0'—
-�12"08" REINFORCED FOOTER
PLAN VIEW
2 5" BUILDING FRAMING
2.
RECESS
--- 3- -- --- --- --
DOOR WIDTH
ELEVATION VIEW
BUILDING FRAMING
RECESS
T
75"J I DOOR WIDTH I
ROLL —UP DOOR CONCRETE
SPLASH —GUARD RECESS
4"x3"(2,500 LB.) CONCRETE
WEDGE ANCHOR WITHIN 6"
OF EACH POST.
2" MIN. BASE RAIL A_ft�24" EMBEDMENT MIN.
1 [CAPACITY
�6'--12"CONCRETE FOOTER WITH(2) #5
IMUM SOIL BEARING REBAR ® 6" O.C. CONTINUOUS
2,000 PSF (TYP.) WITH MINIMUM 12" OVERLAP
SPLICE
CONCRETE FOUNDATION/BASE RAIL.
ANCHOR DETAIL
NOTES -
SUB —GRADE SOILS:
—TO BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION R318 AND 1816 OF THE 2017 FLORIDA
BUILDING CODE, 6TH EDITION
CONCRETE:
—MINIMUM 2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS
—ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE DESIGNED TO SLOPE AWAY FROM THE
STRUCTURE
REINFORCING STEEL (REBAR) REQUIREMENTS:
—MINIMUM GRADE 40 STEEL
—REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED:
—THE REBAR IS BENT COLD
—THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED 6—BAR DIAMETERS: AND
—REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT IN CASES WHERE DOWELS NEED
TO BE BENT TO ALIGN WITH A VERTICAL CELL. THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1"
HORIZONTALLY TO 6" VERTICALLY-
-COVER:
—2" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH SOIL OR WEATHER, AND
14" ELSEWHERE. REBAR EMBEDDED IN GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF J" FOR FINE GROUT,
AND 4" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL. REBAR USED IN MASONRY WALLS SHALL HAVE A
MASONRY COVER (INCLUDING GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR
WEATHER, AND 14" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR WEATHER.
GALVANIZATION:
—METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY EXPOSED TO WEATHER SHALL BE
GALVANIZED IN ACCORDANCE WITH ASTM A 153, CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED
DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED.
---- FRAE--------------------------------------------------------- MAW ---------
-6
m
�8/® 0bgj
ST. LUCIE C COUNTY BUILD G D VISI N
REVIEWED FOR COMP_LIA C
REVIEWED BY
DATE
PLANS AND PERMIT MUSt B KEPT ON JOB
SITE OR NO INSPECTIONS WILL BE MADE
ALL MANUFACTURES LAF3LL% Sl43iRl NG
U FACTORS AND SHGC COMPLIANCE
WITH FBC ENERGY CODE MUST
REMAIN ON ALL DOORS AND WINDOWS
UNTIL INSPECTIONS ARE APPROVED
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
0NCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OF RECORD.
--------- TRAW----------
0'-1j
I
I
i
I
FRAMF
OUTI
I
i
I
I
i
-- T
i
I
I
I
I
I
I
I
I
I
I
I
I
FRAML
OUT
I
I
I
I
I
I
I
I
I
I
J
4
—091,
CODE VERSION
FBC 2017 6th Edition, ASCE—
MANUFACTURER
CARPORTS ANYWHERE
BUILDING TYPE
RESIOENML STRUCTURE
— —
CONSTRUCTION —TYPE
---
FIRE PROTECTION
NONE
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCY
R-2
RISK CATEGORY
1
BASIC WIND SPEED
Vr-180mph
EXPOSURE
C
ENCLOSURE
ENCLOSED
INTERNAL PRESSURE COEFFICIENT
+/— 0.18
IMPORTANCE FACTOR
1.15
ROOF DEAD LOAD
tOPSF
ROOF LIVE LOAD
20PSF OR 3001b POINT LOAD
FLOOR DEAD LOAD
IOPSF
'R" RATING OF WALLS, FLOOR, ROOF
N/A
MODULES PER BUILDING
1
HURRICANE PROTECTION USAGE
NO
HURRICANE SHELTER USAGE
NO
SQUARE FOOTAGE
2236 SO. FT.
1 1RE11SED SPACING & FRAMEOUTS I70/22/19I MT8
2 REVISED LENGTH 11 /7/181 MTB
awn By: MTB
Ite: 8/10/18
c Ion
:
3b:1 3 S. Indian River Dr., Ft. Pierce 34982
)del : 431 X 52'W X 16'H
NERni NOTES_
THIS BUILDING IS NOT EXEMPT FROM THE FBC ENERGY
CONSERVATION CODE PER SECTION 1015.22.
ALL STEEL TUBING SHALL BE 50 KSI STEEL
PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY
SET —BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE
THE RESPONSIBILITY OF THE OWNER.
ROOF AND WALL SHEATHING SECURED WITH #12-140"
SELF—DRIWNG SCREWS WITH SEAL WASHERS 0 6" O.C. MAX.
FIELD FRAMING CONNECTIONS SECURED WITH #12-14x3/4"
NDRI SCREWS.
ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED.
CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM
1/2-W, 2,50OLB TENSILE STRENGTH.
14GA. FRAMING IS 2.5'x2.5" TUBE STEEL. NIPPLES ARE
2.25'x2.25" TUBE STEEL
S=
E
i
w_\ 11/7/18
z MattheW T. BOIdWin P.E.
Florida License #64608
Sheet: CA-1 OF 4
- --- -- - _ - - - - - - - -
-e'
1
4art
. . -
- - — - --- - — - -- - - - -- - - - - -
amO
CARPORTSANYWHERE
-
m
CODE INFORMATION
-a•
Y nulk
art
n
art -
CODE VERSION
FBC 2017 6th Edition, ASCE-7-10
MANUFACTURER
CARPORTS ANYWHERE
....._...._.....__
.
.__.._..._.
....._..._...._
... ...... ......._.................
........_
-
. ....... .._
.............
BUILDING TYPE
RESIDENTIALSTRUCTURE
CONSTRUCTION TYPE - -
II-B- --- -
Y
FIRE PROTECTION
NONE
FlRE SUPPRESSION SYSTEM
NONE
� �• � � �• d� _yTa• � � � �• -qb• �
FRONT END WALL
OCCUPANCY
R-2
_.. . ................. _.._.._........_............ _......... __.._..__. __._.._....___._......... ____....... _........ ___.....
RISK CATEGORY
1
BASIC WIND SPEED
Vm-180a,ph
��-
EXPOSURE
C
ENCLOSURE
ENCLOSED
INTERNAL PRESSURE COEFFICIENT
+/- 0.18
IMPORTANCE FACTOR
1.15
ROOF DEAD LOAD
10PSF
ROOF LIVE LOAD
20PSF OR 3001b POINT LOAD
FLOOR DEAD LOAD
1OPSF
`R" RATING OF WALLS, FLOOR, ROOF
N/A
MODULES PER BUILDING
I 1
HURRICANE PROTECTION USAGE
NO
.......................
.
_-._........ _.
... _..... ....... _.................
-..... _
..._............ ...
.._..._........ ........
.......
b
HURRICANE SHELTER USAGE
NO
e
nwfk
an ..........._
SQUARE FOOTAGE
2,236 SQ. FT.
REVISIONS
REV
DESCRIPTON
DATE
BY
1
REVISED SPACING & FRAMEOUTS
10/22/18
MTB
2
REVISED LENGTH
11/7/18
MTB
REM END WALL
'tr
'e
Drawn By: MTB
_.... _..
...... ..._.._
.___
..-._..
..... _.... __
_......__....
Date: 8/ 10/ 18
Lac an:
S. Indian River Dr., Ft. Pierce 34982
odel : 431 X 52'W X 16'H
'
GENERAL NOES_
1. THIS BUILDING IS NOT EXEMPT FROM THE FBC ENERGY
CONSERVATION CODE PER SECTION 1015.22.
2. ALL STEEL TUBING SHALL BE 50 KSI STEEL
3. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY
SEr-BACKS, MD/OR OTHER LOCAL CODE REQUIREMENTS ME
THE RESPONSIBILITY OF THE OWNER.
4. ROOF AND WALL SHEATHING SECURED WITH #12-14x1"
SELF-DRIWNG SCREWS WITH SEAL WASHERS ® 6" O.C. MAX.
5. FIELD FRAMING CONNECTIONS SECURED WITH e12-14x3/4"
SELF-DRIWNG SCREWS.
6. ALL SHOP FRAMING CONNEC IONS ME TO BE ELDED_
7. CONCRETE EXPANSIONS ANCHORS ME TO BE INIMUM
............................
........................._
._.................................._.........-._
........... __......_..
---.......__....._
... _......_...._.._...._.................__
..... _....................
... ...... _...................................
...
Contractor COPY
'•°'
W\
l 1r
J
�7
LC
C
II__L
z
w
qj
W
1/2"x3", Z500LB TENSILE STRENGTH.
8. 14GA.FRAMING IS 2.5"x2.5" TUBE STEEL NIPPLES ME
2.25"x2.25" TUBE STEEL
LEFT SIDE WALL
.
1 1 /7/ 18
Matthew T. Baldwin P.E.
..... _._............
..... _..._............
.._.__.._...........
__.... _....... --'-- ...... ..... .___ ..._................._ _.........._.____._
.......... __._.... _............. .._........ _._....... .-.. _.... - ........ ... .
Pd
!-d
art
uaws
'�"'"'
art
uu+mr
'�`"P °0°"1
aoa
+•-q1•
yy qy , b„M _, _,
RIGHT SIDE WALL
J
cn
Florida License #64608
Sheet: CA-2 OF 4
]1�
b
- T ANY ERE
CODE INFORMATION
CODE VERSION
FBC 2017 6th Edition, ASCE-7-10
MANUFACTURER
CARPORTS ANYWHERE
BUILDING TYPE
RESIDENTIAL STRUCTURE
CONSTRUCTIONTYPE —
it-
9-FIRE PROTECTION
NONE
-o•
FRONT END WALL
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCY
R-2
e
RISK CATEGORY
I
BASIC WIND SPEED
ve-180mph
EXPOSURE
C
ENCLOSURE
ENCLOSED
INTERNAL PRESSURE COEFFICIENT
+/- 0.18
IMPORTANCE FACTOR
1.15
ROOF DEAD LOAD
1aPSF
ROOF LIVE LOAD
20PSF OR 3001b POINT LOAD
FLOOR DEAD LOAD
1OPSF
'R' RATING OF WALLS, FLOOR, ROOF
N/A
MODULES PER BUILDING
1
HURRICANE PROTECTION USAGE
NO
HURRICANE SHELTER USAGE
NO
SQUARE FOOTAGE
2,236 so. FT.
REVISIONS
REV
DESCRIPTON
DATE
BY
I
REVISED SPACING & FRAMEOUTS
10/22/18
MTB
2
REVISED LENGTH
11/7/18
MT8
REAR END WALL
Drawn By: MTB
b
Date: 8/ 10/ 18
IVYL c on:
S. Indian River Dr., Ft. Pierce 34982
Model : 43'L X 52'W X 16'H
GFNFRAI NOTFC
1. THIS BUILDINGIS NOT EXEMPTMTHE C ENERGY
CONSERVATIONCODE PER SECTION1015.22.
2. ALL STEEL TUBING SHALL BE 50 KSI STEEL
3. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY
SET -BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE
THE RESPONSIBILITY OF THE OWNER.
4. ROOF AND WALL SHEATHING SECURED WITH #12-14x1'
SELF-DRILUNG SCREWS WITH SEAL WASHERS ® 6O.C. MAX.
5. FIELD FRAMING CONNECTIONS SECURED WITH a12-14x3/4"
SELF-DRIWNG SCREWS.
BALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED.
7. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM
1/2'x3', Z50OL13 TENSILE STRENGTH.
Contractor Copy
Cn
\LiJ
Z
w
W
8. 14GA. FRAMING IS 2.5'x2.5' TUBE STEEL NIPPLES ARE
2.Wx225' TUBE STEEL
LEFT SIDE WALL
1 1 /7/ 18
MottheW T. BoldWin P.E.
Florida License #664608
b
---------------------
RIGHT SIDE WALL
Q
(n
H
Sheet: CA-3 01 4
MINIMUM 6' TS NIPPLE. NIPPLE
MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH tT
SECURED TO WALL POST WITH (4))(12-14x4' SELF —DRILLING SCREWS
(4))j12-14 SELF—DRILUG SCRE115
{V" IPPLE TO NIPPLE TO A" 2"x2'x2' 16 GA ANGLE CUP SECURED
845E RAIL BASE RAIL WITH (4) #12-144" SELF—DRIWNC
SCREWS 2'x2"x2' 16 GA ANGLE CUP SECURED
WITH (4) 012-144" SELF—DRIWNC
Ll:i SCREWS
INTERMEDIATE POST TO
POST TO BASE RAIL END POST TO BASE RAIL HEADER/BASE RAIL/OR
"0_ ECTION C6NI�ECTIOf�T-- — — -- — WINDO —RAI-L DET 1L--
2"x2"x2" 16 GA. ANGLE CLIP SECURED
WITH (4) #12-14xj" SELF —DRILLING
SCREWS
2"X2"x2" 16 GA ANGLE CUP
SECURED WITH (4) 012-144"
SELF—DRILUNG SCREWS
OR DOUBLETS HEADER
MINIMUM 6" TS NIPPLE NIPPLE
SECURED TO WALL POST WITH
(4)812-14,4' SELF—DRILUNG SCREWS
OR DOUBLETS HEADER
HEADER CONNECTION pft
NECTION I HEADER CONNECTION DETAIL
r—VARIES 26 GAUGE ROOF SHEATHING SECURED
-F 2"x2"x2" 16 GA. ANGLE CLIP
SECURED WITH (4) #12-1414"
SELF —DRILLING SCREWS
NON—STRUCTURAL HEADER OR
WINDOW RAIL TO POST DETAIL
d12-14x3" SELF —DRILLING
SCREWS O 10' O.C. MAX., 3'
MAX. FROM CORNERS
HORIZONTALLY/ 4" MAX. FROM
CORNERS VERTICALLY
INTERIOR p
EXTERIOR
1
DOOR FRAME TO POST
CONNECTION
INSTALL PER MANUFACTURERS INSTRUCTIONS
#14x1" SELF —DRILLING
SCREWS m 6" O.C. MAX. &
6' MAX. FROM CORNERS
ROLL —UP DOOR TO
POST CONNECTION
DESIGN PRESSURES
- 180 Mph
ROOF
+27.8/-62.5
WALLS
+32.5/-29.2
DOORS
+32.5/-29.2
WINDOWS
+32.5/-29.2
1
2
3
4
5
ZONE
+ 17.3
-24.9
+20.4
-48.3
+27.8
-62.5
+32.5
-29.2
+30.9
-26.7
STD. MAX. SPACING
3"
STD. MAX. SPACING Pgrl
VARIES
SIDE WALL ROLL —UP
DOOR HEADER DETAIL
WITH (1)#12-14m SELF —DRILLING
SCREWS ® 6" O.C. (9' O.C. MAX)
1' 16 GAUGE FURRING CHANNEL 48"
O.C. MAX. SECURED WITH (2)#12-14x1'
SELF—DRIWNG SCREWS TO EACH RAFTER.
ROOF PANEL CONNECTION
VERTICAL SHEATHING OPTION
NIPPLE TO
RAFTER
MINIMUM 6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH
(4)�12-144— SELF —DRILLING SCREWS
POST TO TRUSS
CONNECTION
26 GA RIDGE CAP
r6"MAX
1-611
26 GA. ROOF
SHEATHING
26 GAUGE ROOF SHEATHING SECURED ECURED TO
—WITH (1)Al2-14,d' SELF—DRIWNGSCREWS O 9" D.C. MAX. )#12-14xi'
EWS
ROOF RIDGE CAP 60' TRUSS RAFTER TO
REINFORCEMENT POST CONNECTION DETAIL
CODE VERSION
FBC6C 2017 fi!h Edition, ASCE—;
CARPORTS ANYWHERE
®MANUFACTURER
BUILDING TYPE
RESIDENTIAL STRUCTURE
CONSTRUCTION TYPE
II—B
PROTECTION
NONE
uFIRE
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCY
R-2
ALLOWABLE NUMBER OF STORIES
1
LU
BASIC WIND SPEED
Ym 180mph
EXPOSURE
C
ENCLOSURE
ENCLOSED
INTERNAL PRESSURE COEFFICIENT
+/— 0.18
IMPORTANCE FACTOR
1.15
U.
ROOF DEAD LOAD
1OPSF
ROOF LIVE LOAD
20PSF OR 3001b POINT LOAD
FLOOR DEAD LOAD
IOPSF
"R" RATING OF WALLS, FLOOR, ROOF
N/A
MODULES PER BUILDING
1
HURRICANE PROTECTION USAGE
NO
HURRICANE SHELTER USAGE
No
SQUARE FOOTAGE
2, 188 SQ. FT_
TRUSSED RAFTER
CONNECTION DETAIL
APPROVED PRODUCTS
APPROVAL NO.
ROOF SHEATHING
Carports Anywhere
FL27402.1
Hampton Rlb Roof Panel
WALL SHEATHING
Carports Anywhere
FL27403.1
Hampton Rlb Wall Panel
SWINGING DOOR
THERMA—TRU CORPORATION
FL15225.1—R4
Classic —Craft
1i
LL
i I REVISED SPACING & FRAMECUTS p/[ /, 1 — 11
We: 8/10/18
Le9c�OR3ti n:
S. Indian River Dr., Ft. Pierce 34982
Model : 44'L X 52'W X 16'H
GENERAL NOTES
1. THIS BUILDING IS NOT EXEMPT FROM THE FBC ENERGY
CONSERVATION CODE PER SECTION 1015M.
2. ALL STEEL TUBING SHALL BE 50 KSI STEEL
3. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY
SET —BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE
THE RESPONSIBILITY OF THE OWNER.
4. ROOF AND WALL SHEATHING SECURED WITH 112-140"
SELF —DRILLING SCREWS WITH SEAL WASHERS O 6" O.C. MAX.
5. FI FRAMING CONNECTIONS SECURED WITH W12-14x3/4'
SELF—DRIWNG SCREWS.
6. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED.
7_ CONCRETE EXPANSIONS ANCHORS ARE TO BE (AINIMUM
1/2"x3 2.500LB TENSILE STRENGTH.
8.14GA FRAMING IS 2.5"x2.5" TUBE STEEL NIPPLES ARE
2.25"x2.25" TUBE STEEL
Ll
10/22/18
J
Q MattheW T. BaldWin P.E.
Florida License #64608
Lij
0 Sheet: CA-4 OF 4