HomeMy WebLinkAboutPRODUCT APPROVAL - SWINGING EXTERIOR DOOR1/27/2018 Florida Building Code Online r f It BUISMess, ° Professional ° - f 5.. _ s qaS Home i Login I User Regi adon I Hot Topics I Submit Surcharge I Stats & Facts j Pu... ns { FBc Staff i 6C[S Site Map Links I Seardr I d'b a ProductApproval USER: Public User s SCANNED • Product Approval Menu i Product or ApoilcaUon Search> Aoolicatfan "st> Appncation Detan BY FL # FL1S225-114 St Lucie County i Application Type Revision - Code Version 2017 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or• the Commission if necessary. i Comments Archived i Product Manufacturer.• Therma-Tru,Corporation Address/Phone/Email 118 Industrial Drive. Edgerton, OH 43517 (419). 2984740 - rickw@rwbldgconsultants:coM- Authorized Signature Vivian. Wright rickw@rwbldgcdnsuitants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email category Exterior Doors Subcategory Swinging Exterior Door -Assemblies Compliance Method Certification Mark or Usting Certification Agency National Accreditation.& Management Institute Validated :By Ryan J. King, P.E. o Validation Checklist - Hardcopy, Received Referenced Standard and Year (of Standard) Standard YeaK 101/I.S.2,. 1997 ASTM E1886 2002 ASTM E1996 2062 ASTM E330 2002 TAS 201, 202, 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional EngineerorArchitect FLI5225 R4 Eouiv (a) Eauivalencv-of Standards odf Product Approval Method Method 1.0ptlon A https://ww,wfloridabuilding.prg/pr/pr app dtl.aspx?param=wGEVXQwtDgv3yWKJZIQRASQx6OG%2b2JlO2u6kAoauKJijphgF6uTiA%3d%3d 113 1/27/2018 Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Orndue4g I https://vrww.floridabuildirtg,org/pr/pr app dtl.aspx7param=wGEVXQwtDgv3yWKJZiQRASQx6OG%2b2J102u6xAoauKJijphgF6uTlA%3d%3d 1 , Florida Building Code Online 09/21/2011 12/20/2017 12/22/2017 FL # Model, Number or Name Description . i5225.1 a. "Classic -Craft" and "Benchmark by 6/6 and 8/0 Opaque and Glazed Fiberglass Door with and Therma Tru" without Sidelites. Inswing and Outswing Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15225 R4 C CAC 15225 Y NAMI certs odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 12/31/1021 Design.Pressure: N/A Installation Instructions Other: See INST 15225.1-68 (6'8, Door Products), INST FL15225 R4 II (a) Inst 15225.1-68.Ddf 15225.140 (8'6.boor Products) and INST 15225-68M (6'8 FLIS225 R4 II (a) Insf 15225.1-80.adf Door Products.Direct to Masonry) for -Installation instructions. FL15225 R4 II (a) Inst 15225-68M.odf (Note - Glazing Shall comply with ASTM E1300=04) FL15225 R4 II FL-15225.1 Glazing Det..odf Verified, By: Lyndon F. Schmidt, P.E. 43409. Created by Independent Third Party: Yes Evaluation Reports FL15225 'R4 AE (a) Eval 15225.1-68.0f FLIS225 R4 AE' (a) Eval 152251-80 odf. FLIS225 R4 AE (al Eval15225-68M.Dd Created by Independent Third. Party: Yes' 15225.2 b. "Construction Series" and 6/8 Opaque Steel Door with and without Sidelites. Inswing and "Benchmark by Therma Tru" Outswing Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15225 R4 C CAC 15225.2 NAMI certs.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/31/2021 Design Pressure: N/A Installation. Instructions Other: See INST 15225.2-68 (6'8 Door Products) and,INST F� ti R ii (1 n 5 2 68 Ddfl 15225-68M (6'8 Door Products Direct to Masonry) for FL15 25- R4' II (a) Inst FL-15225-68MA.Ddf installation instructions. (Note - Glazing Shall comply with FL35225 R4 11 FL-15225.2 Glazing Det..Ddf ASTM E1300-04) Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FUS225 R4 AE (a) Eval 15225.2-68:odf FL35225 R4 AE (a) FL-15225-68MA.Ddf Created by Independent Third Patty: Yes 1522.5.3 c., "Fiber -Classic" and "Benchmark by 0/8 and 0/0 Opaque and Glazed Fiberglass Door with and Therma Tru" without Sidelites. Inswing and Outswing. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15225 R4 C CAC 15225.3 NAMI certs.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 12/31/2021 Design pressure: N/A Installation Instructions. Other: See INST 15225. 3-68 (6'8 Door Products), INST FLIS225 R4 II (a) Inst 15225.3-68.Ddf 15225.3-00 (8'0 Door Products) and INST 15225-68M (618 FL15225 R4 II (al 3nst 15225.3-80.odf Door Products Direct to Masonry) for Installation instructions: 171-15225 R4 II (a) Inst•15225-68M.Ddf Note'- Glazing Shall comply with.ASTM E1300-64. (This FL15225 R4 II FL-15225:3 Glulno Det..Ddf product approval requires the use of "Y' part number doors Verified By: Lyndon F. Schmidt, P.E. 43409 and Sidelites, which have been stained or painted within 6 Created by Independent Third Party: Yes months of installation - Excludes Opaque Benchmark Door Evaluation Reports Panels.) FL15225 R4 AE. (a) Eval 15225.3-68.odf FLIS225 R4 AE (a) Eval 15225.3-SO.odf FL15225 R4 AE (al Eval 15225-68M.Ddf Created by Independent Third Party: Yes 15225.4 d. "Premium Series" and 6/8 and 8/0 Opaque Steel Door with and without Sidelites. "Benchmark by Therma Tru" Inswing and Outswing Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15225 A4 C CAC 15225.4 NAMI certs.Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/31/2021 Design Pressure: N/A Installation Instructions Other: See INST 15225.4-68 (6'8 Door Products), INST FL15225 R4 II (a) Inst FL-15225-68MA.Ddf 15225.4-80 (8'0 Door Products) and INST 15225-68M (6'8 FL15225 R4' II (b) Inst 15225.4-68.Ddf Door Products Direct to Masonry) for installation instructions. FLIS225 R4 II (b) Inst 15225.4-60.Ddf. (Note - Glazing Shall comply with ASTM E1300-04) FL15225 R4 II FL-1522SA Glazing Det..odf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports 2/3 1/27/2018 Florida Building Code Online FL15225 R4 AE (a) FL-15225-68MA.Ddf FLIS225 R4 AE (b) Eval 15225.4-68.Ddf 'FL15225 R4 AE (b) Eval 15225 4-80 Ddf Created by Independent Third Party: Yes 15225.5 e. "Smooth -Star" and "Benchmark by Therma Tru" 6/8 and 8/0 Opaque and Glazed Fiberglass Door with and without Sidelites. Inswing and Outswing Limits of Use Certification Agency Certificate Approved for use in HVHZ:.No FL15225 R4 C'CAC 15225t5 NAMI certs.ocl Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 12/31/2021 Design Pressure: N/A Installation Instructions Other. See INST 15225.5-68 (6'8 Door Products), INST FLIS225 R4 'II WlInst 15225.5-68.Ddf 15225.5-80 (8'0 Door Products) and INST 15225-68M (6'8 FL15225 R411 (a) Insb 15225 5-80 Ddf Door Products Direct to Masonry) for installation instructions. FL15225• R4 .I (a) Inst 15225-68M.Ddf Note- Glazing Shall comply with ASTM E1300-04:. (This F1.15225 R4 II` FL-15225 5 Glazina DetDdf. product approval requires.the use of "Y' part number doors Verified By: Lyndon F. Schmidt, P.E. 43409, and sidelites, which have been stained or painted within 6 Created. by Independent Third Party: Yes months of installation - Excludes Opaque Benchmark Door Evaluation Reports Panels.) FL15225 R4 AE (a) Eval 15225 5-68 Ddf Fl i5»5 R4 AE (a) Eyal 15225:5-80.odf FL15225 R4 AE (a) Eval 15225-681VI.odf Created by.Independent Third Party: Yes 15225.6. f. "Premium Series", "Construction 6/8 and 8/0, Opaque and Glazed Steel. Door with.Transoms. Series" and "Benchmark by The'rma With and without Sidelites. Inswing and Outswing Tru" with Transoms Limits of Use Certification Agency Certificate Approved for use in HVHZ: No .. FL15225 R4 -C CAC 15225:6 NAMI certs.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 12/31/2021 . . Design Pressure: N/A Installation Instructions Other: See INST 15225.6-68 (6'8 Door Products) and FL15225 R4 II (a) Inst 15225.6-68.Ddf 15225.6-80 (B'0_ Door Products) forinstallation instructions. FL15225 R4 iI' (a) Ins* 15225 6-80 odf (Note - Glazing Shall comply with ASTM•E1300-04) FLIS225 R4 II FL 15225.6 Glazing Det..Ddf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15225 5225 R4 AE (a) Eval 15225.6-68.Ddf FL15225 R4 AE (a) Eva[ 15225 6-80 Ddf j Created by Independent Third Party: Yes. � Daclr Ne;at ContactUs::.2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-407-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accesslbillty Statement :: Refund Statement . Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by tradltional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees 11censed under Chapter 455, F.S. must provide the Department with an email address if they.have one. The emads provided may be used ror official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department With an email address which can be made available to the public. To determine if you are a licensee under Chapter 45S, F.S4 please dick here . Product Approval Accepts: IAN E o Credit Card Safe https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv3yWKJZIQRASQx6OG%2b2JlO2u6xAoauKJijphgF6uTiA%3d%3d 3/3 TH.ER.M A.,.ITRU THERMA TRU_ DOORS- 1 18 INDUSTRIAL DR., EDGERTON, OH4351"7 "Construction ' Series" 6'8" SINGLE AND DOUBLE OPAQUE PANELS W/ & W/OUT SIDELITES INSWING./ OUTSWING STEEL DOOR General Notes 1. T kproduct anchoring drawing has been developed in compliance.with the 6th Edition (2017) Florida. Building Code .(FBC) excluding the "High Velocity Hurricane Zone". See the Certification Agency Certificate for sizes, specifications and ratings. 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing, stucco, foam, brick and other wall coverings. 3. 3. Wood screws shall be installed following installation instructions of ANSI/AF&PA NDS 2015. All other fastener types to be installed following fastener manufacturers installation instructions. 4. Fastener embedment depths, edge distances and center -center distances shall be_as Specified by the fastener manufacturer but in no instance shall they be less than shown in this drawing.. 5. Where shims -are used, they must -be a" rigid / stiff' material that complies with the requirements of the FBC.. 6. (Positive and negative design pressure requirements for use with this drawing shall be determined by others for specific jobs in accordance with the governing code: 7. Site conditions not covered by this drawing are subject to further engineering analysis. TABLE OF CONTENTS SHEET # DESCRIPTION, 1 Typical elevations, design pressures & general notes 2 Buck anchoring 3 Frame anchoring 4 Frame anchoring & bill of materials 5 Horizontal &vertical cross sections 6 Vertical cross sections 37.50 OVI wl KA J 4 ;5= w 2 Jr o LU 5. ;� �I Q w g¢ 5 p I 0 oL� � i D 4. 5 6 6 Save MAX DESK +67.0 I MASONRY OPENING 2X BUCK --I k-- 4" d- MASONRY OPENING X '^ z 2X BUCK W) �. ^. Ci 4" 4" 11 I II -MULLION 4 j I SHOWN FOR TYP. II REFERENCE HEAD. I & JAMBS rr II II II II II II SINGLE W/SIDELITE BUCK ANCHORING I MASONRY OPENING NOTES: 1. 2X buck min. S.G. a 0.55. 2X BUCK CONCRETE ANCHOR NOTES: i. Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortar joints. 2. Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted to maintain the min. edge distance to mortar joints, additional concrete anchors may be required to ensure the "MAX. ON CENTER" dimension are not exceeded. 3. Concrete anchor table: i - ;I�NCHQR.'i. ANCNOR - :.......MIN..:;=`:.::: -'MIN. CLEARdNCE.':MIIt1rCLEA :...:...:.:.:::::::...::.-._.:.:;.;.•.:::::::::;.....::-:.............:•::. RA........., TO MASONRY TO;ADJACENT :....::..::::::.. `TYPE....: :.::::::•............::...::.:..::.::•:.:::::._::.::::•: S►E..:... :EMBEDMENT •:.:::•::•:::.•::::::::::•:::::EDGE.:::•::::=:::::::.•:..::• >ANCHOR.:•::;::::: ITW ® 4" 1-1/,C 2" 4" TAPCON ELCO ULTRACON® .`r . 4 II 4 II II TYP. HEAD & JAMBS I� ASTF II SHO II REFS II II II II II II II DOUBLE DOOI BUCK ANCHORI .. "D E T 1 3" . I I IF/ I I d t u MULLION Im . iut —. IIII SHOWN FOR REFERENCE Q � A W/2X BUCK INSTALLATION 0 9 W%1 X BUCK INSTALLATION d C TYP. HEAD & JAMBS — I III III Iw 15 ntt 2 Itu uu "C" SINGLE DOOR WfSIDELITES _w co 'CO ai IN PAIRS TYP. TYP. T C) - SEE DETAIL "4" ir) Q L �Ld - - �¢ T N� U) �. - j o 4 p •- b SEE U L. \ u.. DETAIL. N i ,,6,. a� VIEW "E"-"E" VIEW 1"-'D" SHOWN W/ OPTIONAL CORRUGATED FASTENERS, ITEM #30 (TYP. ALL SIDEUTE TO DOOR JAMB CONNECTI01 SIDEUTE NOTES: 1 f The sidelite is direct set into the jamb with (12) #8 x 2" pfh. wood screws. There are (4) at each vertical jamb, from the top down at 13.5 31. 48.5" & 66" There are (2) at the header at 4"from the outside comers of the frame; There are (2) at the sill, 4" from the outside corners. 2. For optional sidelite construction with staples,.sidelite is direct set into the jamb with (4), 716" X 1 314" 16 ga. staples along each jamb (6" from ends and equally spaced thereafter). CONCRETE ANCHOR NOTES: 1 Concrete anchor locations at the corners may be adjusted to maintain the min. edge distance to mortar joints. 2! Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted to 31 maintain the min. edge distance to mortar joints, additional concrete anchors may be required to ensure the "MAX. ON CENTER" dimension are not exceeded. Concrete anchor table: ANCHOR .';;:MIN. MIN CLEARANCE MtN CLEARANCE: : ANCHOR ..:: YP:.. 'i:EMBEDME(�!T TO MASONRY TO ADJACENT , . ....................... ....SIZE;::':` ::.........,.::...... ":............-...............::;:::::::::::EDGE:_::: _::"::: "..:::::::::•ANCHOR:::.::::: ITW 0 1/Y" 1-11/4" 27 4" TAPCON ITW TAPCON® 3/16" 1-1/4" 3" 1-1/2" Wv IN! W,. IN: IT m H Ln N N Ln .-7 J LL Co Co N N ey J LL N m C �3 ro 1 • INTERIOR m N w �w �a h. g N _ EXTERIOR 1 . HEAD JAMB 5 To, lxsub-buck Inswing shown INTERIOR EXTERK 2 HEAD JAMB' § To wood frame Inswing shown 13 2X BUCK INTERIOR 4 A. • a EXTERIOR •a. .26' MAX. SHIM SPACE 1.15'MIN. EMB. 1.25' MIN. EMB. TYP. 4 VERTICAL SIDE JAMB $ To 2x sub -buck Inswing shown R:\Clients\Therma Tru PERMANENT\A - Florida Product Approvals\FL-15225 Cert Mark- Install Only\C-- Drawings\FL-15225 (2017)\FL-15225.2,dwg, 6 �p, 1-1/4"MIN. EMB. (TYP.) Z m O Im -f m 1-1/4" MIN. EMB. (TYP.) m m Z 1-1/4" MIN. m EMB, (TYP.) ;0 0 7 1-1/4" MIN, - EMB. (TYP.) ,P .4 `I C. o• m . 2 f" � O �