, wood or fiberglass shingle. Install in accordance with 1507.1.1 2894.4 Type II, No. 30 Type II, No. 30 Limits of Use Installation Instructions FL2894 R7 II Installation Instructions Ddf Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Verified By: PRI Construction Materials Technologies, LLC Impact Resistant: N/A Design Pressure: N/A Test Reports FL2894 R7 TR G8PR-027-02-01 Report - ASTM D 226 30_Ddf Other: Subroofing underlayment to be Installed under organic, asphalt, metal, slate, wood and fiberglass shingles. Install in accordance with 1507.1.1 Back Next Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1221 The State of Florida is an AA/EEO employer. C^^vrioht 2007-2013 State of Florida.:: Privacy Statement :: Sn' sibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455,275(S), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address Fswhich can be dick made available to the public. To determine If you are a licensee under Chapter plea Product Approval Accepts: ® ®® Credit Cyr I http://www.floridabiiilding.org/pr/pr_app_dtl.aspa?param=wGEVXQwtDgtikmQHMv /%2b... 6/14/2018 G.A.P. ROOFING, INC.'S INSTRUCTIONS FOR INSTALLATION OF ASPHALT FELT ROOFING PAPER I. GENERAL INSTRUCTIONS G.A.P. Roofing, Inc.'s ("G.A.P.") asphalt felt roofing paper is used both as a primary roof covering and as a flashing material. , When the maximum service life is an important consideration, use the concealed nail method of application. As a primary roof covering, the felt paper can be used on slopes down to one inch per foot. If the exposed nail method of application is used, the minimum required slope is two inches per foot. The felt paper is applied either parallel to the eaves or parallel to the rakes. The type of nail shall fit the application and have a length sufficient to penetrate'/4 inch into the deck or through the deck panel. Before applying the felt paper, prepare the deck and install the necessary flashing. Valleys will be the open type so follow the appropriate valley flashing procedures. Because the felt paper is applied with a certain amount of top and side lapping, proper sealing of the laps is critical. To seal the laps, use lap cement which conforms to ASTM D-3019 or D-4586. H. APPLICATION PARALLEL TO THE RAKE • Concealed Nail Method — With this method, the felt paper is applied vertically from the eaves up. Lay the felt paper out and let them wann from the sun until they lie smoothly on a flat surface. if you nail the sheets before they have time to relax, wrinkling may occur. Edge Strips — Place 9-inch-wide strips of felt paper along the eaves and rakes. Placement and nailing of theses strips is identical to the description found in the concealed nail method for application parallel to the eaves. First Course — Position the first sheet so it is flush with the edge strips at the rake and. eaves. Fasten the upper edge nails located 1 inch and 5 inches from the top edge of the sheet with the nails spaced 4 inches on center. Carefully lift the first sheet back and cover both edge strips with an even layer of plastic cement. Excessive amounts of plastic cement may cause blistering. Press the sheet firmly into the cement. Work from the top of the sheet down to avoid wrinkling or bubbling. End laps should be a minimum of 6 inches wide. Fasten the length of the end lap with nails 4 inches on center and slightly staggered. Locate the nails so that the next sheet will overlap them a minimum of 1 inch. End laps should be cemented over the full lap area with recommended lap cement. • Top laps should be a minimum of 6 inches wide. Stagger the top laps of adjoining sheets to prevent a buildup where the sheets intersect. End laps should be cemented over the full lap area with the recommended lap cement. Second and Succeeding Courses — Position the second course so that it overlaps the first course at least 6 inches. Fasten the upper edge to the deck, cement the laps and finish installing the sheet in the same manner as the first course. Do not apply nails within 18 inches of the rake until the cement has been applied to the edge strip and the overlying strip has been pressed down. All cement should be applied in a continuous, but not excessive, layer over the full width of the lap. Press the edge of the sheets into the cement until a small bead appears at the -lap. Use a roller to apply uniform pressure over the entire cemented area. III. APPLICATION PARALLEL TO THE EAVES • Concealed Nail Method — When using this method, narrow edging strips are placed along the eaves and rakes before applying the sheets of felt paper. • Edge Strips — Place 9 inch -wide strips of felt paper along the eaves and rakes, positioning them to overhang the deck '/a to 3/8 inch. Fasten the strips with rows of nails located 1 inch and 8 inches from the roof edge and spaced. 4 inches on center in each row. First Course — Position. a full -width strip of felt paper so that its lower edge and ends are flush with the edge strips at the eaves and rakes. Fasten the upper edge with nails 4 inches on center and slightly staggered. Locate the nails so that the next course will overlap them a minimum of 1 inch. Lift the lower edge of the first course and cover the edge strips with cement. In cold weather turn the course back carefully to avoid damaging the roofing material. Press the lower edge and rake the ends of the first course firmly into the cement -covered edge strips. Work from one side of the sheet to the other to avoid wrinkling or bubbling. End laps should be 6 inches wide and cemented over the full lap area with the recommended cement. Nail the underlying sheet in rows 1 inch and 5 inches from the end of the sheet with the nails spaced 4 inches on center and slightly staggered. End laps in succeeding courses must not line up with one another. Second and Succeeding Courses- Position the second course so that it overlaps the first course at least 3 inches. Fasten the upper edge to the deck, cement the laps and finish installing the sheet in the same manner as the first course. Follow the same procedure for each successive course. Do not apply nails within 18 inches of the rake until cement has been applied to the edge strip and the overlying strip has been pressed down. • Hips and Ridges — Trim, butt and nail the sheets as they meet at a hip or ridge. Next, cut 1206 inch strips from the felt paper and bend them lengthwise to lay 6 inches on each side of the joint. Do not bend the strips in cold weather without first warming them. These will be used as shingles to cover the joint, each one overlapping the other by 6 inches. • Start hips at the bottom of the ridges at the end opposite of the direction of the prevailing winds. To guide the installation, snap a chalk line 5-1/2 inches from and parallel to the joint on both sides. Apply asphalt plastic cement evenly over the entire area between the chalk and lines from one side of the joint to the other. Fit the first folded strip over the joint and press it firmly into the cement, driving two nails 5-1/2 inches from the edge of the end that will be lapped. Cover the 6-inch lap on this strip with lap cement, then place the next strip over it. Nail and cement in the same manner as the first strip. Continue the same procedure until the hip or ridge is finished. M 3 CONSTRUCTION MATERIALS TECHNOLOGIES . L�tBCQRAT:CiR,Y'`TEST.�S�l1�.TS Report for: G.A.P. Roofing, Inc. 4444 Hunt Street Pryor, OK 74361 Attention: Christi Mack Product Name(s): GAP ASTM 30 D226 Manufacturer: G.A.P. Roofing, Inc. PRI-CMT Project No.: GAPR-027-02-01 Source: G.A.P. Roofing, Inc. Date Received: Apr. 5, 2018 Dates Tested: Apr. 9 -17, 2018 Purpose: Evaluate GAP ASTM 30 D226 for compliance with the physical properties of ASTM D 226 Asphalt -Saturated Felt Used in Roofing and Waterproofing, Type II. Test Methods: Testing was completed as described in ASTM D 226-09: Standard Specification for Asphalt -Saturated Organic Felt Used in Roofing and Waterproofing. Test methods assigned or referenced include ASTM D 70: Standard Test Method for Density of Semi- solid Bituminous Materials (Pycnometer Method); ASTM D 146: Standard Test Methods for Sampling and Testing Bitumen -Saturated Felts and Woven Fabrics for Roofing and Waterproofing; and ASTM D 6136: Standard Test Method for Kerosine Number of Unsaturated (Dry) Felt by Vacuum Method. Sampling: Product samples were provided by G.A.P. Roofing, Inc. GAPR-027-02.01 The test results, opinions, or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile in any form can be made without the client's permission, This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility nor makes a performance or warranty statement for this material or products and processes containing this material in connection with this report. PRI construction Materials Technologies LLC 6412 Badger Drive Tampa, FL 33610 Tel! B.13-621-5777 Pax: g13-621.5340 e-mail: materialstesting@pricmt.com WebSite:http://wvr++.pricmt.com G.A.P. Roofing, Inc. ASTM D 226 for GAP ASTM 30 D226 Page 2 of 3 Results: ASTM D 226 Requirement Property.. Result Type I Type If � � Y � ty ��, � 4r �ilulrei� �rength eA�,nRate=2in , � Y � h)ens; m@73.4±3.6'F; 1kness; ASTM D 146 @ 73.4±5%RH;.4±3.6°/min Longitudinal (with fiber grain) Transverse (across fiber grain) y 2y'p Pliability [Pass/Fail] 10 specimens; 1" x 8" x thickness; ASTM D 146 %" radius %" radius Cond. 10-15min in water @ 77±1.8°F; Test 90° around Y2" radius in 2s Longitudinal (with fiber grain) Pass s N�aalfUresJ 4y✓. �f..'.l"1=,."�.+;iP'."'a ; iq�i)�t� . 4i4 ,.� 4a .`wti�S fiber Pass n Transverse (across grain) ,xNoatu�es Loss on Heating (weight %) YYr 2 specimens; 12" x 6" x thickness; ASTM Test Cond. 221±5°F for 5h±3min {{ wtf M �• y� 1 "!.' 4 h S d . f T Y W i.^ r a t\' y" }..l�i 1 r L' Y 4 i M1 l•: ty S'.. �"z,L � i.ItllrChV!• P� IY.Q�tJe�' .7 5 aySd`e ! yl. t +� "F`M" ft ,C 1.- ,.i.. ,'�a� r,..• �, � ...�! ra,,,±; } .1!✓.,}„r it ,r ..+r, .r;1r. -.S'�, r.^". ,.f..� S r Width Roll (in) ASTM D 146 of 2 D 146 �.�. Area, min (ft j ASTM : �.,,�,;;r�%��'"„�� •C�'� � D Moisture at Point of Manufacture (%) ASTM 146 As Received' Q A�"��ti .5c€� r Net Mass Saturated Felt (lb/ 100ft2) ASTM D 146 2'?y' ttif''h441w"'+s` r 1y'v '>r of �IMass ASTM D 146 16 2 of Saturant (lb/100ft2) Asµ Desaturated Felt ASTM D 226N. Mass Ratio of Saturant to AAy Saturation Efficiency (%) ASTM D 226 Mass of Desaturated Felt (lb/100ft2) ASTM D 146 10 9 ' fK 5 S ry hq ASTM D 146 6 4 W; t o Ash K ly y nRNI icontinued on Following Page GAPR-027-02-01 The test results, opinions, or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile In any form can be made without the client's permission. This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility nor makes a performance or warranty statement for this material or products and processes containing this material in connection with this report. I PRI construction Materials Technoloeles LLC 6412 Badger Drive Tampa. FL33610 Te1:813.621.5777 Fax:813.621-S8M'1 e-mail: materialsteslin8@prlcmt.com WebS1te:http,.j/www.pricmt.CQm G.A.P. Roofing, Inc. ASTM D 226 for GAP ASTM 30 D226 Page 3 of 3 Perforated Felt (in2) 1 ASTM D 226 Average Venting Area (%) I ASTM D 226 I NA [r�t� {tiRa ' Unrolling @ 50°F and 140°F [Pass/Foil] I ASTM 0 226 I Pass .,�htatt�e�aRva�;;� Note(s): 1- Moisture (As Received) was utilized in lieu of Moisture at Point of Manufacture; NT- Not Tested; NA- Not Applicable Statement of Compliance: The product was tested has demonstrated compliance with the physical requirements of Type II prescribed in ASTM D 1 226-09: Standard Specification for Asphalt -Saturated Organic Felt Used in Roofing and Waterproofing. im : '� ll#ittelSis Issue #i Date Pages Revision Description (if applicable) Original 04/19/2018 3 NA END OF REPORT GAPR-027-02-01 The test results, opinions, or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced except In full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility nor makes a performance or warranty I statement for this material or products and processes containing this material in connection with this report. PRI construction Materials Technologies LLC 6412 Badger Drive Tainpa, FL 33610 Tel: 813-621.5777 Faz. 813.621-5840 e-mail: materialstesting@pricmt.com webSite!http://www.pricmi.com